REVISIONS REV DESCRIPTION AA NEW RELEASE CHG.NO. APP'D DATE EC004733 DRV 1/16/04 NOTES: 1. ROSEMOUNT INC. CERTIFIES THIS DRAWING IS IN ACCORDANCE WITH ROSEMOUNT ENGINEERING SPECIFICATIONS AND ACCURATELY REPRESENTS THE EQUIPMENT FURNISHED. 2. ORIFICE FLANGE UNIONS MEET THE REQUIREMENTS OR ANSI B16.36. 3. FOR MODEL SELECTIONS, MATERIALS, AND OPTIONS, REFER TO ROSEMOUNT PRODUCT DATA SHEET 00813-0100-4792. 4. MODEL 1496 MAXIMUM TEMPERATURE IS 850°F. MAXIMUM OPERATING TEMPERATURE MAY BE REDUCED DEPENDING ON MATERIAL AND GASKET SELECTIONS. REFER TO ROSEMOUNT PRODUCT DATA SHEET 00813-0100-4792 FOR DETAILS. 5. MODEL 1496 INCLUDES FLANGE UNIONS, STUDS, NUTS, GASKETS, JACK SCREWS, AND PLUGS (PLUGS ARE NOT SUPPLIED WITH SOCKET TAP FLANGES). 6. OVERALL LENGTHS IN TABLES 1 & 3 ARE CALCULATED BASED ON A 1/8” THICK ORIFICE PLATE (ORDERED SEPERATELY) AND 1/16” THICK FLANGE GASKETS (INCLUDED). ACTUAL LENGTHS MAY VARY DEPENDING ON ACTUAL PLATE THICKNESS AND GASKETS USED. 7. STANDARD GASKET IS 1/16” THICK NON-ASBESTOS TYPE. FOR SERVICE RATINGS OF ANSI 600# AND OVER, 1/8” THICK SPIRAL WOUND GASKETS ARE SUPPLIED AS STANDARD. TYPE I *UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM) *ALL DIMENSIONS ARE NOMINAL AND ARE FOR REFERENCE ONLY DMK DR. BOULDER, COLORADO 12/15/03 TITLE APPROVAL DRAWING TAGGING SPECIALS K. GREEN 12/19/04 DIMENSIONAL DRAWING FOR MODEL 1496 ORIFICE FLANGE UNION SIZE DRAWING NO. A SCALE: NONE Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 1 OF 10 TABLE 1 TABLE 3 OVERALL LENGTH (DIN FLANGES) OVERALL LENGTH LINE SIZE 1496WN 1496RJ 1496SO 1496TH 300# 600# 900# 1500# 2500# 600# 900# 1500# 2500# 300# 300# 2" 7.00 7.00 8.75 8.75 10.75 7.69 9.06 9.06 11.06 1.94 1.94 2-1/2" 7.25 7.25 9.00 9.00 12.00 7.94 9.31 9.31 12.44 2.00 2.00 3" 7.25 7.25 8.75 10.00 14.00 7.94 9.06 10.31 14.44 2.06 4" 7.50 8.75 9.75 10.50 15.75 8.06 10.06 10.81 16.31 2.12 6" 8.13 10.00 11.75 14.25 22.25 9.19 12.06 14.63 22.94 2.12 1496DN LINE SIZE PN10 PN16 PN25 PN40 PN64 PN100 IN MM IN MM IN MM IN MM IN MM IN MM DN50 5.24 133 5.24 133 5.31 135 5.31 135 5.94 151 6.26 159 2.06 DN65 5.24 133 5.24 133 5.47 139 5.47 139 6.42 163 6.73 171 2.12 DN80 5.47 139 5.47 139 5.79 147 5.79 147 6.57 167 6.73 171 2.12 DN100 5.63 143 5.63 143 6.34 161 6.34 161 6.89 175 7.52 191 2.44 8" 9.00 11.25 13.50 17.50 25.75 10.31 13.81 18.06 26.56 2.44 DN150 5.71 145 5.71 145 6.81 173 6.81 173 7.91 201 9.49 241 10" 9.50 12.75 15.25 20.75 33.75 10.81 15.56 21.31 34.88 2.62 DN200 6.10 155 6.10 155 7.05 179 7.36 187 9.09 231 10.67 271 12" 10.50 13.00 16.50 23.00 37.25 11.81 16.81 23.81 38.50 2.88 DN250 6.42 163 6.57 167 7.52 191 8.50 216 10.28 261 12.80 325 14" 11.50 13.75 17.50 24.25 12.81 18.06 25.25 3.00 DN300 6.42 163 7.05 179 7.68 195 9.29 236 11.46 291 13.82 351 16" 11.75 14.75 17.75 25.25 13.19 18.44 26.50 3.25 DN350 6.42 163 7.20 183 8.11 206 10.08 256 12.24 311 15.31 389 18" 12.75 15.25 18.75 26.50 14.19 19.56 27.75 3.50 DN400 6.73 171 7.28 185 8.90 226 10.87 276 13.03 331 20" 13.00 15.75 20.25 28.75 14.50 21.06 30.13 3.75 DN500 6.81 173 7.52 191 10.08 256 11.26 286 24" 13.50 16.75 23.75 32.75 15.19 24.88 34.31 4.19 TABLE 4 TABLE 2 FLANGE DIAMETER (DIN FLANGES) FLANGE OUTSIDE DIAMETER LINE SIZE 300# 600# 900# 1500# 2500# 2" 6.50 6.50 8.50 8.50 9.25 2-1/2" 7.50 7.50 9.62 9.62 10.50 1496DN LINE SIZE PN10 PN16 PN25 PN40 PN64 PN100 IN MM IN MM IN MM IN MM IN MM IN MM DN50 6.50 165 6.50 165 6.50 165 6.50 165 7.09 180 7.68 195 220 3" 4" 8.25 10.00 8.25 10.75 9.50 11.50 10.50 12.25 12.00 14.00 6" 8" 12.50 15.00 14.00 16.50 15.00 18.50 15.50 19.00 19.00 21.75 DN65 7.28 185 7.28 185 7.28 185 7.28 185 8.07 205 8.66 DN80 7.87 200 7.87 200 7.87 200 7.87 200 8.46 215 9.06 230 10" 12" 17.50 20.50 20.00 22.00 21.50 24.00 23.00 26.50 26.50 30.00 DN100 8.66 220 8.66 220 9.25 235 9.25 235 9.84 250 11.22 285 DN150 11.22 285 11.22 285 11.81 300 11.81 300 13.58 345 13.98 355 14" 23.00 23.75 25.25 29.50 DN200 13.39 340 13.39 340 14.17 360 14.76 375 16.34 415 16.93 430 16" 18" 25.50 28.00 27.00 29.25 27.75 31.00 32.50 36.00 DN250 15.55 395 15.94 405 16.73 425 17.72 450 18.50 470 19.88 505 DN300 17.52 445 18.11 460 19.09 485 20.28 515 20.87 530 23.03 585 20" 24" 30.50 36.00 32.00 37.00 33.75 41.00 38.75 46.00 DN350 19.88 505 20.47 520 21.85 555 22.83 580 23.62 600 25.79 655 DN400 23.03 585 22.83 580 24.41 620 25.98 660 26.38 670 DN500 26.38 670 28.15 715 28.74 730 29.72 755 BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 2 OF 10 OVERALL LENGTH (SEE TABLES 1 & 3 ON PAGE 2) OD (SEE TABLES 2 & 4 ON PAGE 2) ORIFICE FLANGE UNION ASSEMBLY BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 3 OF 10 .94 1/2" TAP (NPT OR SOCKET) SECTION L-L L L ORIFICE FLANGE UNION, RAISED FACE, WELD NECK BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 4 OF 10 .75 1/2" TAP (NPT OR SOCKET) SECTION M-M M M ORIFICE FLANGE UNION, RING JOINT, WELD NECK BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 5 OF 10 .94 1/2" TAP (NPT OR SOCKET) N SECTION N-N N ORIFICE FLANGE UNION, RAISED FACE, SLIP-ON BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 6 OF 10 .94 1/2" TAP (NPT OR SOCKET) SECTION P-P P P ORIFICE FLANGE UNION, RAISED FACE, THREADED BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 7 OF 10 R THREADS G 1/2 A (ISO 228/1) 2.45 (100 MM) .94 (24 MM) SECTION R-R R ORIFICE FLANGE UNION RAISED FACE, WLEDNECK DIN 19214 PART 1 BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 8 OF 10 GASKET THICKNESS (SEE NOTE 7) OD (SEE TABLE 2 ON PAGE 2) GASKET BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 9 OF 10 FLANGES MUST ALIGN SO THAT BOLTS PASS THROUGH BOLT HOLES WITH NO INTERFERENCE FLANGES ALIGNED SO THAT BOLT HOLES DO NOT FALL ON THE NATURAL HORIZONTAL AND VERTICAL CENTERLINE OF PIPE (2) JACK SCREW NUT STUD TAP PLUG GASKET DETAIL A 1495 (NOT INCLUDED) ORIFICE FLANGE (2) JACK SCREW NUT EXPLODED INSTALLATION VIEW BOULDER, COLORADO SIZE FSCM.NO. DRAWING NO. A SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary 01496-1001 SHEET 10 OF 10
© Copyright 2026 Paperzz