Rosemount 3095 MultiVariable™ with MODBUS Protocol Configuration Data Sheet 00806-0100-4738, Rev AA June 2013 Configuration Data Sheet ROSEMOUNT 3095FB ★ = Default P r oduc tDi s c ont i nue d Information Customer: Contact Name: Customer Phone: Customer Fax: Customer Approval Sign-Off: Customer PO: Model No (1) SST Tag: Transmitter Information (optional) Software Tag: Descriptor: Message: ___ ___ ___ ___ ___ ___ ___ ___ (8 characters) ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ (16 characters) ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ (32 characters) Date: Day __ __ (numeric) Month __ __ (numeric) Year __ __ (numeric) Transmitter Information Transmitter Address ___________________ (Range 1★ – 247) 1 Baud Rate (Select one) 1200 2400 4800 9600 ★ Process Temperature Setup Temperature mode options: Normal - The transmitter will report the measured RTD temperature value. Fixed/Backup - The transmitter reports the Fixed/Backup temperature value if the RTD fails or in the absence of an RTD measurement Enter a value to be used for Backup (RTD Failure) or Fixed (No RTD): Fixed/Backup Temperature _____________________ (Units are selected in the “Outputs” section below) Outputs Units: Differential Pressure: Static Pressure: inH2O @ 60°F (Inches of Water @ 60°F)★ PA (Pascals) PSI (Pounds per square inch)★ Process Temperature: °Fahrenheit ★ kPa (Kilopascals) inH2O @ 68 °F kPa (Kilopascals) MPa (Megapascals) °Celsius Lower (LTV) Upper (UTV) Default Values Differential Pressure: ______________________ ______________________ LRL, URL ★ Static Pressure: ______________________ ______________________ atmosphere, URL (absolute) ★ Process Temperature: ______________________ ______________________ 0, URL (gage) ★, LRL, URL ★ Trim Value www.rosemount.com Rosemount 3095 MultiVariable™ with MODBUS Protocol ★ = Default Configuration Data Sheet 00806-0100-4738, Rev AA June 2013 P r oduc tDi s c ont i nue d Lower Upper Default Values Differential Pressure: ______________________ ______________________ 0, URL ★ Static Pressure: ______________________ ______________________ 0, URL ★ Process Temperature: ______________________ ______________________ LRL, URL ★ Operation Limit Lower and upper operating limits must be within the minimum and maximum range limits as stated in the Range Limits Table (see page 3). (1) A complete model number is required before Rosemount Inc. can process the order. ★ = Default Damping (in seconds) Differential Pressure: 0.108 (select one) 0.864 ★ 6.912 0.216 1.728 13.824 0.432 3.456 27.648 Static Pressure: 0.108 (select one) 0.864 ★ 6.912 0.216 1.728 13.824 0.432 3.456 27.648 Process Temperature: 0.108 (select one) 0.864 ★ 6.912 0.216 1.728 13.824 0.432 3.456 27.648 For Rosemount Use Only S.O.: CHAMP: LI DATE: ADMIN: 3095FB MultiVariable Transmitter with MODBUS Protocol Range Limits Range 2 DP Span Units inH2O psi Pa kPa MPa 2 min. 2.5 0.09016 621.606 0.62161 0.000622 max 250 9.0156 62160.6 62.1606 0.062161 Range 3 DP Span min. 10 0.36063 2486.42 2.48842 0.002488 max 1000 360.63 249089 249.089 .249089 Range 3 (AP) Range C (GP) Span min. 221.837 8 55158.1 55.1581 0.055158 max 22183.7 800 5515811 5515.81 5.51581 Range 4 (AP) Range D (GP) Span min. 1005.48 36.26 250004 250.004 0.250004 max 100548.5 3626. 25000400 25000.4 25.0004 Configuration Data Sheet 00806-0100-4738, Rev AA June 2013 ROSEMOUNT 3095FC ★ = Default Information Rosemount 3095 MultiVariable™ with MODBUS Protocol P r oduc tDi s c ont i nue d Customer: Contact Name: Customer Phone: Customer Fax: Customer Approval Sign-Off: Customer PO: Model No (1) Tag Information (optional) Wired Tag: ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ (5 lines of 17 characters) ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ Permanent ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ (3 lines of 25 characters): ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ Meter I.D. (10 characters) ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ Meter Description (30 ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ characters) ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ Transmitter Information U.S. ★ Engineering Units Differential Pressure: inH2O at 60 °F★ Static Pressure: psi ★ Process Temperature: °Fahrenheit ★ Flow Station Name (20 characters) Foot3 / hour ★ Metric kPa kPa °Celsius Meter3 / hour 3095FC (3095FC ★) ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ 1 Meter Address _______________ 1 ★ (1 – 255) 2 Group _______________ 2 ★ (1 – 255) 9600 Baud Rate _______________ (600, 1200, 2400, 4800, 9600 ★, 19.2K) (1) A complete model number is required before Rosemount Inc. can process the order. 3 Rosemount 3095 MultiVariable™ with MODBUS Protocol ★ = Default Meter Setup Pipe ID: Pipe Material: Configuration Data Sheet 00806-0100-4738, Rev AA June 2013 P r oduc tDi s c ont i nue d ________________ ( in / mm) at ________________ reference temperature ( °F / °C) Carbon Steel ★ SST Monel Orifice Plate ID: sa ________________ ( in / mm) at ________________ reference temperature °F / °C) Orifice Material: Carbon Steel Low Flow Cutoff: Averaging Technique: SST ★ Monel ________________ ( inH2O / kPa) Flow Dependent Linear ★ Flow Weighted Linear Flow Dependent Formulaic Flow Weighted Formulaic Choose desired characterization method and only enter values for that method. Detail Characterization Method (AGA8 1992) ★ N2 CO2 C1 C2 C3 nC4 iC4 nC5 iC5 C6 C7 C8 C9 C10 H2S H2O He O2 CO H2 Default Value ★ Nitrogen mole percent Carbon Dioxide mole percent Methane mole percent Ethane mole percent Propane mole percent n-Butane mole percent i-Butane mole percent n-Pentane mole percent i-Pentane mole percent Hexane Heptane Octane Nonane Decane Hydrogen Sulfide mole percent Water mole percent Helium Oxygen mole percent Carbon monoxide mole percent Hydrogen mole percent 1 _______________________ % 0 _______________________ % 96 _______________________ % 3 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % 0 _______________________ % Gross Characterization Method, Option Code 1 (AGA8 Gr-Hv-CO2) Specific Gravity Heating Value Units Basis CO2 Mole % H2 Mole % CO Mole % Auto Calculate Auto Calculate BTU/Lb Dry _________________ % _________________ % _________________ % Specific Value _________________ Specific Value _________________ BTU/CF Wet Gross Characterization Method, Option Code 2 (AGA8 Gr-CO2-N2) Specific Gravity Heating Value Units Basis N2 Mole % CO2 Mole % H2 Mole % CO Mole % 4 Auto Calculate Auto Calculate BTU/Lb Dry _________________ % _________________ % _________________ % _________________ % Specific Value _________________ Specific Value _________________ BTU/CF Wet 1 0 96 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Rosemount 3095 MultiVariable™ with MODBUS Protocol Configuration Data Sheet 00806-0100-4738, Rev AA June 2013 ★ = Default P r oduc tDi s c ont i nue d Pressure Tap Gauge ★ Upstream ★ Absolute Downstream Base Conditions Base Pressure: Base Temperature: 14.73 psi / 101.56 kPa ________________ (14.73 psi★/ 101.56 kPa) ________________ 60 °F / 15.56 °C (60 °F★ / 15.56 °C) 500 feet / 152.4 meters Elevation: ________________ (500 feet★ / 152.4 meters) Latitude: ________________ 35 degrees (35 degrees ★) 0.010268 Cp Viscosity: ________________ (0.010268 Cp ★) Sp Heat Ratio: ________________ 1.3 (1.3 ★) Atmospheric Pressure Calculate based on entered parameters 14.45 psi / 99.63 kPa Enter ★ ______________________ (14.45 psi ★/ 99.63 kPa) Flow Alarms Disable ★ Enable Low Alarm ______________________ (MCF/day / km3/day) High Alarm ______________________ (MCF/day / km3/day) PV Fault Values DP: Last Good Value ★ User-Specified Fault Value _____________ SP: Last Good Value ★ User-Specified Fault Value _____________ T: Last Good Value ★ User-Specified Fault Value _____________ History 0 Contract Hour: _____ _____ (0 – 23 integer) (0 = midnight ★) Logged Parameters (Select any number of variables. Selected parameters apply to both daily logs and variable logs.) ✔ Total Flow ★ □ □ Minimum Static Pressure □ Other: ____________ ✔ Total Flow Time ★ □ ✔ Average Process Temperature ★ □ □ Other: ____________ ✔ Total Energy ★ □ □ Average Heating Value □ Other: ____________ □ Average Flow Rate □ Average Compressibility Factor □ Other: ____________ □ Average Energy Rate □ Average Integral Value □ Other: ____________ ✔ Average Differential Pressure ★ □ ✔ Average C Prime or Integral Multiplier Value (IMV)★ □ □ Other: ____________ □ Maximum Differential Pressure □ Specific Gravity (Relative Density) □ Other: ____________ □ Minimum Differential Pressure □ Maximum Process Temperature □ Other: ____________ ✔ Average Static Pressure ★ □ □ Minimum Process Temperature □ Other: ____________ □ Maximum Static Pressure ✔ Uncorrected Flow Rate★ □ 5 Configuration Data Sheet 00806-0100-4738, Rev AA June 2013 P r oduc tDi s c ont i nue d LCD Display Information (Only enter if LCD meter ordered.) Display Parameters (Select any number of variables.) ✔ Flow Rate ★ □ □ Totalized Energy Yesterday □ Other: ________________ ✔ Differential Pressure ★ □ □ Mole Percent CO2 □ Other: ________________ □ Totalized Flow Today □ Mole Percent N2 □ Other: ________________ □ Totalized Flow Yesterday □ Orifice Bore at 68 °F □ Other: ________________ ✔ Static Pressure ★ □ ✔ Date and Time ★ □ □ Other: ________________ ✔ Temperature ★ □ □ Heating Value □ Other: ________________ ✔ Energy Flow Rate ★ □ □ Specific Gravity (Relative Density) □ Other: ________________ □ Totalized Energy Today Special Calibration (Optional) Default values indicate standard calibration. Enter lower trim and upper trim values if special calibration is desired: Lower (LTV) Upper (UTV) Default Values Differential Pressure: ______________________ ______________________ 0, URL ★ Static Pressure: ______________________ ______________________ 0, URL ★ Trim Value Process Temperature (fixed): –40 °F ★ 464 For Rosemount Use Only S.O.: CHAMP: LI DATE: ADMIN: 3095FC Flow Transmitter Range Units Differential Pressure Range 2 Span Units in H2O kPa in H2O(1) kPa(1) min 2.5 0.62161 10 2.48 max 250 62.1606 1000 248.64 Absolute Pressure Range 3 Span Units psia MPa min 150 0.05516 Absolute Pressure Range 4 Span max 800 5.51581 min 40 0.275791 max 4000 27.5790 (1) Range 3. Standard Terms and Conditions of Sale can be found at www.rosemount.com/terms_of_sale The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount, Annubar, ProPlate, and the Rosemount logotype are registered trademarks of Rosemount Inc. Engineering Assistant is a registered trademark of AMS Suite. Emerson Process Management Rosemount Measurement 8200 Market Boulevard Chanhassen MN 55317 USA Tel (USA) 1 800 999 9307 Tel (International) +1 952 906 8888 Fax +1 952 949 7001 Emerson Process Management Rosemount Measurement 1300 Concord Terrace, Suite 400 Sunrise Florida 33323 USA Tel + 1 954 846 5030 00806-0100-4738 Rev AA, 6/13 Emerson Process Management Blegistrasse 23 P.O. Box 1046 CH 6341 Baar Switzerland Tel +41 (0) 41 768 6111 Fax +41 (0) 41 768 6300 Emerson FZE P.O. Box 17033 Jebel Ali Free Zone Dubai UAE Tel +971 4 811 8100 Fax +971 4 886 5465 Emerson Process Management Asia Pacific Pte Ltd 1 Pandan Crescent Singapore 128461 Tel +65 6777 8211 Fax +65 6777 0947 Service Support Hot line: +65 6770 8711 Email : [email protected]
© Copyright 2026 Paperzz