LNG Flier

Accessories - Customized
Item
1
2
3
4
5
6
7
8
9
Description
Sensor block 1/2” NPT
Sensor block 1/8” NPT
U-Plate-80 mm
L-Plate
U-plate-104 mm
Support plate
Plate 75x75
Komp.fittings for Ø6
Clamping bracket
PTFE
304-1734
AISI 304
304-0833
304-0825
Alu.
1/4”NPT
1/2”NPT
304-0824
304-1728
304-1732
304-1731
304-1733
304-1729
307-1727
1/8”NPT
304-0273
304-0823
304-0274
High Precision Gas Tank Thermometers
E.g. LNG - BUTANE - PROPANE
• Leakage Detection
• Cool Down
• Gas Temperature
• Skin Temperature
• Boil of Gas
Calibration in one or more spots - in-house temperature laboratory
Example of calibration certificate
Senmatic Temperature Laboratory
Calibration in 3 and 4 spots - traceable certificate with
coefficients according to EN 60751.
Single spot calibration - traceable certificate.
EN 60751
Emerson Process Management
Rosemount Tank Radar AB - Box 13045 - SE-402 51 GÖTEBORG - SWEDEN
Tel: +46 313370000 - Fax: +46 31253022 - E-mail: [email protected] - www.rosemount-tg.com
COMPLETE INTRINSIC SAFE SENSOR SYSTEM:
Junction Box - Sensors - Transmitters
Resistance Thermometer - Type MNS
- Tank Thermometer
The stainless steel, (AISI 316) conical interface type FCR is the interface between almost any flange size and the Rosemount
2240S temperature transmitter designed as the connection to the MNS resistance thermometers.
Mineral insulated thermometer for temperature measurement in insulation and
concrete surroundings e.g. liquid gas tanks and LNG tanks (coiled diameter min.
1 m).
Measuring temp. range: -200°C to +100°C.
The measuring element is glass encapsulated platinum elements according to
EN60751.
Protective sheath of AISI 316L filled with compressed MgO powder. Sensor tip
Ø6 AISI 316L.
Response time (mean values) measured at velocities in:
water w. 0.4 m/s:
0.5 = 6.4 sec. - 0.9 = 27 sec.
Recommended measuring current: 1 mA (max. 2 mA).
Approvals: Ex ia IIC T6 Ga
Options include thermometers up 250 m in length, calibrated sensors certificates supplied with the Van-Dusen coefficients allowing overall system tolerances better than +/- 0,124 degree C within a temperature range of -195 degree C to -100 degree C.
The 2240S can connect up to 16 (or 8 duplex) 4 wire resistance thermometers.
Note:
Sensors need to be with minimum
450 mm lead wire.
Only 8 duplex sensors can be connected
in the transmitter.
Type-FCR
J
K
L
M
P
To achieve high accuracy we recommend the 4 wire calibrated version.
Each calibrated sensor is supplied with a certificate stating its own individual coefficients
Ro, A, B and C to substitute the standard coefficients in the EN60751 platinum curve.
By use of the coefficients the uncertainty of the sensor will be <=20 mK in the range -195
to 100 °C.The transmitter will represent the major part of the total system uncertainty.
.....
Flange size:
6 inch Class 150 ......
6 inch Class 300 ......
8 inch Class 150 ......
8 inch Class 300 ......
DN150 PN40 ...........
Larger flanges
on request
Type of conncetion:
1/8” NPT ...................
Type-TTA/5331D = ±
(0.2)2 + (0.02)2 °C = ± 0.201°C
1
Number of connections:
1 - 16 sensors ...................
(max. 8 when duplex sensors
V3.3
Type MNS
Sensor Length/L1
Min. 200 mm max. 300.000 mm
Optional length ......
Project No.
Max. 10 characters - customer def.
X
X
MNS TAG No. - Project No.
Max. 10 characters - customer def.
Outer Diameter
4.5 mm .............................. 5
6.0 mm .............................. 6
X
Number of elements:
Simplex ............................... S
Duplex .................................. D
Extention length L2
X ........ None
........ Min. 500 mm - max 10,000 mm
Wiring ( Number of conductors)
3 wire ........................................ 3
4 wire ........................................ 4
Connection Diagramm:
1. Element
White
Temperature range using van Dusen coefficients:
Calibrated sensors:
Temperature conversion 2240S
Ambient temperature conversion 2240S
Resolution 2240S
Calibrated RTD sensor
± 0.05 °C
± 0.05 °C
± 0.10 °C
± 0.02 °C
Total accuracy =
±
2
2
2
2
0.05 + 0.05 + 0.1 + 0.02
Uncalibrated sensors:
Pt100, EN60751, Class A, Tolerance ±0.15°C ±0.002 x |∆t|
Sensor tolerance at 0°C
Sensor tolerance at 100°C
Sensor tolerance at -165°C
Temperature conversion 2240S
± 0.15 °C
± 0.35 °C
± 0.48 °C
± 0.15 °C
Ambient temperature conversion 2240S
± 0.05 °C
Resolution 2240S
± 0.10 °C
Total accuracy at -165°C =
=
± 0.124 °C
±
0.052 + 0.052 + 0.12 + 0.482
=
± 0.50 °C
2×Red
2. Element
Yellow
2×Black
1. Element
White
2×Red
2. Element
2×Yellow 2×Black
Resistance at 0°C
100 .............................................
.............
.............
.............
.............
.............
Compression at L2:
None
1/8" NPT SS ferrule compression fitting
1/4" NPT SS ferrule compression fititng
½" NPT SS ferrule compression fitting
3/4" NPT SS ferrule compression fitting
..................
..................
..................
..................
..................
Compression at L1:
None
1/8" NPT SS ferrule compression fitting
1/4" NPT SS ferrule compression fititng
½" NPT SS ferrule compression fitting
3/4" NPT SS ferrule compression fitting
.......................
.......................
.......................
.......................
.......................
Compression at sensor tip:
None
1/8" NPT SS ferrule compression fitting
1/4" NPT SS ferrule compression fititng
½" NPT SS ferrule compression fitting
3/4" NPT SS ferrule compression fitting
0
1
2
3
4
1
Tolerance Class EN 60751
Grade A ............................................... 1
Grade B .............................................. 2
Calibrated - 4 wire only ....................... C
Sensor Tip
Ø6x60 ...................................................
0
1
2
3
4
A
0
1
2
3
4
Lead-out wire/cable
ETFE single wire ........................................... 1
PTFE cable ................................................... 2
PVC cable light blue (intrincic colour) ......... 3
Lead-out dimension:
Straight ............................................................
Ø6 ...................................................................
Ø10 ...............................................................
Ø12 ................................................................
0
1
2
3
Lead out protection:
0 ............................ None
1 ............................ Spring
2 ............................ Polyolefin flex
Cable Length/LK22
Min. 200 mm max. 300.000 mm
X ................................... Optional length