Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV This chapter provides information about field upgrades for both software and hardware components and describes how to remove and replace the field-replaceable units (FRUs) in the Cisco uBR Advanced RF Switch (Cisco UBR-RFSW-ADV). • Field Upgrades, page 1 • How to Remove and Install the FRUs, page 2 Field Upgrades The Cisco UBR-RFSW-ADV supports field upgrades for both the operating software image and FRUs. It handles system management of field upgrades, like hot swapping cards and micro-controller images. The Cisco uBR10012 router initiates image download and facilitates access to the Cisco UBR-RFSW-ADV. Software Upgrades The Cisco UBR-RFSW-ADV supports online software image upgrades. The operating state (failover, pass-through) is not changed during the download or upgrade process. The interface between the controller card and the Cisco uBR10012 router via the RS-232 interface is functional during the image upgrade process. Hardware Upgrades All FRUs in the system are field-upgradable. The Cisco UBR-RFSW-ADV is responsible for managing all image updates to the individual system cards. All cards support hot-swapping. The following FRUs are present in the Cisco UBR-RFSW-ADV: • Upstream switch cards • Upstream protect cards • Upstream interconnect cards • Downstream switch cards Cisco uBR Advanced RF Switch Hardware Installation Guide OL-24104-01 1 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV How to Remove and Install the FRUs • Downstream protect cards • Downstream interconnect cards • Power supply • Controller card Note See the "Preparing for the Cisco UBR-RFSW-ADV Installation" section for information on safety and electrostatic discharge damage (ESD). Also see the Regulatory Compliance and Safety Information for the Cisco Next Generation RF Switch for a list of translated warnings. How to Remove and Install the FRUs This section describes the removal and installation of the FRUs. Removing the Switch and Interconnect Cards Caution Ensure that you are grounded using an ESD-preventive wrist or ankle strap. Before You Begin Have the following tools handy while performing this task: • #2 Phillips screw driver • Slotted screw driver • Card extraction/insertion tool Procedure Step 1 Remove the UCH2. See Figure 1: Removing the UCH2, on page 3. 1 Loosen the lead screw (counter-clockwise) on the UCH2 until it is completely disengaged from the faceplate. 2 Pull the UCH2 straight away from the faceplate using the lead screw. Cisco uBR Advanced RF Switch Hardware Installation Guide 2 OL-24104-01 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Removing the Switch and Interconnect Cards Caution Do not use the cables to pull the UCH2 from the faceplate. Figure 1: Removing the UCH2 Step 2 Remove the switch card. 1 Use the card extraction/insertion tool as shown in Figure 2: Using the Card Extraction/Insertion Tool, on page 4. 2 Using a #2 phillips or a slotted screwdriver, loosen the top and bottom captive screws on the card. Cisco uBR Advanced RF Switch Hardware Installation Guide OL-24104-01 3 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Removing the Switch and Interconnect Cards 3 Grasp the upper handle on the card and slide the card out of the slot (Figure 3: Removing the Switch Card from the Cisco UBR-RFSW-ADV Chassis, on page 4). Place it on an antistatic surface with the component side facing up. Figure 2: Using the Card Extraction/Insertion Tool Figure 3: Removing the Switch Card from the Cisco UBR-RFSW-ADV Chassis Cisco uBR Advanced RF Switch Hardware Installation Guide 4 OL-24104-01 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Installing the Switch and Interconnect Cards Caution Tip Handle the card from the faceplate or the card edges only. Be careful while sliding the switch card out so as not to damage the relays on the card. In an upstream-only Cisco UBR-RFSW-ADV, always install a blank cover in an empty slot to ensure proper cooling and airflow. Installing the Switch and Interconnect Cards Caution Use both hands when handling the card. Do not drop the card. Handle the card from the faceplate or the card edges only. Caution Ensure that you are grounded using an ESD-preventive wrist or ankle strap. Before You Begin Have the following tools handy while performing this task: Cisco uBR Advanced RF Switch Hardware Installation Guide OL-24104-01 5 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Installing the Switch and Interconnect Cards • #2 Phillips screw driver • Slotted screw driver • Card extraction/insertion tool Procedure Step 1 Step 2 Step 3 Attach the card extraction/insertion tool to the card. See Figure 2: Using the Card Extraction/Insertion Tool, on page 4. Grasp the upper handle on the faceplate with one hand and hold the base of the card faceplate with your other hand. Align the upper and lower edges of the card with the upper and lower guides on the chassis. See the figure below. Figure 4: Inserting the Switch Card into the Cisco UBR-RFSW-ADV Chassis Cisco uBR Advanced RF Switch Hardware Installation Guide 6 OL-24104-01 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Removing the Power Supply Module Step 4 Step 5 Step 6 Slide the card into the slot until you feel it seat in the backplane connectors. Push on the card extraction/insertion tool to fully seat the card in the backplane connectors. Engage and begin tightening the captive screws. Use either the #2 phillips or a slotted screwdriver to tighten the captive screws between 5 to 8 in-lbs. Caution Tighten the captive screws only to a maximum of 8 in-lbs. Tip Ensure that the captive screws are secure for proper electromagnetic interference (EMI) shielding. Step 7 Remove the card extraction/insertion tool from the card. What to Do Next Go to Connecting the RF Cables From the Working and Protect Line Cards to the Cisco UBR-RFSW-ADV. Removing the Power Supply Module Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Statement 1034. Before You Begin Have the following tool ready before performing this task: • #2 Phillips slotted screwdriver Cisco uBR Advanced RF Switch Hardware Installation Guide OL-24104-01 7 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Removing the Power Supply Module Procedure Step 1 Step 2 Step 3 Step 4 Ensure that the power is switched off from the facility to the Cisco UBR-RFSW-ADV, and no LED is illuminated on the Cisco UBR-RFSW-ADV. Disconnect the power supply cables from the power supply module. Using a #2 Phillips or a slotted screwdriver, loosen the top and bottom captive screws on the power supply module. See the figure below. Grasp the upper and lower handles on the power supply and slide it out of the slot and place it on an antistatic surface with the component side facing up. Figure 5: Removing the Power Supply Module from the Cisco UBR-RFSW-ADV Chassis Cisco uBR Advanced RF Switch Hardware Installation Guide 8 OL-24104-01 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Installing the Power Supply Module Installing the Power Supply Module Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing.Statement 1034. Caution Ensure that the power is switched off from the facility to the Cisco UBR-RFSW-ADV, and no LED is illuminated on the Cisco UBR-RFSW-ADV. Before You Begin Have the following tool ready before performing this task: • #2 Phillips slotted screwdriver Cisco uBR Advanced RF Switch Hardware Installation Guide OL-24104-01 9 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Installing the Power Supply Module Procedure Step 1 Step 2 Grasp the upper and lower handles on the power supply. Align the upper and lower edges of the power supply with the upper and lower guides on the chassis. See the figure below. Figure 6: Inserting the Power Supply Module into the Cisco UBR-RFSW-ADV Chassis Step 3 Step 4 Slide the power supply module into the slot until you feel it seat. Engage and begin tightening the captive screws. Use either a #2 phillips or a slotted screwdriver to tighten the captive screws. Caution Tighten the captive screws only to a maximum of 8 in-lbs. Cisco uBR Advanced RF Switch Hardware Installation Guide 10 OL-24104-01 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Removing the Controller Card Removing the Controller Card Caution Ensure that you are grounded using an ESD-preventive wrist or ankle strap. Before You Begin Have the following tool ready while performing this task: • #2 Phillips slotted screwdriver Procedure Step 1 Disconnect the RS-232 cable from the RJ-45 ports on the controller card. See the following figure. Figure 7: Disconnecting the RS-232 Cable from the RJ-45 Ports 1 RS-232 cables Step 2 Step 3 2 RJ-45 ports Using a #2 Phillips slotted screwdriver, loosen the top and bottom captive screws on the controller card. Grasp the upper and lower handles on the controller card and slide it out of the slot and place it on an antistatic surface with the component side facing up. Cisco uBR Advanced RF Switch Hardware Installation Guide OL-24104-01 11 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Installing the Controller Card Installing the Controller Card Caution Ensure that you are grounded using an ESD-preventive wrist or ankle strap. Before You Begin Have the following tool ready while performing this task: • #2 Phillips slotted screwdriver Cisco uBR Advanced RF Switch Hardware Installation Guide 12 OL-24104-01 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Installing the Controller Card Procedure Step 1 Step 2 Grasp the upper and lower handles on the controller card. Align the upper and lower edges of the controller card with the upper and lower guides on the chassis. See the following figure. Figure 8: Inserting the Controller Card into the Cisco UBR-RFSW-ADV Chassis Step 3 Step 4 Slide the controller card into the slot until you feel it seat. Engage and begin tightening the captive screws. Use either a #2 Phillips or a slotted screwdriver to tighten the captive screws. Caution Tighten the captive screws only to a maximum of 8 in-lbs. Cisco uBR Advanced RF Switch Hardware Installation Guide OL-24104-01 13 Removing and Replacing the Hardware Components in Cisco UBR-RFSW-ADV Installing the Controller Card What to Do Next Go to Connecting the PRE With the Controller Card. Cisco uBR Advanced RF Switch Hardware Installation Guide 14 OL-24104-01
© Copyright 2026 Paperzz