PDF

RF MOUNTING FLANGE
& WELD FTG.
(SEE TABLE/SHEET 2 FOR SIZES)
STUDS, NUTS & GASKET
(NOTE: ONLY REMOTE MOUNT AVAILABLE
ABOVE 600# ANSI)
REVISIONS
DESCRIPTION
REV
AD
ADDED LOW TEIR TRANSMITTER
CHG.NO.
APP'D
DATE
DSI1003150
JR
02/15/10
5.50
(139.7)
MAX.
'O'
DIA.
(SEE TABLE/SHT 2 FOR SIZES)
OPTIONAL RTD PORT
HIGH PRESSURE
INSTRUMENT VALVE
9.00
(228.6)
MAX.
LOW PRESSURE
INSTRUMENT VALVE
LOCKING PIN
VALVE BONNET ASSY
EQUALIZER VALVE
3
3
RF SENSOR FLANGE
(SEE TABLE/SHT 2 FOR SIZES)
FLOW
SENSOR SIZE 3
ODP
ID
WALL
ODF
INTEGRAL MOUNT HEAD OPTION
OW
OSS SIZE
WELDED OPPOSITE
SIDE SUPPORT
(SEE TABLE/SHEET 2
FOR SIZES)
FL
NOTICE
ODH
INTEGRAL MOUNT
WITH
OPPOSITE SIDE SUPPORT
(150# THRU 600# ANSI SHOWN)
FOR ACCURATE FLOW MEASUREMENT
THE CORRECT HOLE SIZE IN PIPE MUST BE:
2-1/2 INCH(64mm)
DO NOT DRILL OVERSIZE
DO NOT TORCH CUT HOLE
NOTE: UNLESS OTHERWISE SPECIFIED
ALL INFORMATION IS BOTH (TYP) & GENERAL
TO STANDARD PRODUCT DESIGN
ALL PIPE SECTIONS SHOWN FOR REFERENCE ONLY
*ALL DIMENSIONS ARE NOMINAL
AND ARE FOR REFERENCE ONLY
®
TYPE I
*UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN INCHES (MM)
jpaylor
DR.
BOULDER, COLORADO
8/15/05
APPROVAL
DRAWING
TAGGING
SPECIALS
D.VERHAAGEN
9/1/05
TITLE
DIMENSION DRAWING, MODEL 485 ANNUBAR
FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA)
SENSOR SIZE 3 FLANGED 150#-2500# ANSI
SIZE
C
SCALE: NONE
DRAWING NO.
00485-1015
SHEET
1
OF
5
®
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
DRAWING NO.
00485-1015
SHEET
2
OF
5
3051S TRANSMITTER
EQUALIZER
VALVE
3051SFA, STD HARDWARE
6.36
(161.5)
MAX.
FLOWMETER
HEIGHT
WIDTH
2051CFA
7.03
[178,5]
5.50
[139,7]
3051CFA
7.1
(181)
5.67
[144,0]
3051SFA
8.53
(216.7)
5.67
[144,0]
3095MFA
7.1
(181)
5.67
[144,0]
TEMP
WIDTH
10.09
[256,3]
8.53
(216.7)
LOW PRESSURE
INSTRUMENT
VALVE
®
HIGH PRESURE
INSTRUMENT VALVE
3051SFA SHOWN
485/3051SFA/3095MFA
INTEGRAL MOUNT HEAD
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
DRAWING NO.
00485-1015
SHEET
3
OF
5
LOW PRESSURE
INSTRUMENT
CONNECTION
3" RF MOUNTING FLANGE
& WELD FTG.
(UP TO 600#)
(SEE TABLE/SHT 2 FOR SIZES)
STUDS, NUTS & GASKETS
SEE SHEET 5 FOR ABOVE 600# ANSI
(NOTE: ONLY REMOTE MOUNT AVAILABLE
FOR ABOVE 600# ANSI)
HIGH PRESSURE
INSTRUMENT CONNECTION
SENSOR SIZE 3
RF SENSOR FLANGE
(SEE TABLE/SHT 2 FOR SIZES)
AVAILABLE IN SW & NPT
CONNECTIONS
W
3
FL
O
ODF + BFT + .125(3,2)
ODH
FLOW
ID
ODF
REMOTE MOUNT
FLANGED
OPPOSITE SIDE SUPPORT
WALL
ALSO AVAILABLE
FOR HIGH PRESSURE APPLICATIONS
(SEE SHEET 5)
(150# THRU 600# ANSI SHOWN)
REMOTE MOUNT HEAD OPTION
NOTICE
FLANGED OPPOSITE SIDE
SUPPORT ASSY.
FOR ACCURATE FLOW MEASUREMENT
THE CORRECT HOLE SIZE IN PIPE MUST BE:
2-1/2 INCH(64mm)
DO NOT DRILL OVERSIZE
DO NOT TORCH CUT HOLE
®
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
DRAWING NO.
00485-1015
SHEET
4
OF
5
RF MOUNTING FLANGE,
(SEE TABLE/SHT 2 FOR SIZES)
STUDS,NUTS & GASKET
RF SENSOR FLANGE
(SEE TABLE/SHT 2 FOR SIZE)
LOW PRESSURE
INSTRUMENT
CONNECTION
SENSOR SIZE 3
3
3
SW OR NPT
INSTRUMENT CONNECTION
FLOW
HIGH PRESSURE
INSTRUMENT CONNECTION
ODP
ID
ODF
WALL
HIGH PRESSURE,
REMOTE MOUNT
HEAD OPTION
OW
FL
OSS SIZE
WELDED OPPOSITE SIDE
SUPPORT
(SEE TABLE/SHEET 2)
NOTICE
ODH
HI-PRESSURE REMOTE MOUNT
WITH
OPPOSITE SIDE SUPPORT
FOR ACCURATE FLOW MEASUREMENT
THE CORRECT HOLE SIZE IN PIPE MUST BE:
2-1/2 INCH(64mm)
DO NOT DRILL OVERSIZE
DO NOT TORCH CUT HOLE
(900# & ABOVE ANSI SHOWN)
®
BOULDER, COLORADO
SIZE
A
FSCM.NO.
SCALE: NONE WT.
DRAWING NO.
00485-1015
SHEET
5
OF
5