TorqPlusTM Electric Valve Actuators and Controls TorqPlusTM Electric Actuators MODEL EM-SR5 Torque 300 IN/LB – 1,600 IN/LB The Engineered Solution STANDARD FEATURES Bettis TorqPlus has taken the lead in offering compact, cost effective Spring Return Electric Actuator Packages. Three models offer a variety of solutions when one needs to protect a system upon loss of power. These actuators have been designed for dampers, small butterfly, ball and plug valves. The Model EM-SR5 Series is designed for use in environments where automatic closing/opening is required upon loss of power, with a rugged versatility that is hard to beat. When power is available, the device operates like a normal quarter turn, open/close or modulating actuator. Under powered operation, the spring pack travels with the movement of the actuator. Under powered stopped conditions, the actuator and spring are held in position via the electric mechanical brake. Upon loss of power, the spring is released and drives the actuator to the predesignated failsafe position. The failsafe positioning can be provided for either the CCW limit or to the CW limit. ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Two year warranty Heater and thermostat Case hardened steel spur gear train is permanently lubricated Operating temperatures: -40° F, with standard heater activated, to +140° F Thermally protected permanent split capacitor motor Electromechanical brake CW or CCW spring return Dual 1/2-inch NPT conduit entrances Captive hex bolts on enclosure Operational in any mounting orientation Limit switches with independent end of travel cams Male output drive on all models or female DIN/ISO F04 or F05 output drive on 10, 15 and 30 second models Adjustable mechanical stop at the fail safe position Visual position indicator Enclosure certified to weatherproof C.S.A. specifications that conform to NEMA type 1, 2, 3, 3R, 4, 4X and 12 OPTIONAL FEATURES ■ ■ ■ ■ ■ ■ Modulating service (separate enclosure) Standard 1KΩ potentiometer, other ranges provided upon request Optional 220 VAC 50/60 Hz motor Up to four auxiliary switches with adjustable cams Canadian Standard Association general purpose for electrical certification available under file #LR90062 Dual purpose weatherproof and explosion-proof enclosures are certified by Canadian Standards Association for services: Class I Groups C,D, Division I; Class II Groups E,F,G Division I that conform to NEMA type 7 and 9 MODEL EM-SR5 SERIES Torque Torque (against spring) (with spring) Model in/lb nm in/lb nm SR5-10 SR5-15 SR5-30 SR5-90 300 400 600 1600 34 45 68 181 350 450 700 1400 40 51 79 158 Speed (sec/90°) Motor Spring 10 15 30 90 4 5 6 25 LRA 0.69 0.69 0.35 0.35 Motor Ratings FLA Duty Cycle 0.34 0.34 0.30 0.30 100% 100% 100% 100% Weight (lbs) 28-30 28-30 36-38 138 TorqPlusTM Electric Actuators MODEL EM-SR5 Torque 300 IN/LB – 1,400 IN/LB Brake Position Indicator Motor Output Drive Shaft Terminal Strip Capacitor Heater & Thermostat O-Ring Seal Limit Switch Dual Conduit Connections Adjustable Spring Stop DIN-ISO Mounting/ Female Drive EM-SR5-90 with Gear Reduction Box Bettis Electric Mansfield, OH U.S.A. © 2002 Emerson. All rights reserved. 5M/01-02 T419-529-4296 Website: www.EmersonProcess.com Bulletin #88.10 TorqPlusTM Electric Actuators MODEL EM-SR5-10 EM-SR5-15 9 3/4 7 3/4 4 1/8 POSITION INDICATOR 3 3/4 SEE NOTE 1 13 13/16 1 5/8 15 3/8 1/2 NPT CONDUIT ENTRANCES 8 3/8 SPRING RETURN PACK F04 OUTPUT ADAPTER F04 FEMALE OUTPUT DRIVE 1 5/8 CLOCKWISE SPRING RETURN MECHANICAL STOP .79 COUNTER CLOCKWISE SPRING RETURN MECHANICAL STOP MALE OUTPUT DRIVE 2.75 DIA. 3/8-16 X .50 TAP (4) HOLES 1.170 .630 SQUARE 2.50 DIA. .585 1.414 .707 .585 .746 DIA. 1.170 FEMALE F04 OUTPUT MOUNTING .707 5/16-24 X .63 TAP (4) HOLES .556 ACROSS CORNERS MIN. 1.414 MALE OUTPUT MOUNTING .437 SQUARE X .50 DEEP .433 F04 OUTPUT DRIVE VIEW NOTE: 1) ADD 4.75 TO OVERALL DIMENSION FOR COVER REMOVAL Bettis Electric 2500 Park Avenue West, Mansfield, OH 44906 U.S.A. T419-529-4296 F419-529-4484 Website: www.EmersonProcess.com E-Mail: [email protected] © 2002 Emerson. All rights reserved. 5M/01-02 Bulletin #85.15 Assembly Layout Drawings MODEL EM-SR5-30 9 3/4 7 15/16 4 1/8 POSITION INDICATOR 3 3/4 SEE NOTE 1 16 1/8 14 3/16 1.63 1/2 NPT CONDUIT ENTRANCES 9 1/8 SPRING RETURN PACK 1 15/16 F05 OUTPUT ADAPTER F05 FEMALE OUTPUT DRIVE CLOCKWISE SPRING RETURN MECHANICAL STOP COUNTER CLOCKWISE SPRING RETURN MECHANICAL STOP 1.02 MALE OUTPUT DRIVE 3.50 DIA. .748 SQUARE 3.25 DIA. .958 DIA. 1.392 .696 1.810 1/4-20 X .50 TAP (4) HOLES .905 .696 1.392 .905 FEMALE F05 OUTPUT MOUNTING 1.810 MALE OUTPUT MOUNTING .713 ACROSS CORNERS MIN. .561 SQUARE .63 DEEP .556 F05 OUTPUT DRIVE NOTE: 1) ADD 4.75 TO OVERALL DIMENSION FOR COVER REMOVAL 3/8-24 X .79 TAP (4) HOLES TorqPlusTM Electric Actuators DT BG3 10 3/16 MODEL EM-SR5-90 12 9/16 POSITION INDICATOR 22 1/2 SPRING RETURN MECHANICAL STOP 1/2-20 TAPPED .87 DEEP 4 HOLES ON 3.06 DIA. B.C. 2 5/32 1 1/4 1 5/64 17 1/2 NPT CONDUIT ENTRANCES SQ 1 5/64 .984 2 5/32 NOTE: 1) ADD 4.75 TO OVERALL FOR COVER REMOVAL MALE OUTPUT DRIVE SPRING RETURN PACK BEVEL GEAR ACTUATOR Bettis Electric 2500 Park Avenue West, Mansfield, OH 44906 U.S.A. T419-529-4296 F419-529-4484 Website: www.EmersonProcess.com E-Mail: [email protected] © 2002 Emerson. All rights reserved. 5M/01-02 Bulletin #85.15 Bettis Electric 2500 Park Avenue West Mansfield, OH 44906 U.S.A. T 419-529-4296 F 419-529-4484 Website: www.EmersonProcess.com E-Mail: [email protected] Bettis USA P.O. Box 508 Waller, TX 77484 U.S.A. T 281-463-5100 F 281-463-5103 Website: www.EmersonProcess.com E-mail: [email protected] Bettis UK Ltd. 3 Furze Court 114 Wickham Rd. Fareham, Hampshire PO 16 7SH T 44-1329-848-900 F 44-1329-848-901 Bettis Canada Ltd. 4112-91 A Street Edmonton, Alberta T6E 5V2 Canada T 780-450-3600 F 780-450-1400 Bettis France: 325, Rue de Villeneuve Silic – BP 40434 94583 RUNGIS, France T 331-49-797300 F 331-49-797399 Bettis Int’l Sales Office: Calgary, Canada Rheinberg, Germany New Bombay, India Singapore Important: Due to Emerson’s continuing commitment to engineered product advancement, data presented herein is subject to change. Certified dimensional drawings and wiring diagrams are available on request. Consult factory with model designation and serial number. Bettis Bulletin # 10.10 Rev: 02/02 © 2002 Emerson. All rights reserved. 5M/02/02
© Copyright 2026 Paperzz