Product Data Sheet: Damcos™ BRCF 8000

Product Data Sheet
March 2013
SD 0307-2E07
Damcos BRCF 8000
™
Hydraulic Single-Acting Balanced Rotary Actuator 90°
(Quarter-turn) Fail-Safe
TM
Data sheet
BRCF 8000 - Hydraulic single-acting balanced rotary actuator 90° fail-safe
™
ValveDamcos
adaption:
BRCF 8000
March 2013
Adjustment screw, torque: 50 Nm
6.5°
Main Dimensions
6.5°
Max. valve
shaft intrusion:
105
Actuator shown in closed (fail-safe) position.
Approx. 5°
Adapter
Fastning nut, torque: 320 Nm
All dimensions in mm
Intermediate
flange
Limits for the machining of the adapter. Other shapes on
request, please contact DMS.
Shape
5
Ø
Machined acc. to:
mm (max.):
DIN 6885
Ø 95
Performance
Torque
break away
opening 4800
end closing 2400
135
bar
(n
turn
g re
n
i
r
Sp
DIN 79
80
All dimensions
in mm.
Spring action
Performance:
Nm
10
Nm
4800
orm
al
wo
rkin
gp
res
sur
break away
closing
op
en
Hydraulic action
d
se
clo
e)
2400 end opening
Operation
port (B)
0°
closed
90°
open
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Note!
The BRCF fail safe actuator is “Fail Close” in the standard version. Optionally a “Fail Open “ version can be ordered. In case of Fail
Open the above torque curve and operation chart is opposite.
Standard version; Fail close;
Opens by means of hydraulic pressure applied to port B and closes with spring force, when pressure on B port is released.
Optional version; Fail Open;
Closes by means of hydraulic pressure applied to port A and opens with spring force, when pressure on port A is released.
2/2
2
SD 0307-2E02 Feb. 2002
Damcos™ BRCF 8000
March 2013
Data sheet
Valve
AdaptionBRCF 8000 - Hydraulic single-acting balanced rotary actuator 90° fail-safe
Valve adaption:
Adjustment screw, torque: 50 Nm
6.5°
Max. valve
shaft intrusion:
105
6.5°
Approx. 5°
Adapter
Fastning nut, torque: 320 Nm
All dimensions in mm
Intermediate
flange
Limits for the machining of the adapter. Other shapes on
request, please contact DMS.
Shape
5
Ø
Machined acc. to:
mm (max.):
DIN 6885
Ø 95
Technical
Specification
Performance:
Working pressure
Burst test
135 kg)
Total dry weight incl. mounting set (26.9
bar
(n
Oil displacement
Temperature range
Rotation
end closing 2400
Hydraulic media
and viscosities
Nm
675 bar
break away
opening 4800
turn
g re
n
i
r
Sp
4800
290 kg
orm
al
DIN 79
80
Spring action
Torque 135 bar
Nm
10
break away
closing
op
en
Hydraulic action
d
se
clo
1.6 l
wo
rkin to +80°C
-20°C
gp
90°±1°
res
sur
e)
2400 end opening
We recommend acid-free
hydraulic oil.
Viscosity range: 15-200 cSt.
For recommended brands and for other media than oil please refer to sepaOperation
rate data sheet.
port (B)
0°
closed
90°
open
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
3
2/2
SD 0307-2E02 Feb. 2002
Damcos™ BRCF 8000
Product Data Sheet
SD 0307-2E07
March 2013
©2013 Emerson Process Management. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Co. Damcos® and the Damcos
logotype are registered trademarks of Damcos A/S, Rosemount® TankRadar and the Rosemount
logotype are registered trademarks of Rosemount Tank Radar AB.
Emerson Process Management
Damcos A/S
Aaderupvej 41
DK-4700 Naestved
T +45 5578 7200
F +45 5578 7272
www.EmersonProcesss.com/mtm
TM
The contents of this publication are presented for information purposes only, and while effort has
been made to ensure their accuracy, they are not to be construed as warranties or guarantees,
expressed or implied, regarding the products or services described herein or their use or
applicability. Standard Terms and Conditions of Sale can be issued by contacting
Damcos A/S or Rosemount Tank Radar AB. We reserve the right to modify or improve the designs
and specifications of our products at any time without notice.
Damcos A/S and Rosemount Tank Radar AB accepts no responsibility for any errors that may
appear in this publication.