English

Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Rosemount 753R Web Based Monitoring
Indicator
• Complete web based monitoring solution from
measurement to a secure user interface via
iTraX® located on Rosemount.com
• Automate your manual monitoring
applications such as inventory management
• Scalable and flexible design platform enables
easy and cost effective installation practices
• Standard HART® interface for simple
integration
Product Discontinued February 2010
Contents
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
Rosemount 753R With iTraX® Configuration Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
www.rosemount.com
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Minimize Risk. Maximize Business Performance.
Remote Inventory Monitoring
•
Monitor inventory levels
24 hours a day via the
web
•
Supports Rosemount
HART® measurement
instrumentation
•
Fully integrated hardware
solution available with the
Rosemount 3051S
Minimize Risk
Maximize Business Performance
•
Eliminate costly tank outages at customer
sites
•
Eliminate unneeded truck deliveries
for partial fill
•
Mitigate installation and incompatibility risk
with a fully integrated and truly wireless
solution
•
Automated monitoring to support just-in-time
inventory and deliveries
•
•
Standardize operations on a single innovative
solution platform
Improve production planning to anticipate
customer demand
•
•
Depend on the reliability and support from the
global automation industry leader
Increase efficiency and productivity for an
improved bottom line
•
•
Best-in-class measurement performance,
quality, and reliability
Cost effectively monitor your inventory with
readings and often as every 15 minutes
Rosemount 753R
with iTraX® Benefits
Typical
Monitoring Risks
Simple
Installation
Data Reliability
Improved
Planning
Hardware
Integration
Technology
Platforms
Rosemount 753R
with iTraX®
Typical
Monitoring Benefits
Increased
Productivity
Automated
Monitoring
2
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
ITRAX WEB INTERFACE
Scalable and Flexible
•
Global implementation with a single platform
•
Any remote measurement monitoring need
•
Secure and user-friendly interface via
standard internet browser
•
Automated iTraX®-to-customer database
transfer into user ERP system (optional)
Full Functionality
•
Remote device configuration
•
Complete data historian
•
Advanced measurement monitoring
•
Alert notifications via email or pager
•
Customer-managed accounts
Secure Interface
Centralized server at Tier 1 facility:
•
Redundant network and facility
•
State of the art encryption and authentication
•
Data backup and recovery capabilities
•
iTraX® Server with uninterruptible power
supply (UPS) backup
•
Secure login
3
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Rosemount 753R Features
•
GSM/GPRS
•
3 line LCD display
•
Broad multi-provider network coverage
•
Scheduled and event driven transmissions
•
Modular and scalable hardware architecture
•
•
Built-in system diagnostic capabilities
Store and forward data logging for up to 400
readings
753R REMOTE MOUNT
Figure 1. 753R Remote Mount with Remote Power
Supply
Figure 2. 753R Remote Mount with 6-24 Vdc Line
Power
753R WITH INTEGRATED PRESSURE TRANSMITTER
Figure 3. 753R with Integrated Pressure Transmitter and Figure 4. 753R with Integrated Pressure Transmitter
Remote Power Supply
and 6-24 Vdc Line Power
4
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Specifications
FUNCTIONAL SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Power Supply
Electrical Connections
External Power Supply (Power Source Option S0)
Voltage = 6 to 24 Vdc
Power = 1.5 watts max
Remote Power Supply (Power Source Option S1)
Rosemount Remote Power Supply with solar panel and
battery (advanced power management for up to 5 years
battery life)
½ - 14 NPT conduit
Paint
Polyurethane
Cover O-rings
Buna-N
Shipping Weights
Temperature Limits
Ambient
-4 to 140 °F (-20 to 60 °C)
Storage
-40 to 185 °F (-40 to 85 °C)
Humidity Limits
0-100% relative humidity
Vibration
Suitable for 60-2000 Hz 2g as specified in IEC 60770-1
Table Wireless-1. Transmitter Weights without
Options
Transmitter Package
Add Weight In lb (kg)
753R Housing and RPS
(see Figure 1 on page 4)
753R Housing only
(see Figure 2 on page 4)
753R Housing, RPS, and Integrated
Pressure Transmitter
(see Figure 3 on page 4)
753R and Integrated Pressure
Transmitter
(see Figure 4 on page 4)
5.8 (2.63)
3.6 (1.63)
8.9 (4.04)
6.7 (3.04)
The Rosemount 753R Web Based Monitoring Indicator relies on third party cellular network
service for communications. The Rosemount 753R Web Based Monitoring Indicator may not
function properly during cellular network service failures.
Use of this device in control loops could result in death or serious injury.
The Rosemount 753R Web Based Monitoring Indicator is designed for monitoring use only.
Do not use for control or feedback applications.
Please consult the Rosemount 753R Web Based Monitoring Indicator Product Manual for
important additional information concerning the proper installation and use of this product.
5
Product Data Sheet
Rosemount 753R Indicator
Product Certifications
NOTE
The Rosemount 753R is intended for monitoring purposes only.
The Rosemount 753R is intended for web based monitoring applications
and is not designed to integrate into process control systems.
Approved Manufacturing Locations
Rosemount Inc. — Chanhassen, Minnesota USA
Telecommunication/EMC Compliance
FCC ID: IHDT56DB/IC ID: 109O-DB1 is contained within.
This device has met the applicable requirements of the R&TTE Directive.
This device has met the applicable requirements of the EMC Directive
2004/108/EC
Ordinary Locations Certifications for FM
As standard, the transmitter has been examined and tested to determine
that the design meets basic electrical, mechanical, and fire protection
requirements by FM, a nationally recognized testing laboratory (NRTL) as
accredited by the Federal Occupational Safety and Health Administration
(OSHA).
Hazardous Locations Certifications
USA and Canadian Certifications
Factory Mutual (FM) Approvals
N5
FM Class I, Division 2
USA Certificate Number: 3023264
Canadian Certificate Number: 3027229C
Class I, Division 2, Groups A, B, C, and D;
Temperature Class T4 Ta = 70 °C
Enclosure Type 3R
Note: To maintain a Type 3R enclosure, the solar panel
must be pointed upwards.
WARNING
Substitution of components may impair suitability for Division 2.
Explosion Hazard. Do not disconnect equipment when a flammable or
combustible atmosphere is present.
Explosion Hazard. Do not open enclosure or replace battery when
flammable or combustible atmosphere is present.
AVERTISMENT
La substitution des composants peut alterer la convenance a Division 2.
Risque d’explosion. Ne debranchez pas l’equipment quand une atmosphere
inflammable ou combustible est presente.
Risque d’explosion. N’ouvrez pas la cloture ou ne remplacez pas la batterie
quand l’atmosphere inflammable ou combustible est presente.
6
00813-0100-4379, Rev BA
March 2008
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Dimensional Drawings
Rosemount 753R with Integrated Coplanar Pressure Transmitter Manifold
Note
Dimensions are in inches (millimeters)
7
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Rosemount 753R with Integrated Coplanar Pressure Transmitter Manifold and Remote
Power Supply
Note
Dimensions are in inches (millimeters)
9.86
(53.24)
7.06
(179)
5.01
(127)
6.93
(176)
4.20
(170)
5.72
(145)
4.20
(107)
6.93
(176)
POSSIBLE ANTENNA ROTATION SHOWN
3.14
(80)
.85
(21.6)
.30
(7.625)
8.95
(227)
Rosemount 753R with a Coplanar Mounting Bracket
Note
Dimensions are in inches (millimeters)
90
POSSIBLE ANTENNA ROTATION SHOWN
.85
(21.6)
.30
(7.625)
6.93
(176)
6.15
(156)
2.81
(71)
4.70
(120)
8
7.74
(197)
3.54
(90)
6.25
(158)
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Rosemount 753R - Remote Power Supply
Note
Dimensions are in inches (millimeters)
9.86
(53.24)
2.58
(65.53)
90
7.06
(179)
12.43
(315.72)
5.01
(127)
4.20
(107)
.85
(21.6)
6.15
(156)
6.93
(176)
6.93
(176)
3.14
(80)
.30
(7.625)
U-BOLT BRACKET
2.81
(71)
3.08
(78)
4.72
(120)
6.90
(175)
6.24
(158)
Rosemount 753R Remote Power Supply In-Line Mounting Configuration
Note
Dimensions are in inches (millimeters)
90
7.06
(179)
5.01
(127)
6.93
(176)
6.93
(176)
5.72
(145)
.85
(21.6)
3.14
(80)
.30
(7.625)
6.15
(156)
U-BOLT BRACKET
2.81
(71)
3.08
(78)
4.72
(120)
6.90
(175)
6.24
(158)
6.90
(175)
9
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Ordering Information
Model
Product Description
753R
Web Based Monitoring Indicator
Code
Communications
G
Code
0
1
2
GSM/GPRS Wireless To iTraX®
Assembly Configuration
Assemble to a Rosemount 3051S Pressure Transmitter
Remote Mounted Housing Assembly
Assemble to a Rosemount 3051S Pressure Transmitter and a Remote Mounted Sensor(1)(2)
Code
Measurement Point Protocol
H0
4-20mA/HART Transmitter Input
Code
1A
Code
S0AA
S1AA(3)
Code
01
02
03
04
05
06
Code
Y1
M5(4)
N5
Housing Style
Material
Conduit Entry Size
PlantWeb Housing
Aluminum
1
/2-14 NPT
Power Source
No Power Accessories (Local Line Power 6-24 Vdc)
Solar Panel and Battery (Size: 1.5W)
Final Destination of Product (Communications Approval)
USA
Canada
Mexico
Spain
Brazil
Argentina(1)
Other Options
Discrete I/O
Discrete I/O (1 Dry Contact) (Consult factory for availability)
Meters
PlantWeb LCD Display
Product Certifications
FM Class I, Division 2 for U.S.A. and Canada
Typical Model Number: 753R G 1 H0 1A S1AA 01 M5
(1)
(2)
(3)
(4)
Consult factory for availability
Only available with Final Destination Code 01 USA
Required for Final Destination Code 04 Spain, 05 Brazil, and 06 Argentina
Required on all units
ITRAX® TRANSMISSION ORDERING INFORMATION
Note: Required with each Rosemount 753R Web Based Monitoring Indicator
Description
Invoice Interval
Part Number
4 readings, 1 transmission per day, 1 Alarm allowance per day
Monthly
00753-9100-0112
12 readings, 3 transmission per day, 1 Alarm allowance per day
Monthly
00753-9100-0312
48 readings, 12 transmission per day, 2 Alarm allowances per day
Monthly
00753-9100-1212
96 readings, 24 transmission per day, 2 Alarm allowances per day
Monthly
00753-9100-2412
10
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Rosemount 753R With iTraX® Configuration Data Sheet
BOLD = Required Value
★
= Default
Select only one of the items provided
One or more of the listed items can be selected
Sales Order No. ______________________
Unit No. _____________________________
For Factory Use Only
Line No. ____________________________
Configuration Information
Customer: _____________________________________________
New iTraX® Account: Yes No
Model No.: _____________________________________________
Master iTraX® Username: _________________________________
(Maximum of 25 Alpha-Numeric Characters)
iTraX®
P.O. No.:_______________________________________________
Master
Password: __________________________________
Line Item: ______________________________________________
(Password required for new iTraX® account only)
(Maximum of 12 Alpha-Numeric Characters)
753R / iTraX® Information
Device Tag Name:
__________________________________________
(20 characters maximum)
Measurement Variables to Transmit:
Read/Transmit Interval:
Sensor 1
PV
SV
TV
QV
Sensor 1
Read every 15 minutes / transmit every 1 hour (24/day)
Read every 30 minutes / transmit every 2 hours (12/day)
Read every 2 hours / transmit every 8 hours (3/day)
Read every 6 hours / transmit every 24 hours (1/day)
Turn-on Time:
Button Event Time-out:
Power Mode:
_______ seconds (default 15 seconds or 2 seconds for integral Rosemount 3051S)
_______ minutes (default 30 minutes)
Normal (power-saving sleep mode)★
Always On(1)
Heart Beat Monitoring
Yes
No★
(1) Local power S0AA option required.
Notification E-mail Configuration
E-mail Addresses for Alerts:
Maintenance
Operations/Dispatch
General
__________________________
__________________________
__________________________
11
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Alert Configuration
Alert 1
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 2
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 3
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 4
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 5
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
12
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Alert 6
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 7
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 8
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 9
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Alert 10
Alert Mode:
Alert Name:
Variable Assign:
Direction:
Unit of Measure:
Set Point:
Dead Band:
Alert Subject:
Alert Message:
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Enable
Disable
_____________________________________
PV
SV
TV
QV
Rising
Falling
_____________________________________
_____________________________________
_____________________________________
_____________________________________
_____________________________________
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
Units of Measurement
Example 1: Rising Alert
Alert “OFF”
Alert “ON”
Alert “OFF”
Alert Set Point
Deadband
Measurement Value
Time
Units of Measurement
Example 2: Falling Alert
Alert “OFF”
Alert “ON”
Alert “OFF”
Measurement Value
Alert Set Point
Deadband
Time
Discrete Output Configuration
Mode (choose 1):
Trigger Alert Name:
Direction:
Enable(1)
Disable (default)
_________________________ (must match an Alert Name from alert configurations on page 12)
Low > High
High > Low
(1) Requires Y1 option
Application Information (If Applicable)
Location (city, state, country):
Process Material Name:
Material Phase:
_____________________________________________
_____________________________________________
Liquid
Gas
Solid
Steam
Expected Date of Installation: _________
13
Product Data Sheet
Rosemount 753R Indicator
14
00813-0100-4379, Rev BA
March 2008
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
15
Product Data Sheet
00813-0100-4379, Rev BA
March 2008
Rosemount 753R Indicator
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.
All other marks are the property of their respective owners.
Standard terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale
Emerson Process Management
Rosemount Division
8200 Market Boulevard
Chanhassen, MN 55317 USA
T (U.S.) 1-800-999-9307
T (International) (952) 906-8888
F (952) 949-7001
Emerson Process Management
Heath Place
Bognor Regis
West Sussex PO22 9SH
England
T 44 (1243) 863 121
F 44 (1243) 867 554
www.rosemount.com
¢00813-XXXX-XXXXm¤
© 2008 Rosemount Inc. All rights reserved.
Emerson Process Management Asia
Pacific Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947
[email protected]