Crest Building Consultancy Ltd 5382 Parker Avenue Victoria V8Y 2M9 Tel: (250) 888 9182 Fax: (250) 727 3723 Email: [email protected] Web: www.crestbc.ca BUILDING INSPECTION Address of Property: 31 Uttoxeter Road, Victoria Date of Inspection: Client: Mr.B.Uyer Inspector: Lee Ottewell THE INSPECTION PARAMETERS This visual inspection has been undertaken in accordance with the ASTM standard E2018-01 protocol for Property Condition Assessments. All the internal rooms of the retail units were inspected, however, the hotel rooms were sampled. MAIN FINDINGS SITE An old oil tank exists in the basement. It is enclosed in a concrete blockwork surround. It should be checked to ensure that it doesn't contain any oil and that there isn't a risk of spillage. EXTERIOR The brickwork is in poor condition, sections have spalled, sections are damaged and the all the mortar joints require repointing. The decorative cornice on the facade of the building is rotting. The vinyl and metal siding on the lightwell walls is in poor condition and sections of the metal siding are buckled. The windows and some door frames are in very poor condition - sections are rotting and other sections are missing. A planter at the rear of the building should be further investigated to establish if there is an adequate water proof membrane between the soil and adjacent walls. I noted an exposed section of an older style clay perimeter draintile. This will need cleaning out and an invasive draintile survey to establish if it is still functioning. However, based upon the age of the building the likelihood is that it will require replacing. There are other minor exterior issues such as ductwork being used for downpipes, rotting fascia board etc. ROOF The upper roof has a "tar and gravel" covering which is in poor condition. Sections are cracking and blistering. The cap flashings at the junction of the roof and the parapet walls have rusted through in many areas. The lower level roofs are torch-on asphalt and are also in poor condition. I noted soft spots and ripples in the asphalt. There is inadequate drainage on the lightwell roof (only one roof scupper). The metal fire escape bracing is loose and there is debris on the upper roof. There are three chimneys on the property. The front one is in reasonable condition. The rear two are in a poorer condition and have very poor flashing details. ELECTRICAL There is a 400amp overhead electrical supply serving the building. The supply feeds into a distribution box which supplies the individual fuses and panels for the retail units and the hotel. By today's standards 400amps for a building of this size is considered low. Redundant sections of the older style knob and tube wiring were visible in the attic (I confirmed that no electricity was still passing through the cables). During the inspection I did note several ungrounded 3 pin outlets and many of the older style 2 pin outlets. This could be an indication of some active, remaining knob and tube wiring in the building (this type of wiring only had a hot and neutral - no ground wire). Recommend having this checked out further by a licensed electrician. I also noted some aluminium branch wiring in use in one of the panels in one of the retail units. ROOF VOID AND INSULATION There is no insulation in the roof void nor is there any visible in the crawlspace. Due to the age of the building there is unlikely to be any in the walls. The visible roof framing appeared to be satisfactory. STRUCTURAL The brick walls all appeared plumb and there was no signs of serious cracking. Whilst inspecting the hotel I noted that several floors were sloping, the staircases were sloping and in one room there was a clear gap at the junction of wall and ceiling. Although there was no access into the crawlspace there were many clues suggesting concealed problems. They consisted of: • • • • • a fallen joist (at the front of the crawlspace) sloping floors at the rear of both retail units especially 705 floors which appeared to have been levelled in the retail units (using plywood on firring pieces) visible rot in an exposed joist at the rear of unit 705 • sections of the floor which have separated from the walls in unit 705 I strongly recommend that several access holes are cut in both ground floor retail units to enable the condition of the concealed framing and foundation to be determined. HEATING AND VENTILATION Unit 707 is heated by two ceiling mounted gas furnaces. The units are manufactured by Lennox and appear to be in satisfactory condition. However, it was not possible to test the units because the gas supply was off. Unit 705 and the hotel are heated by steam circulating through radiators. The steam is generated by two gas powered boilers. Both appeared to be in good condition and were working satisfactory at the time of the inspection. However, several upgrades and replacement of components is required There was no functioning mechanical ventilation to the common areas of the hotel. PLUMBING Sections of galvanized piping are still in use in the building. This type of piping is prone to rusting and hence leaks. There are many stains on the ceiling, especially in the retail units, suggesting ongoing problems with this. There are two gas fired hot 125 gallon hot water tanks in the boiler room - both appeared functional and in reasonable condition. One hot water tank was shut down and isolated at the time of the inspection. INTERIOR OF HOTEL The general condition of the interior of the hotel is poor. Typical issues include: • • • • • • • • • damaged floor finishes broken or missing glazing to windows damaged windows damaged vanity units cracks in walls and ceilings damaged wall finishes missing radiators ungrounded 3 pin electrical outlets poor quality plumbing installations I also noted sloping on the corridor floors and the staircases. Throughout the hotel there is evidence of rodent infestation (mice) and cockroaches. INTERIOR OF UNIT 105 The general condition of this former hairdressing salon was poor. Typical issues include: • • • • • • • • significant sloping in the floor toward the rear of the unit (1 inch in every 3 feet) separation of the floor from the walls at the rear of the unit poor quality internal framing and drywalling what appears to be mould growth above the suspended ceiling water staining on the ceiling minor electrical and plumbing items damaged to the lath and plaster ceiling above the suspended ceiling. blocked off window INTERIOR OF HOTEL OF 107 The general condition of this unit is reasonable. Typical issues include: • staining on the suspended ceiling tiles throughout • water damaged to some joists above the suspended ceiling • minor electrical items • damaged to the lath and plaster ceiling above the suspended ceiling. THE REPORT INDEX INSPECTION CONDITIONS SITE EXTERIOR OF BUILDING ROOF ELECTRICAL ATTIC & VENTILATION STRUCTURAL HEATING, VENTILATION & AIR CONDITIONING INTERIOR Managers Suite UNIT 105 UNIT 107 NSA ADDENDUM 1 2 4 11 16 22 23 27 29 45 46 55 THE REPORT Inspection of 31 Uttoxeter Road, Victoria on INSPECTION CONDITIONS Client Information: Inspection Commencement Date: July 17th 2008. Client's Name: Mr.B.Uyer. Address of Property Inspected: 31 Uttoxeter Road, Victoria. Access Provided By: Via the buyer's agent. Weather Conditions: Inspection Day Weather: Clear. Temperature At The Time Of The Inspection: Between 10 & 15 degrees celsius. Soil Conditions: Damp. Building Characteristics: Approximate Year In Which The Building Was Built: 1901. Building Type: Hotel with 35 rooms above 2 retail stores on the ground floor. Payment Information: Fee: $6,325.00 + GST ($6,641.25 total) Page 1 Page 2 Inspection of 31 Uttoxeter Road, Victoria on SITE Site: Orientation: For the purposes of this report all directional references to left, right, front, or rear assume the reader is standing at the street facing the building being inspected. Patio Patio Floor Materials: Concrete. Patio Condition: Satisfactory - The patio surface material is in satisfactory condition. Patio Enclosure Condition: Action Necessary there was some minor damage to the corrugated plastic roof and there was no flashing between the roof and the wall. Utility Services: Electric Service: Electric Service Condition: Overhead. Satisfactory - The overhead electrical service lines are secure at masthead. Service wires are unobstructed and in good condition. Gas Service: The building is connected to a mains gas supply. Gas Odour Noted: No. Above Ground Oil Tank Yes - inside the house. Inspection of 31 Uttoxeter Road, Victoria on Oil Tank: Action Necessary - the oil tank is no longer in use. It is enclosed in concrete blocks and it's condition is unknown. It is also unclear if it is empty of oil. Page 3 Inspection of 31 Uttoxeter Road, Victoria on EXTERIOR OF BUILDING Exterior: Brickwork Condition: Brickwork Condition: Action Necessary - the brickwork requires the mortar repointing. Action Necessary surfaces of the brickwork are spalling in many areas. Page 4 Inspection of 31 Uttoxeter Road, Victoria on Brickwork Condition: Action Necessary sections of brickwork are damaged. Type Of Siding: Vinyl and metal. Siding Condition: Action Necessary - the metal siding (located in the lightwell) is buckled. Page 5 Inspection of 31 Uttoxeter Road, Victoria on Siding Condition: Fascia & Barge Boards: Condition of Painted Surfaces: Page 6 Action Necessary - the junction of the metal siding and the adjacent wall is poor. Action Necessary - The fascia boards are rotting. Action Necessary - The majority of the exterior painted surfaces require repainting. Inspection of 31 Uttoxeter Road, Victoria on Outside Entry Doors: Action Necessary - The outside rear entry door frames to unit 707 are damaged. Windows Type: Fixed and vertical sliding sash windows. Glazing: Single. External Window Frame & Trim Condition: Action Necessary many of the windows are in poor condition with rotting and damaged frames. Page 7 Inspection of 31 Uttoxeter Road, Victoria on External Window Frame & Trim Condition: Downspouts: Page 8 Action Necessary - the brick cills underneath some windows are in very poor condition. Action Necessary metal ductwork (dryer vent) has been used as a downspout at the rear of unit 705 Action Necessary Some downspouts are not discharging their run-off water correctly. Run-off water needs to flow away from the side of the building at least 6 feet. This will allow the run-off to get far enough away to not interfere with the foundation. Alternatively downspouts could be connected into drains. Comments: Action Necessary - at the rear of units 705 and 707 voids above windows, around vent ductwork etc have been flled in with a combination of bare plywood, painted plywood and plywood with a stucco finish. All have been poorly undertaken. Inspection of 31 Uttoxeter Road, Victoria on Page 9 Foundation Type of Foundation: Crawlspace. Foundation Materials: Poured in place concrete. Visible Portions of Exterior Foundation: None. Landscaping: Planters Action Necessary there is a large stone walled planter against the building. It is located at the rear against the left hand flank wall to unit 707. The planter is full of soil and is over grown. There is a risk of water penetration through the flank brick wall. Perimeter Foundation Drains Sections of Perimeter Drain Tile Visible: Yes - At least one end of the drain exposed to daylight was noted. This inspection does not warrant the effectiveness of the drainage system nor does it confirm that there is a fully functioning draintile present - the inspector can only see what is visible above grade. Inspection of 31 Uttoxeter Road, Victoria on Type of Drainage Tile: Comment Page 10 A clay section was visible at the rear of unit 705. Action Necessary - due to the age of the building and the fact that the draintile appears to be an old concrete/clay version - I recommend an invasive draintile survey (using a company such as Roto Rooter) to establish presence and condition of the drainage tile. Page 11 Inspection of 31 Uttoxeter Road, Victoria on ROOF Roof: Means of Roof Inspection: By walking on the roof. Type Roof: Flat. Roof Covering Materials: Tar and gravel on the upper roof and torch-on asphalt on the lower roofs. Condition of Roof Covering Material: Condition of Roof Covering Material: Action Necessary sections of the asphalt have broken up. Action Necessary sections of the asphalt have bled through the gravel. Inspection of 31 Uttoxeter Road, Victoria on Condition of Roof Covering Material: Action Necessary there were soft spots and ripples in the torch on asphalt on both the lower roofs. Drainage: Action Necessary there is only one scupper to the lightwell roof. Flashing: The majority of the perimeter cover flashings were in poor condition. This photograph shows a section that has rusted through. Page 12 Inspection of 31 Uttoxeter Road, Victoria on Roof Framing, Exterior, notes: Gutters: Detached Garage Roof Comment: Page 13 Attention Necessary there was debris on the upper roof. Attention Needed - The gutters need cleaning out. It is also prudent to re-caulk all the joints periodically. Action Necessary - the flashing above the front cornice is in poor condition at the joints eg where it adjoins the building facade and the overlapping joints. Action Necessary - the fire escape metal bracing is loose. Inspection of 31 Uttoxeter Road, Victoria on Page 14 Chimney : Location: Front of the property. Exterior Stack Material: The exterior fireplace stack is made of masonry. Exterior Stack Condition: Satisfactory - The exterior stack is in satisfactory condition. Flue Lined: Yes - The flue appears to be lined with metal. Chimney Cap or Crown: Yes - There is a chimney cap. Chimney Height and Clearance: Yes - The chimney installation appears to meet clearance requirements. Flashing: Satisfactory - The installed flashing around the chimney stack appears to be functional. Chimney 2 : Location: Middle of the property. Exterior Stack Material: The exterior fireplace stack is made of masonry. Exterior Stack Condition: Flue Condition From Roof: Action Necessary - The exterior stack has a condition that calls for repair. The chimney shows evidence of brick spalling. Cause is due to moisture getting into the bricks then freezing which flakes off the surfaces of the bricks. The chimney was capped off and not in use. Action Necessary - the cap was not secured to the chimney stack and could blow off. Flue Lined: No - The flue is not lined. Chimney Height and Clearance: Yes - The chimney installation appears to meet clearance requirements. Flashing: Action Necessary - The flashing installation is poor. Repair or replacement is needed to prevent water entry. Inspection of 31 Uttoxeter Road, Victoria on Page 15 Chimney 3 : Location: Rear. Exterior Stack Material: The exterior fireplace stack is made of masonry. Exterior Stack Condition: Satisfactory - The exterior stack is in satisfactory condition. Flue Lined: No - The flue is not lined. Chimney Height and Clearance: Yes - The chimney installation appears to meet clearance requirements. Flashing: Action Necessary - The flashing installation is poor. Repair or replacement is needed to prevent water entry. Page 16 Inspection of 31 Uttoxeter Road, Victoria on ELECTRICAL Main Power Supply: Description: There is a 400amp overhead electrical supply to the building. The supply serves a distribution box which feeds the individual fuses and panels for the retail units and the hotel. Electrical Room Location: Behind the reception of the hotel on the 2nd floor. Service Cable to Panel Type: Copper. Main Isolator: The main shuttoff is a fuse box. Panel Cover Removed: Yes - all the fuse/breaker panels were removed and checked. Panel Condition: Breaker/Fuse to Wire Compatibility: Condition of Wiring in Panel: Main Service Ground Verified: Satisfactory - The power panel, as a container for safely covering electrical circuitry and components, is functioning as intended, minimizing the risk of electrical shock. Satisfactory - The breakers/fuses in the main power panel appear to be appropriately matched to the circuit wire gauge. Satisfactory - Electrical circuitry wiring in the panel appears neatly arranged with no unallowable splices. No - The main service ground wire was not verified by the inspector. What this means is that the he was not able to see the grounding wire along it's entire length from the panel to the grounding source (copper pipe, rods etc). This is common if the wire is hidden behind walls etc. Hotel Main Panel: Location: Behind the reception in the meter cupboard. Service Size: 200amps. Inspection of 31 Uttoxeter Road, Victoria on Page 17 Service Cable to Panel Type: Copper. Is Panel Accessible: Yes - The electrical panel is in a location that makes it readily accessible. Panel Type: The main shuttoff is a fuse box serving a breaker distribution panel. Panel Cover Removed: Yes. Panel Condition: Breaker/Fuse to Wire Compatibility: Legend Available: Condition of Wiring in Panel: Circuit Wiring Type: Satisfactory - The power panel, as a container for safely covering electrical circuitry and components, is functioning as intended, minimizing the risk of electrical shock. Satisfactory - The breakers/fuses in the main power panel appear to be appropriately matched to the circuit wire gauge. Yes - Identification of the breakers and the appliances or areas they control are clearly marked. This inspection does not verify the accuracy of this legend. Satisfactory - Electrical circuitry wiring in the panel appears neatly arranged with no unallowable splices. Sheathed Copper cabling was visible. Sub Panels: The adjacent subpanel and the subpanel on the 3rd floor were also inspected. The fronts were removed and both the wiring and the breakers were checked. All appeared satisfactory. Comment: Knob and tube wiring was also visible, in the attic space. However when tested it didn't show any current running through. Inspection of 31 Uttoxeter Road, Victoria on Comments: Page 18 Action Necessary although during the inspection I didn't note any active 'knob and tube' wiring I did note several ungrounded 3 pin outlets. This could be an indication of some active, remaining knob and tube wiring in the building (this type of wiring only had a hot and neutral - no ground wire). Recommend having this checked out further by a licensed electrician. Unit 707 Panel: Location: Reception. Panel Type: Breaker type power panel. Panel Cover Removed: Yes. Panel Condition: Breaker/Fuse to Wire Compatibility: Satisfactory - The power panel, as a container for safely covering electrical circuitry and components, is functioning as intended, minimizing the risk of electrical shock. Satisfactory - The breakers/fuses in the main power panel appear to be appropriately matched to the circuit wire gauge. Legend Available: Yes - Identification of the breakers and the appliances or areas they control are clearly marked. This inspection does not verify the accuracy of this legend. Panel Cover Removed: Yes. Condition of Wiring in Panel: Circuit Wiring Type: Satisfactory - Electrical circuitry wiring in the panel appears neatly arranged with no unallowable splices. Copper - The structure is wired using plastic insulated copper single conductor cables. Inspection of 31 Uttoxeter Road, Victoria on Page 19 Unit 707 Panel 2 Location: Store Room off reception. Panel Type: Breaker type power panel. Panel Cover Removed: Yes. Panel Condition: Breaker/Fuse to Wire Compatibility: Satisfactory - The power panel, as a container for safely covering electrical circuitry and components, is functioning as intended, minimizing the risk of electrical shock. Satisfactory - The breakers/fuses in the main power panel appear to be appropriately matched to the circuit wire gauge. Legend Available: Yes - Identification of the breakers and the appliances or areas they control are clearly marked. This inspection does not verify the accuracy of this legend. Panel Cover Removed: Yes. Condition of Wiring in Panel: Circuit Wiring Type: Action Necessary There were some poorly terminated wires. Copper - The structure is wired using plastic insulated copper single conductor cables. Unit 705 Panel 1: Labled: Unit 705 Panel 'P' Panel Type: Breaker type power panel. Panel Cover Removed: Yes. Panel Condition: Action Necessary - There are open slots in the panel breaker cover where a breaker is missing. Inspection of 31 Uttoxeter Road, Victoria on Breaker/Fuse to Wire Compatibility: Page 20 Satisfactory - The breakers/fuses in the main power panel appear to be appropriately matched to the circuit wire gauge. Legend Available: Yes - Identification of the breakers and the appliances or areas they control are clearly marked. This inspection does not verify the accuracy of this legend. Panel Cover Removed: Yes. Condition of Wiring in Panel: Circuit Wiring Type: Satisfactory - Electrical circuitry wiring in the panel appears neatly arranged with no unallowable splices. Copper & aluminum Action Neccessary - Aluminium wiring is being using as "branch wiring" in this property. Aluminium wiring can cause overheating of receptacles due to a phenomenon called 'creep'. It is therefore advisable to have all receptacle connections and panel connections checked by a qualified electrician. Special connections are required eg pig tailing with copper before connecting to the receptacle alternatively special receptacles should be used that are suitable for aluminium wiring. Unit 705 Panel 2: Location: Unit 705. Panel 'L' Panel Type: Breaker type power panel. Panel Cover Removed: Yes. Panel Condition: Breaker/Fuse to Wire Compatibility: Satisfactory - The power panel, as a container for safely covering electrical circuitry and components, is functioning as intended, minimizing the risk of electrical shock. Satisfactory - The breakers/fuses in the main power panel appear to be appropriately matched to the circuit wire gauge. Legend Available: Yes - Identification of the breakers and the appliances or areas they control are clearly marked. This inspection does not verify the accuracy of this legend. Panel Cover Removed: Yes. Condition of Wiring in Panel: Circuit Wiring Type: Satisfactory - Electrical circuitry wiring in the panel appears neatly arranged with no unallowable splices. Copper - The structure is wired using plastic insulated copper single conductor cables. Inspection of 31 Uttoxeter Road, Victoria on Page 21 Unit 705 Panel 3: Location: Unit 705. Panel Type: Breaker type power panel. Panel Cover Removed: Yes. Panel Condition: Breaker/Fuse to Wire Compatibility: Satisfactory - The power panel, as a container for safely covering electrical circuitry and components, is functioning as intended, minimizing the risk of electrical shock. Satisfactory - The breakers/fuses in the main power panel appear to be appropriately matched to the circuit wire gauge. Legend Available: Yes - Identification of the breakers and the appliances or areas they control are clearly marked. This inspection does not verify the accuracy of this legend. Panel Cover Removed: Yes. Condition of Wiring in Panel: Circuit Wiring Type: Satisfactory - Electrical circuitry wiring in the panel appears neatly arranged with no unallowable splices. Copper - The structure is wired using plastic insulated copper single conductor cables. Inspection of 31 Uttoxeter Road, Victoria on Page 22 ATTIC & VENTILATION Attic & Ventilation: Method of Inspection: Viewed from the access hatch. Roof Framing Condition: Satisfactory - The roof framing appears to be in functional condition. Roof Ventilation: Vapour Barrier Installed: Insulation Noted: Bathroom/Kitchen/ Dryer Vents: Evidence of Animals in Attic: Action Necessary - There is some ventilation installed; however, the existing venting does not allow adequate ventilation for the attic cavity. Action is necessary to correct this shortage of ventilation. There was no vapour barrier noted in the attic cavity. Action Necessary - there was no insulation noted. Attention Needed - Internal vent ductwork from bathrooms/kitchen range hoods etc should vent directly outside to ensure that additional moisture is not introduced into the attic space and insulation. Due to access restrictions in the attic it was not possible to see all the ductwork in the attic space and therefore the inspector was unable to confirm that all the vents discharge outside. Recommend getting this checked out further. Yes - There was evidence rodent activity in the attic space. It was not possible to conclude if was a previous or present infestation. Nor was it possible to establish the extent of the infestation. Page 23 Inspection of 31 Uttoxeter Road, Victoria on STRUCTURAL GENERAL: Comments: Action Necessary - although there was no access into the crawlspace there were many clues suggesting concealed problems. They consisted of: • • • • • a fallen joist (at the front of the the crawlspace) sloping floors at the rear of both retail units especially unit 705 floors which appear to have been levelled in the retail units (using plywood on firring pieces) visible rot in an exposed joist at the rear of unit 705. sections of floor which have separated from the walls in unit 705 I strongly recommend that several access holes are cut in both the ground floor retail units to enable access into the crawlspace areas to check the concealed framing below. INTERIOR VIEW of BASEMENT Interior of Basement Percentage Finished Into Living Space: Ceiling Joists Conditions: Comments: Condition Noted in Foundation Walls, Interior View: Columns: None. The ceiling joists were not visible for inspection - they were obscured by panelling. Action Necessary - the ceiling was panelled. The panelling was loose in areas, the material is likely to be asbestos. Satisfactory - The exposed visible portions of the interior foundation perimeter walls appear to be satisfactory. Concrete. Inspection of 31 Uttoxeter Road, Victoria on Columns Condition: Main Beam(s): Main Beam Conditions: Underside of Sidewalk: Evidence of Water Entry in the Basement: Page 24 Satisfactory - The visible column(s) appear in satisfactory condition and adequately installed. Concrete. Satisfactory - The visible sections of main beam(s) as installed appear to be in satisfactory condition. Action Necessary - I noted spauling concrete and rusting rebar around the side walk (former coal hatch). The hatch was also allowing water ingress into the basement area. Action Necessary - At the time of the inspection there was water present. Inspection of 31 Uttoxeter Road, Victoria on Electrical Service to Basement level: Evidence of Animals in Basement: Page 25 Action Necessary - that due to the high moisture levels a distribution box and fuse box were rusting. Yes - Animal droppings were noted in the basement. CRAWLSPACE Crawlspace Inspected By: Ceiling Joists Conditions: Due to height restrictions it was not possible to enter the crawlspace. I could only view the crawlspace from 2 access holes in the basement area. Action Necessary - I noted a rotten joist hanging down located at the front section of the building. Condition Noted in Foundation Walls, Interior View: Not visible. Columns: not visible. Inspection of 31 Uttoxeter Road, Victoria on Evidence of Water Entry in the Crawlspace: not visible. Main Beam: not visible. Crawlspace Floor: Dirt. Vapour Barrier Installed: Insulation Noted: Page 26 No - There is no vapour barrier installed. Exposed soils in a crawlspace should be covered with a retardant material to prevent moisture or standing water from deteriorating wood framing above. Approved materials include: polyethylene. No, Recommend insulation either in the walls or the ceiling above. If the walls are insulated then all exposed pipes and ductwork will also need insulating and the space will require ventilation. It is more desirable to insulate the walls and create a warm environment which will help keep the floor above warm. Inspection of 31 Uttoxeter Road, Victoria on Page 27 HEATING, VENTILATION & AIR CONDITIONING Heating System: Heating System Type: Unit. 707 is heated by 2 warm air gas furnaces located above the rear suspended ceiling. The were not functional at the time of the inspection. Owner advised that the gas supply was likely to be off. The Lennox units appear to be about 15 years old. The have fresh air inlets at the rear of the building and the supply air is ducted within the suspended ceiling. Fuel Source: The fuel source is natural gas. Flue Condition: Satisfactory - The visible portions of the flue/vent system appear to be installed correctly and appear to be functional. Carbon Monoxide Tested: No - unable to test the gas furnaces were not functioning. Heating System Tested: Comments: Secondary Air Adequacy: The gas supply was disconnected - unable to test. Recommend having the units serviced. Action Necessary - the external air inlets had missing grilles. Satisfactory - Availability of secondary air for combustion and flue draft appears to be adequate; however, no calculation was performed by the inspector. Inspection of 31 Uttoxeter Road, Victoria on Filter Condition: Attention Needed - The filters need changing. Ducts Condition: Action Necessary - There are disconnected sections of ductwork. Thermostat Condition: Satisfactory - The thermostat worked properly when tested. Comments: Action Necessary - I noted a missing radiator on the 3rd floor corridor. Page 28 Page 29 Inspection of 31 Uttoxeter Road, Victoria on INTERIOR Room 30: Location: 2nd floor, front right side of building looking into the lightwell. Entry Door: Satisfactory - The entry door to this room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Attention Needed The floor tiles in this room are damaged in places. Windows: Action Necessary - There is at least one window in this room that requires it's hardware adjusting to enable it to operate correctly. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Comments: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. The washand basin and vanity unit were in functional condition. Room 28: Location: 2nd floor, front right side of the building looking towards the street. Entry Door: Satisfactory - The entry door to this room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Inspection of 31 Uttoxeter Road, Victoria on Page 30 Floor: Attention Needed The floor in this room is damaged in places. Windows: Action Necessary - There is at least one window in this room that requires it's hardware adjusting to enable it to operate correctly. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. The washand basin and vanity unit were in functional condition. Room 45: Location: 2nd floor, rear left of the building looking over the rear yard area. Entry Door: Satisfactory - The entry door to this room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Inspection of 31 Uttoxeter Road, Victoria on Page 31 Floor: Attention Needed The floor in this room is damaged in places. Windows: Action Necessary - There is at least one broken window pane and the hardware needs adjusting to enable it to operate correctly. Electrical Outlets: Action Necessary - At least one 3-pronged outlet in the room is not grounded. This is an unsafe condition. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. The washand basin and vanity unit were in functional condition. Room 43: Location: 2nd floor, rear of the building looking over the rear yard. Entry Door: Satisfactory - The entry door to this room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Inspection of 31 Uttoxeter Road, Victoria on Page 32 Floor: Attention Needed The floor in this room is damaged in places. Windows: Action Necessary - One or more of the sash cords is broken or missing. This condition could allow the window to slam closed causing glass breakage or injury to unsuspecting individuals. Electrical Outlets: Action Necessary - At least one outlet in the room needs a new cover. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Action Necessary - the vanity unit is damaged. Inspection of 31 Uttoxeter Road, Victoria on Page 33 Room 37: Location: 2nd floor, rear looking forward over the lightwell. Entry Door: Satisfactory - The entry door to the dining room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Attention Needed - The floor in this room is damaged in places. Windows: Action Necessary - There is at least one broken window pane and the hardware needs adjusting to enable it to function satisfactory. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. The washand basin and vanity unit were in functional condition. Workshop: Location: 2nd floor, rear looking forward over the lightwell. Entry Door: Satisfactory - The entry door to this room is functional. Walls: Action Necessary movement cracks were noted. Ceiling: Action Necessary - there is some damage to the lath and plaster ceiling. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Action Necessary - There is at least one broken window pane and the hardware requires adjusting. Electrical Outlets: This room contains 2-prong ungrounded outlets. These outlets are not grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Inspection of 31 Uttoxeter Road, Victoria on Comment: Page 34 Action Necessary there was no trap on the sinks. Laundry Location: Top floor. Entry Door: Satisfactory - The entry door to the laundry room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Dryer Ventilation: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Satisfactory - The dryer ventilation as installed appears adequate. Room 44: Location: 2nd floor rear looking over the back yard. Entry Door: Satisfactory - The entry door on the master bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Action Necessary - One or more of the sash cords is broken or missing. This condition could allow the window to slam closed causing glass breakage or injury to unsuspecting individuals. Electrical Outlets: Action Necessary - At least one 3-pronged outlet in the room is not grounded. This is an unsafe condition. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Inspection of 31 Uttoxeter Road, Victoria on Comment: Page 35 The washand basin and vanity unit were in functional condition. Room 36: Location: 2nd floor store, left side adjacent to the lightwell. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Attention Needed - There is some minor damage to the wall surface. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: None. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Action Necessary - a sink/washand basin has been removed and the plumbing hasn't been properly capped off (also note that galvanized piping is still in use here). Room 35: Location: 2nd floor, left side, looking forward into the lightwell. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Attention Needed - There is some minor damage to the wall surface. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Action Necessary - There is at least one window in this room that requires it's hardware adjusting to enable it to operate correctly. Electrical Outlets: Action Necessary - At least one 3-pronged outlet in the room is not grounded. This is an unsafe condition. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Inspection of 31 Uttoxeter Road, Victoria on Comment: Page 36 The washand basin and vanity unit were in functional condition. Store: Location: End of corridor on 2nd floor. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Store 2: Location: End of corridor on 3rd floor. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Room 67: Location: 3rd floor, rear left looking over the rear yard. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Inspection of 31 Uttoxeter Road, Victoria on Page 37 Walls: Attention Needed Some cracks were noted. Ceiling: Attention Needed - Some cracking was noted. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Action Necessary - There is at least one broken window pane and the hardware requires adjusting. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. The washand basin and vanity unit were in functional condition. Room 62: Location: 3rd floor, rear right looking over the rear yard. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Inspection of 31 Uttoxeter Road, Victoria on Page 38 Windows: Action Necessary - the bottom sash of the window was missing and a section of clear plastic (too narrow), has been used to secure the hole. Electrical Outlets: Action Necessary - At least one 3-pronged outlet in the room is not grounded. This is an unsafe condition. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Action Necessary - a radiator was disconnected. Inspection of 31 Uttoxeter Road, Victoria on Comment: Page 39 The washand basin and vanity unit were in functional condition. Room 60: Location: 3rd floor, rear looking forward into the lightwell. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Attention Needed The floor surface in this room is damaged in places. Windows: Action Necessary - There is at least one window in this room that requires it's hardware adjusting to enable it to operate correctly. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. The washand basin and vanity unit were in functional condition. Room 49: Location: 3rd floor, front middle of the property, facing the street. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Satisfactory - The window(s) in this room appear to be satisfactory. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Inspection of 31 Uttoxeter Road, Victoria on Comment: Page 40 The washand basin and vanity unit were in functional condition. Room 51: Location: 3rd floor, front right, looking towards the street. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Action Necessary - There is at least one window in this room that requires it's hardware adjusting to enable it to operate correctly. Electrical Outlets: Action Necessary - the socket is hanging loose. Light and Light Switch. Comment: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. The washand basin and vanity unit were in functional condition. Room 52 Location: 3rd floor, facing rearwards into the lightwell. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Inspection of 31 Uttoxeter Road, Victoria on Walls: Attention Needed There is some damage to the wall surface. Ceiling: Action Necessary there is no finished ceiling, merely plywood. Floor: Satisfactory - The floor in this room is in satisfactory condition. Page 41 Inspection of 31 Uttoxeter Road, Victoria on Windows: Action Necessary There is at least one broken window pane. Electrical Outlets: Action Necessary - At least one outlet in the room is loose. Light and Light Switch. Comment: Page 42 Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Action Necessary - the washand basin and sink were in a poor state. Inspection of 31 Uttoxeter Road, Victoria on Page 43 Ladies Bathroom: Location: 2nd floor. Entry Door: Satisfactory - The entry door to the bathroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Ventilation Fans: Satisfactory - There is an exhaust fan installed in this bathroom, and it is performing satisfactorily. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Basin and Drain Fixture: Satisfactory - The basin and drainage fixture appears to be satisfactory. Faucet and Supply Lines: Satisfactory - Faucets and supply lines appear satisfactory. Toilet Condition: Satisfactory - The toilet appears to be functional. Tub: Satisfactory - the bath tub is not damaged and functions as intended. Tub Faucets: Satisfactory - The tub faucets operate as intended. Tub & Shower Walls: Satisfactory - The walls appear to be in satisfactory condition. Tub Drain: Satisfactory - The tub appears to drain at an acceptable rate. Glass Tub/Shower Door: There is a shower rod installed. Gents Bathroom: Location: 2nd floor. Entry Door: Satisfactory - The entry door to the bathroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Attention Needed The floor in this room is damaged in places. Inspection of 31 Uttoxeter Road, Victoria on Ventilation Fans: Light and Light Switch. Page 44 Satisfactory - There is an exhaust fan installed in this bathroom, and it is performing satisfactorily. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Toilet Condition: Satisfactory - The toilet appears to be functional. Shower Pan: Satisfactory - the shower pan is not damaged and functions as intended. Shower Faucets: Satisfactory - The shower faucets operate as intended. Shower Walls: Action Necessary - the grounting was in poor condition. Shower Drain: Satisfactory - The shower appears to drain at an acceptable rate. Urinal: Satisfactory - the urinal appears to be in satisfactory condition. Page 45 Inspection of 31 Uttoxeter Road, Victoria on Managers Suite Unit/Suite: Location: 2nd floor at the rear of the reception area. Living Room: Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Action Necessary - There is at least one broken window pane and the hardware requires adjusting. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Kitchen: Interior Entry Door: Satisfactory - The entry door to the kitchen is as expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Attention Needed - There is evidence of an unrepaired stain on the ceiling caused by a prior moisture leak. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Action Necessary - There is at least one broken window pane and the hardware requires adjusting. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Countertops: Satisfactory - The countertops in the kitchen are satisfactory. Cabinets, Drawers, and Doors: Satisfactory - The cabinets, doors, and drawers are functional. Faucet and Supply Lines: Satisfactory - Faucets and supply lines appear satisfactory with no leaks noted. Sink and Drain Lines: Action Necessary - there is evidence of leakage in the trap or the waste line. Range Hood: None. Master Bedroom: Comment: Occupied - not inspected. Page 46 Inspection of 31 Uttoxeter Road, Victoria on UNIT 105 Open Plan Area (front section of the unit): Front Entry Door: Satisfactory - The main entry door to the structure is in functional condition. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary - some of the suspended ceiling tiles are either missing or damaged. Floor: Action Necessary - Sections of the floor, mainly the rear portion, slope significantly (approx 1 inch in every 3 feet). Windows: Satisfactory - The window(s) in this room appear to be satisfactory. Electrical Outlets: Action Necessary - At least one outlet in the room needs a new cover. Light and Light Switch. Action Necessary - some light diffusers were missing. Room (1st on right from front): Entry Door: Satisfactory - The entry door to this room is functional. Walls: Attention Needed there are sections of mirrored glass leaning down from the wall, these are held in place by drawing pins. Recommend removing from a safety perspective. Attention Needed - the internal walls to this room have been poorly framed and drywalled. Inspection of 31 Uttoxeter Road, Victoria on Page 47 Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Attention Needed - Several light diffusers are either missing or damaged. Room (2nd on right from front) Entry Door: Attention Needed The entry doors to this room have been poorly installed. Walls: Attention Needed - the internal walls to this room have been poorly framed and drywalled. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Heat Source Noted: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Action Necessary - a sink had been removed from this room and the plumbing hasn't been capped off. Inspection of 31 Uttoxeter Road, Victoria on Comment: Action Necessary where the sink had been removed exposed framing was visible. I noted that there was rot in the ends of the joists. Laundry Walls: Action Necessary - the walls are poorly framed and sections are unfinished. Ceiling: Action Necessary - sections are damaged. Floor: Action Necessary sections of the floor are rotten and sloping. Page 48 Inspection of 31 Uttoxeter Road, Victoria on Page 49 Windows: Action Necessary - One or more of the sash cords is broken or missing. The windows have been painted shut and one has been adapted to accommodate the dryer vent. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Dryer Ventilation: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Action Necessary - The dryer vent ductwork is in poor condition. Office (1st on left from front): Entry Door: Attention Needed - The entry door or hardware needs some adjustment or repair for it to function appropriately. Walls: Action Necessary - the walls are patched. Inspection of 31 Uttoxeter Road, Victoria on Page 50 Ceiling: Action Necessary - the ceiling has missing tiles. Floor: Action Necessary - the floor is sloping and has separated from the baseboard. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Inspection of 31 Uttoxeter Road, Victoria on Ceiling Void : Comment: Action Necessary - I noted holes in the lath and plaster ceiling. Comment: Action Necessary - I noted exposed electrical junction boxes. Comment: Action Necessary Staining was noted on the walls and ceiling above the rear section of this unit. The staining could be mould. Page 51 Inspection of 31 Uttoxeter Road, Victoria on Comment: Another photograph showing the staining. Comment: Action Necessary - I noted insulation in the what appears to be a former lightwell which was wet and appeared to have mould growth. Comment: Action Necessary - I noted sections of what appeared to be redundant pieces of ductwork. Page 52 Inspection of 31 Uttoxeter Road, Victoria on Page 53 Washroom (2nd on right from the rear): Entry Door: Satisfactory - The entry door to the bathroom is as expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary water staining was noted. Floor: Satisfactory - The floor in this room is in satisfactory condition. Ventilation Fans: Satisfactory - There is an exhaust fan installed in this bathroom, and it is performing satisfactorily. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Vanity Cabinet: Satisfactory - The vanity cabinet and top in this bathroom are satisfactory. Basin and Drain Fixture: Satisfactory - The basin and drainage fixture appears to be satisfactory. Faucet and Supply Lines: Satisfactory - Faucets and supply lines appear satisfactory. Toilet Condition Satisfactory - The toilet in this bathroom appears to be functional. Washroom (rear right hand corner): Entry Door: Satisfactory - The entry door to the bathroom is as expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Ventilation Fans: None - There is no exhaust fan or window in this bathroom. Current building standards require either an exhaust fan or window for ventilation. Consideration should be given to installation of either. Windows: Action Necessary - The window has been boarded over and it is also poorly trimmed off on the inside. Inspection of 31 Uttoxeter Road, Victoria on Light and Light Switch. Page 54 Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Vanity Cabinet: Satisfactory - The vanity cabinet and top in this bathroom are satisfactory. Basin and Drain Fixture: Satisfactory - The basin and drainage fixture appears to be satisfactory. Faucet and Supply Lines: Satisfactory - Faucets and supply lines appear satisfactory. Toilet Condition Satisfactory - The toilet in this bathroom appears to be functional. Page 55 Inspection of 31 Uttoxeter Road, Victoria on UNIT 107 Front Reception and Hallway: Front Entry Door: Satisfactory - The main entry door to the structure is in functional condition. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging and some tiles are water stained. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Office (front middle): Entry Door: Satisfactory - The entry door to this room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Satisfactory - The window(s) in this room appear to be satisfactory. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Office (front left): Entry Door: Satisfactory - The entry door to this room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging and some tiles are water stained. Floor: Satisfactory - The floor in this room is in satisfactory condition. Windows: Satisfactory - The window(s) in this room appear to be satisfactory. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Kitchen: Interior Entry Door: Satisfactory - The entry door to the kitchen is as expected, and it is functional. Inspection of 31 Uttoxeter Road, Victoria on Page 56 Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging. Floor: Satisfactory - The floor in this room is in satisfactory condition. Light and Light Switch. Attention Needed - the light diffuser is missing. Countertops: Satisfactory - The countertops in the kitchen are satisfactory. Cabinets, Drawers, and Doors: Satisfactory - The cabinets, doors, and drawers are functional. Faucet and Supply Lines: Satisfactory - Faucets and supply lines appear satisfactory with no leaks noted. Sink and Drain Lines: Satisfactory - The sink and drainage lines appear to be satisfactory. Comms Room (left side 2nd from front): Entry Door: Satisfactory - The entry door to this room is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Office (left side 3rd from front): Entry Door: Satisfactory - The entry door on the master bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary sections of the suspended ceiling are sagging and some tiles are water stained. Inspection of 31 Uttoxeter Road, Victoria on Page 57 Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Action Necessary - a light diffuser is broken. Office (left side 4th from front): Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging and some tiles are water stained. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Office (left rear corner): Outside Entry Door: The outside entry door is satisfactory. Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary sections of the suspended ceiling are sagging and some tiles are water damaged. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Inspection of 31 Uttoxeter Road, Victoria on Page 58 Office (right side 1st from front): Entry Door: Action Necessary - the hardware is missing off the sliding door leading to the reception area. Walls: Attention Needed There is some minor damage to the wall surface. Ceiling: Action Necessary -sections of the suspended ceiling are sagging and some tiles are water stained. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Office (right side 2nd from front): Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging and some tiles are water stained. Inspection of 31 Uttoxeter Road, Victoria on Page 59 Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Office (right side 3rd from front): Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging and some tiles are water damaged. Floor: Satisfactory - The floor in this room is in satisfactory condition. Electrical Outlets: Satisfactory - The outlets tested in this room are correctly wired and grounded. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Store: (right side 4th from front): Entry Door: Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging. Floor: Satisfactory - The floor in this room is in satisfactory condition. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Office (rear right corner): Outside Entry Door: The outside entry door is satisfactory. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary sections of the suspended ceiling are sagging and some tiles are water stained. Inspection of 31 Uttoxeter Road, Victoria on Page 60 Floor: Action Necessary - I noted a significant sag/ dip in the floor adjacent to the rear door. Electrical Outlets: Action Necessary - At least one outlet tested in this room is not working. Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Void Above the Suspended Ceiling: Comment: Action Necessary - I noted holes in the lath and plaster ceiling above the suspended ceiling. Inspection of 31 Uttoxeter Road, Victoria on Comment: Action Necessary - I noted galvanized steel piping above some of the water stained ceilings. This is the likely cause of the water staining. Satisfactory - The entry door to this bedroom is as I expected, and it is functional. Comment: Action Necessary - I noted exposed wires not in junction boxes. Comment: Action Necessary - I noted junction boxes with their covers missing. Page 61 Inspection of 31 Uttoxeter Road, Victoria on Comment: Attention Needed The wall infill around the rear fresh air intake grilles is poor. eg no framing members, no insulation etc. Comment: Action Necessary sections of the floor joists above are rotten, I also noted a section of framing hanging down (supported by the piping below the ceiling!) Page 62 Mens Washroom: Entry Door: Satisfactory - The entry door to the bathroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Satisfactory - The ceiling is functional and as expected. Floor: Satisfactory - The floor in this room is in satisfactory condition. Ventilation Fans: Satisfactory - There is an exhaust fan installed in this bathroom, and it is performing satisfactorily. Electrical Outlets: Satisfactory - The outlet in the bathroom is correctly GFCI protected. Light and Light Switch. Vanity Cabinet: Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Satisfactory - The vanity in this bathroom is satisfactory. Inspection of 31 Uttoxeter Road, Victoria on Page 63 Basin and Drain Fixture: Satisfactory - The basin and drainage fixture appears to be satisfactory. Faucet and Supply Lines: Satisfactory - Faucets and supply lines appear satisfactory. Toilet Condition: Satisfactory - The toilet appears to be functional. Cubicles: Satisfactory - the cubical walls, doors and hardware were in functional condition. Urinals: Satisfactory - the urinal and flushing system were in functional condition. Ladies Washroom: Entry Door: Satisfactory - The entry door to the bathroom is as I expected, and it is functional. Walls: Satisfactory - The walls in this room appear to be satisfactory. Ceiling: Action Necessary -sections of the suspended ceiling are sagging. Floor: Satisfactory - The floor in this room is in satisfactory condition. Ventilation Fans: Action Necessary - There is an exhaust fan installed, but it would not activate using normal controls. Electrical Outlets: Action Necessary - The GFCI electrical outlet was miswired (open neutral). Light and Light Switch. Satisfactory - The light(s) and switch(es) were functional at the time of the inspection. Vanity Cabinet: Attention Needed - The vanity counter top surface is delaminating. Basin and Drain Fixture: Satisfactory - The basin and drainage fixture appears to be satisfactory. Faucet and Supply Lines: Satisfactory - Faucets and supply lines appear satisfactory. Toilet Condition: Satisfactory - The toilets appears to be functional. Cubicles: Action Necessary - the hardware is damaged on one cubical door.
© Copyright 2026 Paperzz