+ Red - Black RS 485A White RS 485B Green Element No. Color codes WLS-MODBUS TRANSMITTER Common return RTD 1 brown RTD 2 red RTD 3 orange RTD 4 yellow RTD 5 green RTD 6 blue RTD 7 violet RTD 8 grey RTD 9 white RTD 10 pink RTD 11 brown/black RTD 12 red/black RTD 13 orange/black RTD 14 yellow/black RTD 15 green/black RTD 16 blue/black RTD 17 violet/black RTD 18 grey/black RTD 19 white/black RTD 20 pink/black Max No.of elements HAZARDOUS (Classified) LOCATION Class I, Div.1, Group A, B, C, D or Class I, zone 0, AEx ia IIC; Temperature Class T4;-50≤ TA≤ 120°C Temperature Class T6;-50≤ TA≤ 70°C Common return 1" hose 20 3/4" hose 13 Black conductors from common point. Common return always have 2 common Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Max length 3m. + - Note 1. RS485A RS485B Transmitter cable Note 1. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. + RS485A RS485B Multiple or single-element temperature sensor Common Return RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD HAZARDOUS LOCATION / UNCLASSIFIED LOCATION. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Max length 100m. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt ≤ 7.2V Po ≤ 700mW It ≤ 250mA La ≥ 130µH + Lcable Ca ≥ 0µF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Common return. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note2: For installations in the US the associated barriers or galvanic isolators shall be FM Approved. For installations in Canada the associated barriers or galvanic isolators shall be cFM or CSA listed. In both cases the manufacturers installation drawings shall be followed when installing the equipment. Po of the barrier must be less than or equal to the Pi of the apparatus and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. a.The unclassified location apparatus connected to the associated apparatus shall not generate more than the quoted Um of the Associated Apparatus. b.For installations in the US the associated intrinsically safe barriers shall have an appropriate FM Approval. For installations in Canada the associated apparatus shall have an appropriate cFM or CSA Approval. The manufacturers control drawing shall be followed when installing this equipment. c.Installations shall be in accordance with ANSI/ISA RP12.06.01 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Location” and the National Electrical Code ANSI/NFPA 70. Installation in Canada shall be in accordance with the Canadian Electrical Code C22.1 d.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Voc or Vt equal or less than Ui Isc or It equal or less than Ii Po equal or less than Pi La equal to or greater than Lcable + Li Ca equal to or greater than Ccable + Ci e.The associated apparatus shall be of like polarity. f.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. g.The Entity Concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of Voc (or Uo) and Isc (or Io) for the associated apparatus are less than or equal to Ui and Ii for the intrinsically safe apparatus and the approved values of Ca(Co) and La(Lo) for the associated apparatus are greater than Ci + Ccable and Li + Lcable, respectively, for the intrinsically safe apparatus. h.WARNING: Substitution of components may impair intrinsic safety and suitability for Division1/Zone 0 hazardous (classified) Locations. ADVERTISEMENT: La substitution de composants peut compromettre la sécurité intrinsèque. i.Um=250V Drawing Number: Item Description: CONTROL DRAWING for US and Canada 800-9020-FM For hazardous location installation of WLS MODBUS Application: Rev.: 10 First angle projection Scale: Department: Senmatic Instruction No.: 1:1 Industrivej 8 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 1 of 18 + Red - Black RS 485A White RS 485B Green HAZARDOUS (Classified) LOCATION Class I, Div.1, Group A, B, C, D or Class I, zone 0, AEx ia IIC; Temperature Class T4;-50≤ TA≤ 120°C Temperature Class T6;-50≤ TA≤ 70°C WLS-MODBUS TRANSMITTER Element No. RTD 1 Color codes 3 wire brown-black,black RTD 2 red-black,black RTD 3 orange-black,black RTD 4 yellow-black,black RTD 5 green-black,black RTD 6 blue-black,black RTD 7 violet-black,black RTD 8 grey-black,black RTD 9 white-black,black RTD 10 pink-black,black RTD 11 brown,brown-black RTD 12 red,red-black RTD 13 orange,orange-black RTD 14 yellow,yellow-black RTD 15 green,green-black RTD 16 blue,blue-black RTD 17 violet,violet-black RTD 18 grey,grey-black RTD 19 white,white-black RTD 20 pink,pink-black Max No.of elements 3 wire 1" hose 20 3/4" hose 13 Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Note 1. HAZARDOUS LOCATION / UNCLASSIFIED LOCATION. + - Max length 3m. RS485B RS485B Max length 100m. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 250mA ≥ 130µH + Lcable ≥ 0µF + Ccable Transmitter cable Multiple or single-element temperature sensor 3 wire RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD ASSOCIATED APPARATUS WITH ENTITY PARAMETERS RS485A RS485A Note 1. + - 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure Note 2. For installations in the US the associated barriers or galvanic isolators shall be FM Approved. For installations in Canada the associated barriers or galvanic isolators shall be cFM or CSA listed. In both cases the manufacturers installation drawings shall be followed when installing the equipment. Po of the barrier must be less than or equal to the Pi of the apparatus and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. a.The unclassified location apparatus connected to the associated apparatus shall not generate more than the quoted Um of the Associated Apparatus. b.For installations in the US the associated intrinsically safe barriers shall have an appropriate FM Approval. For installations in Canada the associated apparatus shall have an appropriate cFM or CSA Approval. The manufacturers control drawing shall be followed when installing this equipment. c.Installations shall be in accordance with ANSI/ISA RP12.06.01 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Location” and the National Electrical Code ANSI/NFPA 70. Installation in Canada shall be in accordance with the Canadian Electrical Code C22.1 d.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Voc or Vt equal or less than Ui Isc or It equal or less than Ii Po equal or less than Pi La equal to or greater than Lcable + Li Ca equal to or greater than Ccable + Ci e.The associated apparatus shall be of like polarity. f.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. g.The Entity Concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of Voc (or Uo) and Isc (or Io) for the associated apparatus are less than or equal to Ui and Ii for the intrinsically safe apparatus and the approved values of Ca(Co) and La(Lo) for the associated apparatus are greater than Ci + Ccable and Li + Lcable, respectively, for the intrinsically safe apparatus. h.WARNING: Substitution of components may impair intrinsic safety and suitability for Division 1/Zone 0 hazardous (classified) Locations. ADVERTISEMENT: La substitution de composants peut compromettre la sécurité intrinsèque. i.Um=250V. Drawing Number: Item Description: CONTROL DRAWING for US and Canada 800-9020-FM For hazardous location installation of WLS MODBUS Application: Rev.: 10 First angle projection Scale: Department: Senmatic Instruction No.: 1:1 Industrivej 8 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 2 of 18 + Red - Black RS 485A White RS 485B Green HAZARDOUS (Classified) LOCATION Class I, Div.1, Group A, B, C, D or Class I, zone 0, AEx ia IIC; Temperature Class T4;-50≤ TA≤ 120°C Temperature Class T6;-50≤ TA≤ 70°C + - Max length 3m. Note 1. Transmitter cable WLS-MODBUS TRANSMITTER Insulation color codes Element No. 4 wire RTD 1 brown,brown-black,black RTD 2 red,red-black,black RTD 3 orange,orange-black,black RTD 4 yellow,yellow-black,black RTD 5 green,green-black,black RTD 6 blue,blue-black,black RTD 7 violet,violet-black,black RTD 8 grey,grey-black,black RTD 9 white,white-black,black RTD 10 pink,pink-black,black RTD 11 brown/black,brown/black-black,black red/black,red/black-black,black RTD 12 RTD 13 orange/black,orange/black-black,black RTD 14 yellow/black,yellow/black-black,black RTD 15 green/black,green/black-black,black RTD 16 Blue/black,Blue/black-black,black Max No.of elements 4wire 1" hose 16 3/4" hose 10 Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Note 1. HAZARDOUS LOCATION / UNCLASSIFIED LOCATION. RS485A RS485B Multiple or single-element temperature sensor RTD 1. 4 wire RTD 2. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF + - RS485A RS485B ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt ≤ 7.2V Po ≤ 700mW It ≤ 250mA La ≥ 130µH + Lcable Ca ≥ 0µF + Ccable Max length 100m. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. RTD 3. RTD 4. Vt Po It La Ca RTD 5. RTD 6. RTD 7. ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable RTD 8. RTD 9. RTD 10. RTD 11. RTD 12. RTD 13. RTD 14. RTD 15. RTD 16. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. For installations in the US the associated barriers or galvanic isolators shall be FM Approved. For installations in Canada the associated barriers or galvanic isolators shall be cFM or CSA listed. In both cases the manufacturers installation drawings shall be followed when installing the equipment. Po of the barrier must be less than or equal to the Pi of the apparatus and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. a.The unclassified location apparatus connected to the associated apparatus shall not generate more than the quoted Um of the Associated Apparatus. b.For installations in the US the associated intrinsically safe barriers shall have an appropriate FM Approval. For installations in Canada the associated apparatus shall have an appropriate cFM or CSA Approval. The manufacturers control drawing shall be followed when installing this equipment. c.Installations shall be in accordance with ANSI/ISA RP12.06.01 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Location” and the National Electrical Code ANSI/NFPA 70. Installation in Canada shall be in accordance with the Canadian Electrical Code C22.1 d.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Voc or Vt equal or less than Ui Isc or It equal or less than Ii Po equal or less than Pi La equal to or greater than Lcable + Li Ca equal to or greater than Ccable + Ci e.The associated apparatus shall be of like polarity. f.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. g.The Entity Concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of Voc (or Uo) and Isc (or Io) for the associated apparatus are less than or equal to Ui and Ii for the intrinsically safe apparatus and the approved values of Ca(Co) and La(Lo) for the associated apparatus are greater than Ci + Ccable and Li + Lcable, respectively, for the intrinsically safe apparatus. h.WARNING: Substitution of components may impair intrinsic safety and suitability for Division 1/Zone 0 hazardous (classified) Locations. ADVERTISEMENT: La substitution de composants peut compromettre la sécurité intrinsèque. i.Um=250V Drawing Number: Item Description: CONTROL DRAWING for US and Canada 800-9020-FM For hazardous location installation of WLS MODBUS Application: Rev.: 10 First angle projection Scale: Department: Senmatic Instruction No.: 1:1 Industrivej 8 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 3 of 18 + Red - Black RS 485A White RS 485B Green Element No. Color codes WLS-MODBUS TRANSMITTER Common return RTD 1 brown RTD 2 red RTD 3 orange RTD 4 yellow RTD 5 green RTD 6 blue RTD 7 violet RTD 8 grey RTD 9 white RTD 10 pink RTD 11 brown/black RTD 12 red/black RTD 13 orange/black RTD 14 yellow/black RTD 15 green/black RTD 16 blue/black RTD 17 violet/black RTD 18 grey/black RTD 19 white/black RTD 20 pink/black Max No.of elements Temperature class T4; -50≤ TA ≤120 C Temperature class T6; -50≤ TA ≤ 70 C Common return 1" hose 20 3/4" hose 13 Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Max length 3m. + - Note 1. RS485A RS485B Multiple or single-element temperature sensor Common Return Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF Black conductors from common point. Common return always have 2 common 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. + - ASSOCIATED APPARATUS WITH ENTITY PARAMETERS RS485A RS485B Transmitter cable Note 1. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Max length 100m. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 250mA ≥ 130µH + Lcable ≥ 0µF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Common return. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. For installations in Europe the associated apparatus shall have an appropriate EC-Type Examination certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for ATEX For hazardous location installation of WLS MODBUS Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 4 of 18 + Red - Black RS 485A White RS 485B Green Element No. RTD 1 Color codes 3 wire brown-black,black RTD 2 red-black,black RTD 3 orange-black,black RTD 4 yellow-black,black RTD 5 green-black,black RTD 6 blue-black,black RTD 7 violet-black,black RTD 8 grey-black,black RTD 9 white-black,black RTD 10 pink-black,black RTD 11 brown,brown-black RTD 12 red,red-black RTD 13 orange,orange-black RTD 14 yellow,yellow-black RTD 15 green,green-black RTD 16 blue,blue-black RTD 17 violet,violet-black RTD 18 grey,grey-black RTD 19 white,white-black RTD 20 pink,pink-black Max No.of elements 3 wire 1" hose 20 3/4" hose 13 Temperature class T4; -50≤ TA ≤120 C Temperature class T6; -50≤ TA ≤ 70 C Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Note 1. HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. + - Max length 3m. RS485B RS485B ≤ 7.2V ≤ 700mW ≤ 250mA ≥ 130µH + Lcable ≥ 0µF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Max length 100m. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF Vt Po It La Ca Transmitter cable Multiple or single-element temperature sensor 3 wire RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD + - RS485A RS485A Note 1. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. For installations in Europe the associated apparatus shall have an appropriate EC-Type Examination certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for ATEX For hazardous location installation of WLS MODBUS Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 5 of 18 + Red - Black RS 485A White RS 485B Green Temperature class T4; -50≤ TA ≤120 C Temperature class T6; -50≤ TA ≤ 70 C 4 wire RTD 1 brown,brown-black,black RTD 2 red,red-black,black RTD 3 orange,orange-black,black RTD 4 yellow,yellow-black,black RTD 5 green,green-black,black RTD 6 blue,blue-black,black RTD 7 violet,violet-black,black RTD 8 grey,grey-black,black RTD 9 white,white-black,black RTD 10 pink,pink-black,black RTD 11 brown/black,brown/black-black,black red/black,red/black-black,black RTD 12 RTD 13 orange/black,orange/black-black,black RTD 14 RTD 15 green/black,green/black-black,black Blue/black,Blue/black-black,black Max No.of elements Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF 16 3/4" hose 10 Max length 3m. + - ASSOCIATED APPARATUS WITH ENTITY PARAMETERS RS485A RS485A RS485B RS485B Transmitter cable Max length 100m. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 250mA ≥ 130µH + Lcable ≥ 0µF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. RTD 3. RTD 4. 4wire 1" hose Note 1. Note 1. Multiple or single-element temperature sensor RTD 1. 4 wire RTD 2. yellow/black,yellow/black-black,black RTD 16 + - WLS-MODBUS TRANSMITTER Insulation color codes Element No. HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. RTD 5. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF Vt Po It La Ca RTD 6. RTD 7. RTD 8. ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable RTD 9. RTD 10. RTD 11. RTD 12. RTD 13. RTD 14. RTD 15. RTD 16. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application,and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a.For installations in Europe the associated apparatus shall have an appropriate EC-Type Examination certificate. The manufacturers control drawing shall be followed when installing this equipment. b.Installations shall be in accordance with EN 60079-14 and local installation requirements. c.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d.The associated apparatus shall be of like polarity. e.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for ATEX For hazardous location installation of WLS MODBUS Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 6 of 18 + Red - Black RS 485A White RS 485B Green Element No. Color codes brown RTD 2 red RTD 3 orange RTD 4 yellow RTD 5 green RTD 6 blue RTD 7 violet RTD 8 grey RTD 9 white RTD 10 pink RTD 11 brown/black RTD 12 red/black RTD 13 orange/black RTD 14 yellow/black RTD 15 green/black RTD 16 blue/black RTD 17 violet/black RTD 18 grey/black RTD 19 white/black RTD 20 pink/black 1" hose WLS-MODBUS TRANSMITTER Common return RTD 1 Max No.of elements Temperature class T4; -50≤ TA ≤120 C Temperature class T6; -50≤ TA ≤ 70 C Common return 20 3/4" hose 13 black conductors from common point. Common return always have 2 common Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Max length 3m. + - Note 1. RS485A RS485B Multiple or single-element temperature sensor Common Return Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. + - ASSOCIATED APPARATUS WITH ENTITY PARAMETERS RS485A RS485B Transmitter cable Note 1. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Max length 100m. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 250mA ≥ 130µH + Lcable ≥ 0µF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Common return. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. The associated apparatus shall have an appropriate IECEx certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for IECEx For hazardous location installation of WLS MODBUS Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 7 of 18 + Red - Black RS 485A White RS 485B Green Temperature class T4; -50≤ TA ≤120 C Temperature class T6; -50≤ TA ≤ 70 C HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. WLS-MODBUS TRANSMITTER Element No. RTD 1 Color codes 3 wire brown-black,black RTD 2 red-black,black RTD 3 orange-black,black RTD 4 yellow-black,black RTD 5 green-black,black RTD 6 blue-black,black RTD 7 violet-black,black RTD 8 grey-black,black RTD 9 white-black,black RTD 10 pink-black,black RTD 11 brown,brown-black RTD 12 red,red-black RTD 13 orange,orange-black RTD 14 yellow,yellow-black RTD 15 green,green-black RTD 16 blue,blue-black RTD 17 violet,violet-black RTD 18 grey,grey-black RTD 19 white,white-black RTD 20 pink,pink-black Max No.of elements 3 wire 1" hose 20 3/4" hose 13 Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Note 1. Max length 3m. + - RS485A RS485A RS485B RS485B Note 1. ≤ 7.2V ≤ 700mW ≤ 250mA ≥ 130µH + Lcable ≥ 0µF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Max length 100m. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF Vt Po It La Ca Transmitter cable Multiple or single-element temperature sensor 3 wire RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD ASSOCIATED APPARATUS WITH ENTITY PARAMETERS + - 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. The associated apparatus shall have an appropriate IECEx certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for IECEx For hazardous location installation of WLS MODBUS Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 8 of 18 + Red - Black RS 485A White RS 485B Green Temperature class T4; -50≤ TA ≤120 C Temperature class T6; -50≤ TA ≤ 70 C Insulation color codes Element No. 4 wire RTD 1 brown,brown-black,black RTD 2 red,red-black,black RTD 3 orange,orange-black,black RTD 4 yellow,yellow-black,black RTD 5 green,green-black,black RTD 6 blue,blue-black,black RTD 7 violet,violet-black,black RTD 8 grey,grey-black,black RTD 9 white,white-black,black RTD 10 pink,pink-black,black RTD 11 brown/black,brown/black-black,black red/black,red/black-black,black RTD 12 RTD 13 orange/black,orange/black-black,black RTD 14 yellow/black,yellow/black-black,black RTD 15 green/black,green/black-black,black RTD 16 Blue/black,Blue/black-black,black Max No.of elements 4wire 1" hose 16 3/4" hose 10 WLS-MODBUS TRANSMITTER Ui=7.2V Pi=700mW Ii=250mA Li=130µH Ci=0µF Note 1. HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. Max length 3m. + - RS485A RS485B Note 1. Multiple or single-element temperature sensor RTD 1. 4 wire RTD 2. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS RS485A Transmitter cable Max length 100m. RS485B Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 250mA ≥ 130µH + Lcable ≥ 0µF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. RTD 3. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF + - Vt Po It La Ca RTD 4. RTD 5. RTD 6. ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable RTD 7. RTD 8. RTD 9. RTD 10. RTD 11. RTD 12. RTD 13. RTD 14. RTD 15. RTD 16. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. The associated apparatus shall have an appropriate IECEx certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for IECEx For hazardous location installation of WLS MODBUS Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 9 of 18 + Red - Black RS 485A White RS 485B Green Element No. Color codes brown RTD 2 red RTD 3 orange RTD 4 yellow RTD 5 green RTD 6 blue RTD 7 violet RTD 8 grey RTD 9 white RTD 10 pink RTD 11 brown/black RTD 12 red/black RTD 13 orange/black RTD 14 yellow/black RTD 15 green/black RTD 16 blue/black RTD 17 violet/black RTD 18 grey/black RTD 19 white/black RTD 20 pink/black Max No.of elements WLS-HART TRANSMITTER Common return RTD 1 Common return 1" hose 20 3/4" hose 13 Black conductors from common point. Common return always have 2 common HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. Temperature class T4; -50≤ TA ≤120 C Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF Note 1. + - + - Multiple or single-element temperature sensor Common Return Transmitter cable Note 1. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Max length 100m. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca ≤ 28V ≤ 700mW ≤ 100mA ≥ 2.5mH + Lcable ≥ 20nF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Common return. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. The associated apparatus shall have an appropriate IECEx certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following: Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for IECEx For hazardous location installation of WLS HART Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 10 of 18 + Red - Black RS 485A White RS 485B Green WLS-HART TRANSMITTER Element No. RTD 1 Color codes 3 wire brown-black,black RTD 2 red-black,black RTD 3 orange-black,black RTD 4 yellow-black,black RTD 5 green-black,black RTD 6 blue-black,black RTD 7 violet-black,black RTD 8 grey-black,black RTD 9 white-black,black RTD 10 pink-black,black RTD 11 brown,brown-black RTD 12 red,red-black RTD 13 orange,orange-black RTD 14 yellow,yellow-black RTD 15 green,green-black RTD 16 blue,blue-black RTD 17 violet,violet-black RTD 18 grey,grey-black RTD 19 white,white-black RTD 20 pink,pink-black Max No.of elements 3 wire 1" hose 20 3/4" hose 13 HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. Temperature class T4; -50≤ TA ≤120 C Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF Note 1. + - + ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca Transmitter cable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Multiple or single-element temperature sensor 3 wire Note 1. Ii=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD ≤ 28V ≤ 700mW ≤ 100mA ≥ 2.5mH + Lcable ≥ 20nF + Ccable Max length 100m. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. The associated apparatus shall have an appropriate IECEx certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for IECEx For hazardous location installation of WLS HART Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 11 of 18 + Red - Black RS 485A White RS 485B Green Element No. 4 wire Insulation color codes RTD 1 brown,brown-black,black RTD 2 red,red-black,black RTD 3 orange,orange-black,black RTD 4 yellow,yellow-black,black RTD 5 green,green-black,black RTD 6 blue,blue-black,black RTD 7 violet,violet-black,black RTD 8 grey,grey-black,black RTD 9 white,white-black,black RTD 10 pink,pink-black,black RTD 11 brown/black,brown/black-black,black red/black,red/black-black,black RTD 12 RTD 13 orange/black,orange/black-black,black RTD 14 yellow/black,yellow/black-black,black RTD 15 green/black,green/black-black,black RTD 16 Blue/black,Blue/black-black,black Max No.of elements HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. Temperature class T4; -50≤ TA ≤120 C WLS-HART TRANSMITTER Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF Note 1. Multiple or single-element temperature sensor RTD 1. 4 wire RTD 2. 16 3/4" hose 10 + - ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca Transmitter cable Max length 100m. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca RTD 4. RTD 5. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF ≤ 28V ≤ 700mW ≤ 100mA ≥ 2.5mH + Lcable ≥ 20nF + Ccable The paramenters apply for the total of all elements. RTD 3. 4wire 1" hose Note 1. + - RTD 6. ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable RTD 7. RTD 8. RTD 9. RTD 10. RTD 11. RTD 12. RTD 13. RTD 14. RTD 15. RTD 16. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. The associated apparatus shall have an appropriate IECEx certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for IECEx For hazardous location installation of WLS HART Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 12 of 18 + Red - Black RS 485A White RS 485B Green Element No. Color codes brown RTD 2 red RTD 3 orange RTD 4 yellow RTD 5 green RTD 6 blue RTD 7 violet RTD 8 grey RTD 9 white RTD 10 pink RTD 11 brown/black RTD 12 red/black RTD 13 orange/black RTD 14 yellow/black RTD 15 green/black RTD 16 blue/black RTD 17 violet/black RTD 18 grey/black RTD 19 white/black RTD 20 pink/black Max No.of elements WLS-HART TRANSMITTER Common return RTD 1 Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF Note 1. 20 3/4" hose 13 + - + - Multiple or single-element temperature sensor Common Return Transmitter cable Note 1. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF Common return 1" hose HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. Temperature class T4; -50≤ TA ≤120 C Black conductors from common point. Common return always have 2 common. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Max length 100m. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca ≤ 28V ≤ 700mW ≤ 100mA ≥ 2.5mH + Lcable ≥ 20nF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Common return. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. For installations in Europe the associated apparatus shall have an appropriate EC-Type Examination certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for ATEX For hazardous location installation of WLS HART Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Page 13 of 18 Sheet format: A3 + Red - Black RS 485A White RS 485B Green WLS-HART TRANSMITTER Element No. RTD 1 Color codes 3 wire brown-black,black RTD 2 red-black,black RTD 3 orange-black,black RTD 4 yellow-black,black RTD 5 green-black,black RTD 6 blue-black,black RTD 7 violet-black,black RTD 8 grey-black,black RTD 9 white-black,black RTD 10 pink-black,black RTD 11 brown,brown-black RTD 12 red,red-black RTD 13 orange,orange-black RTD 14 yellow,yellow-black RTD 15 green,green-black RTD 16 blue,blue-black RTD 17 violet,violet-black RTD 18 grey,grey-black RTD 19 white,white-black RTD 20 pink,pink-black Max No.of elements 3 wire 1" hose 20 3/4" hose 13 HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. Temperature class T4; -50≤ TA ≤120 C Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF Note 1. + - + ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt ≤ 28V Po ≤ 700mW It ≤ 100mA La ≥ 2.5mH + Lcable Ca ≥ 20nF + Ccable Transmitter cable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Multiple or single-element temperature sensor 3 wire Note 1. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD Max length 100m. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a. For installations in Europe the associated apparatus shall have an appropriate EC-Type Examination certificate. The manufacturers control drawing shall be followed when installing this equipment. b. Installations shall be in accordance with EN 60079-14 and local installation requirements. c. The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d. The associated apparatus shall be of like polarity. e. The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for ATEX For hazardous location installation of WLS HART Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Page 14 of 18 Sheet format: A3 + Red - Black RS 485A White RS 485B Green 4 wire RTD 1 brown,brown-black,black RTD 2 red,red-black,black RTD 3 orange,orange-black,black RTD 4 yellow,yellow-black,black RTD 5 green,green-black,black RTD 6 blue,blue-black,black RTD 7 violet,violet-black,black RTD 8 grey,grey-black,black RTD 9 white,white-black,black RTD 10 pink,pink-black,black RTD 11 brown/black,brown/black-black,black red/black,red/black-black,black RTD 12 RTD 13 WLS-HART TRANSMITTER Insulation color codes Element No. orange/black,orange/black-black,black RTD 14 Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF RTD 15 green/black,green/black-black,black Blue/black,Blue/black-black,black 16 3/4" hose 10 + - ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca Transmitter cable Max length 100m. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca RTD 4. RTD 5. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF ≤ 28V ≤ 700mW ≤ 100mA ≥ 2.5mH + Lcable ≥ 20nF + Ccable The paramenters apply for the total of all elements. RTD 3. 4wire 1" hose Note 1. + - Note 1. Multiple or single-element temperature sensor RTD 1. 4 wire RTD 2. yellow/black,yellow/black-black,black RTD 16 Max No.of elements HAZARDOUS LOCATION / NON-HAZARDOUS LOCATION. Temperature class T4; -50≤ TA ≤120 C RTD 6. ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable RTD 7. RTD 8. RTD 9. RTD 10. RTD 11. RTD 12. RTD 13. RTD 14. RTD 15. RTD 16. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. Selected barriers must be third party certified as providing intrinsically safe circuits for the application, and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. Po of the barrier must be less than or equal to the Pi of the intrinsically safe equipment. a.For installations in Europe the associated apparatus shall have an appropriate EC-Type Examination certificate. The manufacturers control drawing shall be followed when installing this equipment. b.Installations shall be in accordance with EN 60079-14 and local installation requirements. c.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Uo equal or less than Ui Io equal or less than Ii Po equal or less than Pi Lo equal to or greater than Lcable + Li Co equal to or greater than Ccable + Ci d.The associated apparatus shall be of like polarity. e.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. Item Description: CONTROL DRAWING for ATEX For hazardous location installation of WLS HART Drawing Number: 800-9020-FM Rev.: 10 Application: First angle projection Scale: Department: Senmatic Instruction No.: Industrivej 8 1:1 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 15 of 18 + Red - Black RS 485A White RS 485B Green Element No. Color codes WLS-HART TRANSMITTER Common return RTD 1 brown RTD 2 red RTD 3 orange RTD 4 yellow RTD 5 green RTD 6 blue RTD 7 violet RTD 8 grey RTD 9 white RTD 10 pink RTD 11 brown/black RTD 12 red/black RTD 13 orange/black RTD 14 yellow/black RTD 15 green/black RTD 16 blue/black RTD 17 violet/black RTD 18 grey/black RTD 19 white/black RTD 20 pink/black Max No.of elements HAZARDOUS (Classified) LOCATION Class I, Div.1, Group A, B, C, D or Class I, zone 0, AEx ia IIC; Temperature Class T4;-50≤ TA≤ 120°C Common return 1" hose 20 3/4" hose 13 Black conductors from common point. Common return always have 2 common Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF Note 1. HAZARDOUS LOCATION / UNCLASSIFIED LOCATION. + - + - Multiple or single-element temperature sensor Common Return Transmitter cable Note 1. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Max length 100m. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt ≤ 28V Po ≤ 700mW It ≤ 100mA La ≥ 2.5mH + Lcable Ca ≥ 20nF + Ccable ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Common return. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. For installations in the US the associated barriers or galvanic isolators shall be FM Approved. For installations in Canada the associated barriers or galvanic isolators shall be cFM or CSA listed. In both cases the manufacturers installation drawings shall be followed when installing the equipment. Po of the barrier must be less than or equal to the Pi of the apparatus and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. a.The unclassified location apparatus connected to the associated apparatus shall not generate more than the quoted Um of the Associated Apparatus. b.For installations in the US the associated intrinsically safe barriers shall have an appropriate FM Approval. For installations in Canada the associated apparatus shall have an appropriate cFM or CSA Approval. The manufacturers control drawing shall be followed when installing this equipment. c.Installations shall be in accordance with ANSI/ISA RP12.06.01 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Location” and the National Electrical Code ANSI/NFPA 70. Installation in Canada shall be in accordance with the Canadian Electrical Code C22.1 d.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following: Voc or Vt equal or less than Ui Isc or It equal or less than Ii Po equal or less than Pi La equal to or greater than Lcable + Li Ca equal to or greater than Ccable + Ci e.The associated apparatus shall be of like polarity. f.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. g.The Entity Concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of Voc (or Uo) and Isc (or Io) for the associated apparatus are less than or equal to Ui and Ii for the intrinsically safe apparatus and the approved values of Ca(Co) and La(Lo) for the associated apparatus are greater than Ci + Ccable and Li + Lcable, respectively, for the intrinsically safe apparatus. h.WARNING: Substitution of components may impair intrinsic safety and suitability for Division 1/Zone 0 hazardous (classified) Locations. ADVERTISEMENT: La substitution de composants peut compromettre la sécurité intrinsèque. i.Um=250V Drawing Number: Item Description: CONTROL DRAWING for US and Canada 800-9020-FM For hazardous location installation of WLS HART Application: Rev.: 10 First angle projection Scale: Department: Senmatic Instruction No.: 1:1 Industrivej 8 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 16 of 18 + Red - Black RS 485A White RS 485B Green HAZARDOUS (Classified) LOCATION Class I, Div.1, Group A, B, C, D or Class I, zone 0, AEx ia IIC; Temperature Class T4;-50≤ TA≤ 120°C HAZARDOUS LOCATION / UNCLASSIFIED LOCATION. WLS-HART TRANSMITTER Element No. RTD 1 Color codes 3 wire brown-black,black RTD 2 red-black,black RTD 3 orange-black,black RTD 4 yellow-black,black RTD 5 green-black,black RTD 6 blue-black,black RTD 7 violet-black,black RTD 8 grey-black,black RTD 9 white-black,black RTD 10 pink-black,black RTD 11 brown,brown-black RTD 12 red,red-black RTD 13 orange,orange-black RTD 14 yellow,yellow-black RTD 15 green,green-black RTD 16 blue,blue-black RTD 17 violet,violet-black RTD 18 grey,grey-black RTD 19 white,white-black RTD 20 pink,pink-black Max No.of elements 3 wire 1" hose 20 3/4" hose 13 Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF + - Note 1. + - ASSOCIATED APPARATUS WITH ENTITY PARAMETERS Vt Po It La Ca ≤ 28V ≤ 700mW ≤ 100mA ≥ 2.5mH + Lcable ≥ 20nF + Ccable Transmitter cable Multiple or single-element temperature sensor 3 wire Note 1. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD RTD Max length 100m. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. ASSOCIATED APPARATUS WITH ENTITY PARAMETERS The paramenters apply for the total of all elements. Vt Po It La Ca ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. For installations in the US the associated barriers or galvanic isolators shall be FM Approved. For installations in Canada the associated barriers or galvanic isolators shall be cFM or CSA listed. In both cases the manufacturers installation drawings shall be followed when installing the equipment. Po of the barrier must be less than or equal to the Pi of the apparatus and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. a.The unclassified location apparatus connected to the associated apparatus shall not generate more than the quoted Um of the Associated Apparatus. b.For installations in the US the associated intrinsically safe barriers shall have an appropriate FM Approval. For installations in Canada the associated apparatus shall have an appropriate cFM or CSA Approval. The manufacturers control drawing shall be followed when installing this equipment. c.Installations shall be in accordance with ANSI/ISA RP12.06.01 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Location” and the National Electrical Code ANSI/NFPA 70. Installation in Canada shall be in accordance with the Canadian Electrical Code C22.1 d.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following: Voc or Vt equal or less than Ui Isc or It equal or less than Ii Po equal or less than Pi La equal to or greater than Lcable + Li Ca equal to or greater than Ccable + Ci e.The associated apparatus shall be of like polarity. f.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. g.The Entity Concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of Voc (or Uo) and Isc (or Io) for the associated apparatus are less than or equal to Ui and Ii for the intrinsically safe apparatus and the approved values of Ca(Co) and La(Lo) for the associated apparatus are greater than Ci + Ccable and Li + Lcable, respectively, for the intrinsically safe apparatus. h.WARNING: Substitution of components may impair intrinsic safety and suitability for Division 1/Zone 0 hazardous (classified) Locations. ADVERTISEMENT: La substitution de composants peut compromettre la sécurité intrinsèque. i.Um=250V. Drawing Number: Item Description: CONTROL DRAWING for US and Canada 800-9020-FM For hazardous location installation of WLS HART Application: Rev.: 10 First angle projection Scale: Department: Senmatic Instruction No.: 1:1 Industrivej 8 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 17 of 18 + Red - Black RS 485A White RS 485B Green HAZARDOUS (Classified) LOCATION Class I, Div.1, Group A, B, C, D or Class I, zone 0, AEx ia IIC; Temperature Class T4;-50≤ TA≤ 120°C Insulation color codes Element No. 4 wire RTD 1 brown,brown-black,black RTD 2 red,red-black,black RTD 3 orange,orange-black,black RTD 4 yellow,yellow-black,black RTD 5 green,green-black,black RTD 6 blue,blue-black,black RTD 7 violet,violet-black,black RTD 8 grey,grey-black,black RTD 9 white,white-black,black RTD 10 pink,pink-black,black RTD 11 brown/black,brown/black-black,black Ui=28V Pi=700mW Ii=100mA Li=2.5mH Ci=20nF yellow/black,yellow/black-black,black RTD 15 green/black,green/black-black,black RTD 16 Blue/black,Blue/black-black,black Max No.of elements 4wire 1" hose 16 3/4" hose 10 + - Note 1. Transmitter cable Max length 100m. Vt Po It La Ca ≤ 28V ≤ 700mW ≤ 100mA ≥ 2.5mH + Lcable ≥ 20nF + Ccable The paramenters apply for the total of all elements. RTD 4. Ui=7.2V Pi=700mW Ii=400mA Li=40µH Ci=500nF ASSOCIATED APPARATUS WITH ENTITY PARAMETERS ASSOCIATED APPARATUS WITH ENTITY PARAMETERS RTD 3. orange/black,orange/black-black,black RTD 14 Note 1. + - Multiple or single-element temperature sensor RTD 1. 4 wire RTD 2. red/black,red/black-black,black RTD 12 RTD 13 WLS-HART TRANSMITTER HAZARDOUS LOCATION / UNCLASSIFIED LOCATION. RTD 5. Vt Po It La Ca RTD 6. RTD 7. RTD 8. ≤ 7.2V ≤ 700mW ≤ 400mA ≥ 40µH + Lcable ≥ 500nF + Ccable RTD 9. RTD 10. RTD 11. RTD 12. RTD 13. RTD 14. RTD 15. RTD 16. Note 1. Transmitter and RTD cables are non-detachable. Wires shall be terminated properly at terminal blocks in a suitable junction box according to the installation environment. The junction box shall be mounted directly on top of the WLS tube enclosure. Note 2. For installations in the US the associated barriers or galvanic isolators shall be FM Approved. For installations in Canada the associated barriers or galvanic isolators shall be cFM or CSA listed. In both cases the manufacturers installation drawings shall be followed when installing the equipment. Po of the barrier must be less than or equal to the Pi of the apparatus and have Voc or Vt not exceeding Ui and Isc or It not exceeding Ii. a.The unclassified location apparatus connected to the associated apparatus shall not generate more than the quoted Um of the Associated Apparatus. b.For installations in the US the associated intrinsically safe barriers shall have an appropriate FM Approval. For installations in Canada the associated apparatus shall have an appropriate cFM or CSA Approval. The manufacturers control drawing shall be followed when installing this equipment. c.Installations shall be in accordance with ANSI/ISA RP12.06.01 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Location” and the National Electrical Code ANSI/NFPA 70. Installation in Canada shall be in accordance with the Canadian Electrical Code C22.1 d.The Associated apparatus shall single channel or one channel of dual channel barrier with entity parameters complying with the following. Voc or Vt equal or less than Ui Isc or It equal or less than Ii Po equal or less than Pi La equal to or greater than Lcable + Li Ca equal to or greater than Ccable + Ci e.The associated apparatus shall be of like polarity. f.The Transmitter Cable and the Temperature Sensor Cables shall be treated as separate intrinsically safe circuits. g.The Entity Concept allows interconnection of intrinsically safe apparatus with associated apparatus not specifically examined in combination as a system when the approved values of Voc (or Uo) and Isc (or Io) for the associated apparatus are less than or equal to Vmax(Ui) and Imax(Ii) for the intrinsically safe apparatus and the approved values of Ca(Co) and La(Lo) for the associated apparatus are greater than Ci + Ccable and Li + Lcable, respectively, for the intrinsically safe apparatus. h.WARNING: Substitution of components may impair intrinsic safety and suitability for Division 1/Zone 0 hazardous (classified) Locations. ADVERTISEMENT: La substitution de composants peut compromettre la sécurité intrinsèque. i.Um=250V Drawing Number: Item Description: CONTROL DRAWING for US and Canada 800-9020-FM For hazardous location installation of WLS HART Application: Rev.: 10 First angle projection Scale: Department: Senmatic Instruction No.: 1:1 Industrivej 8 DK-5471 Søndersø Denmark Sheet name: Phone +45 6489 2211 Assembly specification sheet Fax +45 6489 3311 This drawing belongs to Senmatic A/S and must not be copied or used without permission. Date/Designed: 29-04-08 / JEH Sheet format: A3 Page 18 of 18
© Copyright 2026 Paperzz