PDF

1
A
3
2
4
6
5
9
8
7
10
11
12
14
13
REVISION
ECO NO.
APP'D
DATE
AB
RTC106605
T. MCCULLOCH
06/28/16
A
DESCRIPTION
UPDATE TITLEBLOCK
STAINLESS STEEL PROCESS WETTED
PLANTWEB HOUSING
SHOWN WITH OPTIONAL DIGITAL DISPLAY
5.17
[131]
16
REVISION TABLE
ROSEMOUNT 4088 IN-LINE PRESSURE TRANSMITTER
1/2-14 NPT FEMALE PROCESS CONNECTION
B
15
ALLOY C-276 PROCESS WETTED
PLANTWEB HOUSING
PLANTWEB HOUSING
CERTIFICATION LABEL
4.51
[115]
CONDUIT CONNECTION
(2 PLACES)
B
PRESSURE RANGE OPTION 5
C
C
D
D
TRANSMITTER
ELECTRONICS
(THIS SIDE)
FIELD TERMINALS
(THIS SIDE)
DIGITAL
DISPLAY
COVER
HOUSING
ROTATION
SET SCREW
8.29
[210]
E
E
NAMEPLATE
F
F
1/2-14 NPT FEMALE
PRESSURE RANGE OPTION 5
G
PLANTWEB HOUSING
PRESSURE RANGE OPTION 1-4
PRESSURE RANGE OPTION 1-4
4.20
[107]
G
H
H
J
J
8.04
[204]
8.14
[207]
8.19
[208]
L
L
1.38
[35]
FORM REV AA
M
1.13
[29]
REFERENCE ROSEMOUNT
PRODUCT DATA SHEETS FOR
PRODUCT SPECIFICATIONS.
CLICK HERE
K
©2015 ROSEMOUNT INC.
ROSEMOUNT INC CERTIFIES
THESE DRAWINGS ARE IN
ACCORDANCE WITH
ROSEMOUNT ENGINEERING
SPECIFICATIONS.
UNIT NOTES IN INCHES [mm].
K
SIZE
3RD ANGLE
TITLE
DR.
D
SCALE
NTS
ROSEMOUNT 4088 IN-LINE
TYPE I DRAWING
J.ARMSTRONG
MB
APP'D
CAD MAINTAINED, (PRO/E)
12/10/13 DRAWING NO.
12/16/13
04088-6001
SHEET 1
OF
5
M
1
A
4
3
2
5
6
9
8
7
10
12
14
13
15
16
ROSEMOUNT 4088 IN-LINE PRESSURE TRANSMITTER
G 1/2 A DIN 16288 MALE PROCESS CONNECTION
A
STAINLESS STEEL PROCESS WETTED
B
11
PLANTWEB HOUSING
SHOWN WITH OPTIONAL DIGITAL DISPLAY
ALLOY C-276 PROCESS WETTED
PLANTWEB HOUSING
B
PLANTWEB HOUSING
5.17
[131]
CERTIFICATION LABEL
4.51
[115]
PRESSURE RANGE OPTION 1-4
CONDUIT CONNECTION
(2 PLACES)
C
C
D
D
TRANSMITTER
ELECTRONICS
(THIS SIDE)
FIELD TERMINALS
(THIS SIDE)
DIGITAL
DISPLAY
COVER
HOUSING
ROTATION
SET SCREW
E
8.76
[223]
E
NAMEPLATE
F
F
DIN
PLANTWEB HOUSING
PRESSURE RANGE OPTION 1-4
G
1.125
[29]
G
4.20
[107]
H
H
J
J
8.61
[219]
L
L
FORM REV AA
M
REFERENCE ROSEMOUNT
PRODUCT DATA SHEETS FOR
PRODUCT SPECIFICATIONS.
CLICK HERE
K
©2015 ROSEMOUNT INC.
ROSEMOUNT INC CERTIFIES
THESE DRAWINGS ARE IN
ACCORDANCE WITH
ROSEMOUNT ENGINEERING
SPECIFICATIONS.
UNIT NOTES IN INCHES [mm].
K
SIZE
3RD ANGLE
TITLE
DR.
D
SCALE
NTS
ROSEMOUNT 4088 IN-LINE
TYPE I DRAWING
J.ARMSTRONG
MB
APP'D
CAD MAINTAINED, (PRO/E)
12/10/13 DRAWING NO.
12/16/13
04088-6001
SHEET 2
OF
5
M
1
A
2
3
4
6
5
9
8
7
11
12
14
13
15
16
ROSEMOUNT 4088 IN-LINE PRESSURE TRANSMITTER
NON-THREADED INSTRUMENT FLANGE PROCESS CONNECTION
A
STAINLESS STEEL PROCESS WETTED
B
10
PLANTWEB HOUSING
SHOWN WITH OPTIONAL DIGITAL DISPLAY
ALLOY C-276 PROCESS WETTED
PLANTWEB HOUSING
B
PLANTWEB HOUSING
5.17
[131]
4.51
[115]
C
PRESSURE RANGE OPTION 1-4
CERTIFICATION LABEL
CONDUIT CONNECTION
(2 PLACES)
C
D
D
DIGITAL
DISPLAY
COVER
TRANSMITTER
ELECTRONICS
(THIS SIDE)
FIELD TERMINALS
(THIS SIDE)
E
8.17
[208]
E
HOUSING
ROTATION
SET SCREW
NAMEPLATE
F
G
F
INSTRUMENT FLANGE
G
PLANTWEB HOUSING
PRESSURE RANGE OPTION 1-4
4.20
[107]
H
H
J
J
K
8.02
[204]
K
L
REFERENCE ROSEMOUNT
PRODUCT DATA SHEETS FOR
PRODUCT SPECIFICATIONS.
CLICK HERE
FORM REV AA
M
©2015 ROSEMOUNT INC.
ROSEMOUNT INC CERTIFIES
THESE DRAWINGS ARE IN
ACCORDANCE WITH
ROSEMOUNT ENGINEERING
SPECIFICATIONS.
UNIT NOTES IN INCHES [mm].
L
SIZE
3RD ANGLE
TITLE
DR.
D
SCALE
NTS
ROSEMOUNT 4088 IN-LINE
TYPE I DRAWING
J.ARMSTRONG
MB
APP'D
CAD MAINTAINED, (PRO/E)
12/10/13 DRAWING NO.
12/16/13
04088-6001
SHEET 3
OF
5
M
1
A
3
2
4
6
5
9
8
7
10
11
12
14
13
15
16
ROSEMOUNT 4088 IN-LINE PRESSURE TRANSMITTER
AUTOCLAVE TYPE F-250-C COMPATIBLE PROCESS CONNECTION
A
ALLOY C-276 PROCESS WETTED
PLANTWEB HOUSING
STAINLESS STEEL PROCESS WETTED
B
PLANTWEB HOUSING
SHOWN WITH OPTIONAL DIGITAL DISPLAY
B
PRESSURE RANGE OPTION 5
PLANTWEB HOUSING
C
C
5.17
[131]
CERTIFICATION LABEL
4.51
[115]
CONDUIT CONNECTION
(2 PLACES)
D
D
E
TRANSMITTER
ELECTRONICS
(THIS SIDE)
FIELD TERMINALS
(THIS SIDE)
DIGITAL
DISPLAY
COVER
E
8.34
[212]
HOUSING
ROTATION
SET SCREW
F
F
NAMEPLATE
G
G
PLANTWEB HOUSING
PRESSURE RANGE OPTION 5
H
AUTOCLAVE TYPE
F-250-C
4.20
[107]
H
J
J
K
8.19
[208]
K
L
REFERENCE ROSEMOUNT
PRODUCT DATA SHEETS FOR
PRODUCT SPECIFICATIONS.
CLICK HERE
FORM REV AA
M
1.125
[29]
©2015 ROSEMOUNT INC.
ROSEMOUNT INC CERTIFIES
THESE DRAWINGS ARE IN
ACCORDANCE WITH
ROSEMOUNT ENGINEERING
SPECIFICATIONS.
UNIT NOTES IN INCHES [mm].
L
SIZE
3RD ANGLE
TITLE
DR.
D
SCALE
NTS
ROSEMOUNT 4088 IN-LINE
TYPE I DRAWING
J.ARMSTRONG
MB
APP'D
CAD MAINTAINED, (PRO/E)
12/10/13 DRAWING NO.
12/16/13
04088-6001
SHEET 4
OF
5
M
1
A
2
4
3
5
6
7
9
8
10
12
11
14
13
15
16
ROSEMOUNT 4088 IN-LINE PRESSURE TRANSMITTER
IN-LINE MOUNTING CONFIGURATIONS WITH OPTIONAL MOUNTING BRACKET
A
PANEL MOUNTING
PIPE MOUNTING
B
B
C
C
D
D
6.66
[169]
E
E
F
F
6.15
[156]
G
G
2.81
[71]
6.21
[157,6]
H
H
3.25
[83]
J
J
4.72
[120]
5/16-18 BOLTS
FOR PANEL MOUNTING
(NOT SUPPLIED)
K
2 INCH U-BOLT
FOR PIPE MOUNTING
(CLAMP SHOWN)
1 INCH U-BOLT
FOR TRANSMITTER MOUNTING
K
1 INCH U-BOLT
FOR TRANSMITTER MOUNTING
L
REFERENCE ROSEMOUNT
PRODUCT DATA SHEETS FOR
PRODUCT SPECIFICATIONS.
CLICK HERE
FORM REV AA
M
©2015 ROSEMOUNT INC.
ROSEMOUNT INC CERTIFIES
THESE DRAWINGS ARE IN
ACCORDANCE WITH
ROSEMOUNT ENGINEERING
SPECIFICATIONS.
UNIT NOTES IN INCHES [mm].
L
SIZE
3RD ANGLE
TITLE
DR.
D
SCALE
NTS
ROSEMOUNT 4088 IN-LINE
TYPE I DRAWING
J.ARMSTRONG
MB
APP'D
CAD MAINTAINED, (PRO/E)
12/10/13 DRAWING NO.
12/16/13
04088-6001
SHEET 5
OF
5
M