CDMA 1x vs EVDO RF Spec Comparison Agenda Sensitivity and Dynamic Range Single Tone Desensitization EVDO Intermodulation Spur CDMA 2000 Intermodulation Spur Adjacent Channel Selectivity Blocker RX Spurious Emission TX frequency accuracy TX hard handoff TX waveform quality factor Output Power Range Range of Closed Loop Power Control More Power Options VIA Telecom, Inc. Proprietary December 2005 2 Sensitivity and Dynamic Range CDMA 2000 EVDO VIA Telecom, Inc. Proprietary December 2005 3 Single Tone Desensitization CDMA 2000 EVDO VIA Telecom, Inc. Proprietary December 2005 4 EVDO Intermodulation Spur VIA Telecom, Inc. Proprietary December 2005 5 CDMA 2000 Intermodulation Spur VIA Telecom, Inc. Proprietary December 2005 6 Adjacent Channel Selectivity CDMA 2000 EVDO VIA Telecom, Inc. Proprietary December 2005 7 Blocker CDMA 2000 EVDO VIA Telecom, Inc. Proprietary December 2005 8 RX Spurious Emission CDMA 2000 EVDO VIA Telecom, Inc. Proprietary December 2005 9 TX frequency accuracy CDMA 2000 EVDO VIA Telecom, Inc. Proprietary December 2005 10 TX hard handoff CDMA2000 T1 < 2 ms, the time elapsed from the action time to the instant the mobile station transmit power, as measured at the mobile station antenna connector, on the old CDMA frequency assignment drops below -61 dBm/MHz T2 < 140 ms, the time elapsed from the action time to the instant the mobile station transmitter is enabled on the new CDMA frequency assignment. Transmit power after handoff RC1, RC2: RC3-6: EVDO Not found VIA Telecom, Inc. Proprietary December 2005 11 TX waveform quality factor • CDMA2000 (4.3.4.3) The waveform quality factor, ρ, shall be greater than 0.944 (excess power is less than 0.25 dB). The transmit time error, ˆτ , shall be within ±1 μs. Test 1: Îor = -75 dBm Test 2: Îor = -101 dBm Test 3: Handoff • EVDO (4.2.2): Test 1 (single carrier, Îor = -75 dBm) : the waveform quality factor, ρoverall , > 0.944 (excess power is less than 0.25 dB). Test 2 (subtype 3, multiple carrier, Îor = -75 dBm): the waveform quality factor, ρoverall , for each carrier, shall be greater than 0.933 (excess power is less than 0.30 dB). The transmit time error, ˆτ , shall be within ±1 μs. VIA Telecom, Inc. Proprietary December 2005 12 Output Power Range CDMA 2000 EVDO The testing conditions are identical (Ior). The Spectrum mask (RX spurious emission) is identical. VIA Telecom, Inc. Proprietary December 2005 13 Time Response of Open Loop Power Control The upper limit curves are identical. The lower limit hs 1 dB shift for the floor. •EVDO Lower limit: for t> 0 max [0.8 × |ΔPin| × [1 – e(1.67 - t)/36] - 2.0 dB, -1] - 1 dB; •CDMA2000 Lower limit: for t> 0 max [0.8 × |ΔPin| × [1 - e(1.25 - t)/36] 2.0 dB, 0] - 1 dB; VIA Telecom, Inc. Proprietary December 2005 14 Range of Closed Loop Power Control • EVDO: Condition: The closed loop power control range shall be at least ±24 dB around the open loop estimate. Speed: • • The interval from the end of the first ‘1’ power control bit after the 120 consecutive ‘0’ power control bits to the time the access terminal output power starts to decrease shall be no longer than 3.33 ms for Subtypes 0 and 1 Physical Layer and no longer than 13.33 ms for Subtype 2 Physical Layer. The average rate of change in mean output power shall be greater than 12 dB per 26.67 ms and less than 18 dB per 26.67 ms for Subtypes 0 and 1 Physical Layer and greater than 12 dB per 106.67 ms and less than 18 dB per 106.67 ms for Subtype 2 Physical Layer. Accuracy: the mean output power of the access terminal shall be within 0.3 dB of its final value in less than 500 μs. • CDMA Step size depends on the support accuracy 0.5 dB, 0.25 dB. The interval from the end of the first valid ‘1’ power control bit after the 100 consecutive ‘0’ valid power control bits to the time the mobile station output power starts to decrease shall be no longer than 2.5 ms. The average rate of change in mean output power for 9600 bps data rate shall be greater than 12.8 dB per 20 ms and less than 19.2 dB per 20 ms the mean output power of the mobile station shall be within 0.3 dB of its final value in less than 500 μs. The lower bit rate allows slower power adjustment speed. VIA Telecom, Inc. Proprietary December 2005 15 More Power Options Minimum Controlled Output Power: –50 dBm/1.23 MHz for both EVOD and CDMA2000. Standby Output Power for both EVDO and CDMA2000: When the transmitter is disabled, the output noise power spectral density of the access terminal shall be less than -61 dBm/1 MHz. Gated Output Power (CDMA2000 only). PRI Channel Output Power (EVDO only). Code Domain Power: CDMA2000: simpler: Both the real and imaginary components of code domain power in each inactive code channel shall be 23 dB or more below the total output power measured on both the I and Q carrier phase components combined. EVDO • DRC Channel Output Power • ACK Channel Output Power • Data Channel Output Power • DSC Channel Output Power Code Channel Accuracy: CDMA2000 only. VIA Telecom, Inc. Proprietary December 2005 16 Questions? VIA Telecom www.via-telecom.com
© Copyright 2026 Paperzz