/illegible/ TC 1634 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Research Center TEST LABORATORY of CJSC SRC TECHNOPROGRESS Accreditation certificate No. РОСС RU.0001.21MЭ67 Approved by: Deputy Head of the Test Laboratory of CJSC SRC TECHNOPROGRESS ______________ / L.V. Polubotko on June 1, 2015 SEAL HERE Seal: CJSC Scientific and Research Center TECHNOPROGRESS, MOSCOW city Test Laboratory No. РОСС RU.0001.21MЭ67 FOR TEST REPORTS REPORT No. 2869Ех of Technical Documents Examination, Design Check and Certification Tests Name Explosion-proof electric actuator ТЕС 2000, model 2GRG-5, serial of product: No. 127109F02, Ex-marking 1Ex d IIB Т4 Applicant: Scientific and Technical Center Techno-Standart Ltd. Applicant’s address: 24 Ryazansky avenue, block 2, 109428, Moscow Manufacturer: Strongarm LLC Manufacturer’s 18A Melnichnaya str., 192019, Saint Petersburg address: Moscow 2015 The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 2 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS 1. Product: Russian classification OKP code: HS Code: 2. Manufacturer: Manufacturer’s address: 3. Applicant: Applicant’s address: 4. Tests basis: 5. 6. 7. 8. 9. 10. 11. 12. Explosion-proof electric actuator ТЕС 2000, model 2GRG-5, serial No. 127109F02, Ex-marking 1Ех d IIВ Т4 37 9110 8501 52 200 9 Strongarm LLC 18A Melnichnaya str., 192019, Saint Petersburg Scientific and Technical Center Techno-Standart Ltd. 24 Ryazansky avenue, block 2, 109428, Moscow Tests application No. 23 dated 05/17/2015 GOST 30852.0-2002, GOST 30852.1-2002 Requirements: GOST 30852.0-2002, GOST 30852.1-2002 Tests methods: The tests were aimed at checking the product compliance with the General provisions: requirements of GOST 30852.0-2002, GOST 30852,1-2002 Product tested: Explosion-proof electric actuator ТЕС 2000, model Tests object: 2GRG-5, serial No. 127109F02, Ex-marking 1 Ex d IIВ Т4 Tests started on: 05/17/2015 Tests date, extent and Tests ended on: 06/01/2015 location: The tests were performed at the Test Laboratory of CJSC Scientific and Research Center TECHNOPROGRESS to the full extent. Environmental specifications: Tests conditions: - air temperature: (21 ±2)°С above zero; - relative humidity: (65±10)%; - atmospheric pressure: (99.3±0.6) kPa. The measuring tools are listed in Annex F. Measuring tools: The measuring tools used in the tests were provided with valid certificates (stamps) of compliance with the Measuring tools calibration procedure PR 50.2.006. This Report should be used together with GOST 30852.0-2002, GOST 30852.1-2002. Test Laboratory of CJSC SRC TECHNOPROGRESS 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 3 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS 13. Basic technical data 13.1 The electric actuator basic technical data are shown in Table 1. Table 1 Parameter Ex-marking Value 1Ex d IIB Т4 Exposure protection degree per GOST 14254-96 IР68 Twitching-off torque, N*m 343 Max. torque (jamming), N*m 510 Output shaft rotation speed, rpm 43 Operating temperature range, °C from -60 to +70 Shaft rotation direction Clockwise (top view) closing Valve connection type F14 Dimensions, mm 815x470 x256 Actuator weight, kg 73 14. Documents submitted for consideration 14.1 Supporting documents are listed in Table 2. Table 2 Document title Document designation Data sheet Explosion-proof electric actuator TEC 2000 for industrial pipeline valve Serial number 127109F02 Installation, setup, operation and maintenance Explosion-proof electric actuator TEC 2000 for industrial pipeline manual valve Specifications TU 379110-031-37719281-2015 Technical description Electric actuator TEC 2000 for industrial pipeline valve Assembly drawing Explosion protection drawing Number 84720 Number 84500 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 4 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS 16. Test object identification Motor appearance, design and marking (see Annex E) complies with the documents and drawings submitted. (Fig. 1) Fig. 1 Explosion-proof electric actuator TEC 2000, model 2GRG-5, serial No. 127I09F02, Ex-marking 1Ex d IIB Т4 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 5 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Table 4. GOST 30852.0-2002 compliance checks and tests list Excerpts from GOST 30852.0-2002 (IEC 60079-1:1998) containing standardized technical requirements and tests Sections and items No. Evaluation and tests results Requirements compliance statement Maximum surface temperature Item 5.1 Maximum surface temperature does not exceed the declared temperature class T4. See Annex A Compliant Ambient temperature Item 5.2 Ambient temperature operating range -60°C ... +70°C Compliant Surface and ignition temperature Temperatures Item 5.3 The requirement is not applicable Not applicable Requirements to all types of electrical equipment Item 6 Explosion protection type “d” — explosion-proof shell Compliant Non-metallic shells and their parts Item 7 Light-transmitting part is made of glass. The requirement is not applicable. Not applicable Shells made of light metals-containing materials Item 8 Shell materials: steel 45, aluminum, ductile iron. Magnesium weight content is at most 7.5%. The requirement is met Compliant Fasteners Item 9 The requirement is met Compliant Lockings Item 10 The requirement is met Compliant Bushings Item 11 No bushings. The requirement is not applicable Not applicable Sealant materials Item 12 The requirement is met Not applicable Ex-components Item 13 Ex-components are not used Not applicable Entries and connecting terminals Item 14 Certified cable entries must be used Compliant Connection terminals for grounding and neutral protective conductors Item 15 8 mm screws on the motor and actuator main gear housing are used for external grounding. Compliant Cable and pipe entries Item 16 Certified cable entries must be used Compliant Additional requirements to rotating electrical machines Item 17 The requirement is not applicable. Cooling fans are not used Not applicable Additional requirements to switching devices Item 18 The requirement is not applicable Not applicable Additional requirements to safety fuses Item 19 Safety fuses are not used Not applicable Additional requirements to connectors, thrust accumulators and thrust batteries Item 20 Connectors, thrust accumulators and rechargeable batteries are not used Not applicable Lighting devices Item 21 Lighting devices are not used Not applicable Additional requirements to head and hand-held lamps Item 22 The requirement is not applicable Not applicable Checks and tests 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 6 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Excerpts from GOST 30852.0-2002 (IEC 60079-1:1998) containing standardized technical requirements and tests Sections and items No. Evaluation and tests results Requirements compliance statement General provisions 23.1 The requirement is met Compliant Documents check 23.2 The documents contain a fairly complete and accurate description of all electrical equipment explosion protection aspects Compliant Prototype or specimen compliance with documents 23.3 The specimens comply with the submitted documents Compliant 23.4.1 The models were tested in accordance with the requirements of GOST 30852.0-2002 Compliant Impact resistance test 23.4.3.1 The requirement is met. See Annex B Compliant Drop test 23.4.3.2 The electrical equipment is not hand-held. The requirement is not applicable Not applicable Necessary results 23.4.3.3 No damages to the electrical equipment explosion protection were revealed Compliant Material friction intrinsic safety check 23.4.3.4 The requirement is met Compliant Electrolyte spillage test of rechargeable batteries 23.4.3.5 Rechargeable batteries are not used Not applicable Checking the degree of protection provided by the shells 23.4.4 The requirement is met. See Annex C Compliant Bushings torque test 23.4.5 The requirement is not applicable Not applicable Thermal tests 23.4.6 The requirement is met. See Annex A Compliant Non-metallic shells or shell parts test 23.4.7 The requirement is met Compliant Test in explosive mixtures 23.4.8 Test per GOST 30852.1-2002. See Annex E Compliant Control checks and tests by the manufacturer Item 24 The manufacturer performs hydraulic overpressure test at 1.0 MPa for 10 seconds Compliant Manufacturer’s responsibility Item 25 Ensured by the manufacturer Compliant Checks and tests of repaired and upgraded electrical equipment Item 26 The requirement is not applicable Not applicable Marking Item 27 The requirement is met. Marking plate layout is shown in Annex E Compliant Tests General provisions Mechanical tests 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Test Report No. 2869Ех Page 7 of 18 The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Table 5. GOST 30852.1-2002 compliance checks and tests list Excerpts from GOST 30852.1-2002 (IEC 60079-1:1998) containing standardized technical requirements and tests Sections and items No. Evaluation and tests results Requirements compliance statement General requirements Item 5.1 The requirement is met. See Annex E Compliant Non-threaded joints Item 5.2 The requirement is met. See Annex E Compliant Threaded joints Item 5.3 The requirement is met. See Annex E Compliant Gaskets and O-rings Item 5.4 The requirement is met Compliant Sealed joints Item 5.5 The requirement is met. See Annex E Compliant Control thrust rods and shafts Item 6 The requirement is met. See Annex E Compliant Shafts and bearing shields of rotating electrical machines Item 7 Rolling bearings are used. The length of explosion-proof joint gap with the bearing shield is at least equal to the shaft diameter. Compliant Light-transmitting parts Item 8 Light-transmitting part is made of glass. Compliant Ventilation, discharging and draining devices Item 9 Ventilation, discharging and draining devices are not used. Not applicable Fasteners Item 10 Thickness of the metal surrounding the hole for fixing bolts exceeds 3 mm. The requirement is met Compliant Shell mechanical strength Item 11 Test per item 15 of GOST 30852.12002. See Annex B Compliant Wires and cables entry into the shell Item 12 Certified cable entries must be used Compliant Marking Item 13 The requirement is met. Marking plate layout is shown in Annex E Compliant Item 14 The requirement is met Compliant Item 15.1 The requirement is met Compliant Checking explosion protection parameters with the help of standard measuring tools Item 15.2 The requirement is met Compliant Determination of explosion pressure Item 15.3 The requirement is met. See Annex D Compliant Explosion resistance test Item 15.4 The requirement is met. See Annex D Compliant Shell explosion-proof test with spark discharge Item 15.5 The requirement is met. See Annex D Compliant Metal grids and flame arresters-made shells test Item 15.6 Metal grids and flame arresters are not used Not applicable Cable entries pressure leak and mechanical strength test Item 15.7 Certified cable entries must be used Not applicable Explosion-proof joints Tests methods General provisions Shell check and test Shell compliance with this standard 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 8 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Excerpts from GOST 30852.1-2002 (IEC 60079-1:1998) containing standardized technical requirements and tests Sections and items No. Evaluation and tests results Requirements compliance statement Shells test by the electrical equipment manufacturer Item 16 The manufacturer performs hydraulic overpressure test at 1.0 MPa for 10 seconds Compliant Non-metallic explosion-proof shell and their parts Annex A The requirement is not applicable. Light-transmitting part area is less than 100 cm2. Not applicable Testing metal grids-made shells of gas control sensors Annex D The requirement is not applicable Not applicable Tested by: Test engineer / D.V. Kharitonov 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Test Report No. 2869Ех Page 9 of 18 The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Annex A to the Report No. 2869Ех Thermal tests per GOST 30852.0-2002 The tests were performed according to the method provided in item 23.4.6.1 of GOST 30852.0-2002. The tests were performed under the harshest possible conditions with the most adverse deviation in supply voltage ranging from 90% to 110% of the electrical equipment rated voltage. The external surface temperature does not exceed 120°C. The test results meet the requirements of GOST 30852.0-2002 for the electrical equipment of Group II, temperature class T4 taking into account correction and maximum ambient temperature during the product operation. Tested by: Test engineer / D.V. Kharitonov Test Laboratory of CJSC SRC TECHNOPROGRESS 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Accreditation certificate РОСС RU.0001.21MЭ67 Research Center Page 10 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Annex B to the Report No. 2869Ех Impact resistance test The tests were performed using a striking pin per item 23.4.3.1 of GOST 30852.0-2002. Impact energy was chosen as shown in Table 4 of GOST 30852.0-2002. Since the electric actuator is made of steel, it was decided to test 1 specimen. The tests results are shown in Table B.1. Table B.1 Impact place Specimen temperature, °C Electrical compartment housing (top) (20±5) 7 0.7 No damages affecting the protection type are observed at the impact place. Electrical compartment housing (side) (20±5) 7 0.7 No damages affecting the protection type are observed at the impact place. Electrical compartment housing (rear) (20±5) 7 0.7 No damages affecting the protection type are observed at the impact place. Light-transmitting part (20±5) 4 0.4 No damages affecting the protection type are observed at the impact place. Motor compartment housing (20±5) 7 0.7 No damages affecting the protection type are observed at the impact place. Motor compartment cover (20±5) 7 0.7 No damages affecting the protection type are observed at the impact place. Tested by: Test engineer Impact energy, Load drop height, m J Result / D.V. Kharitonov 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Accreditation certificate РОСС RU.0001.21MЭ67 Research Center Page 11 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Annex C to the Report No. 28б9Ех The results of the shell protection degree compliance tests (IP code) per GOST 14254-96 Shell dust protection test Table C.1 Verified characteristic digit The first 6 Dust consumption in the test chamber, kg/m3 Test equipment Vacuuming dust chamber 2.0 Test conditions, item number 13.4, 13.6 Test results Upon completion of the test no talc powderlike dust deposit was observed inside the housing Shell hard object protection test Table C.2 Verified characteristic digit Test equipment Test force Test conditions, item number Test results The first 6 Test wire of 1.0 mm in diameter and 100 mm long 1 N ± 10% 12.2 Accessibility probe does not touch hazardous mechanical parts Shell water protection test Table С.3 Verified characteristic digit Test equipment Test duration Test conditions, item number Test results The second 8 The tests were performed in the pressure chamber at 10.8 kPa, which corresponds to dive to a depth of 1.1 m 35 min 14.2.8 Upon completion of the test no moisture was observed inside the housing Tested by: Test engineer / D.V. Kharitonov Test Laboratory of CJSC SRC TECHNOPROGRESS 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Accreditation certificate РОСС RU.0001.21MЭ67 Research Center Page 12 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Annex D to the Report No. 2869Ex Explosion safety tests Determination of explosion pressure The tests per GOST 30852.1-2002, item 15.3, involve igniting explosive mixture inside the shell with a spark discharge at atmospheric pressure and ambient temperature, as well as measuring the pressure of the explosion with the explosion-proof gaps width not exceeding the tolerances specified in the technical documents. Electric actuator installation in the explosion chamber is shown in fig. D.1. The test results are shown in Table D.1 Table D.1 Shell, compartment name Explosion pressure kPa; Ethylene (8 ± 0.5)% Experiment 1 Experiment 2 Experiment 3 Motor compartment 432 433 427 Electrical compartment 662 651 624 Explosion resistance test The explosion resistance test was performed using dynamic method per item 15.4 of GOST 30852.1-2002. 1.5times explosion pressure specified in item 15.3.6 was taken as the test pressure. See the test results in Table D.2. Table D.2 Shell, compartment name Motor compartment Electrical compartment Test pressure kPa Test results 649.5 No shell destruction or deformation 993 No shell destruction or deformation Explosion-proof tests The explosion-proof tests per GOST 30852.1-2002, item 15.5.1, subgroup IIB, hydrogen content of (37±1.0)%, were performed under normal pressure (not increased intentionally). A high-voltage spark plug was used to ignite the explosive mixture inside the shell. The tests were performed with the gap width in all explosion-proof joints conditioned by normal assembly in accordance with item 15.5.1.1, GOST 30852.1-2002. The tests results are shown in the Table D.3. Table D.3 Shell, compartment name Number of explosions Explosion transfer Motor compartment 5 No Electrical compartment 5 No 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 13 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Fig. D.1 Installation of the electric actuator TEC 2000 in the explosion chamber: 1. Spark plug 2. Inlet connecting branch 3. Pressure sensors 4. Outlet connecting branch Tested by: Test engineer / D.V. Kharitonov 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 14 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Annex E to the Report No. 2869Ех Description of the product design and explosion protection means The electric actuator TEC2000 is intended to remotely and locally operate shutoff and control pipeline multi-turn, part-turn and straight-type valves when they are used with auxiliary mechanisms. The electric actuator includes the following structural elements: • electric motor; • main reduction gear consisting of a motor reduction gear and non-reversible worm gear; • handwheel; • actuator limiting device in the shut-off valve extreme positions (with switching elements); • control box. Electric actuator explosion protection is ensured with: Enclosing electrical components in the explosion-proof shell capable of withstanding the pressure of an explosion inside it and preventing the explosion from entering into the surrounding explosive environment; The word “Explosion” on the explosion protection means drawing denotes all explosion-proof joints and places where explosion-proof seals are adjacent to the shell parts. Explosion-proof joints parameters as well as other data and dimensions that ensure shell explosion-proof capability and its explosion resistance are provided and must be observed in the electric actuator operation and maintenance. Electrostatic spark-proof capability is ensured by absence of plastic external parts on the shell. Explosion-proof surfaces are protected from corrosion due to corrosion preventive compound. All bolts and nuts fixing the parts to the explosion-proof surfaces as well as live and grounding terminals are equipped with spring lock washers to prevent self-unfastening. The temperature of the shell external surfaces in the most heated places does not exceed 120°C in normal actuator modes. The shell strength is tested by the manufacturer. The strength of each explosion-proof shell is tested by applying pressure of 1.0 MPa for at least 10 seconds. 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Accreditation certificate РОСС RU.0001.21MЭ67 Research Center Page 15 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Explosion-proof joints Fig. E.1 The figure schematically shows the places of explosion-proof joints (covers with the housing) Explosion-proof joints are shown in Table E.1. Table E.1 Joint Joint type Parameters Cylindrical Gap length ≥ 12.5 mm; Shell volume > 2,000 cm3; Maximum gap width ≤ 0.15 mm; Roughness Ra < 6.3 µm Cylindrical Gap length ≥ 12.5 mm; Shell volume > 2,000 cm3; Maximum gap width ≤ 0.15 mm; Roughness Ra < 6.3 µm Cover 3 and electrical compartment joint Cylindrical Gap length ≥ 12.5 mm; Shell volume > 2,000 cm3; Maximum gap width ≤ 0.15 mm; Roughness Ra < 6.3 µm Cover 4 and electrical compartment joint Threaded Number of complete intact solid threads ≥ 5; Thread axial length ≥ 8 mm Roughness Ra < 6.3 µm Light-transmitting part and cover 3 joint Sealed Length of the sealed joint ≥ 10 mm; Roughness Ra < 6.3 µm Control knob and cover 3 joint Control thrust rods and shafts Gap length ≥ 12.5 mm; Shell volume > 2,000 cm3; Maximum gap width ≤ 0.2 mm; Roughness Ra < 6.3 µm Mode selector knob and cover 3 joint Control thrust rods and shafts Gap length ≥ 12.5 mm; Shell volume > 2,000 cm3; Maximum gap width ≤ 0.2 mm; Roughness Ra < 6.3 µm Cable entries and the electrical compartment housing joint Threaded Number of complete intact solid threads ≥ 5; Thread axial length ≥ 8 mm Roughness Ra < 6.3 µm Cover 1 and electrical compartment joint Cover 2 and electrical compartment joint Test Laboratory of CJSC SRC TECHNOPROGRESS 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Accreditation certificate РОСС RU.0001.21MЭ67 Research Center Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Joint Joint type Parameters Cover and motor compartment housing joint Cylindrical Gap length ≥ 25 mm; Shell volume > 2,000 cm3; Maximum gap width ≤ 0.2 mm; Roughness Ra < 6.3 µm Shaft and bearing shield joint Cylindrical Gap length ≥ 40 mm; Shell volume > 2,000 cm3; Maximum gap width ≤ 0.4 mm; Roughness Ra < 6.3 µm Marking ElM Controls Serial No. Strongarm LLC Saint Petersburg Model mnfg date rpm (s) Item No. 43 rpm Motor Ph (V) Hz kW 5.28A (15 min) rpm A (max) DO NOT OPEN when in an explosive environment. DO NOT OPEN when energized. Use explosion-proof cable entries when connecting. Electric actuator ТЕС 2000 Explosion-proof, IP68 Explosion protection class 1 Ex d IIBT4 Certificate No. Fig. E. 1 Layout of the electric actuator TEC 2000 marking plate Described by: Test engineer / D.V. Kharitonov Page 16 of 18 Test Laboratory of CJSC SRC TECHNOPROGRESS 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 17 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Annex F to the Report No. 2869Ех List of the measuring tools used in the product specimen testing Name of the measuring tools and test equipment, measurement limit, error category Thermohygrometer VIT 2 Temperature Measuring range: +15... +40°С Error: ± 0.1°С, Humidity Measuring range: +20... 90% RH Error: 0.1% RH Visual measurement kit VIK-1 Kit components: 1. Measuring tape 5 m, ± 0.5 mm 2. Metal ruler 30 cm, ± 0.5 mm 3. Caliper with depth gauge 4. ShTs 1-150-0,05; err.cat. ± 0.05 mm 5. Setsquare UP 160x100 6. Radius gauges kit No. 2 7. Radius gauges kit No. 3 8. Probes kit No.2 9. Probes kit No.3 10. All-purpose welder’s gauge UShS-3 11. Weld seam legs gauge UShS-2 12. Measuring magnifier LI-3-10x, 2 cm ± 0.05 mm Serial number Next check (certification) date 17 06/01/2016 No. 08068556 No. 200803647 - 12/15/2015 Meteorological Barometer-Aneroid BAMM-1 Measurement range: 80... 106 kPa Error: main: ± 0.2 kPa additional: ± 0.5 kPa 292 10/01/2015 Dust chamber KTP-800 Volume: 800 cm3 Flow rate: 0... 16 m/s Maximum concentration g/m3 at least: 2 273 04/10/2016 1D157633 06/13/2015 27722340 06/01/2015 Caliper ShTsTs-1 Measurement range: 0...200 mm Error: 0.01 mm G55241 10/08/2015 Thermometer CENTER 304 Measuring range: -200... 1,370°С Resolution: 0.1°С Error: ±0.3°С 090706292 06/04/2015 215578 06/29/2016 GCN861322 01/13/2016 Measuring voltage converter E14-140-M-D DC voltage measuring range (positive or negative polarity) from 0.0001 to 10 V. Analog-to-digital converter frequency from 20 to 400 kHz Limits of permissible basic reduced error in voltage resupply ± 0.3 Roughness meter TR 100 Measuring range: Ra: 0.05... 10.0 µm Rz: 0.1 ...50 µm Error: ±15% Absolute pressure converter PAA-23SY Measuring range -1...50 bar. Error 0.5% Voltmeter GDM-8245 Voltage range: 10 µV... 1,200 V Current range: 10 nA ... 20 A Error: ± 0.02% 14/2 Kozhevnicheskaya str., 115114, Moscow tel./fax: +7 (495) 411 9436, http://www.tehnoprogress.ru e-mail: [email protected] Test Laboratory of CJSC SRC TECHNOPROGRESS Research Center Accreditation certificate РОСС RU.0001.21MЭ67 Page 18 of 18 Test Report No. 2869Ех The Test Report applies only to the tested specimens. Full or partial reproduction of the Test Report is allowed only with permission of the Test Laboratory of CJSC SRC TECHNOPROGRESS Name of the measuring tools and test equipment, measurement limit, error category Serial number Next check (certification) date Laboratory autotransformer TSGC2-15KVA 3 phases Adjustable voltage 0 ... 420 V. Maximum current 20 A no number Not required Compressor SV4/F-500.АV850/16 Operating pressure: 1.6 MPa Capacity: 850 l/min 105/13824 No check required ИО 21 12/03/2015 Drop-weight test installation UU-01 Report made by: Test engineer / D.V. Kharitonov
© Copyright 2026 Paperzz