आग की रोकथाम और औद्योगिक सुरक्षा में प्रमाणपत्र (626) (114 KB)

FIRE PREVENTION & INDUSTRIAL SAFETY (626)
The institution having the following requisite infrastructure, may apply for accreditation:
A.
Class Room: Classroom for 30 students (minimum area 400Sq. ft.) should have
proper ventilation, well-illuminated black board/white board and availability of
adequate furniture and ceiling fan.
B.
Exhibit: Minimum Size – 600 Sq. Ft. preferably display racks etc. well ventilated and
illuminated)
C.
Field: Field should have capacity to accommodate minimum 50 students for P. T.
Practical Training etc.




S. No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Fixed system
Protable system
Small gears
Other
List of Tools /Equipment required for Practical/Training
Name of the Equipment
Co2 Extinguishers
Water Co2 Extinguishers
Mechanical Foam Extinguishers
5 Kg. Pressurized DCP Extinguishers
S. No.
23.
24.
25.
26.
10 Kg. DCP Extinguishers
ABC Type Dry Chemical Powder Fire
Extinguished stored pressure
Co2 Gas cartridges
Fire Trays (instantaneous)
Male Coupling (instantaneous)
Female coupling (instantaneous)
Nozzle
Short Branch (copper)
Short Branch (Brass Metal)
Long Ordinary Branch
London Pattern Hand Control Branch
Triple Purpose branch
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
17. Ordinary Hand Control Branch
39.
18. Fog Branch
19. Diffuser Branch
20. Revolving Branch
40.
41.
42.
21. waster Cutter (Mayur)
43.
(Copper)
Name of the Equipment
New Light Nozzle (Fog Type)
Male o Male Adopter
Suction Adopter
Dividing Breaching Collecting
Breaching
Two way collecting wade
Suction Coupling
Metal Strainer
Basket Strainer
Suction Wrench (Universal)
Suction Wrench (Conventional)
Rubber Line Hose
Reinforce Rubber Line Hose
Suction Pipe 4
Suction pipe (PVC) 3 diameter
B.A. Set Cylinders
Fire Switch Alarm with
hammer
Bolt Cutter
Large Axe, Ordinary Axe
Firemen Axe (Wooden)
Firemen Axe (Insulated Rubber
Volt testing 2000 to 25000)
Gum Boot
22. Fast Active Nozzle (Fog Type)
44.
Salvage Sheet
Pickup tube
Connecting tube
Safety Helmet
Shovel
Spade
Tagari
Crow bar
Fire Bucket
First Aid Box
Manual Call Point
Mechanical Foam 20 kg. jerry
DCP powder
Aluminum Fire suti
Overall (Dangri)
Smoke Detector
Fire Alam Control Panel
Smoke Chamber
Drill Tower (Multistoried
Tower (Multistoried for Rescue
work)
Fire Hydrants (Water Source)
Sprinkler
Hand Control Siren
Trailer Pump
Hose reel, Hose & one Hose box
Fire Foam Tender
45.
46.
47.
48.
49.
50.
51.
52.
53.
54
55.
56.
57.
58.
59.
60.
61.
62.
Life Jacket
Life Boa
Rubber Gloves
Asbestos Gloves
Ear Mutt
Hopper
Hammer
Mattock
Oxi-Jinger (cat style)
Wrench (related to Extinguisher tools)
Rope ladder
35” feet Aluminum extension Ladder
Synthetic Rope
Manila Rope
Wire Rope (Metal)
Safety Belt (Harness)
Net (for rescue)
Nep Senk tank
70
71.
72.
73.
74.
75.
76.
77.
78.
79.
80.
81.
82.
83.
84.
85.
86.
87.
63.
64.
65.
66.
67.
68.
69.
Low Pressure Applicator Branch
F.B. 2 Branch
F.B. 5 x Branch
F.B. 10 Branch
F.B. 10 with pickup tube Branch
M.F.G 5 Branch
Inline Inductor (for foam making)
88.
89.
90.
91.
92.
93.
D.
Physical Facilities: The institutions should have the facilities for drinking water,
bathrooms & toilets.
E.
Library: Library should have a minimum 10 books/articles/magazines etc. related
subject.
F.
Faculty & Supporting Staff:
Faculty & Supporting Staff
Educational/Professional Qualification
Coordinator
Educated/Professional
Instructor (theory)
Diploma in Fire engineering
Instructor (practical
training )
Receptionist cum clerk
G.
Or
Fireman certificate course with 1 year experience)
Or
Certificate
Relevant to job
Batch size – Maximum 30 students in one batch.
01
02
01
No.
Note : Institute can run maximum 2 batches of this course