Product Data Sheet SD 8612-2E01 August 2008 Damcos Analog Indicators ® Product Data Sheet SD 8612-2E01 August 2008 Damcos Analog Indicators ® sheet Analog indicators Advantages ntages: - iption: 4 - 20 mA input. - 4 - 20 mA input. - range Temperature range to +50°C. Temperature from -25°C tofrom -25°C 2 instrument sizes: 96 x 96 mm and +50°C. 144 x 96 144x mm withand 90° or 240° scale. 2 instrument sizes: 96 mm Approved by the maritime 144 x 144 mm with 90° or 240° scale. classification societies. Approved by the maritime classification - Accuracy: Class 1.5. societies. - Customer specified scales. Accuracy: Class 1.5. - Interchangeable scale on the 90° types. Customer specified scales. Interchangeable scale on the 90° types. DMS electrical indicators to be applied in Description connection with level and tank contents gauging. DKMS electrical indicators to be applied in connection with levelInstrument and tank contents gauging. to house corrensponds DIN-43700. The boxes are made of magnetic Instrument house to sheetcorrensponds metal, which provides additional protection external magneticsheet fields. An DIN-43700. The boxes against are made of magnetic important additional feature for instruments mounted in metal, which provides protection against panels with other electrical feature equipment. external magnetic fields. An important for instruments mounted in panels with other electrical equipment. Instruments are supplied with small frames according to DIN-43718. The standard colour is black RAL 9005. At Instruments are supplied frames accordrequest gray with framesmall RAL 7037 is available. ing to DIN-43718. The standard The colour is black RALinstruments 9005. At request accuracy of the corrensponds to class 1.5. I.e. the max. gray frame RAL 7037 is available. tolerated error is ± 1.5 % of the final scale and any measurement. The accuracyvalue, of thefor instruments corrensponds to class 1.5. I.e. the max. tolerated error is ± 1.5 % of will withstand 20 % the final scaleThe andinstruments value, for any measurement. continuous current overload. The instruments will withstand 20 % continuous current overload. ications: Input: Internal resistance: Front dimensions: Accuracy: Ambient temperature: Protection class: Mounting position: 2 The standard test voltage is 2000 V - 50 Hz for one minute. The standard test voltage is 2000 V - 50 Hz for one The class 1.5 measuring instrument operate minute. between -25° C and +50° C. however, the temperature range, according to international The class 1.5 measuring instrument standards allowed for guaranteed accuracy operate beliestween between 10°CCand and+50° 30° C.C. however, the temperature -25° range, according to international standards allowed Thefor instruments withstand minimum guaranteed accuracy lies between 10° C and 30° vibrations of ± 0.25 mm amplitude at a C. frequency of 50 Hz, corrensponding to 2.5g. The vibrations may be imposed in 3 mutually The instruments withstand minimum vibrations of ± perpendicular directions for 20 minutes. 0.25 mm amplitude at a frequency of 50 Hz, corren- 2.5g. shocks in 3 mutual Thesponding instrumenttowithstand The vibrations may be imposed in 3 mutually perperpendicular directions, even when applying 5 consecutive at anfor acceleration of pendicularshocks directions 20 minutes. 15 g. This is achieved by high quality shockproof spring pivots. withstand shocks in 3 mutual perThe instrument pendicular directions, even when applying 5 consecutive shocks at an acceleration of 15 g. This is achieved by high quality shock-proof spring pivots. 4 - 20 mA 40 ohm 96 x 96 mm and 144 x 144 mm Class 1.5 -25° C to +50° C The degree of protection of the enclosure is IP-54. The normal execution of our instruments is for vertical mounting ±5°. Product Data Sheet SD 8612-2E01 August 2008 Damcos Analog Indicators ® Specifications Input: 4 - 20 mA Internal resistance: 40 ohm Front dimensions: 96 x 96 mm and 144 x 144 mm Accuracy: Class 1.5 Ambient temperature: -25° C to +50° C Protection class: The degree of protection of the enclosure is IP-54. Mounting position: The normal execution of our instruments is for vertical mounting ±5°. Maritime approvals Lloyd’s Register of Shipping Det Norske Veritas Bureau Veritas Ordering instructions Following details to be informed when ordering: Size of instrument: 96 x 96 mm 144 x 144 mm Scale: 90° or 240° Scaling data 3 s: Lloyd’s Register of Shipping Det Norske Veritas Bureau Veritas ons: Following details to be informed when ordering: ® Size of instrument: 96 x 96 mm or 144 x 144 mm Scale: 90° or 240° Scaling data Product Data Sheet SD 8612-2E01 August 2008 Damcos Analog Indicators Dimensions B C A A Panel cut-out B Max. 10.0 Panel or similar All dimensions in mm Model: PR 96S PR144S A 96 x 96 144 x 144 B 92 x 92+0.8 138 x 138+1 C 59 57 ility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to d that such alterations can be made without subsequential changes being necessary in specifications already agreed. property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos and the Damcos logotype are registered trademarks of Damcos A/S. All rights reserved. The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs and specifications of our products at any time without notice. Damcos A/S accepts no responsibility for any errors that may appear in this publication. This product is developed and managed by: Emerson Process Management Damcos A/S Aaderupvej 41 DK-4700 Naestved T +45 5578 7200 F +45 5578 7272 SD 8612-2E01 Mar. 2001 © 2008 Damcos A/S For global contacts: www.EmersonProcess.com/marine 3/3
© Copyright 2024 Paperzz