Product Data Sheet SD 1503-2E05 November 2009 Power controlled LPU system Product Data Sheet SD 1503-2E05 November 2009 Power control LPU system Description Power controlled LPU has internal control ensuring stop of electrical motor, when the valve has reached end position or if the valve is locked in intermediate positions. LPU-S can maintain an open position on a spring actuator by restarting the pump in case of a pressure loss. The control of the units in the system is carried out with hardwire in star connection from a relay- or PLC substation. Each LPU is connected to a control console with one cable only and is controlled only by the operating voltage. In power controlled versions the valve position signals (switches or 4-20 mA loop powered) are led directly to the substation. Position indication signals The position indicator is built into the pump block with internal wiring from position indicator to the circuit board mounted in the LPU electrical encapsulation (except for KFR). Potentiometer for analogue position indication, or 2 micro-switches for end-position indication are available. Position indication signal: Data sheet - - - Continuous: Power control LPU system ON/OFF: Cable: Continuous: For analogue position indication signals, two wires are required. For ON/OFF indication signal, one common wire and one wire each for open and for closed signal are required. ON/OFF switches are limited to 2.5 VA resistive load. Please refer to separate data sheet. 4-20mA 24V DC 2 wire transmitter Max 2.5 VA switches Min. 5 x 1.5 mm Min. 6 xout 1.5with mm hardwire in star connection Power controlled LPU has internalON/OFF: control carried Damcos recommends standard cable, 7 x 1.5 mm² ensuring stop of electrical motor, when the from a relay- or PLC substation. valve has reached end position or if the valve Each LPU is connected to a control console Cable diameter: is locked in intermediate positions.ø 12.5 - 20.5 mmwith one cable only and is controlled only by LPU-S can maintain an open position on a the operating voltage. spring actuator by restarting the pump in case In power controlled versions the valve position of a pressure loss. signals (switches or 4-20 mA loop powered) The control of the units in the system is are led directly to the substation. Description: Electrical specification This unit has to be controlled directly 230Vdirectly AC, with This unit has to be with controlled Electrical specification: 230V AC, 50 or 60 Hz. 50 or 60 Hz. 2 containing motor A cable e.g. 7 x motor 1,5 mmcontrol A cable e.g. 7 x 1,5 mm containing and control and position indicator signal is drawn position indicator signal is drawn from the control cabinet to each LPU from unit.the control cabinet to each LPU unit. Circuit board wiring diagram for power controlled LPU Position indication signals: 2 The position indicator is built into the pump block with internal wiring from position indicator to the circuit board mounted in the LPU electrical encapsulation (except for KFR). Potentiometer for analogue position indication, or 2 micro-switches for end-position indication are available. - For analogue position indication signals, two wires are required. For ON/OFF indication signal, one common wire and one wire each for open and for closed signal are required. ON/OFF switches are limited to 2.5 VA resistive load. Please refer to separate data sheet. Product Data Sheet SD 1503-2E05 November 2009 Data sheet Power control LPU system Power controled LPU system Operation LPU-S Opening: The LPU-S requires only 2 wires for Operation LPU-S: tions, the solenoid valve may be connected and controlled separately. If the control is built up so that the the soleClosing: When system the LPU is de-energized, LPU “open” terminal is energized whennoid valve opens and the oil flow from actuator to ever the valve is to be open. An interruptank, which causes that the spring closing actuator tion in the power supply will cause the closes valve. This function may used as failmotor stops. The valve is kept open by a solenoid LPUthe motor to restart as soon as thebe power safe.is reconnected. This will be avoided by valve, preventing-theIfoil from internal flowing leakage back into thetime a minor over tank. causes the pressure to fall below the preset defining the system so that only the the control system is builtIfup that the LPU pressure switch level, the pump will restart - If solenoid valve is energized. theso valve run forover 7 sec., keeping leaves terminal the required position, the control the valve “open” is energized whenever - If a minor internal and leakage timethus causes theup the pressure. This does not affect the position must readjust the valvein position by sup issystem to be open. An interruption the power pressure to fall below the preset pressure switch re-connecting thepower supply to the of the valve. ply will cause the LPU motor to restart as soon as level, the pump will restart and run for 7 sec., thus - If you want to obtain intermediate posi“open” terminal. the power is reconnected. This will be avoided ON/OFF-operation. When the LPU-S is energized, it opens valve,for runs for 7 sec. Opening: The LPU-S requires onlythe 2 wires extra, and then the motor stops. The valve is ON/OFF-operation. When the LPU-S is energized, it kept open by a solenoid valve, preventing the opens the valve, runs forflowing 7 sec.back extra, and oil from into thethen tank.the keeping up the pressure. This does not affect the position of the valve. If you want to obtain intermediate positions, the the LPU is de-energized, solenoid valve Closing may be: When connected and controlled the solenoid valve opens and the oil flow from separately. actuator to tank, which causes that the spring closing actuator closes the valve. This function may be used as fail-safe. by defining the system so that only the solenoid valve is energized. If the valve leaves the required position, the control system must readjust the valve position by re-connecting, the power supply to the “open” terminal. Electrical LPU-S The motor/pump The starts directly bystarts means of power motor/pump directly by means of Electrical LPU-S: on “open” terminal. power on “open” terminal. Themotor timer stops motor ifhas the expressure has The timer stops the if the the pressure exceeded pressure switch setThis point for 7 ceeded the pressure switchthe set point for 7 sec. sec. This circuit ensures high safety on the circuit ensures high safety on the LPU. Furthermore, LPU. Furthermore, a thermal safety is built a thermal safety is built into the motor. into the motor. When the valve is open and the pressure drops beWhen the valve is open and the pressure low set point, there is an automatic restart. drops below set point, there is an automatic The solenoid valve will keep the unit in open position restart. as long as the unit has powervalve on. will keep the unit in open The solenoid position as long as the unit has power on. Operation LPU-D Opening / Closing: LPU-D requires only 3 wires to operate the valve. When the motor is energized, it opens or closes the valve, dependent on the activation of the solenoid valve, runs for a further 7 sec., and then stops. The valve is locked in position by a double pilot operated check valve, preventing the oil from flowing back into the tank. If you wish to obtain intermediate positions, the motor and the solenoid valve are simply de-energized when the required position has been reached. Note: To prevent automatic restart after blackout, Damcos recommends to take away the power for 30 sec. after the valve has reached end position. 3 dependent on the activation of the solenoid valve, runs for a further 7 sec., and then stops. The valve is locked in position by a double pilot operated check valve, preventing the oil from flowing back into the tank. If you wish to obtain intermediate positions, the motor and the solenoid valve are simply de-energized when the required position has been reached. reached end position. Product Data Sheet SD 1503-2E05 November 2009 Power control LPU system The motor/pump starts directly by means of Electrical LPU-D Electrical LPU-D: power on - open or close. If the pressure exceeds 70 bar for 7 sec. the timer stops the The motor/pump starts directly by means of power motor/pump. on - open or close. If the pressure exceeds 70 bar This circuit ensures a high safety on the LPU. for 7 sec. the timer stops the motor/pump. This circuit ensures a high safety on the LPU. LPU with LED Postion Indicator The LED Position Indicator in the top cover can be powered by: - Directly via the ON/OFF position indicator (com monly DPI-E), if the signal back to the inputs may be 24VDC respectively 0V. - From the ON/OFF position indicator outputs in PD527, with the 0VDC connected to the common anode of the LED. - From customer specified output. Under all circumstances, 24VDC power to the LED must be available in LPU. Digrams for LPU with LED Postion Indicator PD527 Controlled power LPU with LED Indication - Option 1 High = 24V 4/5 SD 1503-2E02 Sep. 2002 4 Low = 0V Product Data Sheet SD 1503-2E05 November 2009 Power control LPU system External Controlled power LPU with LED Indication - Option 2 High = 24V Low = 0V External Controlled power LPU with LED Indication - Option 3 High = 24V Low = 0V 5 Product Data Sheet SD 1503-2E05 November 2009 Power control LPU system External Controlled power LPU with LED Indication - Option 4 Closed = 0-3% valve pos. Open = 97-100% Valve pos. 6 Product Data Sheet SD 1503-2E05 November 2009 Power control LPU system System layout The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos and the Damcos logotype are registered trademarks of Damcos A/S. All rights reserved. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs and specifications of our products at any time without notice. Damcos A/S accepts no responsibility for any errors that may appear in this publication. This product is developed and managed by: Emerson Process Management Damcos A/S Aaderupvej 41 DK-4700 Naestved T +45 5578 7200 F +45 5578 7272 © 2008 Damcos A/S For global contacts: www.EmersonProcess.com/marine
© Copyright 2026 Paperzz