REVISIONS DESCRIPTION REV AF GENERAL UPDATES RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHEET 2 FOR SIZES) STUDS, NUTS & GASKET CHG.NO. APP'D DATE DSI1050187 JR 07/07/11 OPTIONAL RTD PORT HIGH PRESSURE INSTRUMENT VALVE 5.50 [139,7] MAX. SENSOR SIZE 2 3 LOW PRESSURE INSTRUMENT VALVE LOCKING PIN EQUALIZER VALVE 9.00 (228.6) MAX. VALVE BONNET ASSY OSS SIZE OPPOSITE SIDE SUPPORT SEE TABLE/SHT 2 FOR SIZES (WELDED SHOWN) DIA. 'O' (SEE TABLE/SHT 2 FOR SIZES) RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZES) 3 ODH ID OW ODF FL FLOW ODP INTEGRAL MOUNT WITH OPPOSITE SIDE SUPPORT (150# THRU 600# ANSI SHOWN) INTEGRAL MOUNT HEAD OPTION WALL CAUTION FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 1-5/16 INCH(34mm) NOTE: UNLESS OTHERWISE SPECIFIED ALL INFORMATION IS BOTH (TYP) & GENERAL TO STANDARD PRODUCT DESIGN ALL PIPE SECTIONS SHOWN FOR REFERENCE ONLY DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE *ALL DIMENSIONS ARE NOMINAL AND ARE FOR REFERENCE ONLY ® TYPE I *UNLESS OTHERWISE SPECIFIED DIMENSIONS IN INCHES (MM) jpaylor DR. BOULDER, COLORADO 4/1/05 TITLE DIMENSION DRAWING, MODEL 485 ANNUBAR APPROVAL M.MONTGOMERY DRAWING TAGGING SPECIALS 6/7/05 SIZE FLOWMETER (3051SFA, 3051CFA 2051CFA, 3095MFA) SENSOR SIZE 2 FLANGED 150# - 2500# ANSI C SCALE: NONE DRAWING NO. 00485-1013 SHEET 1 OF 5 3 NPT THREADED FTG. ODP WELD FTG. OSS SIZE OSS SIZE ODP 3 TIP OPTION 'C' TIP OPTION 'D' EXTENDED TIP/WELDED EXTENDED TIP/NPT THREADED OPPOSITE SIDE SUPPORT OPTIONS ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1013 SHEET 2 OF 5 3051S TRANSMITTER EQUALIZER VALVE 3051SFA, STD HARDWARE TEMP WIDTH WIDTH FLOWMETER HEIGHT WIDTH 2051CFA 7.03 [178,5] 5.50 [139,7] 3051CFA 7.1 (181) 5.67 [144,0] 3051SFA 8.53 (216.7) 5.67 [144,0] 3095MFA 7.1 (181) 5.67 [144,0] TEMP WIDTH 10.09 [256,3] HEIGHT LOW PRESSURE INSTRUMENT VALVE HIGH PRESSURE INSTRUMENT VALVE 485/3051SFA/3095MFA INTEGRAL MOUNT HEAD 3051SFA SHOWN ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1013 SHEET 3 OF 5 2" RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHT 2 FOR SIZES) GASKETS,STUDS & NUTS SENSOR SIZE 2 LOW PRESSURE INSTRUMENT CONNECTION RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZES) 3 HIGH PRESSURE INSTRUMENT CONNECTION ODF + BFT + .125(3,2) FLOW ID ODH ODF WALL REMOTE MOUNT HEAD OPTION W FLO REMOTE MOUNT FLANGED OPPOSITE SIDE SUPPORT (150# THRU 600# ANSI SHOWN) CAUTION FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: FLANGED OPPOSITE SIDE SUPPORT ASSY. 1-5/16 INCH(34mm) ALSO AVAILABLE FOR HIGH PRESSURE APPLICATIONS DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE ® BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1013 SHEET 4 OF 5 3 SENSOR SIZE 2 1/2" SW OR NPT PORTS 3 RF SENSOR FLANGE (SEE TABLE/SHT 2 FOR SIZE) RF MOUNTING FLANGE & WELD FTG. (SEE TABLE/SHT 2 FOR SIZES) STUDS,NUTS & GASKET LOW PRESSURE INSTRUMENT CONNECTION HIGH PRESSURE INSTRUMENT CONNECTION ODH FLOW ID ODF WALL ODP W FLO OSS SIZE HIGH PRESSURE, REMOTE MOUNT HEAD OPTION (SEE TABLE/SHT 2 FOR SIZE) HI-PRESSURE REMOTE MOUNT WITH OPPOSITE SIDE SUPPORT (900# & ABOVE ANSI SHOWN) CAUTION ® FOR ACCURATE FLOW MEASUREMENT THE CORRECT HOLE SIZE IN PIPE MUST BE: 1-5/16 INCH(34mm) DO NOT DRILL OVERSIZE DO NOT TORCH CUT HOLE BOULDER, COLORADO SIZE A FSCM.NO. SCALE: NONE WT. DRAWING NO. 00485-1013 SHEET 5 OF 5
© Copyright 2026 Paperzz