B ---Ill> CSA INTERNATIONAL Certificate of Compliance Certificate: 1796497 Master Contract: Project: 2220552 Date Issued: October 7, 2009 Issued to: Emerson Process Management Valve Automation Div. EL-0-Matic B.V. Asveldweg 11 7556 AE Hengelo THE NETHERLANDS 174756 The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. ~® c us Issued by: Hans Werner Zeller Authorized by: M.H.J. Hoendervangers Area Director Europe /l 1JJ/~v~~ PRODUCTS CLASS 2252 05 - PROCESS CONTROL EQUIPMENT CLASS 2252 85- PROCESS CONTROL EQUIPMENT-Certified to US Standards PART A Valve Actuator Controller FieldQ, Model QC01, QC02, QC03, QC04, QC30, QC31 and QC34, permanently connected, rated: QC02: 85-254 V, 50/60Hz, 2,85 W, QC01: 24 Vdc, 0,1 A, 2,5 W, QC03, QC04: 30 Vdc, 300 rnA, 1,2 W, QC30: 24-31,6 V, 3 W,QC31: 11 -25 Vdc, 120mA-75mA, QC34: 9-30 Vdc, 22 rnA NOTE: The above model QC02 is Equipment Class I, Pollution Degree 3. PARTB: Valve Switchbox Field Q, Model QC14, QC11, QC12, QC13, QC21, QC22 and QC23, permanently connected, rated: QC14: 24 Vdc, 0,9 W, QC11: 24 Vdc, 1,3 W, QC12: 115 Vac, 50/60Hz, 1,3 W, QC13: 230 Vac, 50/60Hz, 1,9 W, QC21: 24 Vdc, 3 W, QC22: 115 Vac, 50/60Hz, 5 W, QC23: 230 Vac, 50/60Hz, 5 W Outputs: Potential free contact rating: Switches: 30 Vdc/5 A, 125 Vac/5 A, 125 Vdc/0,5 A, 250 Vac/5 A, 250 Vdc/0,25 A. Proximity switches: 16 Vdc/0,034W. or 140 V/0,2 A D 507 Rev. 2004-06-30 P eI Certificate: Project: I796497 2220552 APPLICABLE REQUIREMENTS 0 ------<II> CSA INTERNATIONAL Master Contract: I74756 Date Issued: October 7, 2009 CAN/CSA-C22.2 No. 610IO.I-04 Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part I: General Requirements UL Std. No. 6I 0 I 0-I (2"d Edition) Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use- Part I: General Requirements CONDITIONS OF ACCEPTABILITY PART A: The units are evaluated for an ambient temperature of 80 oc For model QC02 the membrane key-board is only accessible by means of a tool. Only trained personal may control the unit. For model QC02 the unit may only be used in combination with a pneumatic module mounted on an actuator to prevent against electric shock. Models QCOI, QC03, QC04, QC30, QC3I and QC34 shall be powered by a DC voltage< 60 Vdc which is separated from hazardous live by double or reinforced insulation at the source of the supply with a power limitation of I 50 VA. Also all input and output connections shall be separated from hazardous live by double or reinforced insulation with a voltage < 60 V de PARTB: The input/output specifications and following instructions for building-in are given by the manufacturer. The units are evaluated for an ambient temperature of: 50 oc (QCI4), 80 oc (QCII, QCI2, QC13), 60 °C (QC2I, QC22, QC23) Models QC I4, QC II and QC21 shall be powered by a DC voltage < 60 V de which is separated from hazardous live by double or reinforced insulation at the source of the supply with a power limitation of 150 VA. MARKINGS The following markings appear on the product and may be described in further detail in the Certification Report Supplement, Section C: I. 2. 3. 4. 5. Submittor's identification (company name and/or file number and/or registered tradename ); Model designation; Electrical rating; (only for PART A) Date of manufacture (or traceable serial number); The CSA Monogram with C/US subscript; D 507 Rev. 2004-06-30 Pa e2 0 -------e CSA INTERNATIONAL Supplement to Certificate of Compliance Certificate: 1796497 Master Contract: 174756 The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Product Certification History Project Date Description 2220552 October 7, 2009 June 3, 2009 Update to report 1796497. Additional changes of edition 4 2186761 Update to report 1796497. Addition of low voltage model QC31. Small lay-out changes on QC31 model PWB' s. Minor changes in critical components. 2064112 September 18, Update to report 1796497. Addition of low voltage model QC31. Small 2008 lay-out changes on QC31 model PWB' s. Minor changes in critical components. 2017277 April 16, 2008 Update to report 1796497. Addition of low voltage models QC01, QC03, QC04, QC30 and QC34. Small lay-out changes on QC02 model PWB's. Minor changes in critical components 1796497 D D 507 Rev. 2004-06-30 May 29, 2006 Original cCSAusCertification.ofFieldQ model QC02 P eI
© Copyright 2026 Paperzz