Special Safety Instruction 308016EN, Edition 5 April 2013 Tank Gauging System Special Safety Instruction P r oduc tDi s c ont i nue d www.rosemount-tg.com Special Safety Instruction 308016EN, Edition 5 April 2013 Rosemount TankRadar REX Table of Contents Contents SPECIAL SAFETY INSTRUCTION . . . . . . . . . . . . . . . . . . . . . TOC-II 1. GENERAL REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.1 1.2 1.3 2. EXPLOSION PROTECTION TECHNIQUES . . . . . . . . . . . . . . 2-1 2.1 2.2 2.3 2.4 2.5 3. SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 FLAMEPROOF/EXPLOSIONPROOF ENCLOSURES . . . . . . . . . . . . .1-2 NON-RECOGNIZED SPARE PARTS . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 INTRINSIC SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 FLAMEPROOF/EXPLOSION PROOF . . . . . . . . . . . . . . . . . . . . . . . . .2-2 INCREASED SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 EUROPEAN ATEX DIRECTIVE INFORMATION . . . . . . . . . . . . . . . . .2-3 2.4.1 Radar Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 2.4.2 Radar Tank Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4 2.4.3 Transmitter Interface Card (TIC) . . . . . . . . . . . . . . . . . . . .2-5 2.4.4 Temperature Multiplexer Card (TMC) . . . . . . . . . . . . . . . .2-6 2.4.5 FF Adaptor Card (FFA) . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7 2.4.6 Data Acquisition Unit (DAU) . . . . . . . . . . . . . . . . . . . . . . .2-8 2.4.7 Remote Display Unit 40 (RDU 40) . . . . . . . . . . . . . . . . . .2-9 IECEX CERTIFICATION INFORMATION . . . . . . . . . . . . . . . . . . . . .2-10 2.5.1 Radar Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-10 2.5.2 Radar Tank Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 2.5.3 Transmitter Interface Card (TIC) . . . . . . . . . . . . . . . . . . .2-12 2.5.4 Temperature Multiplexer Card (TMC) . . . . . . . . . . . . . . .2-13 2.5.5 FF Adaptor Card (FFA) . . . . . . . . . . . . . . . . . . . . . . . . . .2-14 2.5.6 Data Acquisition Unit (DAU) . . . . . . . . . . . . . . . . . . . . . .2-15 2.5.7 Remote Display Unit 40 (RDU 40) . . . . . . . . . . . . . . . . .2-16 SAFE CONNECTION OF TANKRADAR REX . . . . . . . . . . . . 3-1 3.1 3.2 3.3 3.4 CABLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 INTEGRATED JUNCTION BOX, JBI . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 CUSTOMER SUPPLIED JUNCTION BOX . . . . . . . . . . . . . . . . . . . . . .3-1 GROUNDING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 4. INSTALLATION OF ROSEMOUNT TANKRADAR REX ACCORDING TO UNDERWRITERS LABORATORY (UL) 4-1 TOC-i Special Safety Instruction Rosemount TankRadar REX Table of Contents 308016EN, Edition 5 April 2013 SPECIAL SAFETY INSTRUCTION This document lists specific requirements which have to be fulfilled to secure a safe installation and use of Rosemount TankRadar REX in hazardous area. Omission may jeopardize safety, and Rosemount Tank Radar AB will not take any responsibility if requirements as listed below are not fulfilled. TOC-ii Special Safety Instruction 308016EN, Edition 5 April 2013 Rosemount Tank Radar REX 1. General Requirements 1.1 Safety Instructions • The REX 3900 gauge must be installed by suitably trained personnel according to the accompanied instructions and in accordance with the applicable code of practice. • An “X” suffix on the approval number (e.g. Baseefa 03ATEX0071X) indicates that special conditions for safe use apply. • Make sure that the connected power supply is in accordance with the marking on the REX 3900 gauge. • Select external fuse rating with respect to area temperature classification (T1-T6) and maximum expected ambient temperature to prevent overheating of the W11 wiring (0.5 mm2), see Figure 3-1. Example: maximum allowed (fault) current in a T4 installation with 70°C ambient is 7.5 A according to the lead seal compartment certificate PTB 97 ATEX 1047 U. 1-1 Special Safety Instruction Rosemount Tank Radar REX Chapter 1 General Requirements 1.2 308016EN, Edition 5 April 2013 Flameproof/Explosionproof Enclosures Flameproof/Explosionproof enclosures of Radar Tank Gauges (RTG) may not be opened while energized. Rosemount Tank Radar AB will not take any responsibility for local regulations defining conditions when flame proof enclosures are allowed to be opened while energized. RTG3930_Flameproof.eps Flameproof enclosure Figure 1-1. Radar Tank Gauge with flameproof enclosure. 1.3 Non-Recognized Spare Parts Any substitution of non-recognized spare parts may jeopardize safety. Rosemount Tank Radar AB will not take any responsibility for faults, accidents, etc. caused by non-recognized spare parts. Recognized spare parts shall have or be packed with label with Rosemount Tank Radar AB name and identification number. 1-2 Special Safety Instruction 308016EN, Edition 5 April 2013 2. Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques Explosion Protection Techniques TankRadar REX equipment is often used in areas where flammable materials are handled and where an explosive gas atmosphere may be present, so called hazardous areas. To protect the environment and the personnel, precautions must be taken to ensure that this atmosphere cannot be ignited. Consequently, equipment within hazardous areas must be explosion protected. A number of different explosion protection techniques have been developed over the years. Intrinsic Safety, Flameproof/Explosionproof enclosures and Increased Safety are different techniques. The basic principles of explosion protection are: 2.1 • Flammable materials are grouped according to the energy needed to ignite them. • Equipment located in hazardous areas are classified according to the maximum surface temperature that it can produce and this must be safe with the flammable gases that may be present. • Hazardous areas are classified according to the probability that an explosive atmosphere is present, and this dictates whether or not a particular explosion protection technique may be used. Intrinsic Safety Intrinsic safety, IS, is based on the principle of restricting electrical energy available in hazardous-area circuits such that any sparks or hot surfaces, that may occur as a result of electrical faults in components, are unable to cause ignition. Intrinsic safety is the only technique accepted for Zone 0 hazardous areas. For example, temperature measurement with the DAU is intrinsically safe. Note! Special care and skills is necessary for troubleshooting in Intrinsically Safe circuits. Instruments for troubleshooting in Intrinsically Safe circuits must be approved for the intended use. 2-1 Special Safety Instruction Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.2 308016EN, Edition 5 April 2013 Flameproof/Explosion Proof Flameproof/Explosion proof enclosures can be used when an explosion is allowed inside the enclosure as long as it does not spread to the outside. The enclosure must be strong enough to withstand the pressure and must have narrow gaps to allow the pressure to escape without igniting the atmosphere outside the equipment. Note! 2.3 The flameproof/explosionproof enclosure must not be opened while the unit is powered or when an explosive gas atmosphere is present. Damaged enclosures must be taken out of service. All cover fastening screws must be present and firmly tightened. Increased Safety This type of protection is intended for products in which arcs and sparks do not occur in normal service nor under fault conditions, and in which excessive surface temperatures are prevented. Increased Safety is achieved by enhancing insulation values and creepage and clearance distances above those required for normal service, thus providing a safety factor against accidental breakdown. Electrical connections are carried out in such a way that self-loosening is not possible. 2-2 Special Safety Instruction 308016EN, Edition 5 April 2013 2.4 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques European ATEX Directive Information 2.4.1 Radar Unit The REX Radar Unit has been certified to comply with Directive 94/9/EC of the European Parliament and the Council as published in the Official Journal of the European Communities No. L 100/1. Figure 2-1. Certification label ATEX for the 2015 Radar Unit (used in 3900 series radar tank gauges). The following information is provided as part of the label of the radar unit: • Name and address of the manufacturer (Rosemount Tank Radar AB). • CE Conformity Marking • Complete model number • The serial number of the device • Year of construction • Marking for explosion protection: • Ex d IIB Gb T6 (-40 °C Ta +70 °C) • Baseefa(2001) ATEX certificate number: Baseefa03ATEX0071X Special Conditions for Safe Use (X): • The Type TH2015-2019 Radar Units are not to be mounted directly on to a tank. • For replacement purposes the cover fastening screws are to be of minimum grade A4-80 stainless steel. • The permanently attached cables are to be suitably terminated and protected against impact. 2-3 Special Safety Instruction Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.4.2 308016EN, Edition 5 April 2013 Radar Tank Gauge The 3900 Radar Tank Gauge (type TH2015-2019 Radar Unit with antenna certified for Zone 0) has been certified to comply with Directive 94/9/EC of the European Parliament and the Council as published in the Official Journal of the European Communities No. L 100/1. The 3900 series of Radar Tank Gauges is intended to be mounted directly on tank. Figure 2-2. Certification label ATEX for the 3900 Series Radar Tank Gauge. The following information is provided as part of the label of the radar tank gauge: • Name and address of the manufacturer (Rosemount Tank Radar AB). • CE Conformity Marking • Complete model number • The serial number of the device • Year of construction • Marking for explosion protection: • Ex d IIB Ga/Gb T6 (-40 °C Ta +70 °C) • Baseefa(2001) ATEX certificate number: Baseefa03ATEX0071X Special Conditions for Safe Use (X): 2-4 • For replacement purposes the cover fastening screws are to be of minimum grade A4-80 stainless steel. • The permanently attached cables are to be suitably terminated and protected against impact. Special Safety Instruction 308016EN, Edition 5 April 2013 2.4.3 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques Transmitter Interface Card (TIC) Figure 2-3. Certification label for the Transmitter Interface Card (TIC). The Transmitter Interface Card (TIC) is mounted within the flameproof enclosure. It is required for intrinsically safe inputs such as 4-20 mA current loops and local display unit. The following information is provided as part of the label of the TIC: • Name and address of the manufacturer (Rosemount Tank Radar AB) • CE Conformity Marking: • Year of construction • Marking for explosion protection: • [Ex ia] IIC (Ga) (-40 °C Ta +85 °C) • Baseefa(2001) ATEX EC-Type Examination Certificate number: Baseefa03ATEX0050U Schedule of Limitations Note! • The Transmitter Interface Card must be housed within an enclosure which provides a degree of protection of at least IP20. • The 0V connections must be interconnected and connected to an I.S. earth point in accordance with EN60079-14 12.2.4., when the component is installed within an assembly. • The arrangements for the connections to non-hazardous area and hazardous area external circuits must comply with the requirements of Clause 6.3 of EN 50020:2002. For electrical (I.S.) parameters refer to the appended EC-Type Examination Certificate Baseefa03ATEX0050U. 2-5 Special Safety Instruction Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.4.4 308016EN, Edition 5 April 2013 Temperature Multiplexer Card (TMC) Figure 2-4. Certification label for the Temperature Multiplexer Card (TMC). The Temperature Multiplexer Card (TMC) is mounted within the flameproof enclosure. It is used for connecting up to 6 temperature sensors to the REX 3900 gauge. The following information is provided as part of the label of the TMC: • Name and address of the manufacturer (Rosemount Tank Radar AB) • CE Conformity Marking: • Year of construction • Marking for explosion protection: • [Ex ia] IIC (Ga) (-40 °C Ta +85 °C) • Baseefa(2001) ATEX EC-Type Examination number: Baseefa03ATEX0050U Schedule of Limitations Note! 2-6 • The Temperature Multiplexer Card must be housed within an enclosure which provides a degree of protection of at least IP20. • The 0V connections must be interconnected and connected to an I.S. earth point in accordance with EN60079-14 12.2.4., when the component is installed within an assembly. • The arrangements for the connections to non-hazardous area and hazardous area external circuits must comply with the requirements of Clause 6.3 of EN 50020:2002. For electrical (I.S.) parameters refer to the appended EC-Type Examination Certificate Baseefa03ATEX0050U. Special Safety Instruction 308016EN, Edition 5 April 2013 2.4.5 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques FF Adaptor Card (FFA) Figure 2-5. Certification label for the FF Adaptor Card (FFA). The FF Adaptor card (FFA) is mounted within the flameproof enclosure. It is, in conjunction with a Fieldbus Communication Board (BAS01ATEX1385U), used to interface to an intrinsically safe Fieldbus. The following information is provided as part of the label of the FFA: • Name and address of the manufacturer (Rosemount Tank Radar AB) • CE Conformity Marking: • Year of construction • Marking for explosion protection: • [Ex ia] IIC (Ga) (-40 °C Ta +85 °C) • Baseefa(2001) ATEX EC-Type Examination Certificate number: Baseefa04ATEX0119U Schedule of Limitations Note! • The FF Adaptor Card must be housed within an enclosure which provides a degree of protection of at least IP20. If the FF Adaptor Card is mounted within a hazardous area it must be installed within an appropriately certified flameproof enclosure. • The arrangements for the connections to non-hazardous area and hazardous area external circuits must comply with the requirements of Clause 6.3 of EN 50020:2002. • The FF Adaptor Card is considered to be suitable for use within EEx d apparatus with an Ambient Temperature range of (-40 °C Ta +85 °C). For electrical (I.S.) parameters refer to the appended EC-Type Examination Certificate Baseefa04ATEX0119U. 2-7 Special Safety Instruction 308016EN, Edition 5 April 2013 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.4.6 Data Acquisition Unit (DAU) Figure 2-6. Certification label ATEX for the Data Acquisition Unit. The following information is provided as part of the label of the Data Acquisition Unit (DAU): • Name and address of the manufacturer (Rosemount Tank Radar AB) • CE Conformity Marking • Complete model number • The serial number of the device • Year of construction • Marking for explosion protection: • Ex ia IIB T4 Ga (-40 °C Ta +65 °C) X20 Pin 6 w.r.t Pin 7 X20 Pin 5 w.r.t Pin 7 X21 (For connection of up to 14 RTDs) Ui=14 V Ii=334 mA Pi=1.17 W Li=Ci=0 Ui=6 V Ii=60 mA Pi=0.08 W Li=Ci=0 U0=6 V I0=394 mA P0=1.25 W Ui=1.2 V Ii=10 mA Pi=0.02 W Li=0 Ci=13.5 F • 2-8 Baseefa(2001) ATEX EC-Type Examination Certificate number: Baseefa03ATEX0044 Special Safety Instruction 308016EN, Edition 5 April 2013 2.4.7 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques Remote Display Unit 40 (RDU 40) Figure 2-7. Approval label for the Remote Display Unit RDU40. The following information is provided as part of the label of the Remote Display Unit 40 (RDU 40): • Name and address of the manufacturer (Rosemount Tank Radar AB). • CE Conformity Marking: • Year of construction • Marking for explosion protection: • Ex ib IIC T4 Gb (-40 °C Ta +70 °C) • Sira ATEX certificate number: Sira 00 ATEX 2062 The following instructions apply to equipment covered by certificate number Sira 00ATEX2062: 1 The equipment may be used with flammable gases and vapours with apparatus groups IIC, IIB and IIA and with temperature classes T1, T2, T3 and T4. 2 The equipment is only certified for use in ambient temperatures in the range -40 °C to +70 °C and should not be used outside this range. 3 Installation shall be carried out in accordance with the applicable code of practice. 4 Repair of this equipment shall be carried out in accordance with the applicable code of practice. 5 Certification marking as detailed in drawing number 9150 074980. 2-9 Special Safety Instruction Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.5 308016EN, Edition 5 April 2013 IECEx Certification Information 2.5.1 Radar Unit The Type TH2015-TH2019 Radar Unit has been certified to comply with the following IEC Standards: • IEC 60079-0: 2007-10 Edition 5 • IEC 60079-1: 2007-04 Edition 6 • IEC 60079-26: 2006 Edition 2 Figure 2-8. Certification label IECEx for the Type TH2015-TH2019 Radar Unit (used in Type RTG3920-RTG3964 Radar Tank Gauge). The following information is provided as part of the label of the radar unit: • Name and address of the manufacturer (Rosemount Tank Radar AB) • Complete model number • The serial number of the device • Year of construction • Ex d IIB Gb T6 (-40 °C Ta +70 °C) • Baseefa(2001) IECEx Certificate of Conformity: No. IECEx BAS 04.0032X Special Conditions for Safe Use (X): 2-10 • The Type TH2015-2019 Radar Units are not to be mounted directly on a tank. • For replacement purposes the cover fastening screws are to be of minimum grade A4-80 stainless steel. • The permanently attached cables are to be suitably terminated and protected against impact. Special Safety Instruction 308016EN, Edition 5 April 2013 2.5.2 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques Radar Tank Gauge The Type RTG3920-RTG3964 Radar Tank Gauge has been certified to comply with the following IEC Standards: • IEC 60079-0: 2007-10 Edition 5 • IEC 60079-1: 2007-04 Edition 6 • IEC 60079-26: 2006 Edition 2 The Radar Tank Gauge has also been assessed to comply with Standard EN50284:1999. Figure 2-9. Certification label IECEx for the Type RTG3920-RTG3964 Radar Tank Gauge. The following information is provided as part of the label of the radar unit: • Name and address of the manufacturer (Rosemount Tank Radar AB) • Complete model number • The serial number of the device • Year of construction • Ex d IIB Ga/Gb T6 (-40 °C Ta +70 °C) • Baseefa(2001) IECEx Certificate of Conformity: No. IECEx BAS 04.0032X Special Conditions for Safe Use (X): • For replacement purposes the cover fastening screws are to be of minimum grade A4-80 stainless steel. • The permanently attached cables are to be suitably terminated and protected against impact. 2-11 Special Safety Instruction Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.5.3 308016EN, Edition 5 April 2013 Transmitter Interface Card (TIC) The Transmitter Interface Card has been certified to comply with the following IEC Standards: • IEC 60079-0: 2004 Edition 4 • IEC 60079-11: 2006 Edition 5 Figure 2-10. Certification label for the Transmitter Interface Card (TIC). The Transmitter Interface Card (TIC) is mounted within the flameproof enclosure. It is required for intrinsically safe inputs such as 4-20 mA current loops and local display unit. The following information is provided as part of the label of the TIC: • Name and address of the manufacturer (Rosemount Tank Radar AB) • Complete model number • Year of construction • [Ex ia] IIC (Ga) (-40 °C Ta +85 °C) • Baseefa(2001) IECEx Certificate of Conformity: No. IECEx BAS 04.0041U Schedule of Limitations: Note! 2-12 • The Transmitter Interface Card must be housed within an enclosure which provides a degree of protection of at least IP20. • The 0V connections must be interconnected and connected to an I.S. earth point in accordance with EN60079-14 12.2.4., when the component is installed within an assembly. • The arrangements for the connections to non-hazardous area and hazardous area external circuits must comply with the requirements of Clause 6.3 of IEC60079-11:1999. For electrical (I.S.) parameters refer to the appended IECEx Certificate of Conformity No. IECEx BAS 04.0041U. Special Safety Instruction 308016EN, Edition 5 April 2013 2.5.4 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques Temperature Multiplexer Card (TMC) The Temperature Multiplexer Card has been certified to comply with the following IEC Standards: • IEC 60079-0: 2004 Edition 4 • IEC 60079-11: 2006 Edition 5 Figure 2-11. Certification label for the Temperature Multiplexer Card (TMC). The Temperature Multiplexer Card (TMC) is mounted within the flameproof enclosure. It is used for connecting up to 6 temperature sensors to the Radar Unit. The following information is provided as part of the label of the TMC: • Name and address of the manufacturer (Rosemount Tank Radar AB) • Complete model number • Year of construction • [Ex ia] IIC (Ga) (-40 °C Ta +85 °C) • Baseefa(2001) IECEx Certificate of Conformity: No. IECEx BAS 04.0041U Schedule of Limitations: Note! • The Temperature Multiplexer Card must be housed within an enclosure which provides a degree of protection of at least IP20. • The 0V connections must be interconnected and connected to an I.S. earth point in accordance with EN60079-14 12.2.4., when the component is installed within an assembly. • The arrangements for the connections to non-hazardous area and hazardous area external circuits must comply with the requirements of Clause 6.3 of IEC60079-11:1999. For electrical (I.S.) parameters refer to the appended IECEx Certificate of Conformity No. IECEx BAS 04.0041U. 2-13 Special Safety Instruction Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.5.5 308016EN, Edition 5 April 2013 FF Adaptor Card (FFA) Figure 2-12. Certification label IECEx for the FF Adaptor Card (FFA). The FF Adaptor card (FFA) is mounted within the flameproof enclosure. It is, in conjunction with a Fieldbus Communication Board (BAS01ATEX1385U), used to interface to an intrinsically safe Fieldbus. The following information is provided as part of the label of the FFA: • Name and address of the manufacturer (Rosemount Tank Radar AB) • Complete model number • Year of construction • [Ex ia] IIC (Ga) (-40 °C Ta +85 °C) • Baseefa(2001) IECEx Certificate of Conformity No. IECEx BAS 05.0006U Schedule of Limitations Note! 2-14 • The FF Adaptor Card must be housed within an enclosure which provides a degree of protection of at least IP20. If the FF Adaptor Card is mounted within a hazardous area it must be installed within an appropriately certified flameproof enclosure. • The arrangements for the mounting of the pcb must not reduce the segregation and the connections to nonhazardous area and hazardous area external circuits must comply with the requirements of Clause 6.3 of IEC60079-11:1999. • The FF Adaptor Card is suitable for use within an Ambient Temperature range of -40 °C Ta +85 °C. For electrical (I.S.) parameters refer to the appended IECEx Certificate of Conformity No. IECEx BAS 05.0006U. Special Safety Instruction 308016EN, Edition 5 April 2013 2.5.6 Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques Data Acquisition Unit (DAU) The Temperature Multiplexer Card has been certified to comply with the following IEC Standards: • IEC 60079-0: 2007-10 Edition 5 • IEC 60079-11: 2006 Edition 5 Figure 2-13. Certification label IECEx for the Data Acquisition Unit. The following information is provided as part of the label of the Data Acquisition Unit: • Name and address of the manufacturer (Rosemount Tank Radar AB) • Complete model number • The serial number of the device • Year of construction • Ex ia IIB T4 Ga (-40 °C Ta +65 °C) • Baseefa(2001) IECEx Certificate of Conformity No. IECEx BAS 04.0040 Special Conditions for Safe Use: • Note! None For electrical (I.S.) parameters refer to the appended IECEx Certificate of Conformity No. IECEx BAS 04.0040. 2-15 Special Safety Instruction Rosemount Tank Radar REX Chapter 2 Explosion Protection Techniques 2.5.7 308016EN, Edition 5 April 2013 Remote Display Unit 40 (RDU 40) Figure 2-14. Approval label for the Remote Display Unit RDU40. The following information is provided as part of the label of the Remote Display Unit 40 (RDU 40): 2-16 • Name and address of the manufacturer (Rosemount Tank Radar AB) • Year of construction • Ex ib IIC T4 Gb (-40 °C Ta +70 °C) • Sira IECEx certificate number: Sir 05.0021 Special Safety Instruction 308016EN, Edition 5 April 2013 Rosemount Tank Radar REX Chapter 3 Safe Connection of TankRadar REX 3. Safe Connection of TankRadar REX 3.1 Cabling The permanently attached cables are to be suitably terminated and protected against impact. On the REX gauge this must be applied for cable outputs W11 and W12. Intrinsically Safe W11 Cabling.eps W12 Non-intrinsically Safe Figure 3-1. Enclosure with output W11 and W12. 3.2 Note! Integrated Junction Box, JBi The cover of the Integrated Junction Box may not be opened while energized. The intrinsically safe wiring to the internal TIC/TMC Board at output W12, must be adequately segregated from the nonintrinsically safe wiring to output W11. 3.3 Customer Supplied Junction Box Customer supplied junction box, used for connection of output W11 to customers field cabling, must be certified for use in hazardous area. Leads from Radar Tank Gauge to junction box must be protected according to national code of practice. The intrinsically safe wiring to the internal TIC/TMC Board at output W12, must be adequately segregated from the nonintrinsically safe wiring to output W11. 3-1 Special Safety Instruction Rosemount Tank Radar REX Chapter 3 Safe Connection of TankRadar REX 3.4 308016EN, Edition 5 April 2013 Grounding TH3900_GroundLug.eps The housing must be grounded according to national code of practice. Normally this means that the grounding lug on the flameproof enclosure is connected to a potential equalizing network, normally the tank shell. Figure 3-2. Grounding lug. If the enclosure is connected to a tank structure without a potential equalizing network, the protective ground with the power supply must not be connected. 3-2 Special Safety Instruction 308016EN, Edition 5 April 2013 4. Rosemount Tank Radar REX Chapter 4 Installation of Rosemount TankRadar Installation of Rosemount TankRadar REX According to Underwriters Laboratory (UL) The enclosed "SYSTEM CONTROL DRAWING FOR HAZARDOUS LOCATION INSTALLATION" drawing number 9150072-966, shows specific requirements which have to be fulfilled to secure a safe installation and use of Rosemount TankRadar REX in hazardous area. The approval plate on explosion proof enclosure indicates installed options. Omission may jeopardize safety, and Rosemount Tank Radar AB will not take any responsibility if requirements in the drawing are not fulfilled. 4-1 D + - T1 T2 T3 T4 T5 T6 T6 T7 T8 RTD cables: Shielded, max length 100m. See note 1. DP or DAU cable: shielded, max length 100m. See note 1. Single element temperature sensor connections (1-3 RTDs). RTD3 RTD2 RTD1 Multiple element temperature sensor connections (1-6 RTDs). RTD1 RTD2 RTD3 RTD4 RTD5 RTD6 Intrinsically Safe Display Panel + - Multiple element temperature sensor connections (1-14 RTDs). Slave Data Acquisition Unit Type DAU 2100 - DAU 2114 + - + - Single element temperature sensor connections (1-14 RTDs). X20 Internal lead seals. Alternative connections with SDAU instead of directly connected RTDs (Radar Unit without TMC). Reference resistor 20 < R < 200 Ohm > 0.3 W X21 Unused wires to be terminated securely. W11 CHANGE ORDER No WEEK WEEK ISSUE CHANGE ORDER No WEEK TIC TIC TIC TIC TIC TIC TIC TIC TIC TMC Note 5. Note 6. 25.2 25.2 25.2 25.2 12.6 12.6 5.88 11.76 11.76 5.88 96.0 96.0 96.0 96.0 0 0 54.0 216.0 270.0 177.0 0.62 0.62 0.62 0.62 7.4 7.4 1055 6.5 6.5 1015 13.50 13.50 13.50 13.50 44.0 3.0 2.80 3.50 Voc, Vdc Isc, mA Ca, uF La, mH Ain 1+ & Gnd Ain 2+ & Gnd Ain 1+ & Ain 1Ain 2+ & Ain 2Ain 1- & Gnd Ain 2- & Gnd DS & Gnd D+ & Gnd DS & D+ & Gnd All Ch & Gnd Channel 0025 6 GU-LN ALL DIMENSIONS ARE IN MILLIMETRES. TOLERANCES, UNLESS OTHERWISE STATED: WEEK APPROVED BY FILE SYSTEM CONTROL DRAWING TITLE 1 ST ANGLE SCALE SHEET 5 1/2 ISSUE Rosemount Tank Radar AB, Sweden The copyright/ownership of this document is and will remain ours. The document must not be used without our authorization or brought to the knowledge of a third party. Contravention will be prosecuted. 9150 072-966 DWG NO. OrCAD for hazardous location installation of FINISH, UNLESS Rosemount TRL2 Radar Tank Gauge OTHERWISE STATED: DOC. TYPE 0025 23 (Rex) PRODUCT CODE WEEK ISSUED BY GU-RJ Note 1. Make sure a continous electric path exists from the cable shield to Radar Unit chassis. Shorter cables may be specified for performance reasons. See installaton manual. Note 2. W12 is optional and may contain up to 15 wires connected to six separate intrinsically safe circuits. Separation between different IS circuits must be maintained in junction boxes. Note 3. The WBS 500 from Oy Labkotec AB is an acceptable alternative. Note 4. The intrinsically safe wiring must be in accordance with the National Electrical Code ANSI/NFPA 70, NEC Article 504 and ANSI/ISA RP12.6. In Canada, the installation must be in acordance with the Canadian Electrical Code, CEC Part 1. Note 5. The ground of the radar unit must be connected to earth ground of the AC feeder supply circuit. The resistance between the ground lug and the earth ground must be less than 1 ohm. Note 6. The radar unit must not be powered by or connected to equipment that uses or generates more than 250V RMS with respect to earth ground. Note 7.The outputs at W12 are intrinsically safe "ia" for use in Class I, Zone 1, Group IIB; Class I, Division 1, Groups C and D Hazardous Locations. Note 8. Intrinsically safe apparatus must be simple apparatus or be third party approved such that: Voc <= Vmax, Isc <= Imax, Ca >= Ci + Ccable and La >= Li + Lcable. Note 9. For Ccable and Lcable, if the capacitance per foot or the inductance per foot is not known, then the following values shall be used: Ccable = 60pF / foot and Lcable = 0.2uH / foot. Wiring must be protected by explosionproof (flexible) conduit. 1 2 3 4 5 6 7 8 9 10 GNYE (Customer supply) CHANGE ORDER No SME-2523 0025 3 SME-2632 0116 SME-5634 0711 ENTITY PARAMETERS (See applicable notes also) Board 2 5 ISSUE MAINS L/L1/+ MAINS N/L2/FIELDBUS A FIELDBUS B RELAY K1A RELAY K1B RELAY K2A RELAY K2B AOUT+ (optional) AOUT- (optional) PROT. EARTH 9934 0323 Explosionproof Junction Box SME-2224 SME-3147 NON-IS CONNECTIONS Wiring to be protected by conduit or metallic flexible hose for EMC reasons. W12 Note 2, 7, 8. IS CONNECTIONS 1 4 ISSUE Radar Unit type TH 2015 - TH 2019 with options "TIC" and "TMC" HAZARDOUS LOCATION Class I, Div.1, Group C or D Class I, Zone 1, Group IIB Intrinsically Safe Junction Box 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 (Option, customer supply) To optional IS 4-20 mA Transmitters as above. AIN 1+ AIN 1AIN 2+ AIN 2DS D+ DGND T1 T2 T3 T4 T5 T6 T7 T8 (Customer supply) Intrinsically Safe Junction Box Note 4, 9. RTD1 + - RTD2 Intrinsically Safe 4-20 mA Transmitter Note 3. RTD1 1 2 3 4 5 6 7 8 9 RTD3 Intrinsically Safe 4-20 mA Transmitter Note 3. RTD2 1 2 3 4 5 6 7 8 9 RTD3 40 41 42 RTD14 1 2 3 4 5 6 7 8 9 DAU BUS DAU PWR DAU GND 1 2 3 4 5 6 7 8 ORIGINAL SIZE A3 RTD14 40 41 42 43 44 45 HiRef 4-2 9150 072-966 Rosemount Tank Radar REX Chapter 4 Installation of Rosemount TankRadar Special Safety Instruction 308016EN, Edition 5 April 2013 D + - T1 T2 T3 T4 T5 T6 T6 T7 T8 RTD cables: Shielded, max length 100m. See note 1. DP or DAU cable: shielded, max length 100m. See note 1. Single element temperature sensor connections (1-3 RTDs). RTD3 RTD2 RTD1 Multiple element temperature sensor connections (1-6 RTDs). RTD1 RTD2 RTD3 RTD4 RTD5 RTD6 Intrinsically Safe Display Panel Multiple element temperature sensor connections (1-14 RTDs). 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Slave Data Acquisition Unit Type DAU 2100 - DAU 2114 + - + - (Option, customer supply) 1 4 ISSUE Single element temperature sensor connections (1-14 RTDs). X20 WEEK TIC TIC TIC TIC TIC TIC TMC WEEK 0025 0711 Channel 3 ISSUE SME-2632 CHANGE ORDER No Channel Note 5. Note 6. FF-A & FF-B WEEK 0116 96.0 96.0 0 54.0 216.0 270.0 177.0 0.62 13.50 0.62 13.50 7.4 1055 44.0 6.5 3.0 6.5 2.80 1015 3.50 380 0 0 0025 6 ALL DIMENSIONS ARE IN MILLIMETRES. TOLERANCES, UNLESS OTHERWISE STATED: FILE SYSTEM CONTROL DRAWING TITLE 1 ST ANGLE SCALE SHEET 5 2/2 ISSUE Rosemount Tank Radar AB, Sweden The copyright/ownership of this document is and will remain ours. The document must not be used without our authorization or brought to the knowledge of a third party. Contravention will be prosecuted. 9150 072-966 DWG NO. OrCAD for hazardous location installation of FINISH, UNLESS Rosemount TRL2 Radar Tank Gauge OTHERWISE STATED: DOC. TYPE GU-LN PRODUCT CODE 0025 23 (Rex) WEEK APPROVED BY WEEK GU-RJ ISSUED BY Note 1. Make sure a continous electric path exists from the cable shield to Radar Unit chassis. Shorter cables may be specified for performance reasons. See installaton manual. Note 2. W12 is optional and may contain up to 15 wires connected to six separate intrinsically safe circuits. Separation between different IS circuits must be maintained in junction boxes. Note 3. The WBS 500 from Oy Labkotec AB is an acceptable alternative. Note 4. The intrinsically safe wiring must be in accordance with the National Electrical Code ANSI/NFPA 70, NEC Article 504 and ANSI/ISA RP12.6. In Canada, the installation must be in acordance with the Canadian Electrical Code, CEC Part 1. Note 5. The ground of the radar unit must be connected to earth ground of the AC feeder supply circuit. The resistance between the ground lug and the earth ground must be less than 1 ohm. Note 6. The radar unit must not be powered by or connected to equipment that uses or generates more than 250V RMS with respect to earth ground. Note 7.The outputs at W12 are intrinsically safe "ia" for use in Class I, Zone 1, Group IIB; Class I, Division 1, Groups C and D Hazardous Locations. Note 8. Intrinsically safe apparatus must be simple apparatus or be third party approved such that: Voc <= Vmax, Isc <= Imax, Ca >= Ci + Ccable and La >= Li + Lcable. Note 9. For Ccable and Lcable, if the capacitance per foot or the inductance per foot is not known, then the following values shall be used: Ccable = 60pF / foot and Lcable = 0.2uH / foot. 30 Vmax [Vdc] Imax [mA] Ci [uF] Li [mH] 25.2 25.2 12.6 5.88 11.76 11.76 5.88 Voc [Vdc] Isc [mA] Ca [uF] La [mH] Ain 1+ & Gnd Ain 1+ & Ain 1Ain 1- & Gnd DS & Gnd D+ & Gnd DS & D+ & Gnd All Ch & Gnd Note 10. As defined in IEC 61158-2 and IEC 60079-27 (FISCO). Wiring must be protected by explosionproof (flexible) conduit. 1 2 3 4 5 6 7 8 9 10 GNYE MAINS L/L1/+ MAINS N/L2/FIELDBUS A FIELDBUS B RELAY K1A RELAY K1B RELAY K2A RELAY K2B AOUT+ (optional) AOUT- (optional) PROT. EARTH FFC (Customer supply) SME-2523 SME-5634 CHANGE ORDER No ENTITY PARAMETERS (See applicable notes also) Board 2 5 ISSUE Board Explosionproof Junction Box 9934 0323 W11 Reference resistor 20 < R < 200 Ohm > 0.3 W X21 Unused wires to be terminated securely. CHANGE ORDER No SME-2224 SME-3147 NON-IS CONNECTIONS Wiring to be protected by conduit or metallic flexible hose for EMC reasons. Internal lead seals. Alternative connections with SDAU instead of directly connected RTDs (Radar Unit without TMC). IS CONNECTIONS W12 Note 2, 7, 8. Radar Unit type TH 2015 - TH 2019 with options "TIC", "TMC" and FFA/FFC. Intrinsically Safe Junction Box To optional IS 4-20 mA Transmitters as above. AIN 1+ AIN 1FB-A FB-B DS D+ DGND T1 T2 T3 T4 T5 T6 T7 T8 (Customer supply) Intrinsically Safe Junction Box Note 4, 9. RTD1 + - RTD2 + - 1 2 3 4 5 6 7 8 9 RTD3 Intrinsically Safe Fieldbus System Note 10. RTD1 1 2 3 4 5 6 7 8 9 DAU BUS DAU PWR DAU GND 1 2 3 4 5 6 7 8 Intrinsically Safe 4-20 mA Transmitter Note 3. RTD2 1 2 3 4 5 6 7 8 9 RTD3 40 41 42 RTD14 HAZARDOUS LOCATION Class I, Div.1, Group C or D Class I, Zone 1, Group IIB RTD14 40 41 42 43 44 45 HiRef 308016EN, Edition 5 April 2013 9150 072-966 ORIGINAL SIZE A3 Special Safety Instruction Rosemount Tank Radar REX Chapter 4 Installation of Rosemount TankRadar 4-3 Special Safety Instruction Rosemount Tank Radar REX Chapter 4 Installation of Rosemount TankRadar 4-4 308016EN, Edition 5 April 2013 Special Safety Instruction 308016EN, Edition 5 April 2013 Rosemount Tank Gauging local representative: Emerson Process Management Rosemount Tank Gauging Box 130 45 SE-402 51 Göteborg SWEDEN Tel (International): +46 31 337 00 00 Fax (International): +46 31 25 30 22 E-mail: [email protected] www.rosemount-tg.com Copyright © Rosemount Tank Radar AB. Ref. no: 308016EN, Edition 5. April 2013.
© Copyright 2026 Paperzz