Rosemount Tank Gauging System System Configuration Data Sheet February 2015 00806-0100-5100, Rev AA System Information In order to be able to correctly configure and assemble the parts of the system, the System Configuration Data Sheet must be filled in. It is also necessary to provide drawings of the tank farm layout with proposed location of Level Gauges, Field Displays, Tank Hubs, System Hubs, Field Bus Modems, TankMaster etc. Note The information on this form is used for tagging signs, temperature sensor specification and wireless network information only. No setting of device data base is done based on information on this data sheet. Please state all distances in metric units. Customer Information Rosemount Tank Gauging system number:_______________________ Installation site: ____________________________________________ Total number of tanks: _______________________________________ Year and Month: ____________________________________________ End Customer:_____________________________________________ Contact Name: _____________________________________________ Telephone: ________________________________________________ P.O. Reference No:___________________________________________ Customer Signoff: ______________________________________________________________________________________________________ Email address: _________________________________________________________________________________________________________ System Overview 5400 2240S 5900S 5900S 2-in-1 2230 5900S 5400 5900C 3051S 2240S 775 2410 644 1420 Smart Wireless Gateway Alternative Connection to DCS/PLC/SCADA/Host TankMaster PC in Network Alternative Connection to DCS/PLC/SCADA/Host 2160 3308 3051S 644 Alarm 5300 ESD 2410 5900S Radar Level Gauge (2-in-1 optional) Still-pipe Array Horn 5900C Radar Level Gauge LPG/LNG Still-pipe Array Cone 2460 System Hub 2410 2410 2240S Multi-input TemperatureTransmitter 2180 Field Bus Modem TankMaster.net for Web Access www Alternative Connection to DCS/PLC/SCADA/Host 2120/2130/2160 Liquid Level Switch Smart Wireless THUM Adapter LPG/LNG 5400 Radar Level Transmitter 5300 Guided 3308 Wireless Wave Radar Guided Wave Radar Transmitter Transmitter 2410 Tank Hub bolic Parabolic 3051S Pressure Transmitter 2230 Graphical Field Display 565/566 765 Multiple Spot Multiple Spot Temperature and Temperature Water Level Sensor Sensor www.rosemount-tg.com 644 Temperature Transmitter with Single Point Temperature Sensor 1 3 5 7 . Fn 2 4 6 8 0 9 - Field Communicator Rosemount Tank Gauging System Tank Name 2 Antenna Type Tank Product Tank Height 5900 Radar (mm) Tag Name February 2015 2410 Hub Tag Name 2240 Temp 2230 Display Tx Tag Name Tag Name Note Rosemount Tank Gauging System February 2015 Tag/ Tank name L0 Temp sensor length include WLS (mm) Position of temperature spot elements from sensor bottom end (mm) T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 T16 3 Rosemount Tank Gauging System Multiple Spot Temperature Sensor with WLS 350 mm 350 mm Multiple Spot Temperature Sensor February 2015 Min. 1000 mm Min. 1000 mm Max Filling Level Max Filling Level T1 LW LW T1 T2 Highest temperature element <T16 T3 Min. 150 mm L0 L LT Min. 500 mm T2 T3 L0 L LT Highest temperature element <T16 Min. 500 mm L= Distance from nozzle top to tank bottom L= Distance from nozzle top to tank bottom LW = Height of weight LW = Height of weight LT = Total length of temp sensor and WLS LT = Total length of temp sensor and WLS L0 = LT + 350 (mm) L0 = LT + 350 (mm) Where: 350 = Distance from top of sensor to lower thread (exact position of flange can be adjusted up or down about 100 mm at installation using the nuts and the 256 mm thread length) Where: 350 = Distance from top of sensor to lower thread (exact position of flange can be adjusted up or down about 100 mm at installation using the nuts and the 256 mm thread length) Lowest temp. spot (T1) 0,5 - 1,0 m above tank bottom, min 300 mm from eye bolt in level sensor Lowest temp. spot (T1) 0,5 - 1,0 m above tank bottom, min 300 mm from eye bolt in level sensor Highest temp. spot 0,5 - 1,0 m below max level, min 1000 mm from top of sensor Highest temp. spot 0,5 - 1,0 m below max level, min 1000 mm from top of sensor 4 Rosemount Tank Gauging System February 2015 Wireless Network Design (if included) For complete help on preplanning of a Tank Gauging Wireless network see Reference Manual 300570EN. Tools to be used are a scaled sketch of the installation site and AMS Wireless SNAP-ON Software. Rule of 5 Found to be OK: Comments: _____________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ Rule of 3 Found to be OK: Comments:____________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ Rule of 25% Found to be OK: Comments:____________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ _____________________________________________________________________________________________________________________________________ Make a small sketch of the planned Wireless Network or send a copy of the SNAP-ON design picture 5 Rosemount Tank Gauging System 00806-0100-5100, Rev AA System Configuration Data Sheet February 2015 Rosemount Tank Gauging World Headquarters Emerson Process Management Box 130 45 SE-402 51 Gothenburg SWEDEN +46 31 337 00 00 +46 31 25 30 22 [email protected] Rosemount Tank Gauging North America Inc. Emerson Process Management 6005 Rogerdale Road Mail Stop NC 136 77072 Texas, Houston, USA +1 281 988 4000 +1 800 722 2865 [email protected] Latin America Regional Office Emerson Process Management 1300 Concord Terrace, Suite 400 Sunrise, Florida, 33323, USA +1 954 846 5030 +1 954 846 5121 [email protected] Asia Pacific Regional Office Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 +65 6777 8211 +65 6777 0947 [email protected] Rosemount Tank Gauging Middle East & Africa. Emerson Process Management P. O Box 20048 Manama, Bahrain +973 1722 6610 +973 1722 7771 [email protected] The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and Rosemount logotype are registered trademarks of Rosemount Inc. All other marks are the property of their respective owners. © 2015 Rosemount Tank Radar AB all rights reserved.
© Copyright 2026 Paperzz