AirWare: air quality assessment and management information system AirWare: air quality management information system for urban and industrial applications AirWare is an integrated, model-based information and decision support system for air quality assessment and management. The system supports the implementation of European and national environmental legislation such as the European Air Quality Framework Directive 96/62/EC and Daughter Directives, 88/609/EEC on major point sources, 89/429/EEC and 89/369/EEC on incinerators or 90/313/EEC on public access to environmental information. Designed for urban agglomerations and industrial areas, the modular software system integrates monitoring data acquisition and analysis, emission data bases and an embedded GIS, simulation and optimisation models with coverage from local to regional scales, an expert system for environmental impact assessment, and a range of decision support tools. A distributed client-server implementation and a fully web-based user interface exploit the latest multi-media and network computing technologies. Technical Description AirWare: The Product On-line Manuals Reports, Imagery Regulatory Framework Reference Applications Explore the on-line interactive model demos AirWare receives important input from EUREKA projects E!3266 WEBAIR & E!1388 AIDAIR that develop real-time models and transportation system linkages. The Telematics applications project ECOSIM, has developped a flexible client-server architecture based on TCP/IP and http, linkage to state-of-theart dynamic 3D photochemical models, as well as to other environmental models in the urban domain SUTRA has analysed the relationship between urban land use, transportation, and the environment. ISIREMM, an INCO Copernicus project, was dealing with the integration of monitoring data and a case study for Tomsk, Siberia. The ESPRIT HPCN project SIMTRAP, has addressed urban traffic problems and the integration of dynamic traffic simulation and parallel urban scale photochemical modeling file:///D|/PSI/CMS_Materi/MIS%20Example.htm (1 of 2) [7/30/2005 6:01:05 PM] The ESPRIT HPCN project HITERM, was addressing issues of technological risk assessment, planning, training, and emergency management, including local emergency simulation models AirWare: air quality assessment and management information system © Copyright 1995-2005 by: ESS Environmental Software and Services GmbH AUSTRIA | print file:///D|/PSI/CMS_Materi/MIS%20Example.htm (2 of 2) [7/30/2005 6:01:05 PM] page
© Copyright 2026 Paperzz