For full details and materials please refer to the provided specification. Bi-fold doors installed, to be to clients choice of material. Glazing to comply with the provided specification. 3000 Air Vent For Stove (104cm²) Existing Garage SD 2740 2500 2740 2220 2800 5133 30 0 0 15 0 30 Non structural timber stud wall to house insulation and services. Built off 2000 gauge DPM. DPM to be taken 1m up the existing walls and tied into DPC of new cavity walls. please refer to the provided specification. Neighbors Garage 2790 Garage to be extended to the rear, up to the boundary on two sides. Raft foundation proposed due to proximity of leylandii tree, 4m high within close proximity. Woodburing stove installed to manufacturers instructions, to be maximum 3KW. Flue taken above the line of the existing ridge by 300mm. Combined Optical Smoke and CO Alarm Level 0 The boundary Fence Level 0 Existing & Demolish 1 : 50 2 layers of 12.5mm Fireproof Plasterboard by brittish gypsum or similar 1 : 50 Hearth size Hand cut roof to the extension, to allow for vaulted ceiling and velux windows to be installed. Rafter to be doubled up either side of the velux windows. Within the existing garage roof, insulation to be placed at high level to maintain the existing roof trusses. 2x200x50mm timber purlin installed as shown to allow removal of part of the trusses where the new roof abuts the existing. The boundary fence 11689 Level 1 2310 2310 N or t Level 1 13360 Decking area size and material to be decided by client. Level 0 Level 0 0 0 East Existing East Proposed 1 : 100 1 : 100 2810 11395 2834 Interlocking Marley tiles to be used, to be Marley Concrete plain roof tile Site & Roof plan Existing 1 : 200 Level 1 Level 1 The boundary wall is a 1.8m high timber panel fence 2310 2310 Level 1 2310 The proposals require only the new rainwater to tie into the existing Roof timbers to be 150x50 C16 grade timbers (doubled up either side of velux) with 100mm Kingspan K7 pitched roof board insulation placed between the rafters, with 50mm ventilation and 32.5 K118 insulated plasterboard to the underside, to achieve 0.18 U-value . Level 0 Level 0 11516 0 0 100mm Kingspan thermafloor tf70 insulation friction fitted between 100x50mm timbers to achieve 0.22 U-value West Proposed West Existing 1 : 100 1 : 100 22mm chipboard flooring 2310 2310 10338 Level 1 2100 Level 1 2000 gauge visqueen DPM, 100mm Level 0 Level 0 0 0 North Existing 1 : 100 Level 0 0 8590 North Proposed 1 : 100 The proposed development is wholely within the applicants land. 100mm in-situ concrete floor slab (make sure proposed concrete level ties in with the existing garage) Raft foundation to be 175mm thick RC 35 concrete sitting on 150mm of well compacted hard core. A 393 top and bottom with double layer of A393 mesh to the top around the perimeter under the walls. This is to extend inwards 1.4m from the edge. Mr Mc Bean 49 Halton Way Development side Date Level 1 Level 1 2310 2310 Drawn by Neighbors Level 0 Level 0 0 0 South Existing 1 : 100 21-12-2016 Scale @ A1 South Proposed Site & Roof plan Proposed 1 : 100 1 : 100 Section 1 1 : 25 SZK As indicated This drawing remains the COPYRIGHT of Acre Design and may not be reproduced in whole or any part without prior written permission.
© Copyright 2026 Paperzz