FLOW www.platon-direct.eu Product Data Sheet Metal Tube VA Gas or Liquid METAL TUBE VA FLOWMETER TYPE GMT FEATURES GMT metal tube flowmeters are variable area meters of totally welded stainless steel construction. Liquid or Gas flowing up the tapered flowtube lifts the float to an equilibrium position, dependent on flow rate, and a magnetically coupled pointer indicates this flow on an external scale. The large meter indication is easily visible at a distance, with the pointer moving over a 150o scale. Each scale is produced specifically for the fluid involved and process conditions expected: several flow ranges are available for meters of each standard line size. All gas flow meters are supplied with an integral piston damper to smooth out flow pulsations. Installation is simple, in a vertical section of flow line: meters can be supplied with DIN, ANSI or other standard flanges, or BSP or NPT screwed connections. The robust construction with no glands or seals to leak means the meters are suitable for high pressure applications, or extremes of temperature. The standard GMT is totally self contained and needs no external power. Alternative materials are available to special order for example Hastelloy or Monel wetted parts, PTFE lined versions. For lower cost, Brass or Stainless steel bodied meters `” - 2” in size are available with screwed connections. The indicator can be provided with one or two flow alarm sensors, adjustable over the meter operating range. Full electronic transmission and totalisation is also available, using the “VAMPIRE” electronic module. Metal tube meters are ideal for arduous industrial service as an alternative to large glass tube flowmeters. They have particular advantages, where fluids are opaque or staining, or to provide higher safety and security for dangerous or toxic fluids. DS1220/1221 15, 25, 50, 75 and 100mm 1/2" 1" 2" 3" & 4" line sizes No power required Clearly visible meter Scaled for process fluids Easy installation - flanged or screwed No glands or seals Robust, simple construction Pulsation damper on gas meter PRINCIPLE OF OPERATION The metering element consists of a precision machined tapered tube and a float. The height to which the float rises in taper is determined by the gap at which upward flow force and float weight are balanced. A permanent magnet encapsulated within the stainless steel float drives the external magnetically coupled pointer. Float movement is related to flow rate, and the indicator scale is marked in the correct units of flow for the process conditions. The standard unit requires no electrical power. Because the measuring element is a sharp edged disc, the meter is relatively insensitive to viscosity changes in the fluid, and to pipe bends in the external pipework. The only moving part in the flow is the float, which is retained in place by float guides at either end of the meter. LICO Electronics GmbH, A-2320 -Kledering email: [email protected] [email protected] Tel +43 1 706 43 00 DS1220 Issue 5: 06. Page 1 of 4 SPECIFICATION Flanged flow tube 316 Stainless steel, all welded construction Indicator housing Flanges DIN PN16 (BS4504) or ANSI 150 standard. Other flanges to order 15, 25, 50, 80, 100mm To flange rating, 100 bar max Protection Brass or 316 Stainless Steel `”, 1” or 2” BSPP or NPT standard 75 bar max GMTB (Brass) 100 bar max GMTS (Stainless) 316 Stainless steel PVC float on low pressure drop option units All gas flowmeters have a dashpot damper built-in Turndown Accuracy Typically 100mm, 150 degrees Produced to order to suit process fluid and conditions. Air and water flow ranges quoted opposite Typically 10:1 ±2% FSD Hysteresis ±0.5% FSD Fluid Temperature 200oC max (higher to special order) Less than 0.5 secs Vertically upwards 1.6µm Line Sizes Pressure Screwed flow tube Connections Pressure Float Pulsation damper Scale length Scales Response time Flow direction Surface Finish Polyester coated aluminium alloy,with UV stable polycarbonate face IP65 ORDER CODE Model Number GMT - - 3 1 4 G GMT family - (Example is 2”GMT,Flanged PN16, ranged 20 - 180m3/h Air) Fluid G = Gas, max 2" L = Liquid, max 4" Model Type No digit Flanged stainless B Brass body screwed S Stainless body screwed Digit to identify specified Flow Range (See Table on next page) Electronic outputs No digit standard indicator A Single flow alarm AA Dual flow alarm XA AC powered transmitter XD CENELEC Approved Looped powered transmitter End Connections 1 Flanged DIN PN16 2 Flanged ANSI 150lb 3 Flanged DIN PN40 4 Flanged ANSI 300lb 5 Screwed BSPP female 6 Screwed NPT female Flow pipe size 1 15mm or `” 2 25mm or 1” 3 50mm or 2” 4 80mm or 3” 5 100mm or 4” Note: Not all options available together. TO ORDER Specify process conditions at measurement point (fluid type, density/SG, viscosity, temperature, and pressure) plus operational flow range and units LICO Electronics GmbH, A-2320 -Kledering email: [email protected] [email protected] Tel +43 1 706 43 00 DS1220 Issue 5: 16.02.06 Page 2 of 4 FLOW RANGES STANDARD UNITS LOW DP GAS UNITS Size/Model Flow Digit Water(20oC) Air at ATP (m3/hr) Max DP (mbar) Flow Digit Air (ATP) m3/hr 15mm (GMT1) 1 2 3 4 20 - 160 l/h 20 - 250 l/h 40 - 400 l/h 60 - 600 l/h 0.5 - 5.0 0.5 - 7.5 1.2 - 12 2.0 - 18 15 30 20 35 A B C D 25mm (GMT2) 1 2 3 4 5 6 0.1 - 1.0 m3/h 0.2 - 1.6 m3/h 0.2 - 2.5 m3/h 0.4 - 4.0 m3/h 0.6 - 6.0 m3/h 1.0 - 10.0 m3/h 3.0 - 30 4.0 - 50 10 - 75 12 - 120 20 - 200 30 - 360 15 30 35 80 160 400 A B C D 50mm (GMT3) 1 2 3 4 0.6 - 6 m3/h 1.0 - 10 m3/h 2.0 - 16 m3/h 2.0 - 25 m3/h 20 - 180 30 - 300 60 - 600 100 - 1000 30 40 80 190 80mm (GMT4) 1 2 3 2.0 - 25 m3/h 3.0 - 40 m3/h 6.0 - 60 m3/h N/A N/A N/A 140 220 525 1 10 - 100 m3/h N/A 440 100mm (GMT5) Max DP (mbar) 0.3 - 3 0.4 - 4 0.5 - 7 1.0 - 9 Natural Gas (ATP) (m3/hr) 0.4 - 3.5 0.5 - 5 1.0 - 9 1.0 - 12 1.5 - 15 3 - 23 4 - 36 5 - 50 2 - 20 4 - 30 5 - 45 6 - 60 8 9 8 9 7 10 7 10 NOTES 1. Units will be scaled and calibrated for customers specific process conditions, which may differ from those tabulated (See overleaf ). 2. Typical maximum liquid viscosity is 50cP, lower for the highest flow ranges and small sizes. 3. Screwed 1” units are not available for Flow Digit 6. OPTIONS 1. Oxygen Service Standard units cleaned to required specification. Special units available with Brass internal construction 2. Alarm Output Sensor NAMUR type SJ2-N to DIN 19234 Approval EEx ia IIC T6 Single or dual alarms can be fitted to a GMT flowmeter: the sensor requires a suitable control room interface. Please ask for suppliers separate data sheet. 3. Electrical Output All GMT flow tube sensors can be fitted with “VAMPIRE” mirco based electronic transmitter and flow indicator units. Please see Data Sheet DS1225. 4. Alternative body Materials/Designs The PTFE lined meter option is used for corrosive chemicals. Float, guides and flange raised face are PFTE or ceramic. The hygienic option with crevice free construction is polished to 0.4 - 0.8µm finish and fitted with Triclover connections. In addition Triclover, RJT, DIN 11851, SMS connections can be fitted to Std flanged body. Refer to DS1221 for Screwed GMT datasheet LICO Electronics GmbH, A-2320 -Kledering email: [email protected] [email protected] Tel +43 1 706 43 00 DS1220 Issue 5: 16.02.06 Page 3 of 4 ALTERNATIVE FLUIDS Approximate flow ranges for alternative process fluids and gas pressures can be calculated using the following formulae. For a full calculation please contact our Sales Team. 1. Gases at pressure or temperature For Air or gas flows where the pressure in the line on the discharge side of the flowmeter is not atmospheric (1.013 bar), multiply the flow range at ATP quoted in the table by a factor calculated as the square root of the pressure (in bar abs) divided by 1.013. Air flow in process = P (abs) 1.013 x Air flow in table For temperature changes Air flow at T = 2. 293 T (K) x Air flow in table Alternative gases For gases other than Air, find the Relative Density (RD) of the gas compared to Air, and divide the flow range quoted for Air in the table by the square root of the Relative Density. 1 RD Gas flow range = Air flow in table x Examples of RD figures for some gases are as follows: Acetylene Argon Butane 3. 0.898 1.380 2.007 Carbon dioxide Hydrogen Natural Glass 1.520 0.070 0.608 Nitrogen Oxygen Propane 0.968 1.105 1.522 Alternative Liquids For non vicious liquids other than water, the main correction arises from the density/SG. For the process liquid flow range multiply the Water flow range from the table by a factor D from below. SG D 0.6 1.328 0.7 1.221 0.8 1.134 0.9 1.062 1.0 1.000 1.1 0.947 1.2 0.900 1.3 0.858 1.4 0.821 For a liquid of 1.2 SG, the GMT411L flowmeter would have a full scale flow of 25 x 0.9 ie. 22 m3/hr: the scale would be drawn 2 - 23 typically. Actual scale used would be rounded up, for example 2 - 23 in this case. B E D 27 DIMENSIONS 126 C Pipe Bore A B C D E F C F (AF) A 106 15 51 48 250 51 26 27 25 45 51 250 49 34 41 50 42 66 250 49 27 60 80 42 87 300 75 N/A N/A 100 39 100 400 113 N/A N/A INSTALLATION 1. 2. 3. 4. 5. All VA meters are designed for vertical installations, with flow upwards. It is necessary to have 5 straight pipe diameters upstream and 2 straight pipe diameters downstream. Bends in two planes should be avoided. The upstream and downstream pipe bores should suit the normal size of the instrument, if possible. Ensure that no ferromagnetic material is situated within 100mm of the indicator. Before installing the meter, the pipeline should be flushed to remove any foreign matter, or swarf, likely to collect on the float unit and magnet. For ultimate protection a filter should be fitted upstream of the meter to remove large particles. Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.. LICO Electronics GmbH Klederinger Str. 31 A-2320 Kledering, Austria [email protected] www.lico.at Tel. +43 1 706 43 00 www.mess-regeltechnik.at DS1220 www.platon-direct.eu Issue 5: 16.02.06 Page 4 of 4 FLOW www.platon-direct.eu Product Data Sheet DS1221 Platon Screwed Metal Tube VA Flowmeter PLATON GMTB & S SERIES FEATURES Part of the Platon GMT Variable Area flowmeter family, models GMTB and GMTS are brass or Stainless Steel tube flowmeters with female screwed connections. With 1/2”, 1” and 2” BSP/NPT threaded fittings standard, the meters are ideal for arduous industrial service as an alternative to large glass tube flowmeters. They have particular advantages for gas or liquid flow measurement at high pressures and temperatures, where the fluids are opaque or dark coloured or to provide higher operational security for dangerous or toxic materials. • Economic construction • BSP/NPT screwed end fittings • Brass or Stainless Steel • Wide flow ranges • Sizes 15, 25, 50mm. 1/2”, 1”, 2” bore • Integral damping on gas flow lines • Local indication • Calibration for wide range of gases The VA meter principle used in the Platon GMT flowmeter measures the position of a float in a precision-machined tapered tube. The float rises with the flow up the taper until the upthrust from the flow balances with the weight of the float. A magnet, electron beam welded into the float casing, drives the external meter indication over a 100mm scale typically displaying a 10:1 flow range. and liquids • Optional electronic outputs Options available on the GMTB/GMTS include (GMTA) flow alarm outputs for high or low adjustable set points and electronic 4-20mA flow transmitter (GMTX) outputs. All of these are available with CENELEC intrinsically safe approval. For low-pressure Natural gas flow measurement, models are available with minimal line pressure loss. Special versions are available for Oxygen service. All units are available calibrated for the specific line conditions or fluid involved. LICO Electronics GmbH, A-2320 -Kledering email: [email protected] [email protected] Tel +43 1 706 43 00 DS1221 Page 1 of 2 SPECIFICATION Body Materials GMTB: Brass GMTS: 316 Stainless Steel 316 Stainless Steel Aluminium alloy LM25M polyester coated, weather-proofed to IP65 BSP or NPT female thread sizes 1/2”, 1”, 2” 100mm, 150 degrees. Air or water. Standard scales. Custom scales available to order Typically 10:1 ±2% FSD Less than 0.5% GMTB: 75 bar GMTS: 100 bar 200oC o -50oC (Based on Ambient of 20 C) To smooth out flow fluctuations and noise on gas flows, a dashpot damper is built in. This is suitable for clean gases where particulate matter is less than 50 microns. Std variants available for low pressure drop applications, using PVC float assemblies See catalogue for full details. Specify line pressure and flow range when enquirying. CRN (Contact sales for details) Float & Float Guides Indicator Housing Connections Scale Length Turndown Accuracy Hysteresis Pressure Temperature OPTIONS AVAILABLE Max Min Dashpot Damper Natural Gas Approvals • Calibration for different liquids or gases or for nonstandard operating process conditions • Flow alarm outputs (GMTA) or analogue 4-20mA (GMTX, DS1225) outputs, with CENELEC approval if required • Higher pressure or temperature models • Alternative materials • Flanged and hygienic connections • Hygienically polished • PTFE lined flanged units • Special models for Oxygen service, including all brass designs. Stainless Steel flanged versions of the GMT flowmeter are described in Roxspur data DS1220 J H I E G INSTALLATION NOTES A 1. The instrument should be installed vertically in the pipework with the direction of flow vertically upwards. 2. Ensure that any ferromagnetic material is clear of the body and indicator case by 100mm minimum. 3. The upstream and downstream pipe bores should be the same nominal size as the instrument. Straight pipe lengths of 5 diameters upstream and 2 diameters downstream should be provided if possible. 4. Before the meter is installed, the pipeline should be checked, cleaned and flushed to eliminate any foreign matter. An appropriate filter should be fitted upstream if any particle present is likely to be greater than 50 microns. 5. B Model 15mm GMT*151† GMT*152† GMT*153† GMT*154† GMT*251† GMT*252† GMT*253† GMT*254† GMT*255† GMT*351† GMT*352† GMT*353† GMT*354† 25mm 50mm * † Max Water Flow L/h 20oC 160 250 400 600 1000 1600 2500 4000 6000 6000 10000 16000 25000 D C A B C D E F G H I J 15 51 48 51 1/2” 27 26 1” 34 41 25 126 45 106 51 27 250 49 2” 27 60 50 42 66 Solenoid valves should not be used where they act directly on the instrument. Size F Max Air Flow m3/h at 20oC, 1.013 bar abs 5 7.5 12 18 30 50 75 120 200 180 300 600 1000 Pressure Drop At Max Flow (mbar) 15 30 20 35 15 30 35 80 160 30 40 80 190 In the model code, GMTB represents Brass and GMTS Stainless Steel flow tube construction. The final suffix is L for Liquid and G for Gas operation. Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice. 03HWAR0410 LICO Electronics GmbH Klederinger Str. 31 A-2320 Kledering, Austria [email protected] www.lico.at Tel. +43 1 706 43 00 www.mess-regeltechnik.at DS1221 www.platon-direct.eu Page 2 of 2 FLOW Product Data Sheet DS1225 www.platon-direct.eu Vampire - Electronic Indicator TYPE GMTX OPERATING PRINCIPLE The GMTX electronic indicator with microprocessor enhanced performance and LCD panel display of flow rate and total, designed for use with a metal tube variable area flowmeter for liquid, gas or steam measurement, The VAMPIRE is a metal tube variable area flowmeter: as the flow up through the precision machined tapered tube increases, the float rises, reaching an equilibrium position. Electron beam welded within the float casing is a magnet. Two “Hall effect” magnetic field sensors measure both the vertical and horizontal components on this field. The angle of the magnetic field defines the position of the float in the tapered tube. This solid state measurement eliminates the problems of mechanical hysteresis associated with conventional magnetic pointers. Field angle is also independent of the absolute value of magnet strength, and sensor sensitivity. Suitable for use with body options, the VAMPIRE (Variable Area Micro Proc-essor Indicator Readout Electronics) has a totally solid state measurement system, eliminating mechanical hysteresis errors. Microprocessor interpolation between flow data points, stored in factory calibrated look-up tables, gives an improvement to ±1% accuracy for this technique. The loop powered 4-20mA transmitter is certified intrinsically safe to CENELEC standards, for use in a potentially haz-ardous area. Both loop powered and AC mains powered units have separate high and low flow alarm outputs. ask for maintainance & operations manual OMM1033 FEATURES • • • • • • • • 4-20mA Transmitter Intrinsically safe approval Liquid or Gas Flow Calibration Built-in Flow Totaliser Operator adjustable High and Low Alarms 1% Accuracy VA meter reliability Program setting password protection email: [email protected] DS1225 Issue 3: 23.02.06 www.platon-direct.eu Page 1 of 3 The measurements are compared with a look-up table of field and flow data, stored in the VAMPIRE microprocessor memory on factory flow rig calibration. Flow rate is deduced accurately by interpolation between data points. The micro-processor converts the flow rate to correct Engineering units for the digital display on the LCD, adjusts the display meter pointer and 4-20mA output, sets the Alarm status and increments the totaliser as necessary. Keypads on the VAMPIRE front panel are used to set flow alarm levels, zero the totaliser and select the digital display as rate or total. Via a password entry procedure, the site engineer can reset the display units or even rescale the flowmeter to allow for changes to process conditions. This programme also has selections to define what functions are accessible to the operator (without password), plus zero, span and time constant adjustments. GMTX2 (25mm/1” Ø 250 Long) GMTX3 (50mm/2” Ø 250 Long) GMTX4 (80mm/3” Ø 300 Long) GMTX5 (100mm/4” Ø 400 Long) Model Flow Digit Digit GMTX 1 (15mm/1/2” Ø 250 Long) 1 2 3 4 Water (L/hr) Air (m3/hr) Max ∆P (mBar) 160 250 400 600 5 7.5 12 18 15 30 20 35 30 50 75 120 200 360 180 300 600 1000 - 15 30 35 80 160 400 30 40 80 190 140 220 525 440 SPECIFICATION Temperature Housing Glands Earth Stud GMTXA GMTXD Display Resolution Alarm output Totaliser Approvals Zener Barriers DISPLAY 1000 1600 2500 4000 6000 10,000 6 10 16 25 25 25 60 100 NB Ranges are quoted for Water at 20oC, Air at ATP (1.013 Bar and 20oC). Flow ranges for other fluids or process conditions on application. Units will be calibrated for customers specific conditions. Normally, scales offer 10:1 operating turndown. Pressure drops quoted are at maximum flow rates. Calibration Analogue output FLOW RANGES 1 2 3 4 5 6 1 2 3 4 1 2 3 1 GMTX: 50oC GMTA: 70oC Fluid 300oC Polyester coated aluminium. Weatherproof to IP65 4 off suitable for 2-5mm cable. External M6 stud fitted. 85-265V, 50-60Hz, 0-2A max - current consumption 24Vdc loop powered (12V min, 30V max LCD 0-100% analogue scale 90mm long. Digital Display, 4/5 digits 10mm high. Selectable for Flow Rate or Total. ±1% FSD GMTXA 20mA into 600Ω max. GMTXD 4-20mA, 2 wire transmitter. 0.5%on current output, 80mA GMTXA: 2 x 8A SPCO relays @ 230V ac max 100mA, max switched 30V, Internal Impedance 100Ω. GMTXD: 2 x open collector transistors. Display 1-19,999. Pulse output selectable instead of flow alarm output. 50msec pulse length. Max pulse rate 2/sec (GMTXD). GMTXD is intrinsically safe approvded to CENELEC EExia IIBT4. CRN (Contact Sales for details). 28V, 300W for 20mA line. 10V, 50W for alarm signals. Ambient Liquid Crystal Display Panel KEYPADS High Alarm Value Flow Rate Meter (% Scale) Low Alarm Value Reset Totaliser (if programme allows) Alarm Messages Flash (when tripped) Select Rate or Total Display Enter Programme via Password Programme Prompts Engineering Units Selected for Digital Display Digital Display - Flow Rate or Flow Total email: [email protected] DS1225 Issue 3: 23.02.06 www.platon-direct.eu Page 2 of 3 METAL TUBE FLOWMETER FAMILY INSTALLATION VAMPIRE flow measurement electronics can be supplied with any of the Platon metal tube variable area flowmeters in the GMT family (see leaflet DS1221 Screwed and DS1220 Flanged). 1. Ensure that no ferromagnetic material is situated within 100mm of the indicator. 2. Model GMTXA has output relays de-energised for alarm conditions. 3. Model GMTXD transistor outputs are “off” for alarm conditions. The negative line is common to the transistor outputs and the loop supply. 4. Intrinsically safe installations of Model GMTXD should be in accordance with BS5345 Part 4. The 4-20mA loop should be protected by an approved standard 28 Volt 300W shunt diode safety barrier. If required, the alarm outputs should be connected via approved 10 Volt 50W safety barriers. 5. It is recommended that the VAMPIRE LCD display is protected from both extremes of freezing and direct sunlight. Microprocessor Computation and Calibration look-up tables FEATURES IP65 Keypad Separate Terminal Box Liquid Crystal Display Panel Tapered Flow Tube Solid State Magnetic Field Sensors ‘Float’ Magnet Inside Electron Beam Welded Casing Pulsation Damper on Gas Flow Meters Stainless Steel, Brass or Ptfe Lined Tube Flanged or Screwed Connections Every effort has been made during the preparation of this document to ensure the accuracy of statements and specifications. However, we do not accept liability for damage, injury, loss or expense caused by errors or omissions made. We reserve the right to withdraw or amend products or documentation without notice.. LICO Electronics GmbH Klederinger Str. 31 A-2320 Kledering, Austria [email protected] www.lico.at Tel. +43 1 706 43 00 www.mess-regeltechnik.at DS1225 www.platon-direct.eu Issue 3: 23.02.06 Page 3 of 3
© Copyright 2026 Paperzz