Product Data Sheet March 2014 00813-0100-5101, Rev AA Rosemount Tank Gauging Accessories for tank gauging systems Accessories for the Rosemount Tank Gauging system, including: Rosemount Segment Coupler Fieldbus Terminator Rosemount 2180 Field Bus Modem Rosemount 3180 Enraf Bus Mode Rosemount TankMaster I/O Terminals Rosemount Tank Gauging Accessories March 2014 Rosemount Segment Coupler Segment Coupler 2410 Tank Hub Rx Tx USB RS-232 Ext. pwr Rosemount TankRadar Lo - GAIN - Hi On - TERM - Off FBM 2180 Segment Coupler The 6-channel Tankbus Segment Coupler is designed for FOUNDATION™ fieldbus systems and is Entity and FISCO compliant. It includes adjustable spur short circuit protection and an integrated switchable bus termination. It is typically used as a junction box to distribute the Tankbus to multiple tanks and/or transmitters. The spur circuit protection maximum current limitation is selected for all channels via a rotary switch. Different current values, 30, 35, 45 and 60 mA, can be selected, which allows all Rosemount tank gauging devices to be connected and protected. Segment Coupler Segment Coupler Fieldbus Terminator 2410 Tank Hub A Fieldbus terminator is required at the end of the Tankbus. The external Fieldbus terminator eliminates signal reflections at the end of the cable and converts the fieldbus signal transmitted as a current into a voltage, which is detectable by all devices. There is no need for a separate bus terminator if a 2230, 2240S, or 5900S is the last device on the bus. Fieldbus Terminator Contents Ordering information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2 www.rosemount-tg.com March 2014 Rosemount Tank Gauging Accessories Rosemount 2180 Field Bus Modem The Rosemount 2180 Field Bus Modem is used for connecting a TankMaster PC to the TRL2 fieldbus. The modem is connected to the PC using either the RS232 or the USB interface. DCS / Host It has LEDs indicating power on and communication. There are front panel switches to set gain and termination, if required. Rx Tx Rosemount TankRadar USB TRL2 Modbus 2180 Modem RS-232 The field bus modem is delivered with cables for RS232 and USB connection. The USB cable also supplies power to the modem. A separately power supply cable (included in delivery) is only necessary for the RS232 option. 2160 Field Communication Unit Ext. pwr The modem is fitted on a standard DIN rail with the mounting kit included in all deliveries. Lo - GAIN - Hi On - TERM - Off FBM 2180 TankMaster PC Network Rosemount 3180 Enraf Bus Modem When an Enraf gauge is replaced with a Rosemount Radar Gauge using emulation, it is necessary to configure the Rosemount gauge for emulation. Configuration is made with the WinSetup software and requires a 3180 Enraf Bus Modem. How the procedure is done depends on the system type. USB or RS232 Modbus Entis / TankMaster PLC The 3180 Enraf Bus Modem can also be used to connect Enraf gauges directly to the TankMaster Inventory Software. 3180 Enraf Bus Modem CIU Laptop with WinSetup www.rosemount-tg.com 3 Rosemount Tank Gauging Accessories March 2014 Rosemount TankMaster I/O Terminals The I/O Terminals can be used for communication between the TankMaster Inventory Software and field equipment, for a more versatile system. The four versions are: TankMaster IOT 5110 IOT 5130 IOT 5120 IOT 5140 IOT 5110 for Analog Inputs IOT 5120 for Analog Outputs IOT 5130 for Digital Inputs IOT 5140 for Digital Outputs The analog inputs open up TankMaster for all 4-20 mA devices, such as pressure and temperature sensors. The analog outputs enable mapping of values to analog indicators. The digital inputs can for example be used to display alarms from external equipment in TankMaster. The digital outputs can be used for alarm panels, horns, signal lamps etc. The I/O terminals are complements to the TankMaster system, and are not designed to be used as stand-alone devices for critical operations. 4 www.rosemount-tg.com March 2014 Rosemount Tank Gauging Accessories Ordering information Rosemount Tankbus Segment Coupler Entity and FISCO compliant Adjustable spur short-circuit protection Robust die-cast aluminum housing Protection degree IP 67 Integrated bus termination Additional information Specifications: page 8 Dimensional drawings: page 13 Table 1. Rosemount Tankbus Segment Coupler ordering information Part Number Product Description 6853511-493 Tankbus segment coupler with integrated user-selectable on/off termination and spur short-circuit protection (max 60 mA/spur). Connections; trunk input, trunk output, 6 spurs M20x1,5. Wall-mounted, IP 67. Delivered with junction box. Entity and FISCO compliant. Fieldbus Terminator Prevents reflections/distortions Protection degree IP 67 Additional information Specifications: page 10 Dimensional drawings: page 13 Table 2. Fieldbus Terminator ordering information Part Number Product Description 6853511-494 Tankbus termination, external, ½ NPT male thread. Termination for external installation, mounted on a junction box or a transmitter field housing, IP 67. Entity and FISCO compliant. www.rosemount-tg.com 5 Rosemount Tank Gauging Accessories March 2014 Rosemount 2180 Field Bus Modem Increases the maximum possible distance between a Rosemount 2160 Field Communication Unit and a TankMaster PC Features diagnostic LEDs on front cover Enables multidrop - one TankMaster can communicate with several 2160 units Provides multiple mounting options Additional information Specifications: page 11 Dimensional drawings: page 14 Table 3. Rosemount 2180 Field Bus Modem ordering information Item No Product Description FBM 2180 TRL2 Fieldbus Modem Rosemount 3180 Enraf Bus Modem Enables configuration of a Rosemount Radar gauge for Enraf emulation Can connect Enraf gauges directly to the TankMaster Inventory software Each 3180 can be connected to up to 10 Enraf gauges Additional information Specifications: page 11 Dimensional drawings: page 14 Table 4. Rosemount 3180 Enraf Bus Modem ordering information Item No Product Description EBM 3180 Enraf Bus Modem 6 www.rosemount-tg.com March 2014 Rosemount Tank Gauging Accessories Rosemount TankMaster I/O terminals Modules for communication between TankMaster and field equipment Free mix of module types Up to 64 modules per loop 8 or 16 channels per module RS485 multi-drop bus connection 12-bit A/D- and D/A converter Flexible mounting – DIN or a choice with enclosure for ESP protection Additional information Specifications: page 12 Table 5. Rosemount TankMaster I/O ordering information Item No Product Description IOT 5110 AI(1) I/O Module Analog In, 16 channels IOT 5120 AO(1) I/O Module Analog Out, 16 channels IOT 5130 DI(1) I/O Module Digital In, 16 channels IOT 5140 DO(1) I/O Module Digital Out, 8 channels (1) Power supply (24 VDC) required, not included. TankMaster customized views option recommended for best functionality. Modules not designed for fail-safe usage. www.rosemount-tg.com 7 Rosemount Tank Gauging Accessories March 2014 Specifications Rosemount Tankbus Segment Coupler Table 6. Rosemount Tankbus Segment Coupler specifications General Electrical connection cable glands TRUNK IN 1 x M20 x 1.5 (Ø 6 to 13 mm), nickel-plated brass TRUNK OUT 1 x M20 x 1.5 (Ø 6 to 13 mm), nickel-plated brass Spur 6 x M20 x 1.5 (Ø 6 to 13 mm), nickel-plated brass Terminal cross-section 2.5 mm² Earthing bolt M5 x 1 Fieldbus standard IEC 61158-2 Operating voltage range 12 to 32 VDC Current self-consumption 7 mA Voltage drop 0.3 V Short-circuit protection 30, 35, 45, 60 mA Ex approval according to conformity certificate PTB 03 ATEX 2236 Entity Parameter Max. output voltage Uo 24 V Max. output current Io 250 mA Max. output power Po 2560 mW Max. input voltage Ui 24 V Max. input current Ii 250 mA Max. input power Pi 2560 mW FISCO parameter acc. to IEC TS 60079-27 Max. output voltage Uo 17.5 V Max. output current Io 380 mA Max. output power Po 5320 mW Max. input voltage Ui 17.5 V Max. input current Ii 380 mA Max. input power Pi 5320 mW External inductance / capacitance Li /Ci trunk (in/out): negligible / 5.00 nF per field current circuit: negligible / 0.47 nF field current circuits: negligible / 5.00 nF Device designation: II 2 G Ex ib IIC/IIB T4 II 2(1) G Ex ia IIC/IIB T4 II 2 G (2D) [Ex ibD] Ex ib IIB T4 II 2 (1) G (1D)[Ex iaD] Ex ia IIB T4 FISCO / Entity field device IP 67 MTTF 117 years acc. to SN 29500 (Ed. 99) 40 °C Ambient temperature -25 to +70 °C (-13 to +158 °F) Protection class Housing material Powder-coated die-cast aluminum Housing color Black / blue RAL 5015 Connection mode Wall mounting with nickel plated brass cable glands 8 www.rosemount-tg.com March 2014 Rosemount Tank Gauging Accessories Figure 1. Segment Coupler, connections 5400 Level Transmitter Trunk OUT S0 Trunk IN P1 Spur S1 Spur S2 Spur S3 Spur S4 Spur S5 Spur S6 644 Temperature Transmitter 5400 Level Transmitter 2410 Tank Hub Tankbus (trunk) Case ground (Spur <60m) (Spur <60m) Segment coupler 2230 Display Tankbus (trunk) 2240S Temperature Transmitter 5900S Radar Level Gauge www.rosemount-tg.com 9 Rosemount Tank Gauging Accessories March 2014 Fieldbus Terminator Table 7. Fieldbus Terminator specifications Fieldbus Interface Connection 2-wire cable, red+, black- Rated voltage 32 V DC Ambient conditions Ambient temperature -50 to + 85 °C (-58 to +185 °F) Storage temperature -50 to + 85 °C (-58 to +185 °F) Mechanical specifications Core cross-section 0.75 mm² Protection degree IP 67 Weight 100 g (0.2 lb) Mounting ½ NPT thread Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2006 Standard conformity Electromagnetic compatibility NE 21:2006 Protection degree IEC/EN 60529 Fieldbus standard IEC 61158-2 Hazardous Location Certifications EC-Type Examination Certificate Group, category, type of protection, temperature class DMT 01 ATEX 104 X II 1 G EEx ia IIC T6 Directive conformity Directive 94/9/EC EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2007, IEC 60079-27:2008 International approvals IECEx approval IECEx BVS 10.0022X Approved for Ex ia IIC T6 Ga Hazardous Location Data Temperature class T6 for ambient temperatures: 60 °C T5 for ambient temperatures: 75 °C T4 for ambient temperatures: 85 °C Voltage Ui 30 V Rated voltage 30 V 10 www.rosemount-tg.com March 2014 Rosemount Tank Gauging Accessories Rosemount 2180 Field Bus Modem Table 8. Rosemount 2180 Field Bus Modem specifications General Protocol Modbus Baudrate 4800 Explosion protection None Power supply (only used for RS232) AC/DC converter supplied (7-12 V, 50 mA) Cable to PC RS232: 3 m (10 ft) USB: 3 m (10 ft) Included in delivery Fieldbus over-voltage protection Galvanic insulation, and transient suppressors Ambient temperature 0 to + 55 °C (0 to +130 °F) Rosemount 3180 Field Bus Modem (Enraf) Table 9. Rosemount 3180 Field Bus Modem (Enraf) specifications General Protocol Modbus/Enraf GPU Baudrate 2400/1200 Compatible with Enraf devices with GPU protocol Explosion protection None Power supply 9 VDC (AC/DC converter included) Cable to PC RS232 Signal gain control via internal jumpers Ambient temperature www.rosemount-tg.com •10% (default) •35% •100% 0 to + 55 °C (0 to +130 °F) 11 Rosemount Tank Gauging Accessories March 2014 Rosemount TankMaster I/O Terminals Table 10. Rosemount TankMaster I/O Terminals specifications Technical data for TankMaster IOT 5110-5140 Communication type RS485 Communication speed 115 kbit/s Isolation Opto-coupled (in I/O box) Dimensions 160x100x80 mm (6.3x3.9x3.2 in.) Mounting method DIN rail 35 mm (1.4 in.) clip Supply voltage 24 VDC Ambient temperature 0 to + 55 °C (0 to +130 °F) IOT 5110 Analog In; 4-20 mA, 0-10 V Channels 16 single ended Input load 50 (current), 10 k (voltage) Accuracy (current and voltage) Max ±0.5% of full range Temperature drift (current and voltage) Accuracy valid for 0 to +55 °C (0 to +130 °F) IOT 5120 Analog Out; 4-20 mA, 0-10 V Channels 16 single ended Load impedance 50 / max 500 Load current < 5 mA for 0-10 VDC Accuracy (current) Max ±0.5% of full range Accuracy (voltage) Max ±0.2% of full range Temperature drift (current and voltage) Accuracy valid for 0 to +55 °C (0 to +130 °F) IOT 5130 Digital In Channels 16 negative common Voltage range input 0 to +35 VDC Source type Potential free contact Input current Max 0.6 mA IOT 5140 Digital Out Channels 8 pot free SPDT Capacity Max 250 VAC, 2 A 12 www.rosemount-tg.com March 2014 Rosemount Tank Gauging Accessories Dimensional drawings Rosemount Segment Coupler Figure 2. Rosemount Segment Coupler dimensions 122 (4.8) 64 (2.5) 36 (1.4) 207 (8.1) 173,5 (6.8) 185,5 (7.3) 45 (1.8) Note Dimensions are in millimeters (inches). Fieldbus Terminator Figure 3. Fieldbus Terminator dimensions 1 22 (0.9) 2 55 (2.2) 22 (0.9) 1. Cable cross sectional area 1.0 mm (0.04 in.) Cable length min. 290 mm (11.4 in.) 2. FN: ½” NPT thread Note Dimensions are in millimeters (inches). www.rosemount-tg.com 13 Rosemount Tank Gauging Accessories March 2014 Rosemount 2180 Field Bus Modem Figure 4. Rosemount 2180 Field Bus Modem dimensions Connection to fieldbus (via Rosemount 2160/2165/2175 or Rosemount 2410) Rx Tx DC IN USB RS-232 Ext. pwr Connection to PC Lo - GAIN - Hi On - TERM - Off RS-232 USB Shield|Bus|Bus|Gnd FIELD BUS ±7-12V 50mA ROSEMOUNT 2180 Only for Field Bus Modem RS-232 Made in Operation Part No. 9240002-635 X Sweden Rosemount 2180 Field Bus Modem 114 (4.5) Note Dimensions are in millimeters (inches). 109 (4.3) Rosemount 3180 Enraf Bus Modem Figure 5. Rosemount 3180 Enraf Bus Modem dimensions Field Bus Field Bus: Pin 4,6 EBM 3180 PC-modem Shield: Pin5 Tank Gauging 114(4.5) Rosemount Tank Radar AB Gothenburg, Sweden External DC Power Supply 8-12V, 60mA Modbus (4800 baud) Normal (GPU) Pos+ Note Dimensions are in millimeters (inches). 14 MADE IN SWEDEN 2400 baud 1200 baud Computer RS 232 Neg- 109(4.3) www.rosemount-tg.com March 2014 www.rosemount-tg.com Rosemount Tank Gauging Accessories 15 Rosemount Tank Gauging Accessories 00813-0100-5101, Rev AA Product Data Sheet March 2014 Emerson Process Management Rosemount Tank Gauging Emerson Process Management Rosemount Tank Gauging North America Inc. Emerson Process Management Latin America Box 130 45 SE-402 51 Göteborg SWEDEN Tel: +46 31 337 00 00 Fax: +46 31 25 30 22 E-mail: [email protected] www.rosemount-tg.com 6005 Rogerdale Road Mail Stop NC 136 77072 TX Houston United States Primary Phone: +1 281 988 4000 Secondary Phone: +1 800 722 2865 E-mail: [email protected] 1300 Concord Terrace, Suite 400 Sunrise Florida 33323 United States Tel: +1 954 846 5030 Emerson Process Management Rosemount Tank Gauging Middle East & Africa. Emerson Process Management Asia Pacific Pte Ltd P. O Box 20048 Manama Bahrain Tel: +973 1722 6610 Fax: +973 1722 7771 E-mail: [email protected] 1 Pandan Crescent SINGAPORE 128461 Tel: +65 6777 8211 Fax: +65 6777 0947 Email: [email protected] The Emerson logo is a trade mark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. PlantWeb is a registered trademark of one of the Emerson Process Management group of companies. HART and WirelessHART are registered trademarks of the HART Communication Foundation All other marks are the property of their respective owners. © 2014 Rosemount Tank Radar AB. All rights reserved.
© Copyright 2026 Paperzz