Quantum™ QC, 8 Peak Beads B E A D S A B OV E T H E R E ST Product Data Sheet 725 DESCRIPTION Quantum™ QC is a 8 peak multi-intensity, multi-fluorescent standard that is intended for use as an in-depth tool for daily cytometer QC, and is appropriate for use with all lasers and detectors. It may be used to determine detection thresholds, understand resolution, and assess and track linearity of detectors. It can aid in providing confidence that the system is suitable for use, or alert operators to potential problems before samples are run. 100 Count ~5µm Bottle 1 (mixed, 7 fluorescent intensity populations),1 x 107 beads / mL Bottle B (Blank), 2 x 106 beads / mL De-ionized water + 0.01% Tween®20 + 2mM NaN3 0 Mean Diameter: Particle Concentration: Storage Buffer: 50 CHARACTERISTICS 150 Quantum™ QC may also be used for instrument set-up to achieve standardized PMT settings and define the window of analysis for relevant detectors. PROCEDURE 102 103 104 105 FITC Daily QC: Quantum™ QC may be used on a routine basis to assess the resolution, linearity and threshold for most detectors on the cytometer. Our QuickCal Linearity tool provides templates for 7 detectors: VIO-450, VIO-525, FITC, PE, PE-Cy™5, APC, and APC-Cy™7. 1. Go to bangslabs.com/quickcal to download the QuickCal®- Linearity template. 2. Select the file for download. 3. Select the appropriate version based on the resolution of your instrument: • Semi-Log (e.g. 1024 channels) • Log / Log (e.g. FACSDiva) 4. The template will download to your computer. 5. Adjust PMT voltages for each detector to standard daily settings. 6. Place one drop of the blank (bottle B) and one drop of the mixed fluorescent population (bottle 1) in a tube. Dilute with ~800µL DI water. (The Blank may also be run separately from the fluorescent populations to improve resolution.) 7. Run on LOW to achieve a count rate of 100-150 events/sec; low run rates aid in achieving lowest fluorescence CV’s. 8. For each detector, gate on individual peaks, and record channel values (Median or Geo. Mean). Enter these values in the appropriate tables of the QuickCal® Linearity template. A Detection Threshold and Regression Figure 1 Coefficient (r2) will be calculated for each detector. Bangs Laboratories, Inc. QuickCal® Linearity v 2.3-L Quantum™ QC Instrument ID: Date Acquired: Date Entered: 725 / 11446 Vio-450 Enter Filter: Enter PMT voltage: Bead Intensity % Blank 0 Bead #1 20.10 Bead #2 25.58 Bead #3 38.25 Bead #4 52.37 Bead #5 75.16 Bead #6 90.32 Bead #7 100.00 Regression Coefficient (r2) Detection Threshold (%) Channel Data incomplete Data incomplete FITC Enter Filter: Enter PMT voltage: Bead Intensity % Blank 0 Bead #1 12.44 Bead #2 22.78 Bead #3 32.46 Bead #4 49.50 Bead #5 70.08 Bead #6 84.80 Bead #7 100.00 2 Regression Coefficient (r ) Detection Threshold (%) Rqd7 beads Mod Factor Bead x^2 y y^2 x*y Blank 0 0 0 0 0 count0 m= n b= n corr= Channel Enter Enter Enter Enter Enter Enter Enter Enter Data incomplete Data incomplete Rqd 7 beads Mod Factor x^2y y^2x*y 0 0 0 0 0 count0 m= n b= n corr= PE Channel Enter Enter Enter Enter Enter Enter Enter Enter Data incomplete Data incomplete PE-Cy™5 Enter Filter: Enter PMT voltage: Bead Intensity % Blank 0 Bead #1 Bead #2 Bead #3 26.82 Bead #4 39.67 Bead #5 58.48 Bead #6 75.20 Bead #7 100.00 2 Regression Coefficient (r ) Detection Threshold (%) Vio-525 Enter Enter Intensity % 0 Bead #1 9.45 Bead #2 15.57 Bead #3 29.76 Bead #4 44.82 Bead #5 70.04 Bead #6 87.13 Bead #7 100.00 Regression Coefficient (r2) Detection Threshold (%) Filter: PMT voltage: Enter Enter Enter Enter Enter Enter Enter Enter Enter Filter: Enter PMT voltage: Rqd7 beads Mod Factor Bead Intensity % x^2 y y^2 x*y Blank 0 Bead #1 12.46 Bead #2 21.91 Bead #3 32.48 Bead #4 48.73 Bead #5 69.55 Bead #6 84.16 Bead #7 100.00 2 Regression Coefficient (r ) 0 0 0 0 0 count0 Detection Threshold (%) m= n b= n corr= Channel Enter Enter Enter Enter Enter Enter Enter Enter Data incomplete Data incomplete Rqd 7 beads Mod Factor x^2y y^2x*y 0 0 0 0 0 count0 m= n b= n corr= APC Channel Enter Enter Enter Enter Enter Enter Data incomplete Data incomplete Enter Filter: Enter PMT voltage: Rqd5 beads Mod Factor Bead Intensity % x^2 y y^2 x*y Blank 0 Bead #1 6.95 Bead #2 11.50 Bead #3 19.63 Bead #4 29.66 Bead #5 46.27 Bead #6 65.69 Bead #7 100.00 2 Regression Coefficient (r ) 0 0 0 0 0 count0 Detection Threshold (%) m= n b= n corr= Channel Enter Enter Enter Enter Enter Enter Enter Enter Data incomplete Data incomplete Rqd 7 beads Mod Factor x^2y y^2x*y 0 0 0 0 0 count0 m= n b= n corr= APC-Cy™7 Enter Filter: Enter PMT voltage: Bead Intensity % Blank 0 Bead #1 Bead #2 9.65 Bead #3 18.48 Bead #4 28.13 Bead #5 44.13 Bead #6 63.57 Bead #7 100.00 Regression Coefficient (r2) Detection Threshold (%) Channel Enter Rqd 6 beads Mod Factor x^2y y^2x*y Enter Enter Enter Enter Enter Enter Data incomplete Data incomplete 0 0 0 0 0 count0 m= n b= n corr= Instrument Set up: Quantum™ QC may be used to set up the window of analysis for detectors by positioning a specific peak at a target channel value. Percentage assignments were made as an LSR II (FACSDiVa) with the following optics. Dichroic mirror Bandpass filter VIO 450 - 450/50 VIO 525 555 LP 525/50 FITC 505 LP 530/30 PE 555 LP 575/26 PE - Cy™ 5 635 LP 670/14 - 660/20 735 LP 780/60 Laser 405nm 488nm 633nm Detector APC APC - Cy™7 NOTE: Due to the nature of fluorescence detectors (cytometer) and fluorescence carryover (fluorophores), we anticipate varying resolution capabilities for different detectors. This is reflected in the example histograms provided in “Expected Results,” page 2, as well as the QuickCal Linearity template (Fig. 1), which features channels in which the blank and a minimum of 5 fluorescence peaks were resolved. 9025 Technology Dr. Fishers, IN 46038 • www.bangslabs.com • [email protected] • 317.570.7020 • fax 371.570.7034 PDS 725 Rev. #005, Active: 11/Nov/2016 Page 1 of 2 PDS 725 Figure 2 : Expected Results (LSRII, FACSDiVa) Note: For additional detectors ( e.g. U V and green lasers), see PDS 725A www.bangslabs.com. 25 50 Count 75 100 200 150 100 0 50 SSC-H QC (1.000) 250 Quantum QC 100 FSC - H 150 200 102 250 (x 1.000) 103 104 105 104 105 104 105 104 105 PE-Cy5 40 30 10 20 Count 50 60 70 50 103 104 105 0 102 102 VIO 450 103 150 100 Count 50 102 103 104 0 0 50 25 Count 75 100 PE-Cy7 105 102 VIO 525 103 100 Count 50 100 50 0 0 Count 150 150 APC 102 103 104 105 102 FITC NOTES Manually shake bottle before use. The prepared tube may be briefly (pulse) vortexed if needed to increase % singlets. STORAGE AND STABILITY Store at 2-8˚C. Freezing, drying, or centrifuging particles may result in irreversible aggregation. This product is warranted to be stable for 12 months from the date of purchase, provided that it is handled in accordance with the manufacturer’s recommendations. The product should be stored in its opaque bottle to safeguard against photobleaching. SAFETY This particle suspension contains sodium azide. Sodium azide may react with lead and copper plumbing to form explosive metal azides. Upon disposal of material, flush with a large volume of water to prevent azide accumulation. Please consult the Safety Data Sheet for more information. 103 PE TRADEMARKS 1. 2. 3. 4. Quantum™ QC is a trademark of Bangs Laboratories, Inc. QuickCal® is a registered trademark of Bangs Laboratories, Inc. Tween® is a registered trademark of ICI Americas, Inc. Cy™ is a trademark of GE Healthcare Limited. This product is for research use only and is not intended for use in humans or for in vitro diagnostic use. ORDERING INFORMATION Cat. Code 725 Description Quantum™ QC, 8 Peak Beads Size 5mL Order online anytime at www.bangslabs.com. 9025 Technology Dr. Fishers, IN 46038 • www.bangslabs.com • [email protected] • 317.570.7020 • fax 371.570.7034 PDS 725 Rev. #005, Active: 14/Nov/2016 Page 2 of 2
© Copyright 2026 Paperzz