Data sheet Hytork XL Sheet No.: D112, Rev. G February 2016 Date: Air Consumption XL26 to XL4581(Imperial Data) Actuator Model XL26 XL71 XL131 XL186 XL221 XL281 XL426 XL681 XL1127 XL1372 XL2586 XL4581 Actuator Model XL26 XL71 XL131 XL186 XL221 XL281 XL426 XL681 XL1127 XL1372 XL2586 XL4581 40 18 45 86 114 154 191 271 428 714 867 1585 2673 40 25 68 137 179 244 198 259 444 712 858 1521 2876 50 21 54 103 137 185 229 324 512 854 1037 1892 3184 50 31 83 167 218 298 237 309 532 851 1026 1812 3438 OUTWARD STROKE on Spring return and Double acting actuators 60 25 63 120 160 216 267 377 595 994 1207 2200 3696 Consumption per stroke (in3) Pressure in PSI / Outward stroke 70 80 28 32 72 80 137 154 183 205 247 278 305 343 431 484 679 763 1134 1273 1377 1547 2508 2815 4208 4719 90 36 89 172 228 309 381 537 846 1413 1717 3123 5231 100 39 98 189 251 340 419 590 930 1553 1887 3431 5742 120 46 116 223 296 401 495 697 1097 1833 2227 4046 6766 60 36 98 197 257 351 277 359 620 991 1193 2104 4001 Consumption per stroke (in3) Pressure in PSI / Inward stroke 70 80 42 47 113 127 227 257 296 335 404 458 317 357 410 460 707 795 1130 1269 1361 1528 2396 2687 4563 5126 90 52 142 287 374 511 396 510 883 1408 1696 2979 5688 100 58 157 316 413 565 436 560 971 1548 1864 3271 6251 120 69 186 376 492 671 516 661 1146 1826 2199 3854 7376 INWARD STROKE on Double acting actuators w w w . H y t o r k . c o m Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.hytork.com or from your nearest Valve Automation Center USA: +1 813 630 2255 (fax 630 9449) UK: +44 191 5180020 (fax 5180032)