Installation Instruction 990.40.101 Rev. C January 2012 Installation Instructions Positioners Series II Read these instructions completely before attempting to install calibrate or troubleshoot the positioner. * Before starting check the kit to ensure that all parts are available and the MOD card control signal is the same as required for the application. * There are two versions: 1. 4-20mA Control signal 2. 0-10V Control signal 1 1 1 1 3 3 1 Drive pinion (large Potentiometer pinion (small) Potentiometer spacer Potentiometer 10K Print spacer Spacer/screw Positioner card Used on EL: 55 100-1600 * * * * * * * * * * * * Mechanical Installation. Remove actuator cover (1) and dial (2). 1. Remove actuator cover (1) and dial (2). 2. Mount potmeter (6) on motor top plate using lock nut and spacer (5). 3. Slide potmeter pinion (small pinion, 4) over potmeter-shaft and tighten screw. 4. Slide drive pinion (large pinion, 3) over indicator shaft. 5. Ensure that end of travel limit switches have been set correctly. For direct action: Set the actuator in the close position. Turn the potentiometer fully CCW and then about 20° CW then tighten drive pinion fixing screw. For reverse action: Set the actuator in the open position. Turn the potentiometer fully CW and then about 20° CCW then tighten drive pinion fixing screw. 6 Potentiometer setting Span Zero Limitswitch and rotor Motor Fail Action jumpers 19 20 21 48 49 44 46 Indication shaft Fig. 3 MOD board assembly Re-transmit output Command signal 6a.For EL35/55 only; Insert three print spacers (9) into motor top plate and place positioner board over indicator shaft so that 3 spacers locate correctly into three holes in circuit board. Now press into place. 6b.For EL100 up to EL1600; Place positioner board over indicator shaft and mount to motor top plate using 3 screws and plastic spacers (9) (the screws engage with 3 nuts welded to top motor plate). 7. Connect three potentiometer leads to positioner terminals (see fig 11.5): For direct action: 19-Blue 20-Black For reverse action: 19-Yellow 20-Black 21-Yellow. 21-Blue. 8. 1 phase: Remove links from 2-10 and 3-7. 3 phase: Disconnect 7 and 10 from the contactors. 9. IMPORTANT! Check or set the voltage switch, on the positioner board, to the actual power supply voltage (see fig 11.4). Feedback potentiometer Fig. 5 Electrical connections and settings Fail Action Setting 1. All signal wires are to be free of electrical noise and interference. It is recommended that all signal wires be run in shielded cable. 2. If unit gives a 20 mA reading at closed valve position or a 4 mA reading at open valve position, check potentiometer wiring (direct action). 3. If unit moves towards closed position when a higher command signal (or visa versa) is given, check motor wiring (direct action). 4. If unit does not move to the fully open or closed position, check zero, span and alignment settings. 5. If actuator is closed, and it is not possible to adjust the zero’ trimmer so that a 4mA reading is achieved, re-install the potentiometer and make sure that the clockwise angle is between 10° and 20°. 1 Default setting: When the jumper is set at J2 and J3, the positioner is set to fail-safe. This means that if the input is disconnected the actuator will stay at its last position. 2 When the jumpers are set at J1 and J4, the positioner is set to fail to 4mA. This means that if the input is disconnected the actuator will go to the 4mA position (‘Close’ for direct and ‘Open’ for revers action). For reverse action, fail to close is not possible. To achieve a proper functioning of the positioner, this setting has to be made, even though the signal may not be required. 37 40 41 43 42 50 45 51 45 4-20mA 220 V supply voltage setting 110 V supply voltage setting 1. Apply power to the unit (terminals 11 and 12). Check voltage selector switch. 2. Connect a milli-amp meter (preferably digital) to terminals 44 (-) and 46 (+). Deadband setting Voltage selector switch setting (not on 3 Phase) Wiring diagram see drawing nr.: Actuator Phase EL 55 1 EL100-1600 1 EL100-2500 3 Drw. 990.40.025 990.40.030 990.40.031 3. Normally the ‘Deadband’ is set so that the actuator will not track variations of less than ±0.5% in the process control signal. Minimum deadband setting (fully ccw) is usually satisfactory, but if the actuator seems to hunt it may be necessary to use a higher deadband setting (turn ‘Deadband’ trimmer clock wise (CW) for higher setting). All rights reserved. Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.El-O-Matic.com or from your nearest Valve Automation Center: America’s: +1 813 630 2255 (fax +1 630 9449) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 626 24 515 (fax +65 626 80 028) Copyright © 2009 Emerson Electric Co. w w w . e l - o - m a t i c . c o m 4. Connect a variable milli-amp source to terminals 48 (+) and 49(-), and apply a 12 mA current. 5. The actuator should now move to an intermediate position. Adjust the ‘Alignment’ trimmer so that a 12 mA reading is achieved on the meter connected to terminals 44 and 46. 6. Turn the actuator to the fully closed position (just before limit switch trips) and adjust the ‘Zero’ trimmer so that a 4 mA reading is achieved. 7. Turn the actuator to the fully open position ( just before limit switch trips) and adjust ‘Span’ trimmer so that a 20 mA reading is achieved. 8. Because the zero and span trimmers affect one another, it may be necessary to alternate between the max. and min. signal once or twice more and ‘fine tune’ the zero and span controls until the correct reading is achieved. 9. If the output signal is not required the meter should be replaced by a wire link. Important notes: Output signal setting. 10.Make connections as shown on the wiring diagram. Fig. 2 Deadband Alignment Top motor Fig. 4 About 20° clockwise 4-20mA 5 19 20 21 48 49 44 46 Fully counter clockwise 37 40 41 43 42 50 45 51 45 4 9 Electrical Installation. Fig. 1 Alignment of in- and output signals. 3 16 plate Pos Qty Description 3 4 5 6 9 9 16 MOD 4-20mA Reverse action 1 The MOD-Board can also be used for revers action. This means that a 4mA signal is the ‘Open’ and 20mA is the ‘Closed’ position. 2 To set the actuator for revers action, make the connections as shown on the wiring diagrams. Except the wiring of the limit switches, the motor and the potentiometer (see table (‘Connections for revers action). Connections for reverse action Wiring of : To Mod Board: 2 Motor 3 4 7 Limit switches 10 yellow Potmeter black blue 43 42 41 51 50 19 20 21 Installation Instruction 990.40.101 Rev. C January 2012 4A 4 37 40 M SC COM NO NC COM NO COM NC NO NC NO NC LIMIT SW.2 OPEN FEEDBACK POT NO NC LIMIT SWITCH 6 LIMIT SWITCH 4 LIMIT SWITCH 5 IMPORTANT Each actuator must be powered through its own individual switch or relay contacts to avoid cross feed between two or more actuators. LIMIT SWITCHES SHOWN IN MID STROKE KIT OPTIONS, LC _ 2LS _ SC , ONLY ON ORDER KIT OPTIONS SHOWN IN DOTTED LINES * 1 NO WIRE BY SPEEDCONTROL SC * 2 WITHOUT LOCAL CONTROL LCPOTMETER TO TERMINAL 19, 20, 21 MOD INPUT 4-20 mA TO TERMINAL 48, 49, MOD *6 0 LIMIT SWITCHES SHOWN IN MID STROKE I N T E R N A T I O N A L All rights reserved. Copyright © Emerson Process Management. The information in this document is subject to change without notice. Updated data sheets can be obtained from our website www.El-O-Matic.com or from your nearest Valve Automation Center: America’s: +1 813 630 2255 (fax +1 630 9449) Europe: +31 74 256 10 10 (fax +31 74 291 09 38) Asia/Pacific: +65 626 24 515 (fax +65 626 80 028) Copyright © 2009 Emerson Electric Co. w w w . e l - o - m a t i c . c o m LIMIT SWITCHES SHOWN IN MID STROKE 2 LS LOCAL-REMOTE LC CLOSE-O-OPEN LIMIT SWITCH 3 67 BLUE GREEN YELLOW 66 S SPEED CONTROL LIMIT SW.1 CLOSE 65 COM NC 0 MOTOR 1 64 COM COM NO 63 WHITE 62 RED 27 BLACK 26 GREEN 25 BLUE 24 WHITE BLACK 75 RED 74 YELLOW WHITE 73 23 22 YELLOW 71 70 72 WHITE 21 WHITE BLUE 20 YELLOW 19 10 BLACK 9 BLUE WHITE 8 GREEN 7 YELLOW 6 RED BLACK BROWN BROWN BROWN BROWN PURPLE C 5 *2 4 3 BLACK 2 BLUE 1 - + AUX. BOARD LC 11 49 48 BROWN 69 68 *2 61 HEATER 10W 60 49 BLACK 12 59 48 21 BLUE *1 20 19 51 45 SC 37 50 12 BLACK 45 - 11 40 BLACK 41 43 37 MOD CONTROL SERIES + BLUE 42 46 44 BLACK - + LIVE SC 40 YELLOW ACTUATOR WIRING CONNECT A MILLIAMPMETER OR JUMPER WIRE NEUTRAL + INPUT 4-20mA INCOMING POWER BROWN FIELD WIRING - OUTPUT 4-20mA
© Copyright 2026 Paperzz