REVISIONS
RF MOUNTING FLANGE
& WELD FTG.
(SEE TABLE/SHEET 2 FOR SIZES)
STUDS, NUTS & GASKET
DESCRIPTION
REV
ENSURE THAT THE VALVE HANDLE/ACTUATOR WHEEL
IS CENTERED BETWEEN INSERTION RODS
AND THAT INSERTION RODS STRADDLE PIPE
AE
GENERAL UPDATES
CHG.NO.
APP'D
DATE
DSI1003490
JR
09/15/10
OPTIONAL RTD PORT
SENSOR
SIZE 2
LOCKING PIN
HIGH PRESSURE
INSTRUMENT VALVE
6.00
[152,4]
9.0
[228,6]
MAX
18.3
[464,7]
LOW
PRESSURE
INSTRUMENT
VALVE
EQUALIZER VALVE
12.56
[319,0]
VALVE BONNET
ASSY.
9.00
[228,6]
MAX.
PACKING ASSY.
3
5.7
[464,7]
FLOW
10.5
[266,7]
GEAR
DRIVE
INSERT/
RETRACT
ASSY.
5.50
[139,7]
MAX.
12.3
[312,4]
ODF
ID
4X 3/8-16 THREADED HOLES
FOR MOUNTING SUPPORT
INTEGRAL MOUNT
HEAD OPTION
WALL
ISOLATION
VALVE
FULL PORT BALL (SHOWN)
OR GATE STYLE
(SEE SHEET 2)
CAUTION
FOR ACCURATE FLOW MEASUREMENT
THE CORRECT HOLE SIZE IN PIPE MUST BE:
1-5/16 INCH (34mm)
DO NOT DRILL OVERSIZE
DO NOT TORCH CUT HOLE
ODV
ODH MAX.
RF FLANGE,
WELD FTG.,
STUDS, NUTS
& GASKET
PROBE INSERTED: PI
FORMULA FOR 'PI' = ID + WALL + ODV + 24.44 [620,8] FLANGED/GEAR DRIVE
PROBE RETRACTED: PR
FORMULA FOR 'PR' = 2x (ID + WALL + ODV) + 24.44 [620,8] FLANGED/GEAR DRIVE
(SEE SHT 4 FOR MANUAL STYLE/SHEET 5 FOR THREADED GEAR DRIVE)
OW
FL
NOTE: UNLESS OTHERWISE SPECIFIED
ALL INFORMATION IS BOTH (TYP) & GENERAL
TO STANDARD PRODUCT DESIGN
ALL PIPE SECTIONS SHOWN FOR REFERENCE ONLY
J.PAYLOR
DR.
®
BOULDER, COLORADO
10/6/05
TITLE DIMENSION DRAWING, MODEL 485 ANNUBAR
APPROVAL
DRAWING
TAGGING
SPECIALS
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
SEE SHEET 4 FOR MANUAL / FLO-TAP WITH GATE VALVE EXAMPLE
SEE SHEET 5 FOR THREADED / FLO-TAP
TYPE I
*UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES (MM)
*ALL DIMENSIONS ARE NOMINAL
AND ARE FOR REFERENCE ONLY
FLANGED / GEAR DRIVE FLO-TAP
SENSOR SIZE 2
D.VERHAAGEN
1/9/06
SIZE
FLOWMETER (3051SFA, 3051CFA 2051CFA,
3095MFA) SENSOR SIZE 2 FLANGED/THREADED
FLO-TAP 150# - 600# ANSI
C
SCALE: NONE
DRAWING NO.
00485-1014
SHEET
1
OF
5
VL
FULL PORT BALL VALVE / FLANGED
VL
FULL PORT BALL VALVE / THREADED
VL
FULL PORT GATE VALVE / FLANGED
VL
FULL PORT GATE VALVE / THREADED
®
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
DRAWING NO.
00485-1014
SHEET
2
OF
5
3051S TRANSMITTER
EQUALIZER
VALVE
3051SFA, STD HARDWARE
TEMP WIDTH
WIDTH
FLOWMETER
HEIGHT
WIDTH
2051CFA
7.03
[178,5]
5.50
[139,7]
3051CFA
7.1
[181]
5.67
[144,0]
3051SFA
8.53
[216,7]
5.67
[144,0]
3095MFA
7.1
[181]
5.67
[144,0]
TEMP
WIDTH
10.09
[256,3]
HEIGHT
LOW PRESSURE
INSTRUMENT VALVE
®
HIGH PRESSURE INSTRUMENT VALVE
3051SFA SHOWN
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
DRAWING NO.
00485-1014
SHEET
3
OF
5
MANUAL
INSERT/RETRACT
ASSEMBLY
SENSOR
SIZE 2
ISOLATION VALVE
FULL PORT GATE STYLE
SHOWN
FLOW
3
ID
WALL
W
FLO
ODF
ODH MAX.
PROBE INSERTED: PI
FORMULA FOR 'PI' = ID + WALL + ODV + 21.20" [538,5] MANUAL/FLANGED
PROBE RETRACTED: PR
FORMULA FOR 'PR' = 2x (ID + WALL + ODV) + 21.20" [538,5] MANUAL/FLANGED
ODV
NOTICE
FLANGED / MANUAL FLOW TAP
FOR ACCURATE FLOW MEASUREMENT
THE CORRECT HOLE SIZE IN PIPE MUST BE:
NOTE: SHOWN WITH FULL PORT GATE VALVE
(INTEGRAL MOUNT HEAD STYLE SHOWN)
1-5/16 INCH(34mm)
DO NOT DRILL OVERSIZE
DO NOT TORCH CUT HOLE
NOTE: ALL OTHER INFORMATION IS THE SAME
AS THAT SHOWN FOR GEAR DRIVE STYLE FLO-TAP
SHOWN ON SHEET 1
FLANGED / MANUAL FLOW TAP
®
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
DRAWING NO.
00485-1014
SHEET
4
OF
5
SENSOR SIZE 2
FLOW
HIGH PRESSURE
INSTRUMENT
CONNECTION
LOW PRESSURE
INSTRUMENT
CONNECTION
ODV
ID
WALL
REMOTE MOUNT HEAD OPTION
ODH MAX.
ISOLATION VALVE
FULL PORT BALL VALVE (SHOWN)
PROBE INSERTED: PI
FORMULA FOR 'PI' = ID + WALL + ODV + 23.62 [599,9] THREADED/GEAR DRIVE
+ 20.39 [517,9] THREADED/MANUAL DRIVE
PROBE RETRACTED: PR
FORMULA FOR 'PR' = 2x (ID + WALL + ODV) + 23.62 [599,9] THREADED/GEAR DRIVE
+ 20.39 [517,9] THREADED/MANUAL DRIVE
NOTICE
FOR ACCURATE FLOW MEASUREMENT
THE CORRECT HOLE SIZE IN PIPE MUST BE:
1-5/16 INCH(34mm)
DO NOT DRILL OVERSIZE
DO NOT TORCH CUT HOLE
W
FLO
THREADED / GEAR DRIVE FLO-TAP
REMOTE MOUNT HEAD OPTION
AVAILABLE IN BOTH MANUAL & GEAR DRIVEN CONFIGURATIONS
WITH OR WITHOUT INTEGRAL TEMPERATURE SENSOR
SOCKET WELD OR NPT CONNECTIONS AVAIL.
®
BOULDER, COLORADO
SIZE
A
SCALE:
Electronic Master – PRINTED COPIES ARE UNCONTROLLED – Rosemount Proprietary
FSCM.NO.
1:8
WT.
DRAWING NO.
00485-1014
SHEET:
5
of
5