Community Development & Neighborhood Services 281 N. College Ave., P.O. Box 580; Fort Collins, CO 80522; Voice: 970 221 6760 RESIDENTIAL SUNSHADE HANDOUT - 2012 IRC REVISED 10/6/15 PERMITS ARE REQUIRED FOR SUNSHADE'S. EXISTING HOUSE TOP LATTICE IS OPTIONAL HOWEVER IF INSTALLED MUST BE SPACED FAR ENOUGH APART TO ALLOW SNOW THROUGH, 3" MIN OR 2X THE MEMBER SIZE (WHICH EVER IS GREATER). RAFTER PER CHART #1 10'-0" 11'-0" LEDGER BOARD, SEE SAMPLES BEAM PER CHART #2 12'-0" 14'-0" PLAN VIEW, SCALE: 1/4"= 1'-0" GAP BETWEEN LATTICE= 2X THE MEMBER SIZE OR 3" (WHICH EVER IS GREATER). 3" CONTINUOUS FLASHING OVER LEDGER BOARD JOIST HANGER JOIST TO BEAM METAL CONNECTOR 2- 3 8" THRU BOLT BEAM ATTACHEMENT TO POST OR OTHER APPROVED BEAM DETAIL. REMOVE SIDING AND LAG LEDGER BOARD TO WALL STUDS POST (2) 3 8x3 1 2" LAG SCREWS EVERY 16" O.C. RAFTER TO BEAM & LEDGER BOARD DETAIL 4x4 POST. PRESSURE TREATED OR REDWOOD IF TOUCHING CONCRETE. 110'-0" PROPERTY LINE SCALE 1"=20' 16' PERGOLA 10' GARAGE SAMPLE SITE PLAN 60'-0" PROPERTY LINE HOUSE 15'-0" 60'-0" PROPERTY LINE 424 MAIN ST. NORTH 29'-0" 110'-0" PROPERTY LINE 30'-0"