Analog in/output modules

SM 234,
AI 2x12Bit U, I,
AO 2x12Bit U, I
SM 234,
AI 3x12Bit U, I,
1x12Bit RTD,
AO 2x12Bit U, I
Ð Configurable,
Ð Configurable,
Ð Voltage, current
Ð Voltage, current,
Ð Resistance, Resistance
thermometer
Current consumption/power loss
Current consumption from backplane bus
Power loss
Technical data analog inputs
Number of inputs
Cable length, shielded
Rated load voltage
Current consumption from load voltage L+
(without load)
Voltage inputs
Min. input resistance (voltage range)
Input voltage ranges
Operational limit of voltage ranges
Basic error limit voltage ranges
Current inputs
Min. input resistance (current range)
Input current ranges
100 mA
2.9 W
100 mA
2W
2
DC 24 V
100 mA
4
DC 24 V
60 mA
9
9
100 k:
+1 V ... +5 V
0 V ... +10 V
-10 V ... +10 V
120 k:
+1 V ... +5 V
0 V ... +10 V
-10 V ... +10 V
-400 mV ... +400 mV
-4 V ... +4 V
+/-0.3% ... +/-0.7%
+/-0.2% ... +/-0.5%
9
+/-0.2% ... +/-0.6%
9
Operational limit of current ranges
Basic error limit current ranges
Resistance inputs
Resistance ranges
50 :
+4 mA ... +20 mA
0 mA ... +20 mA
-20 mA ... +20 mA
+/-0.3% ... +/-0.8%
-
Operational limit of resistor ranges
Basic error limit
Resistance thermometer inputs
-
90 :
+4 mA ... +20 mA
0 mA ... +20 mA
-20 mA ... +20 mA
+/-0.3% ... +/-0.8%
+/-0.2% ... +/-0.5%
9
0 ... 600 Ohm
0 ... 3000 Ohm
+/-0.4%
+/-0.2%
9
System 500S
Ð 4 inputs/2 outputs,
HMI
Ð 2 inputs/2 outputs,
Software
General information
Note
Features
234-1BD60
Accessories
Type
234-1BD50
Appendix
Order number
Figure
System 300S
Signal modules analog | Analog in/output modules
234-1BD50
234-1BD60
System 200V
System 100V
Analog in/output modules
System SLIO
Analog in/output modules | Signal modules analog
269
System SLIO
System 100V
System 200V
System 300S
System 500S
HMI
Software
Accessories
Appendix
270
Signal modules analog | Analog in/output modules
Signal modules analog | Analog in/output modules
234-1BD50
234-1BD60
Order number
Resistance thermometer ranges
Operational limit of resistance thermometer ranges
Basic error limit thermoresistor ranges
Thermocouple inputs
Thermocouple ranges
Operational limit of thermocouple ranges
Basic error limit thermoelement ranges
Programmable temperature compensation
External temperature compensation
Internal temperature compensation
Resolution in bit
Measurement principle
Basic conversion time
Noise suppression for frequency
Initial data size
Technical data analog outputs
Number of outputs
Cable length, shielded
Rated load voltage
Reverse polarity protection of rated load
voltage
Current consumption from load voltage L+
(without load)
Voltage output short-circuit protection
Voltage outputs
Min. load resistance (voltage range)
Max. capacitive load (current range)
Output volatge ranges
Operational limit of voltage ranges
Basic error limit voltage ranges
Current outputs
Max.in load resistance (current range)
Max. inductive load (current range)
Output current ranges
Operational limit of current ranges
Basic error limit current ranges
Settling time for ohmic load
Settling time for capacitive load
Settling time for inductive load
Resolution in bit
234-1BD50
-
-
234-1BD60
Pt100
Pt1000
Ni100
Ni1000
+/-0.4% ... +/-1.0%
16
Sigma-Delta
6.75 ms - 268 ms
50 Hz and 60 Hz
4 Byte
+/-0.2% ... +/-0.5%
16
Sigma-Delta
7 ms - 272 ms
50 Hz and 60 Hz
4 Byte
2
-
2
-
-
-
9
9
9
9
1 k:
1 µF
-10 V ... +10 V
+1 V ... +5 V
0 V ... +10 V
+/-0.2% ... +/-0.6%
9
1 k:
1 µF
-10 V ... +10 V
+1 V ... +5 V
0 V ... +10 V
+/-0.4% ... +/-0.8%
+/-0.2% ... +/-0.4%
9
500 :
10 mH
-20 mA ... +20 mA
+4 mA ... +20 mA
0 mA ... +20 mA
+/-0.3% ... +/-0.8%
0.05 ms
0.5 ms
0.1 ms
12
500 :
10 mH
-20 mA ... +20 mA
+4 mA ... +20 mA
0 mA ... +20 mA
+/-0.3% ... +/-0.8%
+/-0.2% ... +/-0.5%
0.3 ms
1 ms
0.5 ms
12
Weight
Environmental conditions
Operating temperature
Storage temperature
Certifications
UL508 certification
9
9
9
9
-
DC 4 V
DC 75 V/ AC 60 V
-
-
-
-
DC 75 V/ AC 60 V
-
-
DC 500 V
DC 500 V
25.4 mm x 76 mm x
88 mm
110 g
25.4 mm x 76 mm x
88 mm
100 g
0 °C to 60 °C
-25 °C to 70 °C
0 °C to 60 °C
-25 °C to 70 °C
yes
yes
System SLIO
System 300S
none
yes
no
yes, parameterizable
yes
possible
none
red SF LED
none
System 500S
none
yes
no
yes, parameterizable
yes
possible
green LED
red SF LED
none
HMI
234-1BD60
1.5 ms/channel
yes
4 Byte
Software
234-1BD50
2.5 ms/all channels
yes
4 Byte
Accessories
Order number
Conversion time
Substitute value can be applied
Output data size
Status information, alarms, diagnostics
Status display
Interrupts
Process alarm
Diagnostic interrupt
Diagnostic functions
Diagnostics information read-out
Supply voltage display
Group error display
Channel error display
Isolation
Between channels
Between channels of groups to
Between channels and backplane bus
Between channels and power supply
Max. potential difference between circuits
Max. potential difference between inputs
(Ucm)
Max. potential difference between Mana
and Mintern (Uiso)
Max. potential difference between inputs
and Mana (Ucm)
Max. potential difference between inputs
and Mintern (Uiso)
Max. potential difference between Mintern
and outputs
Insulation tested with
Mechanical data
Dimensions (WxHxD)
Appendix
Signal modules analog | Analog in/output modules
234-1BD50
234-1BD60
System 200V
System 100V
Analog in/output modules | Signal modules analog
271
System SLIO
System 100V
System 200V
Signal modules analog | Analog in/output modules
Connections, Interfaces
Signal modules analog | Analog in/output modules
234-1BD50
234-1BD60
234-1BD50
L+ DC 24 V
IN
IN
System 300S
OUT
OUT
Appendix
Accessories
Software
HMI
System 500S
234-1BD60
272
L+
Ð 0 (4) digital outputs,
Ð max. 3 counter,
Ð 4 analog inputs,
Ð 2 analog outputs
280 mA
2W
16
1000 m
600 m
DC 20.4...28.8 V
DC 0...5 V
DC 15...28.8 V
7 mA
9
1.5 mA
3 ms
3 ms
-
HMI
Current consumption/power loss
Current consumption from backplane bus
Power loss
Technical data digital inputs
Number of inputs
Cable length, shielded
Cable length, unshielded
Rated load voltage
Current consumption from load voltage L+
(without load)
Rated value
Input voltage for signal "0"
Input voltage for signal "1"
Input voltage hysterese
Frequency range
Input resistance
Input current for signal "1"
Connection of Two-Wire-BEROs possible
Max. permissible BERO quiescent current
Input delay of "0" to "1"
Input delay of "1" to "0"
Number of simultaneously utilizable inputs
horizontal configuration
Number of simultaneously utilizable inputs
vertical configuration
Input characteristic curve
Initial data size
Technical data digital outputs
Number of outputs
Cable length, shielded
System 500S
Ð 16 (12) digital inputs,
Software
General information
Note
Features
SM 238C,
digital input/output,
counter, analog input/
output
Accessories
Type
238-2BC00
16 Byte
4
1000 m
Appendix
Order number
Figure
System 300S
Signal modules analog | Combination modules
238-2BC00
System 200V
System 100V
Combination modules
System SLIO
Combination modules | Signal modules analog
273
System SLIO
System 100V
System 200V
System 300S
System 500S
HMI
Software
Accessories
Appendix
274
Signal modules analog | Combination modules
Signal modules analog | Combination modules
238-2BC00
Order number
Cable length, unshielded
Rated load voltage
Reverse polarity protection of rated load
voltage
Current consumption from load voltage L+
(without load)
Total current per group, horizontal configuration, 40°C
Total current per group, horizontal configuration, 60°C
Total current per group, vertical configuration
Output voltage signal "1" at min. current
Output voltage signal "1" at max. current
Output current at signal "1", rated value
Output current, permitted range to 40°C
Output current, permitted range to 60°C
Output current at signal "0" max. (residual
current)
Output delay of "0" to "1"
Output delay of "1" to "0"
Minimum load current
Lamp load
Parallel switching of outputs for redundant
control of a load
Parallel switching of outputs for increased
power
Actuation of digital input
Switching frequency with resistive load
Switching frequency with inductive load
Switching frequency on lamp load
Internal limitation of inductive shut-off
voltage
Short-circuit protection of output
Trigger level
Number of operating cycle of relay outputs
Switching capacity of contacts
Output data size
Technical data analog inputs
Number of inputs
Cable length, shielded
Rated load voltage
Reverse polarity protection of rated load
voltage
Current consumption from load voltage L+
(without load)
Voltage inputs
Min. input resistance (voltage range)
238-2BC00
600 m
5 mA
L+ (-0.8 V)
1A
yes, electronic
1.5 A
16 Byte
4
200 m
DC 24 V
60 mA
9
120 k:
Operational limit of resistance thermometer ranges
Basic error limit thermoresistor ranges
Thermocouple inputs
Thermocouple ranges
Operational limit of thermocouple ranges
Basic error limit thermoelement ranges
Programmable temperature compensation
External temperature compensation
Internal temperature compensation
Resolution in bit
Measurement principle
Basic conversion time
Noise suppression for frequency
Initial data size
Technical data analog outputs
Number of outputs
Cable length, shielded
Rated load voltage
Reverse polarity protection of rated load
voltage
Current consumption from load voltage L+
(without load)
Voltage output short-circuit protection
Pt100
Pt1000
Ni100
Ni1000
+/-0.4% ... +/-1.0%
+/-0.2% ... +/-0.5%
16
Sigma-Delta
7 ms - 272 ms
50 Hz and 60 Hz
8 Byte
2
200 m
DC 24 V
9
System SLIO
System 300S
System 500S
Operational limit of resistor ranges
Basic error limit
Resistance thermometer inputs
Resistance thermometer ranges
0 ... 600 Ohm
0 ... 3000 Ohm
+/-0.4%
+/-0.2%
9
HMI
Operational limit of current ranges
Basic error limit current ranges
Resistance inputs
Resistance ranges
90 :
+4 mA ... +20 mA
0 mA ... +20 mA
-20 mA ... +20 mA
+/-0.3% ... +/-0.8%
+/-0.2% ... +/-0.5%
9
Software
Operational limit of voltage ranges
Basic error limit voltage ranges
Current inputs
Min. input resistance (current range)
Input current ranges
238-2BC00
+1 V ... +5 V
0 V ... +10 V
-10 V ... +10 V
-400 mV ... +400 mV
-4 V ... +4 V
+/-0.3% ... +/-0.7%
+/-0.2% ... +/-0.5%
9
Accessories
Order number
Input voltage ranges
Appendix
Signal modules analog | Combination modules
238-2BC00
System 200V
System 100V
Combination modules | Signal modules analog
60 mA
9
275
System SLIO
System 100V
System 200V
System 300S
System 500S
HMI
Software
Accessories
Appendix
276
Signal modules analog | Combination modules
Signal modules analog | Combination modules
238-2BC00
Order number
Voltage outputs
Min. load resistance (voltage range)
Max. capacitive load (current range)
Output volatge ranges
Operational limit of voltage ranges
Basic error limit voltage ranges
Current outputs
Max.in load resistance (current range)
Max. inductive load (current range)
Output current ranges
Operational limit of current ranges
Basic error limit current ranges
Settling time for ohmic load
Settling time for capacitive load
Settling time for inductive load
Resolution in bit
Conversion time
Substitute value can be applied
Output data size
Status information, alarms, diagnostics
Status display
Interrupts
Process alarm
Diagnostic interrupt
Diagnostic functions
Diagnostics information read-out
Supply voltage display
Group error display
Channel error display
Isolation
Between channels
Between channels of groups to
Between channels and backplane bus
Between channels and power supply
Max. potential difference between circuits
Max. potential difference between inputs
(Ucm)
Max. potential difference between Mana
and Mintern (Uiso)
Max. potential difference between inputs
and Mana (Ucm)
Max. potential difference between inputs
and Mintern (Uiso)
238-2BC00
9
1 k:
1 µF
-10 V ... +10 V
+1 V ... +5 V
0 V ... +10 V
+/-0.4% ... +/-0.8%
+/-0.2% ... +/-0.4%
9
500 :
10 mH
-20 mA ... +20 mA
0 mA ... +20 mA
0 mA ... +20 mA
+/-0.3% ... +/-0.8%
+/-0.2% ... +/-0.5%
0.3 ms
1 ms
0.5 ms
12
1.50 ms
yes
4 Byte
yes
yes
yes, parameterizable
yes, parameterizable
yes
possible
green LED per group
red SF LED
none
9
9
DC 4 V
DC 75 V/ AC 60 V
DC 500 V
50.8 mm x 76 mm x
88 mm
150 g
0 °C to 60 °C
-25 °C to 70 °C
System SLIO
Software
HMI
System 500S
yes
Accessories
Weight
Environmental conditions
Operating temperature
Storage temperature
Certifications
UL508 certification
238-2BC00
-
Appendix
Order number
Max. potential difference between Mintern
and outputs
Insulation tested with
Mechanical data
Dimensions (WxHxD)
System 300S
Signal modules analog | Combination modules
238-2BC00
System 200V
System 100V
Combination modules | Signal modules analog
277
System SLIO
System 100V
System 200V
Signal modules analog | Combination modules
Connections, Interfaces
Signal modules analog | Combination modules
238-2BC00
238-2BC00
L+
L+
(A1)
(B1)
(A2)
(B2)
(A3)
Appendix
Accessories
Software
HMI
System 500S
System 300S
(B3)
278
(L1)
(L2)
(L3)
- DC 24 V