CyrusOne | Data Center Solutions and Colocation Services

Carrollton
670,000 sq. ft.
GENERAL
•
•
•
•
•
•
•
•
•
•
•
•
Largest data center in the state - will support up to 670,000 sq. ft. data center / planned for
400,000 sq. ft. raised white floor, and 60,000 sq. ft. office space
One of the most efficient in the country
Massive Modular Scale; holds six 747s, 4 football fields, 15 Space Shuttles and 2 Washington
Monuments
SSAE 16 (SOC I type II), PCI DSS (sec 9 & 12), HIPAA, ISO 27001, FISMA, TIA 942 Class 4
Carrier-neutral and part of CyrusOne Texas IX (Internet Exchange)
100% uptime service level agreement on power
24x7 staffed NOCC and remote hands support
Dedicated cages and private suite options available
Wholesale and retail colocation options
Flood zone rating is Zone X (low risk)
Seismic zone rating is Zone 0 (lowest risk)
Commercial zone rating is light industrial
POWER
•
•
•
•
•
•
•
Can accommodate up to 60MW of critical capacity
150–200+ watts per sq. ft.
Multiple levels of redundancy available within same footprint (e.g. N, 2N)
Diverse power delivered by two independent circuits
750kVA Mitsubishi UPS systems; each power leg has a dedicated UPS with battery back-up
Scalable 2.25 MW Detroit Diesel dedicated generators pre-wired for additional capacity
5,000 gallon belly tank per generator
COOLING
•
•
•
•
•
•
•
•
36-inch raised floor design
Modular/Scalable cooling design
Hybrid cooling systems – unique indirect evaporative with redundant DX – 80% free cooling
Indirect evaporative cooling units provide best in class efficiency
Utilizes free air cooling
NO CRAC/CRAH units on datacenter floor
NO water on datacenter floor.
35 ft. ceiling height from datacenter floor
SECURITY
•
•
•
•
•
•
Reinforced physical structure including concrete bollards, steel-lined walls for security, and
bullet resistant glass
Video surveillance and recording of the exterior and interior
On-site security guards 24 hours a day, 365 days a year
Man traps, revolving entrance doors; biometric and key card (color coded) security for rigid
access control
Cabinet and cage security options include individual locks and biometric scanners
Perimeter fence
FIRE PROTECTION
•
ery Early Smoke Detection Apparatus (VESDA) system; sampling air in parts per million
V
coupled with a zonal dual-action interlocking dry-pipe system
AMENITIES
•
•
•
60,000+ office space, Common areas, Recreation center, Premium customer offices and
kitchen
Helicopter pad; 9 Minutes from DFW International Airport
Gordon grid dropdown ceiling; No height restrictions on cabinets