Model EM SR5

TorqPlusTM
Electric Valve
Actuators
and Controls
TorqPlusTM Electric Actuators
MODEL EM-SR5
Torque 300 IN/LB – 1,600 IN/LB
The Engineered Solution
STANDARD FEATURES
Bettis TorqPlus has taken the lead in offering compact,
cost effective Spring Return Electric Actuator Packages.
Three models offer a variety of solutions when one needs
to protect a system upon loss of power. These actuators
have been designed for dampers, small
butterfly, ball and plug valves.
The Model EM-SR5 Series
is designed for use in
environments where automatic closing/opening
is required upon loss of
power, with a rugged
versatility that is hard
to beat.
When power is
available, the
device operates like
a normal quarter turn,
open/close or modulating
actuator. Under powered operation, the spring pack travels with
the movement of the actuator.
Under powered stopped
conditions, the actuator and
spring are held in position
via the electric mechanical
brake. Upon loss of power, the
spring is released and drives the
actuator to the predesignated
failsafe position. The failsafe
positioning can be provided for
either the CCW limit or to the
CW limit.
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Two year warranty
Heater and thermostat
Case hardened steel spur gear train is
permanently lubricated
Operating temperatures:
-40° F, with standard heater activated, to +140° F
Thermally protected permanent split capacitor motor
Electromechanical brake
CW or CCW spring return
Dual 1/2-inch NPT conduit entrances
Captive hex bolts on enclosure
Operational in any mounting orientation
Limit switches with independent end of travel cams
Male output drive on all models or female
DIN/ISO F04 or F05 output drive on 10, 15 and 30
second models
Adjustable mechanical stop at the fail safe position
Visual position indicator
Enclosure certified to weatherproof C.S.A. specifications that conform to NEMA type 1, 2, 3, 3R, 4,
4X and 12
OPTIONAL FEATURES
■
■
■
■
■
■
Modulating service (separate enclosure)
Standard 1KΩ potentiometer, other ranges
provided upon request
Optional 220 VAC 50/60 Hz motor
Up to four auxiliary switches with adjustable cams
Canadian Standard Association general purpose for
electrical certification available under file #LR90062
Dual purpose weatherproof and explosion-proof
enclosures are certified by Canadian Standards
Association for services: Class I Groups C,D,
Division I; Class II Groups E,F,G Division I that
conform to NEMA type 7 and 9
MODEL EM-SR5 SERIES
Torque
Torque
(against spring)
(with spring)
Model
in/lb
nm
in/lb
nm
SR5-10
SR5-15
SR5-30
SR5-90
300
400
600
1600
34
45
68
181
350
450
700
1400
40
51
79
158
Speed (sec/90°)
Motor Spring
10
15
30
90
4
5
6
25
LRA
0.69
0.69
0.35
0.35
Motor Ratings
FLA Duty Cycle
0.34
0.34
0.30
0.30
100%
100%
100%
100%
Weight
(lbs)
28-30
28-30
36-38
138
TorqPlusTM Electric Actuators
MODEL EM-SR5
Torque 300 IN/LB – 1,400 IN/LB
Brake
Position Indicator
Motor
Output
Drive Shaft
Terminal
Strip
Capacitor
Heater &
Thermostat
O-Ring Seal
Limit Switch
Dual Conduit
Connections
Adjustable
Spring Stop
DIN-ISO Mounting/
Female Drive
EM-SR5-90 with
Gear Reduction Box
Bettis Electric
Mansfield, OH U.S.A.
© 2002 Emerson. All rights reserved. 5M/01-02
T419-529-4296
Website: www.EmersonProcess.com
Bulletin #88.10
TorqPlusTM Electric Actuators
MODEL EM-SR5-10
EM-SR5-15
9 3/4
7 3/4
4 1/8
POSITION
INDICATOR
3 3/4
SEE NOTE 1
13 13/16
1 5/8
15 3/8
1/2 NPT
CONDUIT
ENTRANCES
8 3/8
SPRING RETURN
PACK
F04 OUTPUT ADAPTER
F04 FEMALE OUTPUT
DRIVE
1 5/8
CLOCKWISE SPRING
RETURN MECHANICAL STOP
.79
COUNTER CLOCKWISE SPRING
RETURN MECHANICAL STOP
MALE OUTPUT DRIVE
2.75 DIA.
3/8-16 X .50 TAP
(4) HOLES
1.170
.630 SQUARE
2.50 DIA.
.585
1.414
.707
.585
.746 DIA.
1.170
FEMALE F04 OUTPUT MOUNTING
.707
5/16-24 X .63 TAP
(4) HOLES
.556 ACROSS CORNERS MIN.
1.414
MALE OUTPUT MOUNTING
.437
SQUARE X .50 DEEP
.433
F04 OUTPUT DRIVE VIEW
NOTE:
1) ADD 4.75 TO OVERALL DIMENSION FOR COVER REMOVAL
Bettis Electric
2500 Park Avenue West, Mansfield, OH 44906 U.S.A.
T419-529-4296
F419-529-4484
Website: www.EmersonProcess.com
E-Mail: [email protected]
© 2002 Emerson. All rights reserved. 5M/01-02
Bulletin #85.15
Assembly Layout Drawings
MODEL EM-SR5-30
9 3/4
7 15/16
4 1/8
POSITION
INDICATOR
3 3/4
SEE NOTE 1
16 1/8
14 3/16
1.63
1/2 NPT
CONDUIT
ENTRANCES
9 1/8
SPRING RETURN
PACK
1 15/16
F05 OUTPUT ADAPTER
F05 FEMALE OUTPUT
DRIVE
CLOCKWISE SPRING
RETURN MECHANICAL STOP
COUNTER CLOCKWISE SPRING
RETURN MECHANICAL STOP
1.02
MALE OUTPUT DRIVE
3.50 DIA.
.748 SQUARE
3.25 DIA.
.958 DIA.
1.392
.696
1.810
1/4-20 X .50 TAP
(4) HOLES
.905
.696
1.392
.905
FEMALE F05 OUTPUT MOUNTING
1.810
MALE OUTPUT MOUNTING
.713 ACROSS CORNERS MIN.
.561
SQUARE .63 DEEP
.556
F05 OUTPUT DRIVE
NOTE:
1) ADD 4.75 TO OVERALL DIMENSION FOR COVER REMOVAL
3/8-24 X .79 TAP
(4) HOLES
TorqPlusTM Electric Actuators
DT BG3
10 3/16
MODEL EM-SR5-90
12 9/16
POSITION INDICATOR
22 1/2
SPRING RETURN
MECHANICAL STOP
1/2-20 TAPPED .87 DEEP
4 HOLES ON 3.06 DIA. B.C.
2 5/32
1 1/4
1 5/64
17
1/2 NPT CONDUIT
ENTRANCES
SQ
1 5/64
.984
2 5/32
NOTE:
1) ADD 4.75 TO OVERALL
FOR COVER REMOVAL
MALE OUTPUT
DRIVE
SPRING RETURN PACK
BEVEL GEAR ACTUATOR
Bettis Electric
2500 Park Avenue West, Mansfield, OH 44906 U.S.A.
T419-529-4296
F419-529-4484
Website: www.EmersonProcess.com
E-Mail: [email protected]
© 2002 Emerson. All rights reserved. 5M/01-02
Bulletin #85.15
Bettis Electric
2500 Park Avenue West
Mansfield, OH 44906 U.S.A.
T 419-529-4296
F 419-529-4484
Website: www.EmersonProcess.com
E-Mail: [email protected]
Bettis USA
P.O. Box 508
Waller, TX 77484 U.S.A.
T 281-463-5100
F 281-463-5103
Website: www.EmersonProcess.com
E-mail: [email protected]
Bettis UK Ltd.
3 Furze Court
114 Wickham Rd.
Fareham, Hampshire PO 16 7SH
T 44-1329-848-900
F 44-1329-848-901
Bettis Canada Ltd.
4112-91 A Street
Edmonton, Alberta T6E 5V2
Canada
T 780-450-3600
F 780-450-1400
Bettis France:
325, Rue de Villeneuve
Silic – BP 40434
94583 RUNGIS, France
T 331-49-797300
F 331-49-797399
Bettis Int’l Sales Office:
Calgary, Canada
Rheinberg, Germany
New Bombay, India
Singapore
Important: Due to Emerson’s continuing commitment to engineered
product advancement, data presented herein is subject to change.
Certified dimensional drawings and wiring diagrams are available on
request. Consult factory with model designation and serial number.
Bettis Bulletin # 10.10 Rev: 02/02
© 2002 Emerson. All rights reserved. 5M/02/02