Rosemount® CTS - TGU53 Product Data Sheet Ed 02 Technical Data - Gauge Technical Data - Still Pipe Spherical Tanks Measuring range 0 to 52 m Operating accuracy ± 5 mm Instrument accuracy ± 3 mm Ambient operating temperature Dimension Ø 114.3 x 4 mm, extending throughout the full height of the tank, up to 6 m segments -40 to +70º C Material Aluminium 5083-0 Product Range Liquefied gases according to IMO IGC code Purge Nozzle Flange: requested size (ANSI ½”) Thread & plug (option); to suit connections (G 3/8”) Temperature application Up to 6 primary inputs for 4-wire Pt100 sensors and up to 6 secondary inputs Temperature range -165º C to +100º C Technical Data - Still Pipe Membrane Tanks Temperature system accuracy ± 0.2º C Dimension Pressure application Evaluated to the directives EN 13445:2009 Ø 114.3 x 3.6 mm, extending throughout the full height of the tank, up to 6 m segments Pressure sensor range 0.8 to 2 Bar (absolute) Material Pressure sensor accuracy ± 3 mbar 304 L stainless steel for GT 96/CS 1 and Mark III Weight 33 kg (gauge socket and still pipe excluded) Purge Nozzle Cable glands, standard M32 for cable with outer diameter 15-21 mm Flange: requested size (ANSI ½”) Thread & plug (option); to suit connections (G 3/8”) Number of radar channels One or two Number of cable inlets 2 Flange fittings See installation drawings Technical Data - Thermowell Material facing tank atmosphere Stainless steel 304L/316L, PTFE (PolyTetraFluoroEthylene) Dimension Ø 33 mm x 3 mm Material facing deck Stainless steel 316/316L Material 304 L stainless steel Explosion protection Intrinsically safe: ATEX: II 1G Ex ia T4 Ga II 1 G, Ex ia IIC T4 No. of temp. sensors 1 - 6 sensors/thermowell Sealing IP66 The Emerson logo is a trademark and service mark of Emerson Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. www.EmersonProcesss.com/mtm February 2013 Ed 02 Rosemount® CTS - TGU 53 Tank Gauge Unit The Tank Gauge Unit, TGU 53, is a liquefied gas gauge used within the Rosemount CTS system. It is an intrinsically safe tank radar mounted on deck. The radar transmission is guided through a full length still pipe measuring the surface of the product. Using our own reliable method, the signal is digitally processed to achieve a very accurate reading of the distance to the surface. By using unique patented technologies two radar measurements can be done separately and independently from each other in one gauge. One radar channel measurement can be chosen with possibility to upgrade to dual channel configuration. ©2013 Emerson Process Management. All rights reserved. Emerson Process Management Rosemount Tank Radar AB Box 13045 SE-40251 Sweden T +46 31 337 00 00 F +46 31 25 30 22 Product Data Sheet February 2013 The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services described herein or their use or applicability. Standard Terms and Conditions of Sale can be issued by contacting Rosemount Tank Radar AB. We reserve the right to modify or improve the designs and specifications of our products at any time without notice. Rosemount Tank Radar AB accepts no responsibility for any errors that may appear in this publication. The most accurate and reliable level measurement from the pioneers in radar level gauging and LNG CTS systems. All electronics is outside the tank, integrated under one cover. Measures close to tank bottom due to patented Array Attenuator. Dual channel measurement with one Tank Gauge Unit and one Still Pipe, enabling Primary and Secondary CTS with less hardware. The Liquefied Gas Gauge is an integrated part of the Rosemount Custody Transfer System. Factory Acceptance Tested using Moveable Echo to simulate any liquid level in tank. Rosemount® CTS - TGU53 February 2013 February 2013 Rosemount® CTS - TGU53 The Gauge The Tank Gauge Unit (TGU 53) incorporates measurement of Level, Temperature and Pressure in the same integrated unit. All the electronics can be exchanged from the deck without opening the tank to atmosphere. One TGU 53 can measure two levels independently by using separate electronic boards, connected to the same antenna. This enables Primary and Secondary CTS levels to be measured with only one single still pipe installed in the tank. TGU 53 also incorporates up to 6+6 Resistance Temperature Detector sensors (RTD 4-wire Pt100) for measurement of temperature in the tank, and up to two Pressure Sensors for measurement of the vapor pressure. The Still Pipe The complete Still Pipe assembly consists of a Gauge Socket, joined Still Pipe segments with equalizing holes and a Verification Pin. Two vented Thermowells run alongside the radar Still Pipe and in these the Temperature Sensors are inserted. Brackets for securing the Still Pipe and the Thermowells to the pump tower structure are used in accordance with the appropriate tank engineering practice and are included with the equipment. The Array Attenuator The Array Attenuator is a patented device located below the still pipe for absorbing the microwave reflection from the tank bottom. This enables level measurement even with very low liquid levels in the tank. The bottom Temperature Sensor can be mounted onto the Array Attenuator assembly. 2 www.EmersonProcess.com www.EmersonProcess.com 3
© Copyright 2025 Paperzz