Rosemount Tank Gauging System Configuration Data Sheet

Rosemount Tank Gauging System
System Configuration Data Sheet
February 2015
00806-0100-5100, Rev AA
System Information
In order to be able to correctly configure and assemble the parts of the system, the System Configuration Data Sheet must be filled
in. It is also necessary to provide drawings of the tank farm layout with proposed location of Level Gauges, Field Displays, Tank Hubs,
System Hubs, Field Bus Modems, TankMaster etc.
Note
The information on this form is used for tagging signs, temperature sensor specification and wireless network information only. No
setting of device data base is done based on information on this data sheet.
Please state all distances in metric units.
Customer Information
Rosemount Tank Gauging system number:_______________________
Installation site: ____________________________________________
Total number of tanks: _______________________________________
Year and Month: ____________________________________________
End Customer:_____________________________________________
Contact Name: _____________________________________________
Telephone: ________________________________________________
P.O. Reference No:___________________________________________
Customer Signoff: ______________________________________________________________________________________________________
Email address: _________________________________________________________________________________________________________
System Overview
5400
2240S
5900S
5900S
2-in-1
2230
5900S
5400
5900C
3051S
2240S
775
2410
644
1420 Smart
Wireless
Gateway
Alternative Connection
to DCS/PLC/SCADA/Host
TankMaster
PC in Network
Alternative Connection
to DCS/PLC/SCADA/Host
2160
3308
3051S
644
Alarm
5300
ESD
2410
5900S Radar Level Gauge
(2-in-1 optional)
Still-pipe Array
Horn
5900C Radar Level Gauge
LPG/LNG
Still-pipe Array
Cone
2460
System Hub
2410
2410
2240S Multi-input
TemperatureTransmitter
2180 Field
Bus Modem
TankMaster.net
for Web Access
www
Alternative Connection
to DCS/PLC/SCADA/Host
2120/2130/2160
Liquid Level Switch
Smart Wireless
THUM Adapter
LPG/LNG
5400 Radar
Level
Transmitter
5300 Guided 3308 Wireless
Wave Radar Guided Wave Radar
Transmitter Transmitter
2410 Tank Hub
bolic
Parabolic
3051S Pressure
Transmitter
2230 Graphical
Field Display
565/566
765 Multiple Spot
Multiple Spot Temperature and
Temperature Water Level Sensor
Sensor
www.rosemount-tg.com
644 Temperature Transmitter with Single Point
Temperature Sensor
1
3
5
7
.
Fn
2
4
6
8
0
9
-
Field
Communicator
Rosemount Tank Gauging System
Tank Name
2
Antenna Type
Tank Product
Tank Height 5900 Radar
(mm)
Tag Name
February 2015
2410 Hub
Tag Name
2240 Temp 2230 Display
Tx Tag Name Tag Name
Note
Rosemount Tank Gauging System
February 2015
Tag/
Tank name
L0 Temp sensor length
include WLS (mm)
Position of temperature spot elements from sensor bottom end (mm)
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12
T13
T14
T15
T16
3
Rosemount Tank Gauging System
Multiple Spot Temperature Sensor with WLS
350 mm
350 mm
Multiple Spot Temperature Sensor
February 2015
Min. 1000 mm
Min. 1000 mm
Max Filling Level
Max Filling Level
T1
LW
LW
T1
T2
Highest temperature element <T16
T3
Min. 150 mm
L0
L
LT
Min. 500 mm
T2
T3
L0
L
LT
Highest temperature element <T16
Min. 500 mm
L= Distance from nozzle top to tank bottom
L= Distance from nozzle top to tank bottom
LW = Height of weight
LW = Height of weight
LT = Total length of temp sensor and WLS
LT = Total length of temp sensor and WLS
L0 = LT + 350 (mm)
L0 = LT + 350 (mm)
Where:
350 = Distance from top of sensor to lower thread (exact position of
flange can be adjusted up or down about 100 mm at installation using
the nuts and the 256 mm thread length)
Where:
350 = Distance from top of sensor to lower thread (exact position of
flange can be adjusted up or down about 100 mm at installation using
the nuts and the 256 mm thread length)
Lowest temp. spot (T1) 0,5 - 1,0 m above tank bottom, min 300 mm
from eye bolt in level sensor
Lowest temp. spot (T1) 0,5 - 1,0 m above tank bottom, min 300 mm
from eye bolt in level sensor
Highest temp. spot 0,5 - 1,0 m below max level, min 1000 mm from
top of sensor
Highest temp. spot 0,5 - 1,0 m below max level, min 1000 mm from
top of sensor
4
Rosemount Tank Gauging System
February 2015
Wireless Network Design (if included)
For complete help on preplanning of a Tank Gauging Wireless network see Reference Manual 300570EN. Tools to be used are a scaled sketch of the
installation site and AMS Wireless SNAP-ON Software.
Rule of 5 Found to be OK:
  Comments: _____________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
Rule of 3 Found to be OK:
  Comments:____________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
Rule of 25% Found to be OK:
  Comments:____________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
_____________________________________________________________________________________________________________________________________
Make a small sketch of the planned Wireless Network or send a copy of the SNAP-ON design picture
5
Rosemount Tank Gauging System
00806-0100-5100, Rev AA
System Configuration Data Sheet
February 2015
Rosemount Tank Gauging World Headquarters
Emerson Process Management
Box 130 45
SE-402 51 Gothenburg
SWEDEN
+46 31 337 00 00
+46 31 25 30 22
[email protected]
Rosemount Tank Gauging North America Inc.
Emerson Process Management
6005 Rogerdale Road
Mail Stop NC 136
77072 Texas, Houston, USA
+1 281 988 4000
+1 800 722 2865
[email protected]
Latin America Regional Office
Emerson Process Management
1300 Concord Terrace, Suite 400
Sunrise, Florida, 33323, USA
+1 954 846 5030
+1 954 846 5121
[email protected]
Asia Pacific Regional Office
Emerson Process Management Asia Pacific Pte Ltd
1 Pandan Crescent
Singapore 128461
+65 6777 8211
+65 6777 0947
[email protected]
Rosemount Tank Gauging Middle East & Africa.
Emerson Process Management
P. O Box 20048
Manama, Bahrain
+973 1722 6610
+973 1722 7771
[email protected]
The Emerson logo is a trademark and service mark of Emerson Electric Co.
Rosemount and Rosemount logotype are registered trademarks of Rosemount Inc.
All other marks are the property of their respective owners.
© 2015 Rosemount Tank Radar AB all rights reserved.