REVISIONS REV RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHEET 2 FOR SIZES) STUDS, NUTS & GASKET DESCRIPTION AD ENSURE THAT THE VALVE HANDLE/ACTUATOR WHEEL IS CENTERED BETWEEN INSERTION RODS AND THAT INSERTION RODS STRADDLE PIPE GENERAL UPDATES CHG.NO. APP'D DATE DSI1003490 JR 09/15/10 4.00 [101,6] VALVE BONNET ASSY. 3.00 [76,2] SENSOR SIZE 1 LOCKING PIN 9.00 [228,6] MAX. 10.50 [266,7] OPTIONAL RTD PORT 5.50 [139,7] MAX. 3 LOW PRESSURE INSTRUMENT VALVE HIGH PRESSURE INSTRUMENT VALVE EQUALIZER VALVE PACKING ASSY. FLOW MANUAL INSERT/ RETRACT ASSY. 4X 3/8-16 THREADED HOLES FOR MOUNTING SUPPORT ODF ID ISOLATION VALVE FULL PORT BALL (SHOWN) OR GATE STYLE (SEE SHEET 2) WALL NOTICE INTEGRAL MOUNT HEAD OPTION FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 3/4 (19mm) INCH DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE RF FLANGE, WELD FTG., STUDS, NUTS & GASKET ODV ODH PROBE INSERTED: PI FORMULA FOR 'PI' = ID + WALL + ODV + 17.77 [451,4] FLANGED PROBE RETRACTED: PR FORMULA FOR 'PR' = 2x (ID + WALL + ODV) + 17.77 [451,4] FLANGED OW FL NOTE: UNLESS OTHERWISE SPECIFIED ALL INFORMATION IS BOTH (TYP) & GENERAL TO STANDARD PRODUCT DESIGN ALL PIPE SECTIONS SHOWN FOR REFERENCE ONLY J.PAYLOR DR. BOULDER, COLORADO 10/4/05 TITLE DIMENSION DRAWING, MODEL 485 ANNUBAR FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA) SENSOR SIZE 1 FLANGED / THREADED FLO-TAP 150# - 600# ANSI APPROVAL DRAWING TAGGING SPECIALS Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary ® TYPE I *UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM) *ALL DIMENSIONS ARE NOMINAL AND ARE FOR REFERENCE ONLY FLANGED MANUAL FLO-TAP SENSOR SIZE 1 D.VERHAAGEN 1/9/06 SIZE A SCALE: NONE DRAWING NO. 00485-1012 SHEET 1 OF 4 VL VL THREADED FULL PORT GATE VALVES FLANGED FULL PORT GATE VALVES FULL PORT GATE VALVES VL VL THREADED FULL PORT BALL VALVES FLANGED FULL PORT BALL VALVES FULL PORT BALL VALVES ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary DRAWING NO. 00485-1012 SHEET 2 OF 4 3051S TRANSMITTER EQUALIZER VALVE 3051SFA, STD HARDWARE TEMP WIDTH WIDTH FLOWMETER HEIGHT WIDTH 2051CFA 7.03 [178,5] 5.50 [139,7] 3051CFA 7.1 [181] 5.67 [144,0] 3051SFA 8.53 [216,7] 5.67 [144,0] 3095MFA 7.1 [181] 5.67 [144,0] TEMP WIDTH 10.09 [256,3] HEIGHT LOW PRESSURE INSTRUMENT VALVE ® HIGH PRESSURE INSTRUMENT VALVE BOULDER, COLORADO 3051SFA SHOWN SIZE A FSCM.NO. SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary DRAWING NO. 00485-1012 SHEET 3 OF 4 LOW-PRESSURE INSTRUMENT CONNECTION HIGH-PRESSURE INSTRUMENT CONNECTION ODH: PROBE INSERTED: PI FORMULA FOR 'PI' = ID + WALL + ODV + 16.96 [430,8] THREADED PROBE RETRACTED: PR FORMULA FOR 'PR' = 2x (ID + WALL + ODV) + 16.96 [430,8] THREADED ODV ISOLATION VALVE THREADED FULL PORT GATE VALVE SHOWN FLOW THREADED FLO-TAP WITH FULL PORT GATE VALVE HORIZONTAL FLOW REMOTE MOUNT INSTRUMENT CONNECTIONS (NEEDLE VALVES SHOWN) OW FL ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary DRAWING NO. 00485-1012 SHEET 4 OF 4
© Copyright 2026 Paperzz