Data sheet Sheet No.: PHSP3.01 RevA Date: October 2010 PHS P3 PHS-P3, Accessories for Valve/Actuator Area Application: Description: PHS Pipe Block: For emergency operation of 1-line actuators (spring return) by means of portable hand pump. The block is pipe mounted. PHS Pipe Block: Block with single quick connection and stop valve. The block has connection tread G 3/8. PHS Pipe Block: Block with single quick connection and stop valve. The block has connection tread G1/4. P3: Cross-over plate: Plate for cross - connecting ports P and A, respectively B and T of a Cetop-3/NG 6 stack. P3: Cross-over plate: Whenever a Cetop -3/NG 6 mounting block is used for mounting of control equipment on the actuator, a P3 plate is necessary to close the Cetop-3 “sandwich”. PHS – bleeder fail close: Bleed pipe from actuator can be connected to block. PHS – bleeder fail open, submerged: Bleed pipe from actuator can be connected to block. DPHS – pipe block, submerged: For emergency operation of 2-line actuator by means of portable hand pump. The block is pipe mounted. Main data: PHS – bleeder fail close: For emergency operation of 1-line submerged actuator (fail close) by means of portable hand pump. The block is pipe mounted. PHS – bleeder fail open: For emergency operation of 1-line submerged actuator (fail open) by means of portable hand pump. The block is pipe mounted. PHS P3 PHS-bleed fail close Max. operation pressure: 135 bar/2000 PSI Max test pressure: 225 bar/3250 PSI DPHS Flow rate at 100 bar, (50 cSt visc.) l/min. 6 20 6 6 6 Weight approx.: kg/lb 0.6/1.3 0.2/0.4 1.1/2.4 1.1/2.4 1.1/2.4 Materials: Brass Application examples: Remote breathing from actuator spring cavity. Emergency operation by means of portable hand pump. DPHS – pipe block: For emergency operation of 2-line actuator or system consisting LPU, both S and D, by means of portable hand pump. www.Bettis.com PHS-bleed fail open Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600 Data sheet Sheet No.: PHSP3.02 RevA Date: October 2010 PHS P3 Hydraulic diagram: PHS Block PHS block with bleeder for fail close PHS block with bleeder for fail open www.Bettis.com Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600 Data sheet Sheet No.: PHSP3.03 RevA Date: October 2010 PHS P3 Main dimensions: PHS Pipe Block G3/8” (2.91) 43 (1.69) 6 (.24) PHS Pibe Block G1/4” 14.5 (.57) 49 (1.93) 30 (1.18) (7.87) (.22) (.22) (.52) (1.42) (2.19) 18 (.52) 12 (.47) (2.40) 11 (.43) (.78) 69 (2.72) (1.57) 33 (1.30) (1.57) (1.36) 5 (.20) 20 (.79) 13 (.51) 24 (.94) 38 (1.50) 38 (1.50) 11 (.43) 60 (2.36) www.Bettis.com 40 (1.57) 71.5 (2.81) 14 (.55) 7.5 (.30) 30 (1.18) 60 (2.36) 26 (.98) 41.5 (1.63) DPHS Block 11 (.43) 38 (1.50) 49 (1.93) 16 (.63) 40 (1.57) Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600 Data sheet Sheet No.: PHSP3.04 RevA Date: October 2010 PHS P3 Main dimensions (continued): PHS Bleeder Fail Open P3 41.5 (1.63) 7.5 (.30) (2.36) 60 (2.36) (.39) (.28) 26 (.98) 14 (.55) 40 (1.57) 71.5 (2.81) (1.77) 30 (1.18) 27 (1.06) 16 (.63) 40 (1.57) 40 (1.57) 14 (.55) 71.5 (2.81) 30 (1.18) 14 (.55) 7.5 (.30) M8 x 12/16 26 (.98) 41.5 (1.63) PHS Bleeder Fail Closed 60 (2.36) 11 (.43) 38 (1.50) 11 38 (1.50)(.43) 49 (1.93) 16 (.63) 40 (1.57) Note: Not Certified dimensional drawings. Such drawings are available on request. Contact factory with correct model designation and serial number. Important: Due to Emerson’s continuing commitment to engineered product advancement, data presented herin is subject to change. The contents of the publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expresses or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. www.Bettis.com Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.bettis.com or from your nearest Valve Automation Center. USA: +1 281 727 5300 Europe: +31 74 256 1010 Asia-Pacific: +65 6501 4600 (1.28) (.28) (1.59) (1.22) 38 (1.50) 11 (.43) 49 (1.93)
© Copyright 2026 Paperzz