Precise BioMatch Standard.pdf

Precise BioMatch Standard 1.0
•
FINGERPRINT MATCHING SOFTWARE FOR PC ENVIRONMENTS
•
OPTIMIZED FOR SECURE ONE-TO-ONE MATCHING
•
SUPPORTS THE BIOAPI1 STANDARD
•
DOVETAILS EASILY WITH ALL BIOAPI COMPLIANT SOFTWARE
•
USER FRIENDLY GRAPHICAL USER INTERFACE
•
EASY INSTALLATION
Precise BioMatch™ Standard makes it possible to replace a password with fingerprint
authentication when, for instance, logging onto computers. Security and convenience
is assured by the Precise fingerprint matching algorithm, Precise BioMatch™, and a
user-friendly Graphical User Interface (GUI).
Support for the leading biometric standard, BioAPI, gives full interoperability and
flexibility. Together with a Precise 100 reader and a BioAPI application, Precise
BioMatch™ Standard makes it possible to use a fingerprint where before a password
was required.
The patented matching algorithm Precise BioMatch is optimized for secure one-toone matching. Based on advanced image processing, Precise BioMatch™ extracts
unique information from the fingerprint. This gives a low False Acceptance Rate
(FAR) and makes the algorithm less sensitive to distortion.
The Precise BioMatch™ Standard enrollment Graphical User Interface (GUI)
1
BioAPI is a high-level biometric Application Programming Interface (API) that brings platform and device independence to
application programmers and biometric service providers.
020808
SPECIFICATIONS
Product
Information
SPECIFICATIONS
PRODUCT DEFINITION – Precise BioMatch™ Standard
•
The matching algorithm Precise BioMatch
•
Precise 100 Drivers
•
BioAPI Framework
•
Precise Graphical User Interface (GUI)
•
Installation application
•
Maintenance Package (optional)
FEATURES
•
Fingerprint matching software for PC environments
•
Supports the BioAPI standard
•
Dovetails easily with all BioAPI compliant software
•
Optimized for secure one-to-one fingerprint matching
•
User friendly Graphical User Interface (GUI)
•
Easy installation
TECHNICAL SPECIFICATIONS
•
Template size: 558 bytes/fingerprint
•
FAR2: 1:300,000
•
FRR3: 1:100
SYSTEM REQUIREMENTS
•
Windows XP, Windows 2000, Windows NT, Windows 98 or
Windows ME
•
Precise 100 MC, Precise 100 SC, Precise 100 A, Precise 100 SC BioKeyboard or
Precise 100 A BioKeyboard
•
BioAPI application
2
FAR defines False Acceptance Rate. The measurement is performed with a database large enough to prove data statistically. The
fingerprints are captured from users with different levels of experience with biometrics.
3
FRR defines False Rejection Rate, where as one failure counts as a false reject. The measurement is performed with a database large
enough to prove data statistically. The fingerprints are captured from users with different levels of experience with biometrics.
All specifications are subject to change without notice.
Sweden:
Precise Biometrics AB, Scheelevägen 19 C, SE-223 70 Lund
Phone: +46 46 311 100 Fax: +46 46 311 101 [email protected]
Precise Biometrics AB, Finlandsgatan 66 2nd floor, SE-164 74 Kista
Phone: +46 8 632 33 50 Fax: +46 8 632 33 55 [email protected]
www.precisebiometrics.com
USA:
Precise Biometrics Inc, 8300 Boone Boulevard, Suite 500 Vienna, VA 22182
Phone: +1 (703) 848-9266 Fax: +1 (703) 832-0577 [email protected]
Product