BETTIS RPE-Series Product Data Sheet June 2014 BR.00.00 Rev.0 Rack and Pinion Pneumatic Actuators (Metric - ISO5211) High quality and economical actuator Improve plant and operator safety Reliable and flexible in process control Increase serviceability Product Data Sheet Bettis RPE-series BEM.06.0000 Rev. 2 November 2015 Table of Contents Section 1: General Information, Torque and Dimensions Data sheet RPE 25 (Metric ISO 5211).............................................................................................. 4 Data sheet RPE 40 (Metric ISO 5211).............................................................................................. 5 Data sheet RPE 65 (Metric ISO 5211).............................................................................................. 6 Data sheet RPE 100 (Metric ISO 5211)............................................................................................ 7 Data sheet RPE 150 (Metric ISO 5211)............................................................................................ 8 Data sheet RPE 200 (Metric ISO 5211)............................................................................................ 9 Data sheet RPE 350 (Metric ISO 5211).......................................................................................... 10 Data sheet RPE 600 (Metric ISO 5211).......................................................................................... 11 3 Bettis RPE-series Product Data Sheet June 2014 BEM.06.0025.EN Rev. 0 Data sheet RPE 25 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) +0.02 øE2 0 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 166 166 B1 B2 43 94 D1 D2 50 M6x10 M6x12 D5 A3 91 B3 80 D3 36 A4 119 C1 16 D4 M5x8 Torque output (Nm) Spring-Return Spring Stroke Torque (Nm) 3.0 barg Start End Start End 10 4 2 12 10 20 7 4 9 6 30 11 7 7 2 40 14 9 50 18 11 60 21 13 Double-Acting 13 Spring set nr. B1 30 A5 82 C2 23 D5 50 RPE 25 A6 49 C3 14 D6 48 A7 30 C4 20 B2 A8 48 C5 12 Principle Pneumatic rack & pinion actuator General data Bore 56 mm Stroke 15.7 mm SR 1.3 kg. Weight DA 1.7 kg. Port A 0.11 L Volume Port B 0.19 L Air connection 2x 1/4" BSP MOP 8 barg Pressure range SR 3-8 barg DA 0.2 - 8 barg Clean, dry or lubricated air or Pressure media inert gas. Open 0.5 sec 2 Cycle speed DA Close 0.4 sec Open 0.5 sec Cycle speed SR2 Close 0.4 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature E1 Max. 11.08 E1 Min. 11.00 E2 14.10 Air Torque (Nm) SUPPLY PRESSURE 3.5 barg Start End 14 13 12 9 9 4 16 4.0 barg Start End 17 15 14 11 11 7 9 3 18 4.5 barg Start End 19 17 16 13 14 9 11 5 9 1 20 5.0 barg Start End 21 20 19 16 16 12 14 8 11 4 23 5.5 barg Start End 24 22 21 18 19 14 16 10 14 6 11 2 25 6.0 barg Start End 26 25 24 21 21 17 18 12 16 8 13 4 27 7.0 barg Start End 31 29 28 25 26 21 23 17 21 13 18 9 32 8.0 barg Start End 36 34 33 30 31 26 28 22 26 18 23 14 36 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications and additional execution please contact your regional sales office 4 Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN Product Data Sheet Bettis RPE-series BEM.06.0040.EN Rev. 0 June 2014 Data sheet RPE 40 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) +0.02 øE2 0 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 192 192 B1 B2 45 94 D1 D2 70 M8x13 M6x12 D5 A3 112 B3 B1 30 A4 139 C1 A5 95 C2 RPE 40 A6 A7 55 34 C3 C4 A8 58 C5 E1 Max. 14.08 E1 Min. 12 14.00 80 22 30 14 D3 D4 M6x10 D5 68 D6 E2 65 18.10 50 Spring set nr. Torque output (Nm) Spring-Return Spring Stroke Torque (Nm) 3.0 barg Start End Start End 10 7 4 22 19 20 13 8 17 12 30 20 12 12 4 40 26 17 50 33 21 60 39 25 Double-Acting 25 20 B2 Principle Pneumatic rack & pinion actuator General data Bore 70 mm Stroke 18.8 mm SR 2.4 kg. Weight DA 1.8 kg. Port A 0.16 L Volume Port B 0.36 L Air connection 2x 1/4" BSP MOP 8 bar Pressure range SR 3-8 bar DA 0.2 - 8 bar Clean, dry or lubricated air or Pressure media inert gas. Open 0.6 sec 2 Cycle speed DA Close 0.5 sec Open 0.6 sec 2 Cycle speed SR Close 0.5 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature Air Torque (Nm) SUPPLY PRESSURE 3.5 barg Start End 26 24 22 16 17 9 12 1 29 4.0 barg Start End 31 28 26 21 21 13 17 6 34 4.5 barg Start End 36 33 31 25 26 18 21 10 17 3 38 5.0 barg Start End 40 37 35 30 31 22 26 15 21 7 42 5.5 barg Start End 45 42 40 34 35 27 30 19 26 12 21 4 47 6.0 barg Start End 49 46 44 39 40 31 35 24 30 16 25 9 51 7.0 barg Start End 58 55 53 48 49 40 44 33 39 25 34 18 59 8.0 barg Start End 67 64 62 57 58 49 53 42 48 34 43 27 68 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN and additional execution please contact your regional sales office 5 Bettis RPE-series Product Data Sheet June 2014 BEM.06.0065.EN Rev. 0 Data sheet RPE 65 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) 0 øE2+0.02 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 217 217 B1 B2 50 94 D1 D2 70 M8x13 M6x12 D5 A3 124 B3 B1 30 A4 151 C1 B2 RPE 65 A5 A6 A7 104 58 38 C2 C3 C4 A8 69 C5 E1 Max. 14.08 E1 Min. 12 14.00 80 22 30 14 D3 D4 M6x10 D5 68 D6 E2 65 18.10 50 Spring set nr. Torque output (Nm) Spring-Return Spring Stroke Torque (Nm) 3.0 barg Start End Start End 10 10 6 33 29 20 20 13 26 17 30 31 19 19 5 40 41 26 50 51 32 60 61 39 Double-Acting 38 20 Principle Pneumatic rack & pinion actuator General data Bore 80 mm Stroke 22 mm SR 3.6 kg. Weight DA 2.4 kg. Port A 0.36 L Volume Port B 0.55 L Air connection 2x 1/4" BSP MOP 8 bar Pressure range SR 3-8 bar DA 0.2 - 8 bar Clean, dry or lubricated air or Pressure media inert gas. Open 0.7 sec Cycle speed DA2 Close 0.5 sec Open 0.6 sec 2 Cycle speed SR Close 0.6 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature Air Torque (Nm) SUPPLY PRESSURE 3.5 barg Start End 40 36 33 24 25 12 45 4.0 barg Start End 47 43 40 31 32 19 25 8 51 4.5 barg Start End 54 50 47 38 39 26 32 14 24 3 58 5.0 barg Start End 61 57 53 45 46 33 39 21 31 10 64 5.5 barg Start End 68 63 60 52 53 40 46 28 38 17 31 5 71 6.0 barg Start End 75 70 67 59 60 47 52 35 45 23 38 12 77 7.0 barg Start End 88 84 81 72 74 61 66 49 59 37 52 25 90 8.0 barg Start End 102 98 95 86 87 74 80 63 73 51 65 39 104 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications and additional execution please contact your regional sales office 6 Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN Product Data Sheet Bettis RPE-series BEM.06.0100.EN Rev. 0 June 2014 Data sheet RPE 100 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) 0 øE2+0.02 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 247 247 B1 B2 60 97 D1 D2 70 M8x13 M6x12 D5 A3 131 B3 B1 30 A4 158 C1 A5 115 C2 RPE 100 A6 A7 64 38 C3 C4 A8 69 C5 E1 Max. 19.08 E1 Min. 12 19.00 80 22 35 14 D3 D4 M6x10 D5 66 D6 E2 63 25.20 50 Spring set nr. Torque output (Nm) Spring-Return Spring Stroke Torque (Nm) 3.0 barg Start End Start End 10 15 9 49 43 20 30 19 39 26 30 44 28 28 9 40 59 37 50 74 47 60 89 56 Double-Acting 57 20 B2 Principle Pneumatic rack & pinion actuator General data Bore 91 mm Stroke 25.1 mm SR 4.6 kg. Weight DA 3.1 kg. Port A 0.36 L Volume Port B 0.82 L Air connection 2x 1/4" BSP MOP 8 bar Pressure range SR 3-8 bar DA 0.2 - 8 bar Clean, dry or lubricated air or Pressure media inert gas. Open 0.8 sec 2 Cycle speed DA Close 0.6 sec Open 0.8 sec Cycle speed SR2 Close 0.7 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature Air Torque (Nm) SUPPLY PRESSURE 3.5 barg Start End 60 53 49 36 38 19 27 2 66 4.0 barg Start End 70 64 59 47 48 30 38 13 76 4.5 barg Start End 80 74 69 57 59 40 48 23 37 6 86 5.0 barg Start End 90 84 79 67 69 50 58 33 47 16 95 5.5 barg Start End 100 94 90 77 79 60 68 43 57 26 47 9 105 6.0 barg Start End 111 104 100 87 89 70 78 53 68 36 57 19 115 7.0 barg Start End 131 125 120 108 109 91 99 74 88 57 77 40 134 8.0 barg Start End 151 145 141 128 130 111 119 94 108 77 98 60 153 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN and additional execution please contact your regional sales office 7 Bettis RPE-series Product Data Sheet June 2014 BEM.06.0150.EN Rev. 0 Data sheet RPE 150 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) 0 øE2+0.02 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 304 235 B1 B2 75 94 D1 D2 102 M10x15 M6x12 D5 A3 157 B3 B1 30 A4 185 C1 A5 127 C2 RPE 150 A6 A7 69 49 C3 C4 A8 75 C5 E1 Max. 19.08 E1 Min. 12 19.00 80 34 45 19 D3 D4 M8x13 D5 97 D6 E2 92 25.50 70 Spring set nr. Torque output (Nm) Spring-Return Spring Stroke Torque (Nm) 3.0 barg Start End Start End 10 24 15 79 69 20 47 30 62 42 30 71 44 45 15 40 94 59 50 118 74 60 141 89 Double-Acting 91 20 B2 Principle Pneumatic rack & pinion actuator General data Bore 103 mm Stroke 31.4 mm SR 6.9 kg. Weight DA 4.8 kg. Port A 0.78 L Volume Port B 0.71 L Air connection 2x 1/4" BSP MOP 8 bar Pressure range SR 3-8 bar DA 0.2 - 8 bar Clean, dry or lubricated air or Pressure media inert gas. Open 1.0 sec 2 Cycle speed DA Close 0.8 sec Open 0.9 sec Cycle speed SR2 Close 0.8 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature Air Torque (Nm) SUPPLY PRESSURE 3.5 barg Start End 96 86 79 59 62 32 45 5 106 4.0 barg Start End 112 102 95 75 78 48 61 21 122 4.5 barg Start End 128 118 111 91 94 64 77 37 60 10 137 5.0 barg Start End 145 135 128 108 111 81 94 54 77 26 153 5.5 barg Start End 161 151 144 124 127 97 110 70 93 43 76 16 168 6.0 barg Start End 177 167 160 140 143 113 126 86 109 59 92 32 183 7.0 barg Start End 210 200 193 173 176 146 159 119 142 92 125 65 214 8.0 barg Start End 243 233 226 206 209 179 192 152 175 124 158 97 245 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications and additional execution please contact your regional sales office 8 Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN Product Data Sheet Bettis RPE-series BEM.06.0200.EN Rev. 0 June 2014 Data sheet RPE 200 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) 0 øE2+0.02 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 362 265 B1 B2 75 94 D1 D2 102 M10x15 M6x12 D5 A3 163 B3 B1 30 A4 191 C1 A5 134 C2 RPE 200 A6 A7 72 49 C3 C4 A8 87 C5 E1 Max. 22.10 E1 Min. 12 22.00 80 36 45 19 D3 D4 M8x13 D5 94 D6 E2 90 28.20 70 Spring set nr. Torque output (Nm) Spring-Return Spring Stroke Torque (Nm) 3.0 barg Start End Start End 10 33 21 108 94 20 65 41 85 57 30 98 62 61 19 40 131 82 50 163 103 60 196 124 Double-Acting 124 20 B2 Principle Pneumatic rack & pinion actuator General data Bore 110 mm Stroke 37.7 mm SR 9.7 kg. Weight DA 5.8 kg. Port A 0.82 L Volume Port B 0.97 L Air connection 2x 1/4" BSP MOP 8 bar Pressure range SR 3-8 bar DA 0.2 - 8 bar Clean, dry or lubricated air or Pressure media inert gas. Open 1.3 sec 2 Cycle speed DA Close 0.9 sec Open 1.0 sec Cycle speed SR2 Close 1.0 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature Air Torque (Nm) SUPPLY PRESSURE 3.5 barg Start End 131 117 107 79 83 42 146 4.0 barg Start End 153 139 129 102 106 64 82 26 167 4.5 barg Start End 175 161 152 124 128 86 104 49 81 11 188 5.0 barg Start End 198 184 174 146 150 109 127 71 103 34 209 5.5 barg Start End 220 206 196 169 173 131 149 93 125 56 102 18 230 6.0 barg Start End 242 228 219 191 195 153 171 116 148 78 124 41 251 7.0 barg Start End 287 273 263 236 240 198 216 161 192 123 169 85 293 8.0 barg Start End 332 318 308 280 284 243 261 205 237 168 213 130 335 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN and additional execution please contact your regional sales office 9 Bettis RPE-series Product Data Sheet June 2014 BEM.06.0350.EN Rev. 0 Data sheet RPE 350 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) 0 øE2+0.02 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 385 284 B1 B2 85 100 D1 D2 102 M10x15 M6x12 D5 A3 201 B3 B1 30 A4 230 C1 A5 165 C2 RPE 350 A6 A7 85 42 C3 C4 A8 109 C5 E1 Max. 27.11 E1 Min. 12 27.00 80 36 45 19 D3 D4 M8x13 D5 94 D6 E2 94 36.20 70 Spring set nr. Torque output (Nm) Spring-Return Spring Stroke Torque (Nm) 3.0 barg Start End Start End 10 56 35 189 165 20 112 70 148 101 30 168 106 108 36 40 224 141 50 280 176 60 335 211 Double-Acting 216 20 B2 Principle Pneumatic rack & pinion actuator General data Bore 145 mm Stroke 37.7 mm SR 16.9 kg. Weight DA 10.4 kg. Port A 1.94 L Volume Port B 1.68 L Air connection 2x 1/4" BSP MOP 8 bar Pressure range SR 3-8 bar DA 0.2 - 8 bar Clean, dry or lubricated air or Pressure media inert gas. Open 1.9 sec 2 Cycle speed DA Close 1.3 sec Open 1.4 sec Cycle speed SR2 Close 1.5 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature Air Torque (Nm) SUPPLY PRESSURE 3.5 barg Start End 227 204 187 139 146 75 106 11 253 4.0 barg Start End 266 243 226 178 185 114 145 50 290 4.5 barg Start End 305 281 265 217 224 153 184 89 143 24 326 5.0 barg Start End 344 320 303 256 263 192 222 127 182 63 363 5.5 barg Start End 383 359 342 295 302 231 261 166 221 102 180 38 400 6.0 barg Start End 422 398 381 334 341 269 300 205 260 141 219 77 436 7.0 barg Start End 499 476 459 411 418 347 378 283 337 218 297 154 510 8.0 barg Start End 577 553 537 489 496 425 455 360 415 296 374 232 583 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications and additional execution please contact your regional sales office 10 Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN Product Data Sheet Bettis RPE-series BEM.06.0600.EN Rev. 0 June 2014 Data sheet RPE 600 Metric - ISO5211 4 2x 1/4” BSP A8 C5 4 C4 A4 A3 A7 A2 (DA) A1 (SR) 0 øE2+0.02 A5 A6 4x M5x8 øD1 øD3 B3 C2 C1 C3 4x M5x8 D6 E1 4x D4 4x D2 Dim in mm. A1 A2 476 356 B1 B2 98 148 D1 D2 125 M12x18 M6x12 D5 A3 248 B3 130 D3 102 B1 30 B2 A4 292 C1 RPE 600 A5 A6 A7 199 102 67 C2 C3 C4 A8 132 C5 E1 Max. 27.11 E1 Min. 55 65 -/- -/- 27.00 D4 D5 M10x16 118 D6 E2 94 36.20 30 Principle Pneumatic rack & pinion actuator General data Bore 175 mm Stroke 44 mm SR 27.6 kg. Weight DA 19.4 kg. Port A 3.10 L Volume Port B 2.86 L Air connection 2x 1/4" BSP MOP 8 bar Pressure range SR 3-8 bar DA 0.2 - 8 bar Clean, dry or lubricated air or Pressure media inert gas. Open 3.2 sec Cycle speed DA2 Close 1.9 sec Open 2.2 sec 2 Cycle speed SR Close 2.2 sec Temperature range -20°C to +80°C Lubrication Lubricated for life1 Rotation 90° Over / Undertravel +5° / -5° at each end Finish Polyurethane powder coat 1. According to EN 15714-3 2. Test conditions: Solenoid with flow capacity: 0.6 m3/hr Pipe diameter: 6 mm Medium: clean air Supply pressure: 5.5 barg ≈ 80 psig Load: with average load Stroke: 90° Temperature: Room temperature Spring set nr. Torque output (Nm) Spring-Return Spring Air Torque (Nm) Stroke SUPPLY PRESSURE Torque (Nm) 3.0 barg 3.5 barg 4.0 barg 4.5 barg 5.0 barg 5.5 barg 6.0 barg 7.0 barg 8.0 barg Start End Start End Start End Start End Start End Start End Start End Start End Start End Start End 10 96 60 320 279 386 345 452 411 518 477 584 543 650 609 716 675 848 807 980 939 20 192 121 251 169 317 235 383 301 449 367 515 433 581 499 647 565 779 697 911 829 30 287 181 181 59 247 125 313 191 379 257 445 323 511 389 577 455 709 587 841 719 40 383 241 178 15 244 81 310 147 376 213 442 279 508 345 640 477 772 609 50 479 302 241 37 307 103 373 169 439 235 571 367 703 499 60 575 362 303 59 369 125 501 257 633 389 Double-Acting 368 430 492 554 617 679 741 866 991 Notes: European Directives: Volume is the actual free air volume at 1 atm PED : suitable for use with group 2 gases according to Pressure Flange and square drive to ISO 5211 Solenoid mounting interface according to VDI/VDE 3845 (according to NAMUR) For further information regarding options, materials, certifications Equipment Directive 97/23/EC ATEX : suitable for use in hazardous areas classified II 2 GD, zones 1 or 2 (gases) and 21 or 22 (dust) For the configuration code please consult BEG.02.01.EN and additional execution please contact your regional sales office 11 World Area Configuration Centers (WACC) offer sales support, service, inventory and commissioning to our global customers. Choose the WACC or sales office nearest you: NORTH & SOUTH AMERICA MIDDLE EAST & AFRICA 19200 Northwest Freeway Houston, TX 77065 T +1 281 477 4100 F +1 281 477 2809 P. O. Box 17033 Dubai United Arab Emirates T +971 4 811 8100 F +971 4 886 5465 Av. Hollingsworth, 325, Iporanga Sorocaba, SP 18087-105 Brazil T +55 15 3238 3788 F +55 15 3228 3300 ASIA PACIFIC No. 9 Gul Road #01-02 Singapore 629361 T +65 6501 4600 F +65 6268 0028 No.1 Lai Yuan Road Wuqing Development Area Tianjin 301700 P.R.China T +86 22 8212 3300 F +86 22 8212 3308 P. O. Box 10305 Jubail 31961 Saudi Arabia T +966 3 340 8650 F +966 3 340 8790 24 Angus Crescent Longmeadow Business Estate East P.O. Box 6908; Greenstone; 1616 Modderfontein, Extension 5 South Africa T +27 11 451 3700 F +27 11 451 3800 EUROPE Berenyi u. 72- 100 Videoton Industry Park Building #230 Székesfehérvár 8000 Hungary T +36 22 53 09 50 F +36 22 54 37 00 For complete list of sales and manufacturing sites, please visit www.emerson.com/actuationtechnologieslocations Or contact us at [email protected] www.emerson.com/bettis All Rights Reserved. We reserve the right to modify or improve the designs or specifications of the products mentioned in this manual at any time without notice. Emerson does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson product remains solely with the purchaser. ©2015 Emerson Electric Co.
© Copyright 2024 Paperzz