Instruction Sheet PN 1700737 July 2011/RevA Baseefa pH Sensor Hazardous Area Installation Baseefa Installation Drawing Basefa Certificate Number: Baseefa10ATEX0156X Non-Hazardous Hazardous (Classified) Location ATEX & IECEx Any Approved Single Multi-Channel Barrier or Apparalus II 1 G Ex ia IIC T4 Ga (-20° < Ta < +60°C) ENTITY PARAMETERS (FOR SENSERS WITH PREAMPS) Vt = 13.1V, It = 500mA Pmax = 700mW Ci = 0.3 μF, Ii = 0mH SENSOR 6. pH & AMPERMETRIC SENSORS WITHOUT PREAMPS ARE SIMPLE APPRARATUS. 5. INSTALLATION MUST BE IN ACCORDANCE WITH ARTICLE 500 OF THE NEC (ANSI/NFPA 70) AND ANSI/ISA RP 12.6. WARNING: SUBSTILUTION OF COMPONENTS MAY INPAIR INTRINSIC SAFETY. 4. SINGLE MULTI-CHANNEL IS BARRIER OR APPARATUS MANUFACTURE'S CONTROL DRAWINGS MUST BE FOLLOWED WHEN INSTALLING THE SYSTEM. IS BARRIER OR EQUIPMENT MAY BE INSTALLED WITHIN THE HAZARDOUS (CLASSIFIED) LOCATION FOR WHICH IT IS APPROVED. 3. SINGLE MULTI-CHANNEL IS BARRIER OR APPARATUS MUST BE APPROVED, 2. Vmax > Vt; Imax > It; (Ci OF ALL LOOPS + C CABLE) < Ca; (Li OF ALL LOOPS + L CABLE) < La, Pmax OR Pi > P0. 1. NO REVISION TO THIS DRAWING IS PERMITTED WITHOUT AGENCY APPROVAL. NOTES: UNLESS OTHERWISE SPECIFIED TITLE SCHEMATIC, INSTALLATION, I. S. SENSOR, ATEX SIZE DWG NO C 1400334 SCALE: NONE WEIGHT: The pH sensors listed below can be used with this installation drawing. Sensors may or may not contain an integral preamplifier. 3900/VP 3500/VP 3300HT/VP 3400HT/VP 396/VP 396R/VP 396P/VP 398R/VP 399/VP 389/VP 385/385+ REV A SHEET 1 OF 2 Sample Labels ROSEMOUNT WARNING Analytical EXPLOSION HAZARD ® Irvine, CA, USA ELECTROSTATIC Only clean with damp cloth. 1 Pressurized spray injury Assembled in Mexico Model#3500-PR-02-10-21-30 RTD Pt100 Soft. Ver. ____ SQ#10123 SO#81000123 SN:B10-1245078-002 A/M 3500P-PR-02-10-21-30- 2 1180 II 1 G BAS: 9241722-00/A CSA: 9241723-00/A FM: 9241724-00/A (BAR CODE) 1 Information from other agencies may appear on this label. 2 These are data fields; information may vary from what is shown. Baseefa10ATEX0156X IECEx BAS 10.0083X Ex ia IIC T4 Ga (-20°C < Ta < 60°C) TITLE LABEL, INFORMATION, SENSOR, BASEEFA SIZE DWG NO REV A B 9241722-00 extracted from drawing 9241722-00 SCALE: NONE ROSEMOUNT ® Anal An l y tical MODEL SN Baseefa10ATEX0156X IECEx BAS 10.0083X Ex ia IIC T4 Ga (-20°C < Ta < 60°C) II 1 G 1 See manual. 1180 (BAR CODE) WEIGHT: SHEET 1 OF 1 to 105°C (140°C) 6 barg 1 See manual. Made in USA Information from other agencies may appear on this label. TITLE LABEL, SENSOR 3800/3800VP, BASEEFA REV 9241728-00 A B SIZE DWG NO extracted from drawing 9241728-00 Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com © Rosemount Analytical Inc. 2011 SCALE: 1:1 WEIGHT: SHEET 1 OF 1
© Copyright 2025 Paperzz