RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHEET 2 FOR SIZES) STUDS, NUTS & GASKET (NOTE: ONLY REMOTE MOUNT AVAILABLE ABOVE 600# ANSI) REVISIONS DESCRIPTION REV AD ADDED LOW TEIR TRANSMITTER CHG.NO. APP'D DATE DSI1003150 JR 02/15/10 5.50 (139.7) MAX. 'O' DIA. (SEE TABLE/SHT 2 FOR SIZES) OPTIONAL RTD PORT HIGH PRESSURE INSTRUMENT VALVE 9.00 (228.6) MAX. LOW PRESSURE INSTRUMENT VALVE LOCKING PIN VALVE BONNET ASSY EQUALIZER VALVE 3 3 RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZES) FLOW SENSOR SIZE 3 ODP ID WALL ODF INTEGRAL MOUNT HEAD OPTION OW OSS SIZE WELDED OPPOSITE SIDE SUPPORT (SEE TABLE/SHEET 2 FOR SIZES) FL NOTICE ODH INTEGRAL MOUNT WITH OPPOSITE SIDE SUPPORT (150# THRU 600# ANSI SHOWN) FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 2-1/2 INCH(64mm) DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE NOTE: UNLESS OTHERWISE SPECIFIED ALL INFORMATION IS BOTH (TYP) & GENERAL TO STANDARD PRODUCT DESIGN ALL PIPE SECTIONS SHOWN FOR REFERENCE ONLY *ALL DIMENSIONS ARE NOMINAL AND ARE FOR REFERENCE ONLY ® TYPE I *UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM) jpaylor DR. BOULDER, COLORADO 8/15/05 APPROVAL DRAWING TAGGING SPECIALS D.VERHAAGEN 9/1/05 TITLE DIMENSION DRAWING, MODEL 485 ANNUBAR FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA) SENSOR SIZE 3 FLANGED 150#-2500# ANSI SIZE C SCALE: NONE DRAWING NO. 00485-1015 SHEET 1 OF 5 ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1015 SHEET 2 OF 5 3051S TRANSMITTER EQUALIZER VALVE 3051SFA, STD HARDWARE 6.36 (161.5) MAX. FLOWMETER HEIGHT WIDTH 2051CFA 7.03 [178,5] 5.50 [139,7] 3051CFA 7.1 (181) 5.67 [144,0] 3051SFA 8.53 (216.7) 5.67 [144,0] 3095MFA 7.1 (181) 5.67 [144,0] TEMP WIDTH 10.09 [256,3] 8.53 (216.7) LOW PRESSURE INSTRUMENT VALVE ® HIGH PRESURE INSTRUMENT VALVE 3051SFA SHOWN 485/3051SFA/3095MFA INTEGRAL MOUNT HEAD BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1015 SHEET 3 OF 5 LOW PRESSURE INSTRUMENT CONNECTION 3" RF MOUNTING FLANGE & WELD FTG. (UP TO 600#) (SEE TABLE/SHT 2 FOR SIZES) STUDS, NUTS & GASKETS SEE SHEET 5 FOR ABOVE 600# ANSI (NOTE: ONLY REMOTE MOUNT AVAILABLE FOR ABOVE 600# ANSI) HIGH PRESSURE INSTRUMENT CONNECTION SENSOR SIZE 3 RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZES) AVAILABLE IN SW & NPT CONNECTIONS W 3 FL O ODF + BFT + .125(3,2) ODH FLOW ID ODF REMOTE MOUNT FLANGED OPPOSITE SIDE SUPPORT WALL ALSO AVAILABLE FOR HIGH PRESSURE APPLICATIONS (SEE SHEET 5) (150# THRU 600# ANSI SHOWN) REMOTE MOUNT HEAD OPTION NOTICE FLANGED OPPOSITE SIDE SUPPORT ASSY. FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 2-1/2 INCH(64mm) DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1015 SHEET 4 OF 5 RF MOUNTING FLANGE, (SEE TABLE/SHT 2 FOR SIZES) STUDS,NUTS & GASKET RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE) LOW PRESSURE INSTRUMENT CONNECTION SENSOR SIZE 3 3 3 SW OR NPT INSTRUMENT CONNECTION FLOW HIGH PRESSURE INSTRUMENT CONNECTION ODP ID ODF WALL HIGH PRESSURE, REMOTE MOUNT HEAD OPTION OW FL OSS SIZE WELDED OPPOSITE SIDE SUPPORT (SEE TABLE/SHEET 2) NOTICE ODH HI-PRESSURE REMOTE MOUNT WITH OPPOSITE SIDE SUPPORT FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 2-1/2 INCH(64mm) DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE (900# & ABOVE ANSI SHOWN) ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1015 SHEET 5 OF 5
© Copyright 2026 Paperzz