Technical Specifications This appendix provides the technical specification for the Cisco IE 4000 switches. Operating Temperature Specifications Table 3 on page 59 lists the operating temperatures for the Cisco IE 4000 switches in three different environments. Table 3 Enclosure types Operating Temperature for the Cisco IE 4000 Switches Industrial Automation and Hazardous Locations Substation Traffic Signal Sealed enclosures Vented enclosures Fan or blower-equipped enclosures For example: NEMA4, NEMA4X, NEMA12, NEMA13, IP54, and IP66. For example: NEMA1, IP20, and IP21. For example: NEMA TS-2. Note: The minimum airflow is 150 lfm1. 1. lfm = linear feet per minute. Note: The safety certifications apply only to ambient temperatures under 158°F (70°C). However, the Cisco IE 4000 switch can function in the substation and traffic signal installations under the environmental conditions shown in Table 3 on page 59. Cisco Systems, Inc. 59 www.cisco.com Technical Specifications Technical Specifications Technical Specifications The technical specifications for the Cisco IE 4000 switches are as follows: Table 4 Cisco IE 4000 Technical Specifications Environmental Ranges Storage temperature Operating temperature –40 to 185°F (–40 to 85°C) 1 -40C to +74C -40C to +70C (Vented Enclosure Operating) -40C to +60C (Sealed Enclosure Operating) -34C to +74C (100LFM or more Fan or Blower equipped Enclosure Operating) -40C to +85C (Type Tested to +85C for 16 hours) 2 Note: If the unit is powered on at subzero temperatures it could take up to 12 minutes to complete the booting process. This is due to the internal heaters that heat up the devices to safe operating temperature. Operating humidity 5 to 95% (noncondensing) Operating shock 30 g at 11 ms, and 200 g at 2.11 ms. Operating altitude Up to 13,000 ft (3962 m) Storage altitude Up to 40,000 ft (12,192 m) Power Requirements DC input voltage Maximum operating range: 9.6 to 60 VDC Nominal: 12, 24, or 48 VDC Note: The DC-input power supply is an SELV circuit, and it can only be connected to another SELV circuit. Input voltage for power supplies: — To power the switch, PWR-IE50W-AC-IEC and PWR-IE50W-AC provide 24 VDC at 2.1 A. — To support PoE, power supplies PWR-IE65W-PC-AC and PWR-IE65W-PC-DC provide 54 VDC at 1.2 A. PoE mode vs PoE+ input voltages — PoE mode: 48 VDC (nominal)/44-57 VDC (absolute range) — PoE+ mode: 54 VDC (nominal)/50-57 VDC (absolute range) 60 Technical Specifications Technical Specifications Table 4 Cisco IE 4000 Technical Specifications Power consumption3 35 W IE-4000-4T4P4G-E IE-4000-8T4G-E IE-4000-8GT4G-E IE-4000-16T4G-E 40W IE-4000-4GC4GP4G-E IE-4000-4TC4G-E IE-4000-4S8P4G-E IE-4000-4GS8GP4G-E IE-4000-16GT4G-E: 42W IE-4000-8S4G-E IE-4000-8GS4G-E Physical Dimensions Weight Dimensions4 (H x W x D) Including DIN Rail All IE4000 models listed in Table 1: 6.35 pounds (2.88 kg) PWR-IE170W-PC-AC=: 3.88 pounds (1.76 kg) PWR-IE170W-PC-DC=: 3.7 pounds (1.67 kg) PWR-IE50W-AC=: 1.4 lb (0.65 kg) PWR-IE50W-AC-IEC=: 1.4 lb (0.65 kg) PWR-IE65W-PC-DC=: 2.6 (1.18 Kg) PWR-IE65W-PC-AC=: 2.7 (1.24 Kg) All IE 4000 models have the following dimensions: 6.12 x 6.12 x 5.09 in. (155.4 x 155.4 x 129.2 mm) PWR-IE170W-PC-AC=: 5.93 x 3.72 x 5.60 in. (150.6 x 94.5 x 142.2) PWR-IE170W-PC-DC=: 5.93 x 4.47 x 5.75 in. (150.6 x 113.5 x 145.8) PWR-IE50W-AC=: 5.8 x 2.0 x 4.4 in. (147 x 51 x 112 mm) PWR-IE50W-AC-IEC=: 5.8 x 2.0 x 4.4 in. (147 x 51 x 112 mm) PWR-IE65W-PC-AC=: 5.9 x 2.6 x 4.6 in. (150 x 66 x 117 mm) PWR-IE65W-PC-DC=: 5.9 x 2.6 x 4.6 in. (150 x 66 x 117 mm) 1. Operating temperatures exceeding 60C are not covered by the product safety certifications and approvals. However, the switch can function in the installations under the environmental conditions listed. 2. The maximum operating temperature of the switch varies depending on the type of SFP module that you use. 3. Power Consumption numbers are measured at 9.6V and do not include PoE power consumption 61 Technical Specifications Alarm Ratings 4. To calculate the depth excluding the rail, subtract 0.22 in. (0.6 cm). Alarm Ratings The alarm ratings for the Cisco IE 4000 switches are below. Table 5 Cisco IE 4000 Alarm Ratings Alarm Ratings Specification Alarm input electrical specification No power required—open or closed state detected. Alarm output electrical specification 1.0 A @ 24 VDC or 0.5 A @ 48 VDC 62
© Copyright 2026 Paperzz