DAYLED LED TROFFER 2X4 quality performance, energy savings, an economical solution Project: PHILIPS DAY-BRITE DAYLED LED TROFFER 2X4 Location: Catalog No: Fixture Type: The Philips Day-Brite DayLED is an LED troffer offering general lighting distribution excellent for ambient illumination. It features a sealed, maintenance free, low profile housing, along with a frameless design that maximizes its luminous aperture and provides a clean, attractive ceiling appearance. Mfg: Qty: Notes: Ordering guide Width Family 2 2' LT example: 1LTG34L840-4-21-UNV Ceiling Type Lumen Package G Grid 40L Color Length — DayLED LED Troffer 47L 56L 71L 4000 nominal delivered lumens 4700 nominal delivered lumens 5600 nominal delivered lumens 7100 nominal delivered lumens Accessories (order separately) • FMA24 – 2'x4' "F" mounting frame for NEMA "F" mounting 482-SR 08/14 840 835 80 CRI, 4000K 80 CRI, 3500K Lens Voltage Options — 4 4' 21 12 19 184 Pattern 12, 347 .125" nominal UNV Universal DB-12, .156" voltage, nominal 120-277 volt DB-19, .156" nominal Pattern 12, .125" nominal, diffuse See sheet 420-SR for other options Canadian Market DIM 0-10V dimming driver SDIM Step dimming driver F1 3/8" flex, 3 wire 18 gauge GLR1 Fusing, fast blow CM DAYLED LED TROFFER 2X4 Application Electrical • High efficacy long life solid state lighting platform. • General lighting distribution is excellent for ambient lighting. • Lumen packages range from 4,000 to 7,100 lumens, providing flexibility to optimize light levels for a specific application. • High CRI source provides excellent color rendering. • LEDs are an excellent source for use with controls since frequent switching does not affect the life of the light source. • Suitable for use in clean room application. • Driver and LED boards are accessible from above. LED boards are individually replaceable if required. • ETL listed to UL standards, suitable for damp locations. • Five-year luminaire warranty including LED boards and driver. • High efficiency LEDs have 50,000 hour rated life (defined as 70% lumen maintenance.) • Combinations are available providing up to 93 delivered lumens per Watt. • Rated for clean room use – meets ISO14644-1 Class 5 (equivalent to Federal Standard No. 209E Class 100). • Listed for used in insulated ceilings (Type IC). Contruction/Finish • Lower housing includes smooth edges for safe, easy handling. • Housing is multi-stage phosphate treated for maximum corrosion resistance and finish coat is high reflectance baked white enamel. • Sealed housing prevents the entry of dirt and bugs into the luminaire which eliminates the need for internal cleaning and reduces maintenance. • T-bar clips are included. Dimensions 48" O.C. Grid Tees (1219mm) 482-SR 08/14 page 2 of 5 • Standard sealed configuration does not include a door frame since cleaning and relamping are not required. • Frameless design maximizes luminous aperature and provides a clean appearance. • A variety of lenses are available to tailor the luminaire to the application. • Contact factory for applications requiring a door frame. Energy data 3-9/16" (90mm) 24" O.C. Grid Tees (610mm) Enclosures Model Initial Delivered Lumens at 25˚C Ambient* Input Power Lumens Per Watt* 2LTG40L840-4-21 4,034 45W 90LPW 2LTG40L840-4-184 3,896 45W 87LPW 2LTG47L840-4-21 4,658 53W 88LPW 2LTG47L840-4-184 4,521 53W 85LPW 2LTG56L840-4-21 5,598 60W 93LPW 2LTG56L840-4-184 5,492 60W 92LPW 2LTG71L840-4-21 7,067 78W 91LPW 2LTG71L840-4-184 6,935 78W 89LPW *3500K models are approx. 7% lower. DAYLED LED TROFFER 2X4 DayLED LED Troffer 2x4, 4000 nominal delivered lumens, standard lens Catalog No. 2LTG40L840-4-21 Test No. 29847 S/MH 1.2 Source 45WLED Lumens/Lamp 4034 Input Watts 45 Comparative yearly lighting energy cost per 1000 lumens – $2.67 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Candlepower AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 LER – 90 171017101710 171617061685 169416811667 166016451631 160015931581 152215201515 142014221428 129112981310 114111531166 975980991 798793798 628612615 473447450 342305324 262211234 206158176 150123130 817174 Photometric values based on test performed in compliance with LM-79. Degrees 0-30 0-40 0-60 0-90 2LTG40L840-4-184 Test No. 29717 S/MH 1.2 Source 45WLED Lumens/Lamp 3896 Input Watts 45 Comparative yearly lighting energy cost per 1000 lumens – $2.76 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Candlepower AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Cross 164416441644 164116331631 161216061602 156515631557 150114971494 141314161415 130713091311 118211861188 104610471052 900897906 757749758 618607615 492478485 384362369 292272278 220197203 153136139 807175 Photometric values based on test performed in compliance with LM-79. 2LTG47L840-4-21 Test No. 29854 S/MH 1.2 Source 53WLED Lumens/Lamp 4658 Input Watts 53 Comparative yearly lighting energy cost per 1000 lumens – $2.73 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Photometric values based on test performed in compliance with LM-79. 482-SR 08/14 page 3 of 5 Candlepower AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Cross 197319731973 197819701944 195619391921 191518981880 185118391823 175717511745 164116411647 148814971511 131813311346 112411311138 921913917 725707710 546520524 399354372 303242269 238181203 173142152 958287 % Luminaire 32.8 52.9 85.3 100.0 AngleEnd 45°Cross 45 211221232147 55 167716341642 65 123911051174 75 12199351042 85 142312481300 EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1110 105101 107103 98 98 95 2101 9386 979184 8882 393 8275 908173 7871 484 7366 827265 6964 579 6757 776657 6456 672 5952 705952 5751 768 5546 665446 5346 863 5041 615041 4740 958 4639 574638 4538 1056 4234 544134 4034 LER – 87 Light Distribution Average Luminance Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 194919431962 55 165016211642 65 139213121337 75 130211661201 85 140612481318 Lumens % Luminaire 1244 32.0 198450.9 322482.8 3894100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1109 105101 107102 98 97 94 2100 9285 969083 8681 392 8173 898072 7770 483 7265 817164 6861 578 6656 766556 6155 671 5851 695750 5648 767 5446 655345 5245 863 5040 604840 4740 958 4638 564536 4436 1055 4134 544134 4034 DayLED LED Troffer 2x4, 4700 nominal delivered lumens, standard lens Catalog No. Lumens 1324 2134 3441 4034 Coefficients of Utilization DayLED LED Troffer 2x4, 4000 nominal delivered lumens, diffuse lens Catalog No. Average Luminance Light Distribution Cross LER – 88 Light Distribution Average Luminance Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 243524502465 55 193618881896 65 144612831348 75 140810711201 85 166914411529 Lumens % Luminaire 1528 32.8 246352.9 397385.3 4659100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1110 105101 107103 98 98 95 2101 9386 979184 8882 393 8275 908173 7871 484 7366 827265 6964 579 6757 776657 6456 672 5952 705852 5751 768 5546 665446 5346 863 5041 615041 4740 958 4639 574638 4538 1056 4234 544134 4034 DAYLED LED TROFFER 2X4 DayLED LED Troffer 2x4, 4700 nominal delivered lumens, diffuse lens Catalog No. 2LTG47L840-4-184 Test No. 29708 S/MH 1.2 Source 53WLED Lumens/Lamp 4521 Input Watts 53 Comparative yearly lighting energy cost per 1000 lumens – $2.82 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Candlepower AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Cross 190219021902 189218961883 185918671851 180518131796 172717411727 163216421635 150615211511 136413761369 120612161213 104210481048 876873874 718708710 569558560 447424428 341318321 257231236 176158161 958488 Photometric values based on test performed in compliance with LM-79. LER – 85 Light Distribution Average Luminance Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 225722702270 55 191718911896 65 162015371551 75 152113671397 85 166914761546 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1109 105101 107102 98 97 94 2100 9285 969083 8681 392 8173 898072 7770 483 7265 817164 6861 578 6656 766456 6155 671 5851 695750 5648 767 5446 655345 5245 863 5040 604840 4740 958 4638 564536 4436 1055 4134 544134 4034 DayLED LED Troffer 2x4, 5600 nominal delivered lumens, standard lens Catalog No. 2LTG56L840-4-21 Test No. 29832 S/MH 1.2 Source 60WLED Lumens/Lamp 5598 Input Watts 60 Comparative yearly lighting energy cost per 1000 lumens – $2.58 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. LER – 93 Candlepower Light Distribution Average Luminance AngleEnd 45 Cross 0 236523652365 5 236523572341 10 233823292313 15 228522752263 20 220922012193 25 209821032099 30 195919681976 35 178117971816 40 157215971615 45 134313631378 50 110011021111 55 870851861 60 653620637 65 482427461 70 370290323 75 288221245 80 207172185 85 109100104 Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 290929522985 55 232322722299 65 174715481671 75 170413081450 85 191617571828 Photometric values based on test performed in compliance with LM-79. 2LTG56L840-4-184 Test No. 29730 S/MH 1.2 Source 60WLED Lumens/Lamp 5492 Input Watts 60 Comparative yearly lighting energy cost per 1000 lumens – $2.61 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Photometric values based on test performed in compliance with LM-79. 482-SR 08/14 page 4 of 5 Lumens % Luminaire 1831 32.7 295252.7 476985.2 5598100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1110 105101 107103 98 98 95 2101 9386 979184 8882 392 8275 908173 7871 484 7366 827265 6964 579 6757 776657 6356 672 5952 705851 5751 768 5546 665446 5346 863 5041 615041 4740 958 4639 574638 4538 1056 4234 544134 4034 DayLED LED Troffer 2x4, 5600 nominal delivered lumens, diffuse lens Catalog No. Lumens % Luminaire 1441 31.9 229850.8 373882.7 4519 100.0 LER – 92 Candlepower Light Distribution Average Luminance AngleEnd 45 Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 274427422753 55 233422802304 65 195318451874 75 182916511687 85 195117751863 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Cross 232123212321 231623122297 227522712258 221122052195 211721152109 199719991996 184318501850 167116681675 147514761486 126712661271 106710541062 874854863 693674675 539509517 413381390 309279285 213189195 111101106 Lumens % Luminaire 1758 32.0 280151.0 454882.8 5490100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1109 105101 107102 98 97 94 2100 9285 969083 8681 392 8173 898072 7770 483 7265 817164 6861 578 6656 766556 6155 671 5851 695850 5650 767 5446 665345 5245 863 5040 604840 4740 958 4638 564536 4436 1055 4134 544134 4034 DAYLED LED TROFFER 2X4 DayLED LED Troffer 2x4, 7100 nominal delivered lumens, standard lens Catalog No. 2LTG71L840-4-21 Test No. 29838 S/MH 1.2 Source 76WLED Lumens/Lamp 7067 Input Watts 78 Comparative yearly lighting energy cost per 1000 lumens – $2.64 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Candlepower AngleEnd 45 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Cross 297729772977 298129702948 294229312911 288228712849 278427742757 265126512643 247524812489 224622722287 199320222040 169617141742 138513901403 109210761090 827791807 602541577 460372415 363278310 261216232 138125135 Photometric values based on test performed in compliance with LM-79. LER – 91 Light Distribution Average Luminance Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 367437133773 55 291628732911 65 218219612091 75 214816451834 85 242521972372 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1110 105101 107103 98 98 95 2101 9386 979184 8882 392 8275 908173 7871 484 7366 827265 6964 579 6757 776557 6356 672 5952 705851 5751 768 5546 665446 5346 863 5041 615041 4740 958 4638 574638 4538 1056 4234 544134 4034 DayLED LED Troffer 2x4, 7100 nominal delivered lumens, diffuse lens Catalog No. 2LTG71L840-4-184 Test No. 29724 S/MH 1.2 Source 76WLED Lumens/Lamp 6935 Input Watts 78 Comparative yearly lighting energy cost per 1000 lumens – $2.70 based on 3000 hrs. and $.08 pwr KWH. The photometric results were obtained in the Philips Day-Brite laboratory which is NVLAP accredited by the National Institute of Standards and Technology. Lumens % Luminaire 2309 32.7 372352.7 601885.1 7069100.0 LER – 89 Candlepower Light Distribution Average Luminance AngleEnd 45 Cross 0 292529252925 5 291929132897 10 286928632850 15 279127812770 20 267126712660 25 251725172515 30 232623342332 35 211021122118 40 185918671879 45 160316041614 50 134913321338 55 109810811092 60 876844852 65 681648653 70 522481490 75 393352356 80 270238245 85 141129136 Degrees 0-30 0-40 0-60 0-90 AngleEnd 45°Cross 45 347234743496 55 293228872916 65 246823482367 75 232620832107 85 247822672390 Photometric values based on test performed in compliance with LM-79. © 2014 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires 482-SR 08/14 page 5 of 5 Lumens % Luminaire 2217 32.0 353451.0 574282.8 6932100.0 Coefficients of Utilization EFFECTIVE FLOOR CAVITY REFLECTANCE 20 PER (pfc=0.20) pcc80 70 50 pw 705030 705030 5030 RCR 0 118118118 115115115 111111 1109 105101 107102 98 97 94 2100 9285 969083 8681 392 8173 898072 7770 483 7265 817164 6861 578 6656 766556 6155 671 5851 695750 5648 767 5446 655345 5245 863 5040 604840 4740 958 4638 564536 4436 1055 4134 544134 4034 Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ 08873 Tel. 855-486-2216 Imported by: Philips Lighting, A division of Philips Electronics Ltd. 281 Hillmount Rd, Markham, ON Canada L6C 2S3 Tel. 800-668-9008
© Copyright 2026 Paperzz