G IN R I W LD E IF G IN R I W R O T A U T C A EDI IFC EP S ES I W RE TH O SSE LN U - .S RE TE M LIL I M IN ER A NSO IS NE IM D 5 .2 0 ± = DN A SR RU B LL A EV O M ER - S.R EN RO C PR A H S TSI IM L CEN AR EL OT ES I W RE H OT SS LEN U .10 ± = : DE IF IC EP S N W O R B N W O R B +46 40 4 SPEED CONTROL 37 4 SC 40 4A F1 2A Q1 *1 41 42 51 45 43 50 W O LLE Y Q2 E U LB R2 R3 OPEN CLOSE 19 *6 5 3 *2 2 COM NO S 6 13 NC LS 1 CLOSE 8 7 *2 W LO LE Y W O LLE D E Y R K C A LB M MOTOR 3 MOD CONTROL SERIES II ORANGE E LU B K C LA B N W O R B T1 T2 T3 *3 - 62 45 41 37 T1 110V~ 25VA HEATER 10W EL 2500 2X10W Q2 N W O R B + N W O R B BLACK = 240 V WHITE = 400 V RED = 460 V N W O R B INPUT 0-10V - L1 L2 L3 1 Q1 *5 OUTPUT 0-10V + BROWN ° 2 1/ ± = RA UL X . .X .X NG X X X A .50 ± = 3PH INCOMING POWER E T I H W COM NC NO NO TS CLOSE 9 14 E U LB N E E R G COM NC NC LS 2 OPEN WITHOUT SPEEDCONTROL SC WIRES Q1 AND Q2 TO TERMINAL 41 MOD * 2 LINK FOR TORQUE SEATED VALVE * 3 MOTOR WIRING 59 21 60 CK AL B 61 *4 19 E U LB 20 K C A LB 68 49 CK AL B + AUX. BOARD LC 72 71 70 ET I H W ET I H W ET I H W 48 73 W O LLE Y - 74 EN E R G 49 22 K CA LB E U LB NO LOCAL-REMOTE LC 66 EN E R G 67 EU LB NC 2 LS LIMIT SWITCH 5 LIMIT SWITCH 6 75 NO FEEDBACK POT TEI H W NO 23 D E R 24 W O LLE Y COM TS OPEN 65 COM NC NO 69 D E R 64 W O LLE Y COM *4 21 W O LLE Y K ACL B 48 W LO LE Y K C LA B E LU B 10 E LU B COM R2-R3 4k7 25W + 20 63 NC 25 TEI H W 26 N EE R G 27 EU LB COM NO NC 0 LIMIT SWITCH 3 LIMIT SWITCH 4 CLOSE-O-OPEN *1 EL 100/150 LOCAL CONTROL EX IN EXPLOSION PROOF EXECUTION BOTH LOCAL/REMOTE AND CLOSE/STOP/OPEN SWITCHES ARE COMBINED INTO ONE SWITCH IMPORTANT EL 200/2500 Each actuator must be powered through LIMIT SWITCHES SHOWN IN MID STROKE T1 = BLUE T1 = BROWN its own individual switch or relay KIT OPTIONS, LC _ 2LS _ SC, FROM EL200 ONLY ON ORDER T2 = BLACK T2 = BLACK contacts to avoid cross feed between KIT OPTIONS SHOWN IN DOTTED LINES T3 = BROWN T3 = BLUE two or more actuators * 4 WITHOUT LOCAL CONTROL LC Format : Drn. : Scale : Date : RS 03/11/2000 POTMETER TO TERMINAL 19, 20, 21 MOD A3 I N T E R N A T I O N A L ENOC nr. : Date : Par. : Title : INPUT 0-10 V TO TERMINAL 48, 49, MOD LOCATION HENGELO (O) THE NETHERLANDS H-0786 03/07/2001 RS Material : * 5 EL1200 - EL 2500 State : Released motor 3PH + 0-10V MOD+int, EL100-EL2500 WP/XP Q1/Q2: USE 16A RELAY CONTACTS Drw.nr. : Rev. : Treatment : * 6 RESISTORS ONLY IN COMBINATION WITH SPEEDCONTROL - Wiring diagram options 990.40.039 B
© Copyright 2026 Paperzz