Trench Heating Units A good climate and a clear view Katherm HK, Katherm QK, Katherm QK nano, Katherm QE Genau mein Klima. Exactly my kind of climate. Intro Floor trenches are the first choice for high-end rooms with floor-to-ceiling glazing. Conventional radiators often obstruct the view and draw unwanted attention to them. They clash with the architectural interior vision. Kampmann floor trenches are installed in the floor in front of the glazing, blending into the overall interior design and providing effective temperature control. Full space heating and cooling, residual heat provision, cold air screening and façade ventilation: Kampmann trench heaters guarantee a comfortable interior climate even under difficult conditions. Inhalt 4 17 22 34 Areas of application References Products In detail Company Hotels Offices and commercial buildings Showrooms and sales floors Churches and historical buildings Image title: Faculty of Cultural and Social Science at the University of Salzburg, Austria Nursery schools and schools Residential buildings 3 Blends harmoniously into every room interior. Faculty of Cultural and Social Science, University of Salzburg, Austria 600 Katherm HK trenches with roll-up grilles were fitted to the external façade. EC tangential fans provide filtered, heated or cooled air on demand. As such, Katherm HK provide a good climate from the floor. Swedbank AB, Stockholm, Sweden Transparency is the most obvious feature of the full-height windows. The view remains undisturbed thanks to 731 Katherms mounted in the floor as a continous line. The trench heating units with natural convection provide effective cold air screening. The installed Katherms stand out with their low thermal mass and are easy to control. Quick delivery and fast installation with Eurokonus valve connections ensured a seamless and smooth project flow in Sundbyberg. Heating and cooling energy-efficiently. Adapts to any view. Kristall-Holzhafen, Hamburg, Germany Katherm HK trench heating units provide heating or cooling in all apartments, supplying on-demand filtered, heated or cooled recirculating air. The tailor-made trench heating units respond flexibly to the needs of the occupants: integrated sockets, data jacks and even a sound system. A decentralised indoor climate from the floor provides a clear view of the breathtaking panorama of the Holzhafen timber port, the oldest preserved docks in Hamburg. ADAC Headquarters, Munich, Germany In the ADAC headquarters in Munich, a bespoke version of the Katherm HK with energy-efficient EC tangential fans ensures quiet operation and energy savings. This trench version channels filtered, heated or cooled ambient air from the floor in line with current demand. In perfect symmetry. Katherm HK and Katherm HK empty trenches were individually adapted to the polygonal external façade. Manufactured as customised units, the encased units harmoniously meet the architectural and design specification. They also help to heat the room up faster. Blending in unobtrusively. MobileLifeCampus, Wolfsburg, Germany The Volkswagen AG building features over 800 networked trench units. Heating and cooling is largely provided by 600 Katherm HK units. There are also an additional 200 Katherm units of other types. Some 1.2 kilometres of linear Optiline grilles produce a uniform appearance. Kampmann Tandem door air curtains also provide an optimum climate in the door areas. Saving energy on every metre. SIDI Sport, Maser (Treviso), Italy 110 metres of Katherm HK trench units create perceptible interior comfort in the new building of the renowned sporting goods manufacturer. The trench units are synonymous with on-demand, individually adjustable heating or cooling from the floor. The Katherm HK configuration with EC tangential fans guarantees energy-savings of approximately 60 % over conventional fans. Empty trenches were connected to the active units to create a coherent interior architectural design. Natural aluminium anodised roll-up grilles and matching central covers enhance the sophisticated appearance. Product | Made-to-measure solutions Trench heaters are also available as customised units Blowing air gently into the entire space. Kampmann is the undisputed market leader Air conditioning systems are constantly evolving in trench heating. We have gained this position at Kampmann, which has enabled us to repeatedly not least due to our numerous made-to-measure reduce the dimensions of our Katherm HK. The solutions, adapted to specific applications. Katherm HK is now 30 mm shallower and 50 mm Electric solutions are popular on the international slimmer than its predecessor without compromising market. Kampmann meets this demand with its on output (measured in accordance with EN 16430). Katherm QE, the trench heater with EC tangential Thanks to redesigned components, it now delivers fan-assisted convection and electric heating coil. optimised air flow for higher outputs. The Katherm HK No water connection is needed. High heat outputs is the trench unit that also provides cooling. with low noise levels are guaranteed. The Katherm QK nano is even more space-saving than The Katherm QK is whisper-quiet. It is also available in the Katherm HK, only 70 mm in height and 165 mm 120 versions. It comes in non-standard lengths, with in width. The Katherm QK nano is used wherever curved trench, mitres, cut-outs for columns or angles. depth is restricted for underfloor solutions and the Its ultra-long EC fan covers the entire heating range, room volume needs to be used to the full. from full space heating to cold air screening. Schloss Elmau Retreat, Germany Katherm QK trench heaters quietly and quickly warm up the space. The EC motor-operated fan blows heated air up the cool window fronts before it is drawn into the room and heats it evenly and without draughts. Katherm HK also provide additional heating as well as cooling. The KaControl system links the trench units to the building management system. The air outlets on the Katherm units stylishly complete their appearance. Lacquered oak roll-up grilles were selected for the Retreat, which wonderfully enhance the rest of the interior. 17 18 Product | Elbphilharmonie Product | Elbphilharmonie Katherm made-to-measure trenches for the Elbphilharmonie in Hamburg Kampmann is known for finding solutions to The architectural fittings in the building provided even the most challenging applications. The a challenge when implementing the project. Usually Hamburg Elbphilharmonie, one of Europe’s most trench heating and cooling units are positioned as exciting new-build projects, is a case in point. close as possible to the glazed façade. Kampmann special Katherm HK trench heating and cooling units were developed especially for this project. This was impossible at the Elbphilharmonie, the The units are used in rooms which musicians use to Katherm HK had to be installed a metre from warm up their instruments. Very specific temperatures the windows. are subsequently required in these rooms. In addition, a large volume of air has to be fed into the rooms As cooling requirements were constantly changing, to ensure that they are correctly air conditioned. And between 2009 and 2013 numerous measurements of course the concentration of the musicians must of the non-standard trenches were taken in the not be disturbed by external noise! Kampmann Research & Development Centre (FEC). The final measurements were taken in June 2013 According to these key specifications for the project, for the heating and cooling outputs with particular the units had to be practically silent. The ultra- focus on the latter. silent Katherm HK tipped the balance in favour of Kampmann when the order was awarded. The Katherm HK units were finally delivered in two different versions in a special non-standard design, Ultimately the plan was to cover the window façades in a width of 300 mm (the standard trench is 40 mm of the rooms with heavy fabric curtains. At short wider) and a single row of tangential fans, and also notice, the standard Kampmann HK with one row of in a width of 470 mm with two rows of tangential tangential fans was transformed into a non-standard fans, all units in 19 different lengths. trench with two rows of fans, to ensure that the air could be distributed noiselessly in front of and behind the curtains. 19 20 Product | Grilles Product | Grilles Individual Versatile, aesthetic, resilient Grille colours A harmony of material and design Cut-outs with a cover plate Aluminium Natural anodised E6 / EV1 Aluminium Brass anodised E6 / EV3 Aluminium Black anodised E6 Aluminium Bronze finish E6 / C31 Cut-outs in the grille itself Aluminium Painted DB703 Aluminium Painted white Brass Natural CuZn 44 Stainless steel Natural Stainless steel Polished Oak Varnished Merbau Varnished Integrated lighting Integrated sockets Mitre with profile Mitred The diversity of Kampmann design grilles sets them apart. Many models can be used on both Alignment of the bar position Curving of roll-up grille Curving of linear grille curved designs significantly extends the “life” of the grilles. The grilles integration of structural elements, like columns, pillars etc. design options enable even difficult situations to be corner designs with different angles covered with ease. Our experts can take site integration of lighting or sockets dimensions on your behalf. The following options polygonal connections to the building facade are available: Middle cover in the building grid anodised aluminium, stainless steel, wood sides, by simply turning the grilles, a feature, which can also be shortened and extended. The various Mitre with cover various cover plate materials possible: brass, 21 22 In detail | Selection aids In detail | Selection aids Which Katherm do I need? HK, QK, QK nano, QE Demand ”I would like to be able to heat and cool.” Product Description Katherm The totally redesigned Katherm HK permits demand-led heating from the floor. It also features a cooling function. With its new incremental lengths, the Katherm HK is the right solution for the most diverse building requirements. The redesigned EC tangential fan runs silently and is extremely energy-efficient. HK Benefits cost-effective efficient heating AND cooling at low noise levels in line with the Hygiene Directive VDI 6022 2-pipe or 4-pipe system for individual comfort in every room Performance data / Features Trench height [mm] Trench length [mm] Trench width [mm] Heat output Cooling output Convection Heating Cooling Ventilation Control 530 – 14278 W1) 86 – 2665 W2) 116 – 3256 W3) EC tangential fan LPHW CPW optional (indirect) KaControl control system or electromechanical control as standard optional integration into KaControl networks or building automation systems, such as KNX, Modbus or LON 130 915 1200 1700 2000 2500 3000 290 160 950 1200 1700 2000 2500 3000 320 262 – 5982 W1) -- EC tangential fan LPHW ----KaControl control system or electromechanical control as standard optional integration into KaControl networks or building automation systems, such as KNX, Modbus or LON 112 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 182 207 232 Heat output Cooling output 248 – 3524 W1) --- 70 165 Convection Heating Cooling Ventilation Control EC tangential fan LPHW ----configurations electromechanical control 24 V, electromechanical control 230 V or KaControl optional integration into KaControl networks or building automation systems, such as KNX, Modbus or LON 900 1400 1800 2100 2600 112 825 1250 1700 207 ”I would like to heat using low water temperatures.” ”I have very little space.” Katherm QK Katherm QK nano ”I would like to heat electrically.” Katherm QE The Katherm QK is whisper-quiet. It is also available in 120 versions. It comes in non-standard lengths, with curved trench, mitres, cut-outs for columns or angles. Its ultra-long EC fan covers the entire heating range, from full space heating to cold air screening. made-to-measure trench lengths high outputs at small trench depths, even when used with low temperatures whisper-quiet EC technology Heat output Cooling output Convection Heating Cooling Ventilation Control The Katherm QK nano provides high heat outputs from minimal dimensions. With a trench height of only 70 mm and a trench width of only 165 mm, it can be used wherever conventional trench solutions are impossible due to a lack of space. Due to the limited space in the unit, the interplay of the EC tangential fan and high-output copper-aluminium convector has been optimised in the Katherm QK nano. extremely low overall height maximal use of the floor space usual quietness and high-performance The Katherm QE is the ideal solution when a LPHW convector cannot be used. It stands out on account of its energy-saving and ultra-quiet EC tangential fans. The high-output electric heating element delivers high heat outputs. coupled with low sound levels. heating without water fast warm-up at low sound emissions ideal alternative to convectors with LPHW Heat output Cooling output 160 – 2400 W4) --- Convection Heating Cooling Ventilation Control EC tangential fan electric heating element ----simple, convenient electric control by via room thermostat or BMS ready-wired connection and control box with integral continuously variable power control at LPHW 75 / 65 °C, EAT = 20 °C at CHW 16 / 18 °C, EAT = 27 °C, 48 % rel. humidity 3) sensible cooling output at CHW 6 / 12 °C, EAT = 24 °C, 50 % rel. humidity 4) electric heating output at control voltage BMS 2-10 V 1) 2) 23 24 In detail | Katherm HK In detail | Katherm HK Product benefits slimmmer, shallower and more powerful than ever before EC fan, quiet and energy-efficient heat and cooling output measured according to EN 16430 Technical details Unit width Unit height Unit length Sound power level 4) B C A 2-pipe 4-pipe 2-pipe [mm] [mm] [W] [W] [W] [W] [dB(A)] [dB(A)] 915 690 – 2075 530 – 1206 107 – 451 108 – 450 <20 – 39 <28 – 47 1200 1176 – 3602 936 – 2180 191 – 814 192 – 807 <20 – 41 <28 – 49 1700 2135 – 6040 1720 – 3787 354 – 1387 355 – 1357 <20 – 41 <28 – 49 2000 2404 – 7512 1985 – 4755 398 – 1768 398 – 1744 <20 – 44 <28 – 52 2500 3363 – 10026 2773 – 6361 560 – 2339 562 – 2285 <20 – 44 <28 – 52 3000 4324 – 12479 3561 – 7967 724 – 2880 724 – 2839 <20 – 44 <28 – 52 950 780 – 2338 602 – 1357 116 – 543 116 – 525 <20 – 36 <28 – 44 1200 1312 – 3967 1030 – 2340 197 – 917 195 – 888 <20 – 38 <28 – 46 1700 2125 – 6487 1695 – 3888 313 – 1460 311 – 1414 <20 – 40 <28 – 48 2000 2765 – 8457 2214 – 5084 410 – 1912 407 – 1852 <20 – 41 <28 – 49 2500 3579 – 10986 2881 – 6642 524 – 2442 520 – 2365 <20 – 42 <28 – 50 3000 4646 – 14278 3749 – 8645 698 – 3256 693 – 3153 <20 – 43 <28 – 51 130 Katherm 290 160 4-pipe Dimensions Room side 115 Cross section Window side Trench length 305 50 165 – 210 Front view (example: 2 supply air modules) 80 165 340 ø 80 10 65 C Window side B 31 4 130 A Finned convector length 655 240 Unit length Max. number of supply air modules 340 [mm] 420 Trench heating and cooling. EC tangential fan convection. Quiet and energy-efficient. Sound pressure level 3) [mm] 320 HK Sensible cooling output 2) Heat output 1) Room side 915 / 950 1 1200 2 1700 3 2000 4 2500 5 3000 6 Plan view (without cover plate), example HK 320 with supply air modules Installation example Katherm HK 290 Installed in a raised floor, H = 160 mm, W = 290 mm, 4-pipe, cooling installation Installed in a raised floor, H = 180 mm, W = 310 mm, 4-pipe, with supply air connections, cooling installation Exterior window Exterior window Air outlet Air intake 5 3 Installation example Katherm HK 290 with supply air function 4 2 1 Concrete slab 2 Raised floor 3 Floor duct Air outlet Air intake 5 3 4 4 High performance 1 convector 5 Filter (optional) 2) 1 Concrete slab 2 Raised floor 3 Floor duct 4 High performance convector 1 at LPHW 75 / 65 °C, room air temperature 20 °C at CHW 6 / 12 °C, room air temperature 24 °C, 50 % relative humidity 3) The sound pressure levels were calculated with an assumed room insulation of 8 dB(A). This corresponds to a distance of 2 m, a room volume of 100 m3 and a reverberation time of 0.5 s. 4) Sound pressure level < 20 dB (A) and sound power level < 28 dB (A) outside the usual measuring and audible range. 1) 2 5 Filter (optional) 25 26 In detail | Katherm QK In detail | Katherm QK 27 Product benefits project solutions are available for all geometries e.g. mitred corners, curved designs, column recesses or chamfered trenches optimised for use with low temperatures heat outputs in accordance with EN 16430 Technical details Model Katherm At LPHW 35 / 30 °C Sound power level At LPHW 75 / 65 °C At LPHW 55 / 45 °C At LPHW 45 / 35 °C [W] [W] [W] [W] [dB(A)] [dB(A)] Katherm QK 182 455 – 2851 267 – 1676 175 – 1099 108 – 674 28 – 36 36 – 44 Katherm QK 207s 2) 519 – 3250 304 – 1911 200 – 1253 123 – 768 --- --- Katherm QK 207 788 – 4938 473 – 2963 315 – 1975 197 – 1235 28 – 36 36 – 44 Katherm QK 232s 2) 843 – 5284 506 – 3170 337 – 2113 211 – 1321 --- --- Katherm QK 232 954 – 5982 553 – 3463 358 – 2244 217 – 1357 28 – 36 36 – 44 Trench length L Front view Room side max. 146 112 Window side B Cross section Trench length L Window side A Trench height Trench width [mm] [mm] [mm] 112 (+4) 1000 – 3200 Katherm B Finned convector length Trench heating unit with EC tangential fan convection. All-purpose, individual, made-to-measure. Sound pressure level Dimensions 4 QK Heat output 1) QK 182 182 QK 207s 207 QK 207 207 QK 232s 232 QK 232 232 Room side Plan view, e.g. QK 207 Installation example QK 182 Installation example QK 232 Installed in screed, H = 112 mm, W = 182 mm Installed in a raised floor, H = 112 mm, W = 182 mm Exterior window Air outlet Air intake 4 5 1 2) Air outlet Air intake 1 Concrete slab 2 Heat and sound 3 3 insulation 3 Screed 4 Floor duct 2 1) Exterior window 5 High performance convector with unit lengths of 1000 mm to 3200 mm, room air temperature 20 °C provisional performance data 2 4 1 1 Concrete slab 2 Raised floor 3 Floor duct 4 High performance convector 28 In detail | Katherm QK nano In detail | Katherm QK nano Product benefits savings on floor space at usual high heat outputs new filigree FineLine grille heat outputs in accordance with EN 16430 Technical details Trench height Katherm QK Heat output 1) Sound pressure level 2) Sound power level Electromechanical model 24 V 230 V electromechanical model or KaControl [mm] [mm] [W] [W] [W] [W] [W] [dB(A)] [dB(A)] 900 1100 248 – 772 120 – 461 321 – 928 295 – 874 45 – 229 <20 – 34 <28 – 42 1400 1600 496 – 1545 241 – 922 642 – 1857 590 – 1748 90 – 458 <20 – 37 <28 – 45 1800 2000 744 – 2317 361 – 1384 963 – 2785 885 – 2621 135 – 687 <20 – 39 <28 – 47 At LPHW 75 / 65 °C At LPHW 55 / 45 °C At LPHW 90 / 70 °C At LPHW 82 / 71 °C At LPHW 40 / 30 °C 2100 2300 935 – 2912 454 – 1739 1211 – 3500 1112 – 3294 170 – 864 <20 – 40 <28 – 48 2600 2700 1132 – 3524 549 – 2105 1465 – 4236 1346 – 3987 206 – 1046 <20 – 41 <28 – 49 Dimensions 24 V electromechanical model 165 nano 4 Window side 70 Trench length A 197 Front view Cross section (enlarged), shown with transverse grille Window side Trench height A Finned convector length B [mm] [mm] 900 435 197 Trench heating unit with EC tangential fan convection. Top performance from smallest dimensions. Finned register length B 165 410 Room side Plan view (without cover plate) 1400 870 1800 1305 2100 1640 2600 1985 Installation example Installation example Installed in screed, H = 70 mm, W = 165 mm Installed in a raised floor, H = 70 mm, W = 165 mm Exterior window Air outlet Exterior window Air intake Air outlet Air intake 1 Concrete slab 2 Heat and sound 5 4 2 1 1) 2) 3 insulation 3 Screed 4 EC tangential fan 5 High performance convector 3 2 4 1 at room air temperature 20 °C The sound pressure levels were calculated with an assumed room insulation of 8 dB(A). This corresponds to a distance of 2 m, a room volume of 100 m³ and a reverberation time of 0.5 s (in accordance with VDI 2081). 1 Concrete slab 2 Raised floor 3 EC tangential fan 4 High performance convector 29 30 In detail | Katherm QE In detail | Katherm QE Product benefits 2-stage safety switch comprising safety thermostat and temperature control with air guide panels for optimum air guidance through the heating coil and out of the trench shallow trench widths and heights to blend discreetly into the interior Technical details Trench width Trench height Height / Depth of heating element Trench height Finned coil length Heat output max. Sound pressure level, max1) Sound power level, max. [mm] [mm] [mm] [mm] [mm] [W] [dB(A)] [dB(A)] 825 400 800 28 36 1250 835 1600 31 39 1700 1270 2400 33 41 207 112 25 x 50 Katherm Front view 116 – 155 Window side 207 112 Side view Trench length 825 / 1250 / 1700 Window side 207 112 Finned register length 400 / 835 / 1270 207 25 351,5 4 50 227 Room side Plan view (without cover plate) Tangential fan convection with electric heating element. Cross section (enlarged) Installation example Installed in a raised floor, H = 112 mm, W = 207 mm Exterior window Air outlet Air inlet 5 4 2 1 1) 3 1 Concrete slab 2 Screed 3 Floor duct 4 Electric heating element 5 EC tangential fan 6 Heat and sound insulation The sound pressure levels were calculated with an assumed room insulation of 8 dB(A). This corresponds to a distance of 2 m, a room volume of 100 m³ and a reverberation time of 0.5 s (in accordance with VDI 2081). 116 – 155 QE Dimensions 31 32 In detail | EN 16430 In detail | EN 16430 28 °C EN 16430 New EN standard for trench heating / cooling Thermal outputs and cooling capacities finally Comparison of air flow patterns comparable! Until now there has been no The diagram shows the major differences of the air uniform standard for determining the performance flow of short-cut optimised and non short-cut of heating / cooling trenches. The EN 16430 optimised heating / cooling trenches in cooling mode. valid as from December 2014 provides common With the short-circuit optimised model the air at the standards which apply with immediate effect. façade rises significantly higher, blends and penetrates The EN 16430 defines details for measuring deeper into the room at a higher temperature. performance data for heating / cooling trenches under The result is a more even temperature distribution real-life conditions and puts an end to uncertainties and higher comfort in the occupied zone. 28 °C in the design and in comparing performance data of different manufacturers. Heating / cooling trenches with a high short-cut Thermal outputs and cooling capacities the room. Performance data based on the entering air The standard defines details for measuring temperature are especially misleading as this can be performance data for heating / cooling trenches based significantly lower than the reference air temperature on EN 442. (room air temperature). Three parts of EN 16430 specify the measurements. The development and design of the Katherm HK have Part 1 Technical specifications and requirements been optimised to minimise the short-cut as far as Part 2 Test method and rating for thermal output technically possible. All performance data refer to the Part 3 Test method and rating for cooling capacity 750 mm percentage only provide part of the performance to reference air temperature measured at a distance of 2 m from the façade, the area in the room occupied by The EN 16430 part 3 considers the special people. requirements for cooling mode. The reference air temperature is measured in the centre of the test booth at a distance of 2 m from the façade at a height of 0.75 m above FFL. The reference air temperature must not be mixed up with the entering air temperature into the coil which may deviate due to the inevitable short-cut between leaving air 17 °C 26 °C and entering air. 2000 mm 33 34 Company | Technical innovation Company | Technical innovation Simulation of a room climate in the air flow laboratory Technical innovation arises in the Research & Development Centre of Kampmann Since 2008 the Research & Development Centre is adjacent to the headquarters of the Kampmann GmbH. It is one of the most modern facilities of its type and houses an air flow laboratory, a multipurpose laboratory and a sound chamber. The equipment is at the highest technical level and fulfills the customer's request for transparent product data. The R & D Centre (FEC) enables the company to develop new standard products continually improve its products undertake applied research provide detailed analysis of the units to be tested undertake standard tests. The in-house Research & Development Centre (FEC) at the headquarters in Lingen (Ems) Sound chamber 35 36 Company | Kampmann Company | Kampmann 37 Kampmann. With over 720 employees at 16 locations around the world, Kampmann is one of the major players in the construction and building services industries. Kampmann systems for heating, cooling and ventilation are at the forefront of different market segments today. Consistently there. Consistently cooperative. Consistently sophisticated. Consistently solution-focused. Kampmann GmbH has continuously evolved since Wherever our customers and partners We believe that fairness is the best We leave nothing to chance. Including A hotel needs a different climate than the company was founded in 1972. Exceptionally well need us: We are there. Around the foundation for sustainable success. the future. We check and recheck. We a retail outlet. And when the southern trained specialist personnel in Germany and Poland corner. Around the globe. On the web. That a handshake can mean more than enhance and optimize. And we don’t side of an office block needs to be cooled produces quality products for customers around We are there transforming today’s a 100-page contract. And that mutual let go until we are thoroughly satisfied. down, the north may still need warming the world. Kampmann took its first steps in the United challenges into tomorrow’s solutions. respect comes from seeing eye-to-eye. With a love for detail that is only up. Our customers’ requirements are Kingdom in 1983 and has been selling its products We are there when the standards and This is the way we are – and this is rivalled by our passion for thinking in highly specific. So are our solutions. Which there as Kampmann UK Ltd. since 2013. Kampmann norms of the future are defined. how we interact, with our customers, systems, we maintain and nurture means that even the trickiest challenges Heating, Cooling, Ventilation Ltd., established in 2016, Down-to-earth, attentive, available at with our suppliers, with each other: a our spirit of discovery and invention have a predictable (and most satisfying) is responsible for sales in the USA and Canada. any time. And always ready to go the cordial and sincere invitation to genuine that drives us from good ideas to outcome: We turn complexity into clarity extra mile. partnership. useful products. – and create the perfect climate. 38 Unternehmen | Kampmann Further products A selection of our product range International contact INT Kampmann GmbH T + 49 591 7108-660 | Kampmann.eu/contact/international Design Grilles Decorative air outlets for your underfloor trench system. Fan Coils Environmentally-friendly air conditioning of buildings for today and tomorrow. We have the right solution for every project. Contact Europe AT Kampmann GmbH Representative Office Austria T + 49 8141 3991-0 | Kampmann.at HU Kampmann GmbH Representative Office Hungary T + 36 309 214200 | Kampmann.hu BE Kampmann GmbH Representative Office BeNeLux-France T + 32 11 378467 | Kampmann.be IT Kampmann GmbH Representative Office Italy T + 39 0471 930158 | Kampmann.it CH Kampmann GmbH Representative Office Switzerland T + 41 44 2836185 | Kampmann.ch LU Kampmann GmbH Representative Office BeNeLux-France T + 32 11 378467 | Kampmann.lu DE Kampmann GmbH T + 49 591 7108-500 | Kampmann.de NL Kampmann GmbH Representative Office Netherlands T + 31 703114174 | Kampmann.nl DK Ribe Jernindustrie A/S T + 45 75 4202 55 | Kampmann-dk.dk PL Kampmann Polska Sp. z o. o. T + 48 24 7219185 | Kampmann.pl FR RU Kampmann GmbH Representative Office Moscow T + 7 495 3630244 | Kampmann.ru Kampmann GmbH Representative Office BeNeLux-France T + 33 975128216 | Kampmann.fr GB Kampmann UK Ltd. T + 44 1932 228592 | Kampmann.co.uk Unit Heaters As a wall-or ceiling-mounted unit for IE SE Curant Trading AB T + 46 19 16 74 90 | Kampmann-se.se Kampmann UK Ltd. T + 44 1932 228592 | Kampmann.co.uk heating, cooling or ventilation in large spaces, industrial halls, retail outlets and more, either as recirculating air or mixed air units. Door Air Curtains For controlled screening of air-conditioned premises with open doors and industrial doorways. Creates a comfortable indoor climate and minimises energy loss. Find more details and products here: Kampmann.eu Contact North America Contact China CA Kampmann Heating, Cooling, Ventilation Ltd. T + 1 604 362 0180 | Kampmann.ca CN Shanghai DaTao Science & Trading Co., Ltd. T + 86 21 6215 1458 | Kampmann.cn Kampmann.eu Kampmann GmbH Friedrich-Ebert-Str. 128 – 130 49811 Lingen (Ems) Germany T + 49 591 7108 -660 F + 49 591 7108 -173 E [email protected] W Kampmann.eu
© Copyright 2026 Paperzz