21-12-2016 49 Halton Way Mr Mc Bean

For full details and materials please refer to the provided specification.
Bi-fold doors installed, to be to clients choice of material.
Glazing to comply with the provided specification.
3000
Air Vent For Stove
(104cm²)
Existing Garage
SD
2740
2500
2740
2220
2800
5133
30
0
0
15
0
30
Non structural timber stud wall to
house insulation and services.
Built off 2000 gauge DPM. DPM to
be taken 1m up the existing walls
and tied into DPC of new cavity
walls.
please refer to the provided
specification.
Neighbors Garage
2790
Garage to be extended to
the rear, up to the
boundary on two sides.
Raft foundation proposed
due to proximity of
leylandii tree, 4m high
within close proximity.
Woodburing stove installed to
manufacturers instructions, to be
maximum 3KW. Flue taken above
the line of the existing ridge by
300mm.
Combined Optical Smoke and CO Alarm
Level 0
The boundary Fence
Level 0 Existing & Demolish
1 : 50
2 layers of 12.5mm Fireproof Plasterboard by brittish gypsum or similar
1 : 50
Hearth size
Hand cut roof to the extension, to allow for vaulted ceiling
and velux windows to be installed. Rafter to be doubled up
either side of the velux windows. Within the existing
garage roof, insulation to be placed at high level to
maintain the existing roof trusses. 2x200x50mm timber
purlin installed as shown to allow removal of part of the
trusses where the new roof abuts the existing.
The boundary fence
11689
Level 1
2310
2310
N
or
t
Level 1
13360
Decking area size and
material to be decided
by client.
Level 0
Level 0
0
0
East Existing
East Proposed
1 : 100
1 : 100
2810
11395
2834
Interlocking Marley tiles to
be used, to be Marley
Concrete plain roof tile
Site & Roof plan Existing
1 : 200
Level 1
Level 1
The boundary wall is a 1.8m
high timber panel fence
2310
2310
Level 1
2310
The proposals require only
the new rainwater to tie into
the existing
Roof timbers to be 150x50
C16 grade timbers (doubled
up either side of velux) with
100mm Kingspan K7
pitched roof board insulation
placed between the rafters,
with 50mm ventilation and
32.5 K118 insulated
plasterboard to the
underside, to achieve 0.18
U-value .
Level 0
Level 0
11516
0
0
100mm Kingspan
thermafloor tf70 insulation
friction fitted between
100x50mm timbers to
achieve 0.22 U-value
West Proposed
West Existing
1 : 100
1 : 100
22mm chipboard flooring
2310
2310
10338
Level 1
2100
Level 1
2000 gauge visqueen DPM,
100mm
Level 0
Level 0
0
0
North Existing
1 : 100
Level 0
0
8590
North Proposed
1 : 100
The proposed
development is
wholely within
the applicants
land.
100mm in-situ concrete floor
slab (make sure proposed
concrete level ties in with
the existing garage)
Raft foundation to be
175mm thick RC 35 concrete
sitting on 150mm of well
compacted hard core.
A 393 top and bottom with
double layer of A393 mesh to
the top around the perimeter
under the walls. This is to
extend inwards 1.4m from
the edge.
Mr Mc Bean
49 Halton Way
Development side
Date
Level 1
Level 1
2310
2310
Drawn by
Neighbors
Level 0
Level 0
0
0
South Existing
1 : 100
21-12-2016
Scale @ A1
South Proposed
Site & Roof plan Proposed
1 : 100
1 : 100
Section 1
1 : 25
SZK
As indicated
This drawing remains the COPYRIGHT of
Acre Design and may not be reproduced in
whole or any part without prior written
permission.