Monitoring the Cisco cBR Chassis Monitoring the Cisco cBR Chassis 2 Monitoring the Cisco cBR Chassis Using CLI 2 Revised: May 28, 2015, Monitoring the Cisco cBR Chassis Monitoring the Cisco cBR Chassis Using CLI • show platform—Verify if the installed cards are in Ok or Inserted state. Router# show platform Chassis type: CBR-8-CCAP-CHASS Slot --------1 1/1 SUP0 R0 F0 4 4/1 P0 P1 P2 P3 P4 P5 P10 P11 P12 P13 P14 Type ------------------CBR-CCAP-LC-40G CBR-RF-PIC CBR-CCAP-SUP-160G CBR-SUP-8X10G-PIC PWR-2KW-DC-V2 PWR-2KW-DC-V2 PWR-2KW-DC-V2 PWR-2KW-DC-V2 PWR-2KW-DC-V2 PWR-2KW-DC-V2 CBR-FAN-ASSEMBLY CBR-FAN-ASSEMBLY CBR-FAN-ASSEMBLY CBR-FAN-ASSEMBLY CBR-FAN-ASSEMBLY State --------------------ok ok inserted ok, active ok, active ok, active ok ok ok ok ok ok ok ok ok ok ok ok Insert time (ago) ----------------03:22:58 03:19:40 03:22:58 03:20:30 03:21:20 03:21:20 03:21:20 03:21:20 03:21:20 03:21:20 03:21:10 03:21:10 03:21:10 03:21:10 03:21:10 • show platform hardware slot slot serdes status—Verify if all the links are in locked state. Router# show platform hardware slot F1 serdes status Slot R1-Link A RX link locked 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 3-Link A RX link locked 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link A RX link locked 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link B RX link locked 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link C RX link locked 2 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link D RX link locked 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link E RX link Init 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link F RX link Init 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link G RX link Init 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes Slot 5-Link H RX link Init 58-bit scrambler, 20 Gbps 0 Overruns, 0 Underruns 0 Reframe, 0 Disparity 0 Out of band, 0 Illegal control codes • show environment all—Verify the environmental status of each FRU after installation. This command displays the system temperature, voltage, fan, and power supply conditions. Router# show environment all Sensor List: Environmental Monitoring Sensor Location State AVCC&1P2: Sens 4/1 Normal AVCC&1P2: Vin 4/1 Normal AVCC&1P2: ADin 4/1 Normal VP1P35: Sens 4/1 Normal VP1P35: Vin 4/1 Normal VP1P35: ADin 4/1 Normal VP1P0: Sens 4/1 Normal VP1P0: Vin 4/1 Normal VP1P0: ADin 4/1 Normal MGTAVTT: Sens 4/1 Normal MGTAVTT: Vin 4/1 Normal MGTAVTT: ADin 4/1 Normal VP1P8: Sens 4/1 Normal VP1P8: Vin 4/1 Normal VP1P8: ADin 4/1 Normal VP3P3: Sens 4/1 Normal VP3P3: Vin 4/1 Normal VP3P3: ADin 4/1 Normal Temp: RTMAC 4/1 Normal Temp: INLET 4/1 Normal Temp: OUTLET 4/1 Normal Temp: MAX6697 4/1 Normal Temp: TCXO 4/1 Normal Temp: SUP_OUT 4/1 Normal Reading 81 mV 12600 mV 0 mV 8 mV 12650 mV 112 mV 15 mV 12625 mV 0 mV 21 mV 12625 mV 0 mV 41 mV 12600 mV 0 mV 39 mV 12625 mV 0 mV 34 Celsius 29 Celsius 27 Celsius 50 Celsius 37 Celsius 49 Celsius 3 Temp: 3882_1 P Temp: 3882_2 P Temp: 3882_3 P VP5P0: Sens VP5P0: Vin VP5P0: ADin VP1P8: Sens VP1P8: Vin VP1P8: ADin 3P3&1P0: Sens 3P3&1P0: Vin 3P3&1P0: ADin Temp: INLET PD Temp: OUTLETPD Temp: 6697-DC Temp: PHYOUT Temp: PHYIN Temp: SSD Temp: SFP+ Temp: 3882_1PD 3882_PC1_0: VO 3882_PC1_1: VO 3882_PC2_0: VO 3882_PC3_0: VO PSOC-PC1_0: VO PSOC-PC1_1: VO PSOC-PC1_2: VO PSOC-PC1_3: VO PSOC-PC1_4: VO PSOC-PC1_5: VO PSOC-PC1_6: VO PSOC-PC1_7: VO PSOC-PC1_8: VO PSOC-PC1_9: VO PSOC-PC1_10: V PSOC-PC1_11: V PSOC-PC1_12: V PSOC-PC1_13: V PSOC-PC1_14: V PSOC-PC1_15: V 3882_PDC_0: VO 3882_PDC_1: VO PSOC-DC1_0: VO PSOC-DC1_1: VO PSOC-DC1_2: VO PSOC-DC1_3: VO PSOC-DC1_4: VO 12_CUR: Sens 12_CUR: Vin 12_CUR: ADin G0_CUR: Sens G0_CUR: Vin G0_CUR: ADin G1_CUR: Sens G1_CUR: Vin G1_CUR: ADin LB_CUR: Sens LB_CUR: Vin LB_CUR: ADin Temp: CAPRICA Temp: BASESTAR Temp: RAIDER Temp: CPU Temp: INLET Temp: OUTLET Temp: DIGITAL Temp: UPX Temp: LEOBEN1 Temp: LEOBEN2 Temp: 3.3-18 Temp: BS_1V Freq: 5338-49 Freq: 5338-52 4 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 4/1 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal 44 Celsius 39 Celsius 39 Celsius 6 mV 12650 mV 0 mV 33 mV 12625 mV 0 mV 24 mV 12625 mV 0 mV 27 Celsius 36 Celsius 38 Celsius 49 Celsius 38 Celsius 40 Celsius 36 Celsius 42 Celsius 1198 mV 999 mV 998 mV 1349 mV 3300 mV 12590 mV 6997 mV 5000 mV 3299 mV 1000 mV 1010 mV 1801 mV 2000 mV 1198 mV 1798 mV 2500 mV 1353 mV 1223 mV 592 mV 596 mV 1000 mV 3300 mV 4998 mV 3280 mV 1005 mV 1801 mV 2500 mV 14 mV 12650 mV 267 mV 69 mV 12550 mV 0 mV 69 mV 12575 mV 0 mV 11 mV 12525 mV 0 mV 40 Celsius 47 Celsius 45 Celsius 31 Celsius 25 Celsius 35 Celsius 31 Celsius 29 Celsius 31 Celsius 35 Celsius 43 Celsius 45 Celsius 0 MHz 0 MHz Freq: 5338-89 3882_1_0: VOUT 3882_1_1: VOUT 3882_2_0: VOUT 3882_2_1: VOUT 3882_3_0: VOUT 3882_4_0: VOUT 3882_5_0: VOUT 3882_6_0: VOUT 3882_7_0: VOUT 3882_7_1: VOUT 3882_8_0: VOUT 3882_9_0: VOUT V2978: VSENSE0 V2978: VSENSE1 V2978: VSENSE2 V2978: VSENSE3 V2978: VSENSE4 V2978: VSENSE5 V2978: VSENSE6 V2978: VSENSE7 V2978: VIN PSOC_2_0: VOUT PSOC_2_1: VOUT PSOC_2_2: VOUT PSOC_2_3: VOUT PSOC_2_4: VOUT PSOC_2_5: VOUT PSOC_2_6: VOUT PSOC_2_7: VOUT PSOC_2_8: VOUT PSOC_2_9: VOUT PSOC_2_10: VOU PSOC_2_11: VOU PSOC_2_12: VOU PSOC_2_13: VOU PSOC_2_14: VOU PSOC_2_15: VOU LTC4261: Power PEM Iout PEM Vout PEM Vin Temp: INLET Temp: OUTLET PEM Iout PEM Vout PEM Vin Temp: INLET Temp: OUTLET PEM Iout PEM Vout PEM Vin Temp: INLET Temp: OUTLET PSOC-MB2_0: VO PSOC-MB2_1: VO PSOC-MB2_2: VO PSOC-MB2_3: VO PSOC-MB2_4: VO PSOC-MB2_5: VO PSOC-MB2_6: VO PSOC-MB2_7: VO PSOC-MB2_8: VO PSOC-MB2_9: VO PSOC-MB2_10: V PSOC-MB2_11: V PSOC-MB2_12: V PSOC-MB2_13: V PSOC-MB2_14: V PSOC-MB2_15: V PSOC-MB2_16: V PSOC-MB2_17: V PSOC-MB2_18: V 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 P0 P0 P0 P0 P0 P1 P1 P1 P1 P1 P2 P2 P2 P2 P2 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal 0 MHz 3299 mV 1800 mV 2500 mV 1199 mV 1419 mV 1350 mV 1000 mV 1021 mV 1199 mV 1000 mV 1000 mV 999 mV 0 mV 0 mV 0 mV 6000 mV 2400 mV 0 mV 6598 mV 4998 mV 25218 mV 12582 mV 4985 mV 3256 mV 1982 mV 1990 mV 1782 mV 1793 mV 1786 mV 1483 mV 1193 mV 995 mV 987 mV 994 mV 707 mV 592 mV 593 mV 340 Watts 5 A 55 V DC 202 V AC 26 Celsius 48 Celsius 6 A 55 V DC 204 V AC 30 Celsius 53 Celsius 3 A 55 V DC 204 V AC 25 Celsius 51 Celsius 12758 mV 4998 mV 7082 mV 3287 mV 989 mV 1047 mV 1500 mV 1800 mV 914 mV 885 mV 994 mV 989 mV 1479 mV 989 mV 984 mV 890 mV 2485 mV 1346 mV 1458 mV 5 PSOC-MB2_19: V PSOC-MB2_20: V PSOC-MB2_21: V PSOC-MB2_22: V PSOC-MB2_23: V PSOC-MB2_24: V PSOC-MB2_25: V PSOC-MB3_0: VO PSOC-MB3_1: VO PSOC-MB3_2: VO PSOC-MB3_3: VO PSOC-MB3_4: VO PSOC-MB3_5: VO PSOC-MB3_6: VO PSOC-MB3_7: VO PSOC-MB3_8: VO PSOC-MB3_9: VO PSOC-MB3_10: V PSOC-MB3_11: V PSOC-MB3_12: V PSOC-MB3_13: V PSOC-MB3_14: V PSOC-MB3_15: V PSOC-MB3_16: V PSOC-MB3_17: V PSOC-MB3_18: V PSOC-MB3_19: V PSOC-MB3_20: V PSOC-MB3_21: V PSOC-MB3_22: V PSOC-MB3_23: V PSOC-MB3_24: V PSOC-MB3_25: V PSOC-MB3_26: V PSOC-MB3_27: V 3882_MB1_0: VO 3882_MB1_1: VO 3882_MB2_0: VO 3882_MB3_0: VO 3882_MB3_1: VO 3882_MB4_0: VO 3882_MB5_0: VO 3882_MB6_0: VO 3882_MB6_1: VO 3882_MB7_0: VO 3882_MB8_0: VO 3882_MB8_1: VO 3882_MB9_0: VO 3882_MB9_1: VO 15301_1: VOUT 15301_2: VOUT 15301_3: VOUT AS_VRM: Sens AS_VRM: Vin AS_VRM: ADin Y0_VRM: Sens Y0_VRM: Vin Y0_VRM: ADin CPU_VCC: Sens CPU_VCC: Vin CPU_VCC: ADin 5P0_BIAS: Sens 5P0_BIAS: Vin 5P0_BIAS: ADin 7P0_BIAS: Sens 7P0_BIAS: Vin 7P0_BIAS: ADin 1P0_AA: Sens 1P0_AA: Vin 1P0_AA: ADin 1P0_RT: Sens 1P0_RT: Vin 1P0_RT: ADin 6 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal 1208 mV 1791 mV 3293 mV 3250 mV 3284 mV 4970 mV 4451 mV 4983 mV 4979 mV 1500 mV 1192 mV 705 mV 752 mV 579 mV 1500 mV 1501 mV 1250 mV 1247 mV 1260 mV 1038 mV 1343 mV 670 mV 1800 mV 908 mV 823 mV 992 mV 984 mV 1046 mV 1192 mV 1169 mV 1187 mV 1796 mV 1792 mV 1787 mV 1034 mV 1001 mV 1022 mV 1197 mV 1045 mV 996 mV 898 mV 1348 mV 1350 mV 3297 mV 998 mV 1501 mV 1551 mV 999 mV 3296 mV 2500 mV 1200 mV 1200 mV 40 mV 12725 mV 0 mV 23 mV 12675 mV 380 mV 6 mV 12725 mV 0 mV 19 mV 12700 mV 0 mV 45 mV 12725 mV 0 mV 37 mV 12700 mV 0 mV 16 mV 12725 mV 0 mV 1P2: Sens 1P2: Vin 1P2: ADin 0P9_T0: Sens 0P9_T0: Vin 0P9_T0: ADin 1P05_CPU: Sens 1P05_CPU: Vin 1P05_CPU: ADin 1P0_CC: Sens 1P0_CC: Vin 1P0_CC: ADin 1P35_DDR: Sens 1P35_DDR: Vin 1P35_DDR: ADin 1P35_RLD: Sens 1P35_RLD: Vin 1P35_RLD: ADin 3P3_CCC: Sens 3P3_CCC: Vin 3P3_CCC: ADin 1P0_R: Sens 1P0_R: Vin 1P0_R: ADin 1P5_A0: Sens 1P5_A0: Vin 1P5_A0: ADin 1P5: Sens 1P5: Vin 1P5: ADin 2P5: Sens 2P5: Vin 2P5: ADin 1P8_A: Sens 1P8_A: Vin 1P8_A: ADin 1P0_BV: Sens 1P0_BV: Vin 1P0_BV: ADin 3P3: Sens 3P3: Vin 3P3: ADin 1P2_B: Sens 1P2_B: Vin 1P2_B: ADin ADM1075: Power Temp: Y0_DIE Temp: BB_DIE Temp: VP_DIE Temp: RT-E_DIE Temp: INLET_1 Temp: INLET_2 Temp: OUTLET_1 Temp: 3882_1 Temp: 3882_1A Temp: 3882_1B Temp: 3882_2 Temp: 3882_2A Temp: 3882_2B Temp: 3882_3 Temp: 3882_3A Temp: 3882_3B Temp: 3882_4 Temp: 3882_4A Temp: 3882_4B Temp: 3882_5 Temp: 3882_5A Temp: 3882_5B Temp: 3882_6 Temp: 3882_6A Temp: 3882_6B Temp: 3882_7 Temp: 3882_7A R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal 37 mV 12675 mV 0 mV 7 mV 12750 mV 0 mV 11 mV 12700 mV 0 mV 16 mV 12700 mV 0 mV 6 mV 12725 mV 0 mV 0 mV 12675 mV 2047 mV 16 mV 12700 mV 1375 mV 29 mV 12700 mV 0 mV 41 mV 12700 mV 0 mV 34 mV 12675 mV 0 mV 5 mV 12700 mV 0 mV 10 mV 12675 mV 947 mV 24 mV 12700 mV 0 mV 16 mV 12725 mV 0 mV 41 mV 12725 mV 0 mV 329 Watts 33 Celsius 29 Celsius 26 Celsius 31 Celsius 23 Celsius 22 Celsius 25 Celsius 46 Celsius 43 Celsius 43 Celsius 41 Celsius 40 Celsius 41 Celsius 37 Celsius 34 Celsius 33 Celsius 46 Celsius 38 Celsius 35 Celsius 32 Celsius 23 Celsius 23 Celsius 37 Celsius 30 Celsius 32 Celsius 38 Celsius 35 Celsius 7 Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Temp: Freq: Freq: 3882_7B 3882_8 3882_8A 3882_8B 3882_9 3882_9A 3882_9B 8314_1 8314_2 3536_1A 3536_1B 15301_1A 15301_1B 15301_2A 15301_2B 15301_3A 15301_3B AS_DIE XPT1_DTL XPT1_DTR XPT1_DBL XPT1_DBR XPT2_DTL XPT2_DTR XPT2_DBL XPT2_DBR XPT3_DTL XPT3_DTR XPT3_DBL XPT3_DBR MAX3674 SQ420D R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 R0 Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal Normal 35 Celsius 47 Celsius 45 Celsius 41 Celsius 37 Celsius 33 Celsius 32 Celsius 40 Celsius 36 Celsius 26 Celsius 26 Celsius 31 Celsius 32 Celsius 28 Celsius 34 Celsius 38 Celsius 45 Celsius 70 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 42 Celsius 500 MHz 24 MHz • show facility-alarm status —Verify the chassis status. Router# show facility-alarm status System Totals Critical: 4 Source -----slot 3/0 OIR Alarm [0] Power Supply Bay 3 Module Missing [0] Power Supply Bay 4 Module Missing [0] Power Supply Bay 5 Module Missing [0] Cable3/0/15-US0 Down [0] Cable3/0/15-US1 Down [0] Cable3/0/15-US2 Down [0] Cable3/0/15-US3 Down [0] Cable3/0/15-US4 Down [0] 8 Major: 1 Minor: 8 Time -----Apr 13 2015 16:25:58 Severity -------CRITICAL Description [Index] ------------------Active Card Removed Apr 13 2015 13:41:56 CRITICAL Power Supply/FAN Apr 13 2015 13:41:56 CRITICAL Power Supply/FAN Apr 13 2015 13:41:56 CRITICAL Power Supply/FAN Apr 13 2015 17:32:53 MINOR Physical Port Link Apr 13 2015 17:32:53 MINOR Physical Port Link Apr 13 2015 17:32:53 MINOR Physical Port Link Apr 13 2015 17:32:53 MINOR Physical Port Link Apr 13 2015 17:32:53 MINOR Physical Port Link © 2015 Cisco Systems, Inc. All rights reserved. Americas Headquarters Cisco Systems, Inc. San Jose, CA 95134-1706 USA Asia Pacific Headquarters Cisco Systems (USA) Pte. Ltd. Singapore Europe Headquarters Cisco Systems International BV Amsterdam, The Netherlands Cisco has more than 200 offices worldwide. Addresses, phone numbers, and fax numbers are listed on the Cisco Website at www.cisco.com/go/offices.
© Copyright 2026 Paperzz