G IN R I W LD E IF G IN R I W R O T A U T C A EDI IFC EP S ES I W RE TH O SSE LN U - .S RE TE M LIL I M IN ER A NSO IS NE IM D 5 .2 0 ± = DN A SR RU B LL A EV O M ER - S.R EN RO C PR A H S TSI IM L CEN AR EL OT ES I W RE H OT SS LEN U .10 ± = : DE IF IC EP S INPUT 4-20mA + + *4 N W O R B N W O R B N W O R B CONNECT A MILLIAMPMETER OR JUMPER WIRE L1 L2 L3 1 BLACK = 240 V WHITE = 400 V RED = 460 V 40 4 N W O R B N W O R B T1 T2 T3 *3 SPEED CONTROL 37 4 SC 40 4A Q1 *1 W O LLE Y Q2 19 5 3 *2 COM NO S NC LS 1 CLOSE 8 7 *2 W LO LE Y W O LLE D E Y R K C A LB 2 6 13 E T I H W R2 R3 COM NC NO TS CLOSE NO 9 14 E U LB N E E R G R2-R3 4k7 25W COM NC NC 21 60 K ACL B 61 *4 19 10 20 69 + AUX. BOARD LC 72 71 70 W O LLE Y ET I H W ET I H W TEI H W 73 W O LLE Y - 74 EN E R G D E R 65 49 TEI H W NO 22 K CA LB E U LB NO WITHOUT SPEEDCONTROL SC WIRES Q1 AND Q2 TO TERMINAL 41 MOD * 2 LINK FOR TORQUE SEATED VALVE * 3 MOTOR WIRING EL 100/150 EL 200/2500 T1 = BLUE T1 = BROWN T2 = BLACK T2 = BLACK T3 = BROWN T3 = BLUE LOCAL-REMOTE LC FEEDBACK POT EU LB NC 23 D E R 24 W O LLE Y 25 26 TEI H W COM TS OPEN EN E R G 67 2 LS LIMIT SWITCH 5 LIMIT SWITCH 6 75 NO 66 COM NC NO 48 64 W O LLE Y COM *4 K ACL B 21 K C A LB E U LB 49 68 63 K ACL B 48 W O LL E Y K C LA B 59 E LU B COM LS 2 OPEN 20 E U LB E U LB OPEN CLOSE + 41 42 51 45 43 50 *6 M MOTOR 3 MOD CONTROL SERIES II 45 41 F1 K C LA B 62 ORANGE W O R B E U LB 2A N W O R B 37 T1 110V~ 25VA N Q2 Q1 +46 - 44 HEATER 10W EL 2500 2X10W *5 OUTPUT 4-20mA - BROWN ° 2 1/ ± = RA UL X . .X .X NG X X X A .50 ± = 3PH INCOMING POWER N EE R G 27 EU LB COM NO NC NC 0 CLOSE-O-OPEN LIMIT SWITCH 3 LIMIT SWITCH 4 *1 LOCAL CONTROL EX *4 IN EXPLOSION PROOF EXECUTION BOTH LOCAL/REMOTE AND CLOSE/STOP/OPEN SWITCHES ARE *5 COMBINED INTO ONE SWITCH *6 WITHOUT LOCAL CONTROL LC POTMETER TO TERMINAL 19, 20, 21 MOD INPUT 4-20 mA TO TERMINAL 48, 49, MOD EL1200 - EL 2500 Q1/Q2: USE 16A RELAY CONTACTS RESISTORS ONLY IN COMBINATION WITH SPEEDCONTROL IMPORTANT LIMIT SWITCHES SHOWN IN MID STROKE KIT OPTIONS, LC _ 2LS _ SC, FROM EL200 ONLY ON ORDER KIT OPTIONS SHOWN IN DOTTED LINES Format : I N T E R N A T I O N A L LOCATION HENGELO (O) THE NETHERLANDS Material : Treatment : - Title : A3 Each actuator must be powered through its own individual switch or relay contacts to avoid cross feed between two or more actuators Drn. : Scale : Wiring diagram options 990.40.031 Date : - motor 3PH+4-20mA MOD+int, EL100-EL2500 WP/XP Drw.nr. : - AB ENOC nr. : 05/10/2000 Par. : Date : H-0786 03/07/2001 RS State : Released Rev. : B
© Copyright 2026 Paperzz