Parameterlist Digital Governor System DGS 8800 & DGS 8800e for MAN B&W MC engines AO-20064-A 1 Parameterlist Document history Rev. A AOE-015794 The information contained in this document is subject to change without prior notice. Kongsberg Maritime AS shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this document. © 2003 Kongsberg Maritime AS. All rights reserved. No part of this work covered by the copyright hereon may be reproduced or otherwise copied without prior permission from Kongsberg Maritime AS. Kongsberg Maritime AS Bekkajordet P.O.Box 1009 N-3194 Horten, Norway Telephone: +47 33 03 20 00 Telefax: +47 85 02 80 28 www.kongsberg.com TABLE OF CONTENTS Section Page DISPLAY OF OPCODES. .................................................................................................................................. 5 ADJUSTING OF OPCODES: .............................................................................................................................. 5 HARDWARE & SOFTWARE CONFIGURATION .................................................................................................. 6 PLANT INFORMATION ............................................................................ ERROR! BOOKMARK NOT DEFINED. REGULATOR: USER PARAMETERS; ................................................................................................ 7 REGULATOR - OPCODE 0 - USER 1 PARAMETERS ........................................................................................... 7 REGULATOR - OPCODE 0 - USER 2 PARAMETERS .......................................................................................... 7 AO-20064-A 2 Parameterlist REGULATOR: BASIC PARAMETERS; .............................................................................................. 8 REGULATOR - OPCODE 1 BASIC PARAMETERS .......................................................................................... 8 ENGINE DATA ................................................................................................................................................ 8 REGULATOR - OPCODE 1 BASIC PARAMETERS .......................................................................................... 9 FUEL START SETPOINT .................................................................................................................................... 9 SPEED START SETPOINT .................................................................................................................................. 9 SYSTEM SETTINGS ........................................................................................................................................... 9 ELECTRIC ACTUATOR ..................................................................................................................................... 9 REGULATOR - OPCODE 2 (I/O ADJUSTMENTS) BASIC PARAMETERS .......................................................... 10 REGULATOR: EXPERT PARAMETERS; ........................................................................................ 11 RPM COMMAND LIMITERS ........................................................................................................................... 12 RPM COMMAND ACCELERATION FILTER, DIAGRAM & PARAMETERS. ............................................................ 12 CRITICAL RPM AREAS (BARRED SPEED RANGE) ............................................................................................. 12 MEASURED RPM.......................................................................................................................................... 13 NOTCH FILTER ............................................................................................................................................. 13 START DETECTION SPEED (SULZER ONLY) ...................................................................................................... 13 D-GAIN........................................................................................................................................................ 14 REGULATOR CONTROL ................................................................................................................................. 14 P/I-GAIN...................................................................................................................................................... 14 LDG FUNCTION (LOAD DEPENDENT GAIN) .................................................................................................. 14 CPP SETTINGS (CONTROLLABLE PITCH PROPELLER) .................................................................................... 14 FUEL SETPOINT ADJUSTMENTS (REGULATOR BYPASS) ................................................................................... 15 FUEL LIMITERS ............................................................................................................................................ 15 TORQUE FUEL LIMIT (MAN B&W) ............................................................................................................... 15 SCAVENGE AIR FUEL LIMIT (MAN B&W) ..................................................................................................... 16 ACTUATOR TYPE........................................................................................................................................... 17 ELECTRIC ACTUATOR ................................................................................................................................... 17 LCDL FUNCTION (LOAD CHANGE DEPENDENT LUBRICATION )..................................................................... 17 VIT FUNCTION (VARIABLE INJECTION TIMING) ............................................................................................. 18 CONSTANT FUEL MODE................................................................................................................................ 19 MISCELLANEOUS .......................................................................................................................................... 19 K4 ALARM RELAY ......................................................................................................................................... 19 NON-LINEAR COMPENSATION, DUE TO FUEL PUMP POSITION ...................................................................... 20 SG FUNCTION (SHAFT GENERATOR) ............................................................................................................. 20 NON-LINEAR COMPENSATION, DUE TO LOW RPM ........................................................................................ 21 NON LINEAR PEAK ABILITY. ........................................................................................................................... 21 QPT FUNCTION (QUICK PASS THROUGH BARRED SPEED FOR CPP SYSTEMS) ................................................ 22 DISPLAY DECIMAL POINT POSITION. .............................................................................................................. 22 SELECTABLE OUTPUT SOURCE, FOR PPI PORT 2PC.................................................................................... 23 OUTPUT SOURCE, SELECTION TABLE (NR.0-31) FOR PPI PORT 2PC........................................................... 23 DIGITAL OUTPUT "OR" FUNCTION ................................................................................................................ 24 ANALOG OUTPUT PARAMETERS ..................................................................................................................... 25 CCO - CYLINDER CUT OUT FUNCTION ..................................................................................................... 28 SPECIAL TEST PARAMETERS........................................................................................................................... 29 SULZER ENGINE DATA .................................................................................................................................. 30 PNEUMATIC ACTUATOR TYPE B: LIST OF PARAMETERS ..................................................... 31 ELECTRIC ACTUATOR: USER PARAMETERS; ........................................................................... 33 ELECTRIC ACTUATOR: BASIC PARAMETERS; ......................................................................... 33 ELECTRIC ACTUATOR: EXPERT PARAMETERS; ..................................................................... 34 GERERAL INFORMATION, REGULATOR. ...................................................................................................... 37 GERERAL INFORMATION, ACTUATOR. ........................................................................................................ 37 SYSTEM IN TEST, REGULATOR. .................................................................................................................... 37 AO-20064-A 3 Parameterlist ALARM CODES, REGULATOR. ...................................................................................................................... 38 ALARM CODES, ACTUATOR. ........................................................................................................................ 39 AO-20064-A 4 Parameterlist Display of OpCodes. OpCode 0 1 13 14 OpCode 1,3,4,5,6 1 USER parameters Par. ch BASIC parameters BASIC BASIC parameters OpCode 2 Expert parameters Expert parameters 1 I/O Basic par. parameters 2 . . . 31 32 Adjusting of OpCodes: 1. Set the Service-Code. Switch "Change Lock Key" to Open and set "Service-code" to correct value. 2. Change OpCode. The OpCode will be displayed when the Change Lock Key is switched to Lock position. Select OpCode as required. To adjust parameters switch "Change Lock Key" to Open position. 3. Reset Service-Code. When all adjustments is ready, set the "Service-Code" to 0. Save adjusted values by pushing the save push-button. Switch the "Change Lock Key" to closed and remove the Key. (Keep the Key in the chief engineer office). CAUTION ! Adjusting of values in OpCode 1 and 2 may cause damage to engine and should be done by authorized personnel ONLY ! Parameter description is included in instruction manual Note 1: To be able to display parameters with higher number than 10, the Change Lock Key must be set in "OPEN" position. AO-20064-A 5 Parameterlist Hardware & Software Configuration Electronic unit: DGU-8800 Hardware Elact: 001 configuration: Actuator: Serial No.: 2317 Regulator side: Version: Software configuration: Actuator side: Version: SW-20112-B1. c SW-20124-A8 Engine Maker: Engine type: AO-20064-A Serial No.: 2307 HHI-EMD 6S50MC-C 6 Parameterlist Параметры выделеные красным, реальные уставки сохраненные в память!!! Regulator: USER Parameters; Regulator - OpCode 0 - USER 1 Parameters Parameter name / description: OPEN PARAMETERS Limits Unit Default Min/Max: type: setting: 06 Readable: Readable: Readable: Readable: Readable: Manual RPM limit Mode select RPM command Measured RPM on engine General information, (selected on parameter 14). Scavenge air pressure RPM 0 - 280 103 120 07 Manual fuel limit 08 RPM deadband 09 10 Information: Information: Par. no.: 01 02 03 04 05 0 - 150 0 - 15 Pump index RPM Commission setting: 100 80 2 2 Remarks/ reference: 1 0.0 0.0 See page 37 0.00 Auto-R Auto-F Other status. Other alarm /Reset "old-alarm" with parameter 16 or 17. Normal Regulator - OpCode 0 - USER 2 Parameters "CHANGE KEY" - PROTECTED - PARAMETERS 11 12 Readable: Readable: Alarm nr Alarm Text 13 14 Adjustable VIT OFFSET ADJUSTMENT : 18 Select data to (par.4) See page 37 Readable Information: (no save) Information: (no save) Readable 19 Readable 20 Set/Reset (no save) adjust (no save) 15 16 17 21 Normal Normal nr. 0 1 Ref. separate list ID of Lowest Fuel Limiter 5 RPM detector fail", "Out data error" & "Low Voltage" Reset with "UP" button " (ref. Instruction Manual. Chapter 3) 00 "In data error" (Analog inputs channels 19, 18, 19, 20 & 21) Reset with "UP" button (ref. Instruction Manual, Chapter. 3) 00 Sw version, 20112-B1C Information "System In Test" 00 information Fixed fuel Mode, (useful for taking diagrams on engine) 0 Auto reset outside 50-105% RpmMCR. 0=normal, 1=Fixed Fuel Fixed fuel Level, (useful for taking diagrams on engine) Intended for fine adjusting of fuel level. 0.0 Service Code 99 adjustable AO-20064-A Service Code : “47” 7 Parameterlist Regulator: BASIC Parameters; Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: BASIC Parameters Default setting: Commission setting: Remarks/ reference: Engine Data 1 Engine Maker 2 Number of teeth on flywheel 3 Number of cylinders 4 6 Engine Power at MCR Engine Speed at MCR Inertia (total) 7 Pe, at MCR 8 PSC, at MCR Scav. air pressure Servo Actuator pos. at MCR Pump Index pos. at (MCR) Pump Index pos. at Offset, 5 9 10 11 Sum of rotating masses Mean effective pressure AO-20064-A MAN B&W text MAN B&W 1 - 500 Pcs. 60 117 1 - 12 Pcs. 6 6 0.1 - 100 Mega Watt RPM 5.00 9.47 Hp * 736W 100.0 127 RPM at max cont. rating 10 - 280 1 - 2000 1000 Kg m² 80.0 82.2 10 - 30 Bar 17.0 20 0.1 - 4 Bar 2.00 2.72 0 - 100.0 mm 100.0 86.5 0 - 150.0 Pump Index Pump Index 100.0 73.0 0.0 13 0 - 50.0 8 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: BASIC Parameters Default setting: Commission setting: Remarks/ reference: Fuel start setpoint 12 13 14 Normal start, Fuel setpoint Heavy start, Fuel setpoint Start extension time 0 - 100 0 - 100 0 -30 Pump index Pump index 30 40 50 55 Sec. 10.0 10.0 Speed start setpoint 15 16 Speed start setpoint Rpm level. Speed start setpoint Time delay 0 - 280 Rpm 62 45 0 - 10 Sec. 6 6 System Settings 17 и 61 неменять. Сбиваются настройки!!! 17 Set Rpm-Levels from Engine Data 53 CPP VERSION 61 Set Fuel-Limiters from Engine Data rPMLIM / Auto-r CPP / F-Reg FUELIM / Auto-F text rPMLIM text F-Reg text FUELIM Auto setting of Speed Levels Parameters marked “Auto-R” Auto setting of fuel limiters. Parameters marked “Auto-F” Electric Actuator 77 Actuator Type 78 El. Actuator Arm 79 El. Actuator Gear Ratio AO-20064-A Pn-Saa EL.Act text ELACT ELACT 1-320.00 mm 140.00 140.00 0-1000 ratio 89 89 9 Parameterlist See page 11!!! Regulator - OpCode 2 Signal chan 1* Ext. Stop, SHD form SSU Stop 2 (Br. Contr.) (or QPT ) QPT active (if QPT function = true) Not Go 2 (Br. Ctrl.) 2* 3* 4 5 6* 7* 8* 9 10 10 11 (Actuator; Servo Brake Off) (Actuator; Position Speed Cmd) (Actuator; Reset Servo Amplifier) (Actuator; Servo ampl.Fail) (Actuator; Manual) 12 13 14 15 16 (Actuator; Torque Enable)* Analog Channels Error Low Error High Count Zero Count Low Count High tec. Low tec. High Limit Low Limit High Filter const. 0-4095 0 or CL-CH 1 - CH CL - 4095 +/+/+/+ 300.00 300.00 300.00 300.00 0-60.0 sec. EL EH CO CL CH tL tH LL LH tF (I/O adjustments) BASIC Parameters Type Inverted Pass d-out Pass Pass d-in d-out A-out d-out d-in d-in see special backwiring see special backwiring see special backwiring see special backwiring see special backwiring see special backwiring Non-Adjustable; Only ELACT see special backwiring Or = d= Or = d= Or = d= Or = d= pass pass pass pass pass Non-Adjustable; act D-Out Non-Adjustable; act A-Out Non-Adjustable; act D-Out Non-Adjustable; act D-In Non-Adjustable; act D-In d-in d-in On delay 17 18 Rpm Cmd Rpm Cmd 19 Pitch C. Room Bridge feedback 200 1750 0 611 1656 25 131 23 133 1.5 2350 4000 0 2430 3927 25 131 23 133 1.5 Off delay nn 801.3 d2 = d2 = d2 = d2 = nn 801.3 nn 803.4 nn 801.3 nn 801.1 nn 801.1 20 Scav. Air Pres. 0 0-4095 2350 4095 4000 2000 0 1000 2430 3000 3910 -1.00 0.0 1.00 4.0 1.00 0.0 1.00 4.0 0.0 5.0 21 not used 0 4095 0 50 2000 2.0 103 0 0 0 Signal Stop 1 (Ctrl. Room) Not Go 1 (Ctrl. Room) Passive Cmd Select (Bridge) BridgeControl, Power Fail Fixed Speed Slow Down Cancel Lim. (Bridge,+) Rpm Pickup A Rpm Pickup B chan Type Inverted On delay Off delay 22 d-in Or = d= D2 = 23 d-in Or = d= D2 = 24* d-in Or = d= D2 = 25 d-in Or = true d= D2 = 26 d-in Or = d= D2 = 27 d-in Or = d= d2 = 28 d-in Or = d= d2 = 29 d-in Or = d= d2 = Lop Fail Input (d-in) 30 F-in Or = Lop Fail Input (d-in) 31 F-in Or = 32* d-in Or = d= d2 = Note 1. For channel type d-in => "Or"=false, d and d2 = 0.0, unless otherwise specified. Note 2. * => Special backwiring is required, for this channel! See special backwiring. End of Basic Parameters. AO-20064-A 10 Parameterlist ty d1 In Or d d2 Si Su 5 d-in open open false 0 0 false open 9 d-in open close true 0 0 false close 10 d-in close close false 0 0 false close 11 d-in close close false 0 0 false close 22 d-in close close false 0 0 false close 23 d-in close close false 0 0 false close 24 d-in open close true 0 0 false close 25 d-in open close true 0 0 false close 26 d-in close close false 0 0 false close 27 d-in open close true 0 0 false close 28 d-in open close true 0 0 false close 29 d-in open close true 0 0 false close 30 31 32 F-in F-in d-in close close open close close close false false true 0 0 false false false close close close Analog channel ty AC A1 LF EL EH CO CL CH tL tH LL LH tF AO-20064-A 17 A-in 236 23 normal 200 1750 0 611 1656 25 131 23 133 1.5 18 A-in 2713 45.00 normal 2350 4000 0 2430 2927 25 131 23 133 1.5 19 A-in 0 1.00 normal 0 4095 2000 1000 3000 -1.00 1.00 1.00 1.00 0.0 20 A-in 2430 0.00 normal 2350 4000 0 2430 3910 0.00 4.00 0.00 4.00 5.0 21 A-in 0 0.00 normal 0 4095 0 50 2000 2.00 103.00 0.00 0.00 0.0 11 Parameterlist Regulator: EXPERT Parameters; Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Auto-R (40%) RPM Command Limiters 18 Slow down level 19 Fixed speed 0 - 280 RPM 40.0 64 20 - 280 RPM 75.0 75.0 RPM Command Acceleration Filter, Diagram & Parameters. Rpm B C Change level A 20 Change level. 21 D Seconds. 0 - 280 RPM 75 95 A) Pos. low lev. rate 0.5 - 1000 200.0 200.0 22 B) Pos. hi. lev. rate 0.5 - 1000 2.0 2.0 23 C) Neg. hi. lev. rate 0.5 - 1000 2.0 2.0 24 D) Neg. low lev. rate 0.5 -1000 RPM /sec. RPM /sec. RPM /sec. RPM /sec. 1.0 2.0 Auto-R (75%) Critical RPM Areas (barred speed range) 25 26 27 28 29 Critical RPM. Low RPM level 1 Critical RPM. High RPM level 1 Critical RPM. Low RPM level 2 Critical RPM. High RPM level 2 0 - 280 RPM 40 50 0 - 280 RPM 40 61 0 - 280 RPM 70 70 0 - 280 RPM 70 70 Max. speed at cancel limiters 0 - 280 RPM 110 133 AO-20064-A Auto-R (105.0 %) 12 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Measured RPM 30 31 32 33 Rpm Detector Warning Delay Max Rpm Variation Filter Low Pass Filter Measured RPM low pass filter 0 - 2.50 Sec. 0.50 0.9 0 - 280 RPM /20ms e 4 4 0.70 0.70 0.50-0.80 Display Filter (for parameter 3 only) e 0 - 0.99 0.99 0.99 Notch Filter 34 35 Notch Function 36 Filter Connect Hysterese Filter Disconnect Hysterese 37 Filter max. RPM (0-1) 0 - 280 text RPM no Flt 50 no Flt 50 0 - 50 RPM 2 2 0 - 50 RPM 6 6 Start detection speed (Sulzer only) 38 39 Start detection speed for Remote Start detection speed Backup and Local AO-20064-A (0-20) rpm 0 0 (0-20) rpm 6 6 13 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: D-Gain 40 41 42 43 D-Gain Function enabled D-Gain Function in “normal sea” also Filter of RPM used in D- gain function. D-Gain factor True/False text False False True/False text False False 1-7 samp. 20 ms 3 3 0 - 10.00 K 0.10 0.10 Moving avg. Filter Regulator Control 44 Cmd forward gain 45 Reduction gain 0 - 10.00 X 1.00 1.00 1 - 20 1/K 5 5 In deadband P/I-Gain 46 Rough sea P-Gain 0.1 - 10 X 0.90 0.9 47 Rough sea I Gain 0.1 - 10 Time const. 3.00 3.00 48 Normal P-Gain 0.1 - 10 X 1.00 1.00 49 Normal I-Gain 0.1 - 10 Time const. 1.00 1.00 LDG Function (Load Dependent Gain) 50 LDG Function True/False text False False 51 Idle Offset load 0-80 % 20 20 52 LDG - Gain 0-10.00 rel. 1.00 1.00 0.00 equals Function OFF CPP Settings (Controllable Pitch Propeller) 53 CPP VERSION 54 Min. Pitch used for Pitch forward gain. Min. Pitch used for Igain and Fuel Lim. Zero Pitch Fuel Limiter Level. 55 56 AO-20064-A CPP / F-Reg text F-Reg 0 - 1.00 rel 0.30 0 - 1.00 rel 0.50 0 - 150 Pump index 30 Cpp Version Only Cpp Version Only Cpp Version Only 14 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Fuel Setpoint Adjustments (Regulator bypass) 58 Fuel Setpoint Function enabled. Handle zero fuel. 59 Handle 100% fuel. 57 RPM Cmd when 0% fuel RPM Cmd when 100% fuel true/false text False False CCO function must be passive 0 - 280 RPM 20 32 0 - 280 RPM 90 120 Auto-R (25%) Auto-R (95%) Fuel Limiters 60 61 62 Raise Fuel Limiter internally Set Fuel-Limiters from Engine Data Raise Fuel Limiter at cancel limiters 0-30 % 0.0 automatic setting Text 0-110 % FUELIM 0.0 Ref. CPP Loadcontroler Auto set the Scav. air, Torque and Manual fuel limiters !! 10 10 at Cancel lim. Signal Torque Fuel Limit (MAN B&W) 63 Torque RPM 2 0 - 281 RPM 70.0 53 Auto-F 64 Torque RPM 3 0 - 282 RPM 96.0 117 Auto-F 65 Torque RPM 4 0 - 283 RPM 105.0 127 Auto-F 66 Torque RPM 5 0 - 284 RPM 107.0 130.8 Auto-F 67 Torque range 1,2 0 - 100 % 100.0 60.2 Auto-F 68 Torque range 3,4 0 - 100 % 100.0 100.0 Auto-F 69 Torque range 5,6 0 - 100 % 100.0 100.0 Auto-F (Overspeed start) (Overspeed Zero Fuel) (Overspeed- ZERO FUEL) % Fuel Torque Limiter 100% 1 0.0 AO-20064-A 3 4 5 6 2 MC R speed (rpm) 15 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Scavenge Air Fuel Limit (MAN B&W) 70 Scav.air press 2 0 - 4.01 Bar 0.00 0.00 Auto-F 71 Scav.air press 3 0 - 4.02 Bar 1.00 0.5 Auto-F 72 Scav.air press 4 0 - 4.03 Bar 1.40 2.30 Auto-F 73 Scav.air range 1,2 0 - 100 % 100.0 60.2 Auto-F 74 Scav. air range 3 0 - 100 % 100.0 68.4 Auto-F 75 Scav. air range 4,5 0 - 100 % 100.0 don't care Fixed @ 100 % Scavenge Air Limiter % Fuel 100% 4 5 3 1 0.0 2 Pscav (Bar) The fuel limiters set in the governor is transferred to “cpp load controller” and the governor is using 10% higher limites (adjustable in parameter 1.60). AO-20064-A 16 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default Setting: Commission setting: Remarks/ reference: Pump Index See page 37 Actuator Type 76 77 Actuator Display Show value select Actuator Type (0-4) Text Load % Pn-Saa EL-Act Text EL-Act Electric Actuator 78 El. Actuator Arm 1-320.00 mm 140.00 140 79 0-1000 ratio 89 89 80 El. Actuator Gear Ratio Enable new Scale, text Sc Dis Sc Dis 81 Make new scale (Sc.) text Scale Scale 82 (Fuelrack / Actuator) Disable / Enable Scale, Set Scale No save. Auto reset. No save. Auto reset Blank LCDL Function (Load Change Dependent Lubrication ) 83 84 85 86 LCD controlled by telegraph lever Load change filter (Tr) Extra lubrication action level (Ir Extra lubrication off delay (ts) AO-20064-A else by fuel command true/false Text True True 2 - 120 Sec. 10.0 10.0 0.05- 0.25 Rel. 0.10 0.10 Relative fuel 15 - 60 Min. 30.0 30.0 Minutes 17 Parameterlist Regulator - OpCode 1 Par. no.: Expert Parameters Parameter name / Limits Unit Default Commission description: Min/Max: type: setting: setting: VIT Function (Variable Injection Timing) 87 V.I.T. Function On true/false Text false False 88 Pmax, 100 - 250 Bar 140 140 89 Pmax, allowed pressure 0 - 50 Bar 35 35 25.0-50.0 Bar 35.0* 35.0 0.5 - 0.95 0.85* 0.85 0.20 0.20 10-50 rel. load rel. load Bar 35* 35 0 - 25 Bar 15* 15 + - 50 Bar 15* 15 Max. press. in cylinder Remarks/ reference: rise from Pcomp to Pmax 90 kc, Ratio of 91 Pk, Power at breakpoint 92 Pmin, Min. Power, 93 Pk, Pcomp relative to Psc (rel. meas. unit) curve III. (rel. meas. unit) 0 - 0.60 Press. raise at breakpoint 94 Pmcr, Press. rise at MCR 95 Pmin, = Pmcr Min. value of press. rise 96 ki, Output conv. factor 0 - 2.000 mA/ Bar 0.350 0.350 97 Pmax, control, 0 - 20 Bar 10 10 + - 50 Bar 0 0 0.2 - 120 sec. 30.0 30.0 0.2 - 120 sec. 1.0 1.0 from p to 4-20mA Max.allowed control range 98 99-A0 Poffset, Adjustment for Pmax. level Blank A1 Increase, max rate A2 Decrease, max rate From 4 to 20 mA From 20 to 4 mA. Pmax. Lim. (if press sensor fail) Adjustment for fuel quality * Calculated engine dependent data. (May have to be adjusted for actual testbed data). Readable values for V.I.T. - Note: OpCode 0 !!! 0-84 0-85 0-86 Readable Readable Readable 0-87 0-88 0- 89 0-90 0-91 0-92 0-93 0-94 0-95 0-96 Readable Readable Readable Readable Readable Readable Readable Readable Readable Readable 0-97 0-98 Adjustable Adjustable AO-20064-A V.I.T. (Variable Injection Timing) Internal signals rel engine speed. (0 - 1.0) rel fuel pump index. (0 - 1.0) Scav. air pressure (abs Bar) V.I.T. (Variable Injection Timing) Calculations Range 1 p, I Range 2 p, II Range 3 p, III Range 4 p, IV Range 5 p, V Range Selected Range (1-5) selected pressure rise p Pcomp = kc * Psc, Compression pressure in cylinder. I 4-20 mA output signal ALARM Operation in Range "V" V.I.T. (Variable Injection Timing) Test output signal Output select "norMAL"= Normal VIT signal. "VitSim"= Simulate output signal. Test signal 4.0 - 20.0 mA simulation signal. nr Ir Psc 18 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Constant Fuel Mode true/false text false true 0-320 sec. 5 5 0-280 Rpm 3 3 Relative to Rpm Cmd 0-280 Rpm 3 3 Relative to Rpm Cmd 0-280 Rpm 8 5 Relative to Rpm Cmd 0-280 Rpm 8 5 Relative to Rpm Cmd AA Constant Fuel Function Timer for engage const. fuel Engage Band Lower Limit Engage Band Upper Limit Disengage Band Lower Limit Disengage Band Upper Limit RPM Lower Limit 0-280 Rpm 30 85 Absolute RPM AB RPM Upper Limit 0-280 Rpm 110 121 Absolute RPM A4 A5 A6 A7 A8 A9 Miscellaneous AC AD AE NotGo/Stop, only one signal Cancel limiters, only one signal Fuel limiter Prewarning Fixed speed location. AF Ch. 27 Fixed speed to be active with location: true/false text False fals true/false text False False 0 - 150 % 0 0 none, Bridge, Ctrl. Room, both text none none Cancel limiter K4 Alarm Relay B0 B1 B2 B3 b4-bf Alarm input filter, Time delay Alarm active, Time delay Alarm passive, Time delay Invert alarm relay, "Or" function 0-10.0 Sec. 1.0 1.0 0-10.0 Sec. 5.0 5.0 0-10.0 Sec. 5.0 5.0 True/False text False False Blank AO-20064-A 19 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Non-Linear Compensation, due to Fuel Pump Position True/ False text false C1 Non Linear Position, Function On x1 0-100.0 % 20.0 20.0 C2 x2 0-100.0 % 25.0 25.0 C3 x3 0-100.0 % 30.0 30.0 C4 x4 0-100.0 % 40.0 40.0 C5 y1 0-100.0 % 20.0 20.0 C6 y2 0-100.0 % 25.0 25.0 C7 y3 0-100.0 % 30.0 30.0 C8 y4 0-100.0 % 40.0 40.0 C0 C9 Blank SG Function (Shaft Generator) CA Shaft generator, Function on/off CB Shaft generator, Basic RPM Shaft generator, Basic timer Shaft gen. available, RPM Band Shaft gen. available, Stabilizing delay CC CD CE CF Off / Sh-GEn 0 - 280 text Off Off RPM 99 99 0 - 250 Sec. 60 60 0 - 280 RPM 5.0 5.0 0 - 250 Sec. 10 10 Relative to fixed speed Delay for output signal Blank AO-20064-A 20 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Non-Linear Compensation, due to Low RPM False/ True text False False D1 Non Linear by Low Rpm, Function On x1 Speed 0-280.0 rpm 20.0 20.0 D2 x2 Speed 0-280.0 rpm 30.0 30.0 D3 x3 Speed 0-280.0 rpm 40.0 40.0 D4 x4 Speed 0-280.0 rpm 50.0 50.0 D5 y1 factor 1.00-2.00 rel. 1.50 1.50 D6 y2 factor 1.00-2.00 rel. 1.20 1.20 D7 y3 factor 1.00-2.00 rel. 1.10 1.10 D8 y4 factor 1.00 rel. 1.00 1.00 D0 Not adjustable Non linear peak ability. D9 Non linear functions able to override fuel limiters da-df Blank AO-20064-A true / false text False False 21 Parameterlist Regulator - OpCode 1 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: QPT Function (Quick Pass Through barred speed for CPP systems) QPT - Shut Down (Quick Pass Through barred speed) E0 QPT - SHD On true / false text False False E1 Barred speed high 0- 280 rpm 50.0 50.0 E2 Barred speed low 0- 280 rpm 40.0 40.0 E3 Barred speed time 0- 60.0 sec. 5.0 5.0 E4 SHD output signal (Output “OR”) true / false text False False SHD signal output to Safety Systen if engine is running too long in barred speed. QPT - Start, Stop & Slow Down (Quick Pass Through barred speed) E5 QPT Function On true / false text False False E6 Barred speed band 0- 280 rpm 4.0 4.0 E7 Idle speed, Level 0- 280 rpm 95.0 95.0 E8 Idle speed, Time 0- 60.0 sec. 5.0 5.0 E9 Zero pitch low index 0- 150 25 25 EA Zero pitch high index 35 35 EB Zero Pitch Level Pump Index Pump Index rel Pitch 0.20 0.20 EC Zero pitch request signal (Output “OR”) False False ed-ef Blank Margin to barred speed Speed cmd, starting engine Extra time for zero pitch Fuel level after slow down. Set fuel level after start. Accepted pitch for passing 0- 150 0- 1.00 true / false text Manual Fuel Limiter Unit ( Load (100%) or Pump Index (mm) ) text true true F0 Scale select (0-1) f1-fd Blank Display decimal point position. FE FF Dcimal point for rpm par. 2 and 3 rPm-d0 rPm-d1 rPm-d2 Blank Not used AO-20064-A text rPm-d0 rPm-d0 change key in “lock” position 22 Parameterlist Regulator - OpCode 3 Expert Parameters Special backwiring table (special channel connection ) Ch. P1-M ch.01 ch.02 ch.03 ch.04 ch.05 ch.06 ch.07 ch.08 ch.21 ch.24 ch.32 P1M-35 P1M-36 P1M-33 P1M-34 P1M-31 P1M-32 P1M-29 P1M-30 P1M-15 P1M-14 P1M-06 Wired to: Normally used as: Actually used as: connection P1R-08 - LCD Lubrication output PIR-10 actuator : Fuel position output actuator: Torque enable output P1R-05 Vit output signal P1R-15 Cancel limiter @ECR input Fixed Output, for PPI Port 2PB (information only) P1R-01 P1R-02 P1R-04 QPT, zero pitch req, Reserved QPT, Critical speed Selectable Output Source, for PPI Port 2PC Par. no.: 05 06 07 08 09 10 11 Parameter name / description: P1R-05 select P1R-06 select P1R-07 select P1R-08 select P1R-09 select P1R-10 select P1R-12 select Limits Min/Max: 0 - 31 0 - 31 0 - 31 0 - 31 0 - 31 0 - 31 0 - 31 Unit type: Default setting: Commission setting: nr nr nr nr nr nr nr 16 7 4 5 2 3 1 16 7 4 5 2 24 1 Remarks/ reference: Output Source, Selection Table (nr.0-31) for PPI Port 2PC nr DIGITAL SIGNAL source [NN-801.3] Remarks nr 0 16 1 Fuel prewarning 17 2 Fuel limiter active 18 3 Start Diesel Generator 19 4 Sh. Gen. Available 20 5 LCD Lubrication 21 6 75% Load 22 7 VIT_Alarm 23 8 CCO group 1 24 9 CCO group 2 25 10-13 26-29 14 30 15 oscilator 3 Hz 31 Note 1. See also analog scaling selection parameter. of signal type. AO-20064-A ANALOG SIGNAL source [varius adaptorcards] Vit out [NN-803.2] 4-20 mA Rpm Cmd ECR (from input ch.17) Rpm Cmd WH (from input ch.18) Rpm Cmd diffrence (wh-Ecr) Rpm Cmd in control (as param.2) Meassured Rpm Max. Available fuel (the fuel limitation) Fuel Margine (limiter-fuelrack diffrence) Actuator position, Fuel output Remarks note 1 note 1 testsignal (range 4-20 mA) testsignal (range +/ -10 Volt) 23 Parameterlist Regulator - OpCode 3 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: False QPT, zero pitch req, Digital output "OR" function 12 13 14 15 16 17 18 19 20 21 Signal 'P1R-01' "Or" function Signal 'P1R-02' "Or" function Signal 'P1R-04' "Or" function Signal 'P1R-05' "Or" function Signal 'P1R-06' "Or" function Signal 'P1R-07' "Or" function Signal 'P1R-08' "Or" function Signal 'P1R-09' "Or" function Signal 'P1R-10' "Or" function Signal 'P1R-12' "Or" function AO-20064-A Digital output from 2PB text False True/False True/False text False False reserved True/False text False False Critical speed Digital output from 2PC True/False text False False selectable True/False text False False selectable True/False text False False selectable True/False text False False selectable True/False text False False selectable True/False text False False selectable True/False text False False selectable 24 Parameterlist Regulator - OpCode 3 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Analog output parameters Analog output select 16 scaling. - not used ( Vit output have fixed scale - reserved parameters only ) 22 Blank Not used 23 Simulation true/false text false False 24 Simulate counts 0 - 4095 count 0 0 25 Count Low 0 - 4095 count 2048 2048 26 Count High 0 - 4095 count 3800 3800 27 Tec. Low 0 - 300 rpm 0.0 0.0 28 Tec. High 0 - 300 rpm 120.0 120.0 Analog output select 17 scaling. - Rpm Cmd (Ctrl.Room), setpoint from i/o ch 17 29 Blank Not used 30 Simulation true/false text false False 31 Simulate counts 0 - 4095 count 0 0 32 Count Low 0 - 4095 count 2450 2450 33 Count High 0 - 4095 count 3800 3800 34 Tec. Low 0 - 300 rpm 0.0 0.0 35 Tec. High 0 - 300 rpm 120.0 120.0 Analog output select 18 scaling. - Rpm Cmd (Bridge.), setpoint from i/o ch 18 36 Blank Not used 37 Simulation true/false text false False 38 Simulate counts 0 - 4095 count 0 0 39 Count Low 0 - 4095 count 2450 2450 40 Count High 0 - 4095 count 3800 3800 41 Tec. Low 0 - 300 rpm 0.0 0.0 42 Tec. High 0 - 300 rpm 120.0 120.0 AO-20064-A 25 Parameterlist Regulator - OpCode 3 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Analog output select 19 scaling. - Command diffrence signal. 43 Blank Not used 44 Simulation true/false text false False 45 Simulate counts 0 - 4095 count 0 0 46 Count Low 0 - 4095 count 0 0 47 Count High 0 - 4095 count 4095 4095 48 Tec. Low / 300 rpm -119.9 -119.9 49 Tec. High / 300 rpm 120.0 120.0 Analog output select 20 scaling. - Rpm Command. 50 Blank Not used 51 Simulation true/false text false False 52 Simulate counts 0 - 4095 count 0 0 53 Count Low 0 - 4095 count 2450 2450 54 Count High 0 - 4095 count 3800 3800 55 Tec. Low 0 - 300 rpm 0.0 0.0 56 Tec. High 0 - 300 rpm 120.0 120.0 Analog output select 21 scaling. - Meassured Rpm. False true/false text 57 Displayfiltered False 58 signal Simulation 59 true/false text false False Simulate counts 0 - 4095 count 0 0 60 Count Low 0 - 4095 count 2048 2048 61 Count High 0 - 4095 count 4095 4095 62 Tec. Low 0 - 300 rpm 0.0 0.0 63 Tec. High 0 - 300 rpm 120.0 120.0 AO-20064-A 26 Parameterlist Regulator - OpCode 3 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Analog output select 22 scaling. - Max Available Fuel 0-110 to “Load Controller”. 64 Blank Not used 65 Simulation true/false text false False 66 Simulate counts 0 - 4095 count 0 0 67 Count Low 0 - 4095 count 2450 2450 68 Count High 0 - 4095 count 3800 3800 69 Tec. Low 0 - 150 0.0 0.0 70 Tec. High 0 - 150 % fuel % fuel 110.0 110.0 Analog output select 23 scaling. - Fuel Margine 110% to “Load Controller”. Ref. CPP False true/false text False Loadcontroller 71 Fuel margine signal 72 restricted to par 1.60 Simulation 73 true/false text false False Simulate counts 0 - 4095 count 0 0 74 Count Low 0 - 4095 count 0 0 75 Count High 0 - 4095 count 4095 4095 76 Tec. Low +/- 150 -109.9 -109.9 77 Tec. High +/- 150 % fuel % fuel 110.0 110.0 Analog output select 24 scaling. - Actuator position 0-100%. 78 Blank Not used 79 Simulation true/false text false False 80 Simulate counts 0 - 4095 count 0 2445 81 Count Low 0 - 4095 count 2430 2443 82 Count High 0 - 4095 count 4095 4095 83 Tec. Low 0 - 150 0.0 0.0 84 Tec. High 0 - 150 % fuel % fuel 100.0 100 AO-20064-A If change this figure Par.80 change to 2445 also 27 Parameterlist Regulator - OpCode 4 Par. no.: Parameter name / description: Limits Min/Max: Expert Parameters Unit type: Default setting: Commission setting: Remarks/ reference: true / false text False False true / false text False False true / false text True True 0- 100 0- 50 0- 50 0- 120 0- 120 0- 120 0- 60 0- 1.00 0- 10 0- 10 rpm rpm rpm 38.0 5.0 5.0 38.0 5.0 5.0 X1 sec. sec. sec. min. sec. 10 10 30 10 0.25 10 10 30 10 0.25 t1 rpm rpm 3.0 5.0 3.0 5.0 H1 CCO - Cylinder Cut Out function 01 CCO Function enabeld NOTE: If this function is enabled then Fuel setpoint function will be disabled. 02 03 04 05 06 07 08 09 10 11 12 13 button protected by Change Lock Key External Remote Control Signal Cut out enable level CCO Cmd above actual rpm Engine stop detection Delay Cut out enable Delay Disable by change cmd Delay Cut out during start Delay Cut out seqense Delay Cut out overlap Hyst. cut out level Hyst. cmd override X2 X3 t2 t3 t4 t5 H2 Readable parameters 0.02 0.03 Rpm Cmd Engine speed rpm rpm 14 15 16 CCO automatic mode. (function param + panel button) * Remot control ( io ch.32) * Engine Low speed enable CCO enable CCO enable CCO true/false true/false true/false 17 18 19 20 * * * * disable CCO disable CCO disable CCO disable CCO true/false true/false true/false true/false 21 22 23 24 * CCO avtive (enabled) LCD Lubricaton blocked by CCO Actuator blocked t4 timer (remaining time, countdown ) Cmd high above engine speed Engine stopped (cmd lever or meassured) Cmd high Limiters cancelled ( io ch.29) stops t4 timer CCO Group 1 active 25 CCO Group 2 active 26 * NOTE: Parameter 14 -20 is only opdated in CCO automatic mode (ref. par.4.13) AO-20064-A true/false true/false true/false min.sec 10.00 true/false true/false 28 Parameterlist Regulator - OpCode 5 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Special test parameters DAC Select (Digital to Analog Converters) nr. 9 9 0- 50 01 Dac 1 select 02 Dac 2 select 0- 50 nr. 12 12 03 Dac 3 select 0- 50 nr. 29 29 04 Dac 4 select 0- 50 nr. 31 31 05 06 Calibrate Timer Simulation Step sec. 6.0 0- 60.0 count 200 0- 5000 6.0 07 Calibrate Step Rpm Cmd Calibrate Step Rpm Measured 0- 5000 count 200 Connector PC-3 200 200 Direct fuel setpoint and oscillator simulation. 09 Function select 0 1 2 3 10 Direct output par. 0-100.00 11 Direct output (ch. 21) 12 Direct output (ch. 21) 13 Oscillator, Curve function 0 1 2 3 14 Oscillator, Frequency Oscillator, Amplitude Oscillator, Center reference 15 16 (or output from ch. 21) Counts Low Counts High AO-20064-A NORMAL Reg. Direct /f. ch. 21 Direct /f. par. Direct /f. oscilla. nr. Normal Normal not savable % 2 2 Only adj. if set to direct from par. 0-4095 count 25 25 0-4095 count 4000 4000 text C-LinE C-Line 0.1 - 5.0 Hz 1.0 1.0 2 - 100 % 80 80 1 - 60 % 40 40 Center line, Sinus wave, Triangle wave, Square wave, 29 Parameterlist Regulator - OpCode 6 Par. no.: Parameter name / description: Limits Min/Max: Unit type: Expert Parameters Default setting: Commission setting: Remarks/ reference: Параметры неменять. Сбиваются предыдущие настройки!!! Sulzer Engine Data 1 P charge air 0.0 - 4 Bar 1.00 0.1 - 4 Bar 2.00 0 - 10.00 Linkage Index 2.00 0 - 10.00 Linkage Index 4.00 0 - 10.00 Linkage Index 8.00 0 -10.00 Linkage Index 10.00 at 50% power 2 3 4 5 6 P charge air at 100% power Fuel Rack position at 25% power Fuel Rack position at 50% power Fuel Rack position at 100% power Linkage Index. max AO-20064-A 30 Parameterlist Pneumatic Actuator type B: List of parameters Actuator type B, List of parameters SAA (Switch Air Actuator) 01 02 03 04 05 06 07 08 09 10 Information: Information: Readable: Readable: Information: Information: Information: Information: Readable: Readable: Sw 20114 (5,8 MHz) Mode select (0-6), not to be adjusted. Actuator fuel command value from regulator (0 - 100.0 mm) Actuator measured position from feedback (0-100.0 mm) Servo error value (± 100.0) Servo dead band (± 100.0), standard set to 0.4, do not adjust. Regulator Show. Value selected in regulator is displayed. Feedback fail. status (reset by up-button) (Hex), std. set to 00. In-data error status (reset by up-button) (Hex), std. set to 00. Other status (no message in this program) Other alarm Actuator type B, List of parameters Par. no.: SAA (Switch Air Actuator) Sw 20114 Parameter name / Limits Unit Default description: Min/Max: type: setting: (5,8 MHz) Commission setting: Remarks/ reference: System 11 12 Systemdate CPU Speed Process. card type SW system date (dd.mm.y), CAUTION, DO NOT RESET! 0 = 5 MHz 1 = 8 MHz no 0-1 1 Adjustment 13 14 15 16 17 18 Number of fine-tuning pulses in auto cal. Fine adj. (-) of pulse width, negative move. Fine adj. (-) of pulse width, positive move. Fine adj. (+) of pulse width, negative move. Fine adj. (+) of pulse width, positive move. Coarse adj. of pulse width, negative move 19 Coarse adj. of pulse width positive move 20 Pulse period 21 High speed gain, negative move. 22 High speed gain, positive move. 23 Low speed gain, negative move. 24 High speed gain, positive move. AO-20064-A 1-10 No 2 0 0 0 0 mSec 4 (auto) 5 mSec 5 mSec 0.25 mm 0.25 mm 0.1 mm 0.1 mm 4 (auto) Autocalibration Autocalibration 6 50 50 50 50 Autocalibration Autocalibration Autocalibration Autocalibration 31 Parameterlist Actuator type B, List of parameters Par. no.: SAA (Switch Air Actuator) Sw 20114 Parameter name / Limits Unit Default description: Min/Max: type: setting: 25 Sub. mode select (Manual calibration) 26 Information: 27 Local cal., high speed min. acceptable value 28 Readable: 29 Calibration center position 30 31 Information: Information: 32 Timing of calibration half period 33 Readable: 34 1B register activity level setting 35 Readable: 36 2C register activity level setting Exclusive alarming 37 38 Delay time of alarming/prewarning 39 Allowed dead-band bef. feedback fail warning 40 Readable: 41 "Too slo" (to slow) alarm function 42 Allowed dead time bef. pulse width adaptation 43 Readable: 44 Display filter constant of parameter 3 Dip-switch setting on panel card 45 (5,8 MHz) Commission setting: 0 Mode select (0-6) not be adjusted. (Same as parameter no. 1). mm/ 200 Sec Local calibration status low (0) or high (1) (Default = 1) mm 50 Upper limit of high speed position control (mm) (Default=98) Lower limit of high speed position control (mm) (Default=2) 5 300 mSec 1B register status (HEX) Hex 21 2C register status (HEX) Hex 0 or 1 on/ off 5 mSec Sec 4F 0 0 = Off 1 = On 50 1.00 Delay timer display for parameter 39 (Sec.) on/ 0 0 or 1 off Sec 1.00 0 = On 1 = Off Delay timer display for parameter 41 (Sec.) 4 Readable only Actuator position, counts value (raw data) (12-1012) Do not adjust. Counts 12 HEX FF 46 Information: 47 Zero offset value (Autozero setting) 48 49 Not used Information: Actuator position unfiltered (0-100 mm) 50 Service code Set to 27 for adjustments, otherwise set to 0. AO-20064-A Remarks/ reference: 32 Parameterlist Electric Actuator: USER Parameters; Electric Actuator, 01 02 03 04 05 06 Information: 07 08 09 10 Resetable: 11 12 Readable: 13 Blank 99 Service code BASIC Parameters Information: Mode select (0-6), not to be adjusted. Actuator fuel command value from regulator Actuator measured position from feedback Servo error value Servo dead band Information: General Information. Value selected in regulator is displayed. Information: Readable: Readable: 1 0.0 0.0 0.0 0.0 Information: 0.0 Feedback fail. status (reset by up-button). In-data error status (reset by up-button). Other Status Information. Alarm (ref. Instruction Manual, Chapter. 3, Trouble Shooting) Resetable: 0.0 0.0 normal Alarm Information Readable: Alarm Nr. Alarm Text. normal normal Set to 0. Electric Actuator: BASIC Parameters; Par. no.: Parameter name / description: Limits Min/Max: Unit type: Default setting: Commission setting: System Sw 20xxx-xx 14 Software Version 15 Actuator type ELA 01-03 nr ELA-01 16 Engine Maker Sulzer or ManB&W no ManB&W fact. 120 124-A8 ELA-01 ManB&W Actuator Gain 17 Actuator P - Gain Gain for actuator response 0-1000 120 Speed output signal 18 19 Ch 13 AO-20064-A Offset tuning Speed cmd, output offset Compensation for hardware 0 oFFSEt, 1 tuning 200 text offset offset (auto-tuning of offset (par 19)) count 0 3 33 Parameterlist Electric Actuator: EXPERT Parameters; Electric Actuator, Par. no.: Parameter name / description: Expert parameters Limits Min/Max: Unit type: Default setting: Commission setting: 5000 5000 Servo position feedback signal 20 Encoder Offset Pos. feedback offset counts. 0-10000 count Servo position feedbackfail testing Position limit Timeout 21. Actuator out of range Wrong Way Timeout 22 Rotation opposite to cmd Wrong Way cmd level Feedb. alarm 1 0 - 3.000 sec. 0.200 0.200 Feedb. alarm 2 0 - 3.000 sec. 0.500 0.500 20-20000 count / 5ms 300 300 0.001-3.000 sec. 0.300 0.300 0.001-3.000 sec. 0.500 0.500 1 - 100% % 25 25 0 - 20.0 sec. 5.0 10.0 23. Actuator rotation opposite to cmd 24 Too Slow Timeout at fast speedcmd 25 Too Slow Timeout at slow speedcmd 26 Too Slow, slow speed (% of max speedcmd) Feedb. alarm 2 Other Status Other Status Other Status 27 Too Slow Block, Timeout Blocks only if time is adjusted above 0.0 sec. Feedb. alarm 8 Feedbackfail, alarm nr. 01 02 Data out of range Wrong way 08 10 Too slow (or not moving) Loopfail Continuously tested These alarms are only tested in running mode. Continuously tested Idle Mode 28 Plus Key, actuator speed. 29 Minus Key, actuator speed. 30 Range Limitations On. 31 blank 32 Setting of actuator behavior in Idle Mode. (In Stop) 33 34-36 (Double speed if rate is on) (Double speed if rate is on) Limited range: 0 - max Pump Index Actuator force in Idle Mode (Max speed cmd) if activ in idle blank AO-20064-A 0-1000 count 100 200 0-1000 count 100 200 text Lim-On Not saveable Maker passive Lim-On or LimOFF Maker, Active, Passive, Passive-Block text 0 - 2047 count (MAN B&W = passive) 300 300 34 Parameterlist Electric Actuator, Par. no.: Parameter name / description: Expert parameters Limits Min/Max: Unit type: Default setting: Commission setting: Major Alarm 37 38 K2 Relay 39 Alarm input filter 0 - 25 sec 1.0 1.0 Holding on delay 0 - 20 sec 5.0 5.0 Holding off delay 0 - 20 sec 5.0 5.0 Digital input signals Ch. 09 Ext. Stop ( f / Safety) “Or” mask Ch. 15 Servo Ampl. Fail. (DSU) “Or” mask Ch. 16 Manual Mode. (DSU) “Or” mask True / False text True True True / False text False False True / False text True True 43 Block when Low Voltage True/False text True True 44 Actoator Rotation Direction CW / CCW text from dip sw.! CCW 40 41 42 Clock Wise or Counter Clock Wise. ch 4, Fuel output signal. Actuator position. 45 46 47 48 Counts low (dac1 = 8bit) Counts high (dac1 = 8bit) Technical low (100% = max actuator stroke) Technical high (100% = max actuator stroke) 0 - 255 count 50 (4mA) 0 - 255 count 254 (20mA) 50 254 0 - 100.0 % 25 25 0 - 100.0 % 100.0 100.0 On/Off text Off Off disable or enable text disable Disable Output signal test 49 Test switch 50 Test switch 51 Idle mode only Idle mode only Brake On (ch 12) Torque enable (ch 7) blank AO-20064-A 35 Parameterlist Electric Actuator, Par. no.: Parameter name / description: Expert parameters Limits Min/Max: Unit type: Default setting: Commission setting: Analog readable signals, 52 53 54 55 0 14 -14 3 Actuator, Command Position (counts ) same as param. 02, but in counts. Actuator, Actual Position (counts) same as param. 03, but in counts. Actuator, Cmd/Actual Difference (counts) same as param. 04, but in counts. Servo speed Cmd, from servo speed regulator ( Ch.13 output 2047 counts) Digital readable signals, 56 57 58 59 60 61 62 True Handle in stop position. Ch.09, External Stop (Safety System SHD). Ch. 15, Servo Amplifier Fail active. Ch. 16, Manual Mode active. Ch. 12, Dig. output - Brake deactivated. Run signal Ch. 07, Dig. output - Torque enable signal Block Condition False False False False False 0000 0001 Low Voltage 0002 Feedback Fail 0004 Indata error 0010 Reg. Watch Dog (Hardware) 0020 Reg. Fatal Error (Double Pickup Fail) 0100 Servo Amp. Fail (Power 440V, DSU int.24V, Thermic Switch in motor, Servo amp.) 0200 Buffer com. error (NA-1105) 63 blank 64 Signals from Dac2, Dac3 & Dac4. true/false 65 System Date, If adjusted and saved, all adjustments will be reset dd-mm-y Special parameters, text False 7017 ( at power up ). 66 67 68 99 Eprom checksum (readable) Processor Speed Process. card type Desimal point for Fuel parameters 2,3 & 4 Service code AO-20064-A false ISCF 5 or 8 MHz 8 MHz dp0 - dp2 text Fu-dP0 Set to 8 MHz Fu-dp0 47. 36 Parameterlist Gereral Information, Regulator. REGULATOR OpCode 0, Param. 14 selected nr. 0 1 2 3 4 5 6 7 8 REGULATOR OpCode 0, "Reg. General Information" param. 4 Displayed value Propeller pitch 1.0 RPM command difference (Control room - bridge) (RPM) -22.0 RPM command alternative (The one not in use) (RPM) 45.0 RPM command from control room (RPM) 23.0 RPM command from bridge (RPM) 45.0 Fuel command to actuator (% fuel) 0.0 Lowest fuel limiter (% fuel) 45.0 Margin to lowest fuel limiter (% fuel) 45.0 Identity of lowest active fuel limiter: 0.0 identity value 0.0 = No Fuel Limiter 4.0 = Zero Pitch Fuel Limiter,Cpp only 1.0 = Torque Fuel Limiter 5.0 = Start Fuel Setpoint 2.0 = Scav. air Fuel Limiter 3.0 = Manual Fuel Limiter 99.0 = Maximum Fuel Output Gereral Information, Actuator. REGULATOR OpCode 1, Param. 76 selected text 0 Cmd Rpm 1 Eng. Rpm 2 torque 3 Power 4 Load 5 PuMP I 6 ACt. MM 7 AnGLE 8 Count ACTUATOR, param. 6 "Act. General Information" Value displayed Speed setpoint ( 0-300 Rpm ) Actual engine speed ( 0-300 Rpm) Fuel pump position cmd. ( 0 - 100 %) without nonlinear compensation Engine Power ( 0 - 100 %) = (Fuel cmd * Engine speed) Fuel pump position cmd. ( 0 - 100 %) with nonlinear compensation Pump Index ( 0 - 150 Pump mm) Actuator stroke (0 - 100 mm) Angle (0 - 42 Deg.,) Only relevant for El. Actuator Actuator Command (Counts) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 System in test, Regulator. OpCode 0, Param. 19 Readable Info. "System in test" 00 = Normal 01 = Special Mode; - Test, Calibrate or Self-Test 02 = Special Mode; - Fuel Setpoint (Regulator Bypass) 04 = Special Mode; - RPM Measured, Step Signal Added. 08 = not used 10 = Simulation; - Analog Input 20 = Simulation; - Digital Input 40 = Special Mode; - Fixed Fuel (indicator diagram mode) 80 = Simulation; - Multi-freq. sinus noise (for Notch Filter) AO-20064-A change with; OpCode 0, Param. 1 Panel, Push Button Panel, Push Button Panel, Push Buttons OpCode 2, dig.Chan. OpCode 0, Param. 20 OpCode 1, Param. B8 37 Parameterlist Alarm codes, Regulator. ALARMS ERROR POSSIBLE CORRECTIVE MEASURE OpCode 0 par. 11 par. 12 normal normal No errors ALr 1 30Loop ALr 2 31Loop ALr 3 30Sign Adaptor Ch.30 Loop Fail Adaptor Ch.31 Loop Fail Adaptor Ch.30 Signal Fail ALr 4 31Sign Adaptor Ch.31 Signal Fail ALr 5 bUFF H Data Buffer NA-1105, Hardware not responding ALr 6 bUFF C Data Buffer NA-1105, Communication error. Checksum error. ALr 7 SiMuLA System in test ALr 8 FAtALr Adaptor Ch.30 & 31 Dual Rpm Detector Fail. ALr 9 17-Err ALr10 18-Err ALr11 19-Err ALr12 20-Err ALr13 21-Err Adaptor Ch.17 Rpm Cmd (Ctrl.Room) Adaptor Ch.18 Rpm Cmd (Bridge) Adaptor Ch.19 Pitch fedback. Adaptor Ch.20 Scav Air Pressure Adaptor Ch.21 normally not used ! ALr 15 LoVolt AO-20064-A Power Monitoring Card, NN-825 Rpm detector fail Check inside DGU at adaptor-card ch 30 / 31 and find which led is on. a) Upper diode indicate open circuit b) Lower diode indicate short circuit. a) Check pickup distance b) Check pickup for dirt c) Change pickup d) Check the supply voltage in the pickup, box, terminal 1-3 and 5-7. e) Change Counter IC-18a on NN-791 f) Change the NN-791 processor card Outdata error Check inside DGU and locate NA-1105. See if the card or the flat cable has loosend or is damaged. Change the Data Buffer or the processor cards. System in test Reset test function. Rpm detector fail a) Check all the above possibillities . Indata error a) Check cables for short/open circuit. b) Replace or adjust adaptor-card. c) Check transducer. d) Check for the “AC” parameter and see if Actual Counts is changed when changing the input signal. e) Check adjustments in OpCode 2. signal error limits (EL, EH) and scale (CO, CL, CH, tL, tH). Low Voltage Check inside DGU and locate NN-825. See which led diode is lighting 38 Parameterlist Alarm codes, Actuator. ALARMS ERROR POSSIBLE CORRECTIVE MEASURE OpCode 0 par. 11 par. 12 normal normal No errors ALr 1 rAnGE ALr 2 Wr Way ALr 3 StEP ALr 4 too SLo Feedback fail, Signal out of range. Feedback fail, actuator wrong way rotation. Feedback fail, Abrupt change. Feedback fail, Too Slow response. ALr 5 Loop F Feedback fail, Loop Fail. ALr 9 reg-dG Regulator Watch Dog passive. ALr 12 bUFF H ALr 13 bUFF C Data Buffer NA-1105, Hardware not responding Data Buffer NA-1105, Communication error. Checksum error. ALr 14 SErVo Servo Amplifier fail AO-20064-A Feedback fail Check actuator function in test mode. Adjust the range if nesseserry. Adjust the Wrong Way Timer if nesseserry (see actuator parameter adjustments). Replace the Parvex ABS or SBS. Check feedback cable or plug. Replace the NN1105 data buffer or absolut encoder. Check mechanical limits or restrictions. Check fuelrack for friction. Increase the adjustment of the Too Slow Timer or Cmd. Increase the actuator gain. Check feedback cable and plug. Replace the NN1105 data buffer or absolut encoder. Indata error a) Check the power plugs to the proc. card. b) Replace the processor card. c) Check the flatcables to P1 plugs. d) Replace the PPI on actuator processor card. Check inside DGU and locate NA-1105. See if the card or the flat cable is loose or damaged. Change the Data Buffer or the processor cards. Servo amplifier fail a) Servo power supply(220/440V, 3phase), b) Servo drive enable signal in DSU, c) El.motor thermic shut down, d) 24 Volt in DSU not operative. 39
© Copyright 2025 Paperzz