3 Installation Instruction DOC.QC4.PNC.1 Rev B October 2015 Control Modules Replacing pneumatic cartridge. OK! - The SA and DA pneumatic cartridges can be exchanged for re-configuration purposes (from SA to DA and vice versa) as well as for repair. - The DA-FILP pneumatic cartridge can only be exchanged by an identical cartridge for repair purposes, otherwise it will not function properly. - See Installation guide DOC.IG.QC41.1 for further installation instructions. Replacement procedure: - Before starting check that all the required parts are included. Kit contents: Pos. Qty. 1 2 3 4 5 1 1 1 1 1 1 1x 2x 3X or 4X 4x 4x Part nr. QX2-E2 FQX2-E4 QX2-E6 QX2-E1 QX2-E3 QX2-E5 Description Single acting Double acting Double acting FILP Single acting Double acting Double acting FILP O-ring Pneumatic connector M4 washer M4X30 hex.Socket screw 4 Before replacing the pneumatic cartridge, check the Orings are in place. 4 5 5 5 5 5 5 Entry BSP BSP BSP NPT NPT NPT 4X 4X 1 Loosen the fasteners with a 3 mm Allen key. 4X 4X 6 6 6 6 6 6 3 Before replacing the pneumatic cartridge, check that the pneumatic connectors are not captured in the housing. 4 4 4 SA / DA FILP SA / DA FILP SA / DA FILP SA / DA 3X SA / DA 3X 3X FILP 4X FILP 4X 4X 3X 4X 2X 3X 4X 6 Gently place the cartridge into the module. 2 Pull the cartridge out of the module. 3 3 3 3 3 3 FILP 3X 4X 5 Check if all holes contain connectors with O-rings. 4X 4X 2 2 2 2 2 2 SA / DA OK! 7 Fasten the screws according to the sequence below, with a 3 mm Allen key. OK! OK! OK! OK! 7 7 7 7 7 7 3 2 2 2 2 2 OK! 2 2X 13 4 4 4 4 4 4 1Nm 31 (8.85 In.lbf.) 1Nm 13 (8.85 In.lbf.) 1Nm 1 (8.85 In.lbf.) 3 1Nm (8.85 In.lbf.) 13 1Nm (8.85 In.lbf.) 1 1Nm (8.85 In.lbf.)