INPUT
4-20mA
+
+
*4
N
W
O
R
B
N
W
O
R
B
N
W
O
R
B
CONNECT A MILLIAMPMETER
OR JUMPER WIRE
L1 L2 L3
1
BLACK = 240 V
WHITE = 400 V
RED = 460 V
40
4
N
W
O
R
B
N
W
O
R
B
T1 T2 T3
*3
SPEED CONTROL
37
4
SC
40
4A
Q1
*1
W
O
LLE
Y
Q2
19
5
3
*2
COM
NO
S
NC
LS 1
CLOSE
8
7
*2
W
LO
LE
Y
W
O
LLE D
E
Y R
K
C
A
LB
2
6 13
E
T
I
H
W
R2 R3
COM
NC NO
TS
CLOSE
NO
9 14
E
U
LB
N
E
E
R
G
R2-R3
4k7 25W
COM
NC
NC
21
60
K
ACL
B
61
*4
19
10
20
69
+
AUX. BOARD
LC
72
71 70
W
O
LLE
Y
ET
I
H
W
ET
I
H
W
TEI
H
W
73
W
O
LLE
Y
-
74
EN
E
R
G
D
E
R
65
49
TEI
H
W
NO
22
K
CA
LB
E
U
LB
NO
WITHOUT SPEEDCONTROL SC
WIRES Q1 AND Q2 TO TERMINAL 41 MOD
* 2 LINK FOR TORQUE SEATED VALVE
* 3 MOTOR WIRING
EL 100/150
EL 200/2500
T1 = BLUE
T1 = BROWN
T2 = BLACK
T2 = BLACK
T3 = BROWN
T3 = BLUE
LOCAL-REMOTE LC
FEEDBACK POT
EU
LB
NC
23
D
E
R
24
W
O
LLE
Y
25
26
TEI
H
W
COM
TS
OPEN
EN
E
R
G
67
2 LS
LIMIT SWITCH 5 LIMIT SWITCH 6
75
NO
66
COM
NC
NO
48
64
W
O
LLE
Y
COM
*4
K
ACL
B
21
K
C
A
LB
E
U
LB
49
68
63
K
ACL
B
48
W
O
LL
E
Y
K
C
LA
B
59
E
LU
B
COM
LS 2
OPEN
20
E
U
LB
E
U
LB
OPEN
CLOSE
+
41 42 51
45
43 50
*6
M
MOTOR 3
MOD CONTROL SERIES II
45 41
F1
K
C
LA
B
62
ORANGE
W
O
R
B
E
U
LB
2A
N
W
O
R
B
37
T1
110V~
25VA N
Q2
Q1
+46
- 44
HEATER 10W
EL 2500 2X10W
*5
OUTPUT
4-20mA
-
BROWN
°
2
1/
±
=
RA
UL
X
. .X .X NG
X X X A
.50
±
=
3PH
INCOMING POWER
N
EE
R
G
27
EU
LB
COM
NO
NC
NC
0
CLOSE-O-OPEN
LIMIT SWITCH 3 LIMIT SWITCH 4
*1
LOCAL CONTROL EX
*4
IN EXPLOSION PROOF EXECUTION
BOTH LOCAL/REMOTE AND
CLOSE/STOP/OPEN SWITCHES ARE
*5
COMBINED INTO ONE SWITCH
*6
WITHOUT LOCAL CONTROL LC
POTMETER TO TERMINAL 19, 20, 21 MOD
INPUT 4-20 mA TO TERMINAL 48, 49, MOD
EL1200 - EL 2500
Q1/Q2: USE 16A RELAY CONTACTS
RESISTORS ONLY IN COMBINATION WITH SPEEDCONTROL
IMPORTANT
LIMIT SWITCHES SHOWN IN MID STROKE
KIT OPTIONS, LC _ 2LS _ SC, FROM EL200 ONLY ON ORDER
KIT OPTIONS SHOWN IN DOTTED LINES
Format :
I
N
T
E
R
N
A
T
I
O
N
A
L
LOCATION HENGELO (O) THE NETHERLANDS
Material :
Treatment :
-
Title :
A3
Each actuator must be powered through
its own individual switch or relay
contacts to avoid cross feed between
two or more actuators
Drn. :
Scale :
Wiring diagram options
990.40.031
Date :
-
motor 3PH+4-20mA MOD+int, EL100-EL2500 WP/XP
Drw.nr. :
-
AB
ENOC nr. :
05/10/2000
Par. :
Date :
H-0786 03/07/2001 RS
State :
Released
Rev. :
B