NOTICE OF FIRE SAFETY INSPECTION OREGON STATE UNIVERSITY Facility Inspected: RICHARDSON HALL Inspection Date: 07/19/2013 Reinspect Date/Time: 08/29/2013 @ 10:10 am A fire safety inspection of the facility listed above was performed by the Corvallis Fire Prevention Bureau. These fire safety deficiencies could result in a fire or jeopardize the safety of those occupying the facility. Please see that these items are corrected immediately. If you have any questions regarding this inspection, please phone me at 737-3066. Thank you for your cooperation and support for fire safety. Jim Patton, Fire Prevention Officer, [email protected] Note: Deficiencies that are bold and underlined remain uncorrected from the last fire/life safety inspection(s) and should be corrected immediately. * Annotates a deficiency identified by OSU Environmental Health and Safety Department. Direct any questions regarding these items to that office (737-2273). Indicated on the report are items which should be correct by the Departments (DEPT) that occupy this building, Facilities Services (FS), Environmental Health and Safety (EHS), and Recycling (RECY). Please forward a copy of this report to the responsible group(s) and begin corrective action to be completed no later than the reinspection date. Facilities Services Priority Codes: Priority 1: (p1) items are considered immediate safety hazards and should be corrected within 48 hours of notification if possible. If repairs cannot be made immediately, temporary measures may be taken. Priority 2: (p2) items should be corrected within the five-week period before the scheduled reinspection. Priority 3: (p3) items are long term fixes that should be either added to an ongoing work list (such as annual testing of building sprinkler systems) or to the capital improvement list for campus upgrades. The due date is listed at the top of this page. If you have any questions, require additional information, or feel the items have been improperly assigned, feel free to contact Jim Patton (Corvallis Fire Department) at 737-3066. If assistance is required from Facilities Services to estimate or correct an item assigned to a Department, contact the Work Coordination Center at ext. 7-2969. MS Excel format is available upon request. Completed? Priority [] [] 2 2 Responsible Location Description Party FS DEPT Code Reference Notes Fire doors/smoke barriers shall be maintained and kept Near 354 CFC 703.2 free of obstructions. Doors shall close and latch unaided. Hallway fire door. One door catches on the other when closing. 0389B Discontinue using household use only fans for continual cooling. Use commercial grade metal component fans. Household Use Fans [] 2 FS 0387 [] 2 DEPT 0387 Secure compressed gas cylinders. DEPT 0387 Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. FS Extinguishers shall be tagged and inspected Through annually. Recharge CFC 906.2, out every 6 years. NFPA 10 Hydrotest every 12 years. [] [] 2 2 OFC 3807.3 Fire extinguishers on floor. Inspect and tag then either mount them, remove them or store them away if used in the field. CFC 3003.3.3 To timer equipment Completed? Priority Responsible Location Description Party [] 2 DEPT 0382 Secure compressed gas cylinders. CFC 3003.3.3 [] 2 DEPT 0373 Secure compressed gas cylinders. CFC 3003.3.3 Code Reference Notes [] 2 DEPT 0373 Provide approved pressure regulators on NFPA 45, Chpt. all compressed gas 11.1.5.2 cylinders. [] 2 DEPT 0367 Secure compressed gas cylinders. [] 2 FS 0359 2 [] [] 2 2 CFC 3003.3.3 OFC 3807.3 0359 All sprinkler valves shall be supervised/locked in CFC 510.1, the open position, 901.6, 903.4, accessible, and NFPA 13 unobstructed. Door to control room shall be signed. FS Roof Identify lab exhaust fans, stacks, and discharge vents as to laboratory or work area being served. Also include "WARNING Chemical lab exhaust" or similar. RECY Combustible recycling containers Hallway shall not be placed in CFC 316.5 Alcoves exitways. Containers may be placed in nonhazardous rooms. DEPT Install "ROOF ACCESS" sign Provide clear access to roof access ladder and fire sprinkler controls. NFPA 45, Chpt. 13.2 Provide approved recycling containers or relocate containers put of hallway. Completed? Priority [] [] [] 2 2 2 Responsible Location Description Party FS Fire doors/smoke barriers shall be maintained and kept Near 303 CFC 703.2 free of obstructions. Doors shall close and latch unaided. DEPT Knox box shall be provided for buildings Near 319 CFC 506.1 with fire alarms or sprinkler systems. Adjust doors to close and latch unaided. OFC 3807.3 Label fire sprinkler control valves as to area serve d by valve. OFC 3807.3 Clean out toaster oven. 2 FS [] 1 DEPT 0223 [] 2 Discontinue the use of non-fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. 0301N [] 2 Adjust door to close and latch unaided. DEPT Middle of Building Fire Sprinkle r Closets [] Code Reference Notes DEPT DEPT Near 201A Fire doors/smoke barriers shall be maintained and kept CFC 703.2 free of obstructions. Doors shall close and latch unaided. 0263 Discontinue the use of non-fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. Adjust fire door to close and latch unaided. Completed? Priority [] [] [] [] 2 2 2 2 Responsible Location Description Party FS 0259 OSHA, Division Portable Ladders are 2 requirement, OSHA approved and http://oregonstat in good condition, e.edu/ehs/sites/d steps and side rail efault/files/pdf/s joints tight i/ladder_safety_ si037.pdf DEPT Between first & second floor Fire doors/smoke barriers shall be maintained and kept CFC 703.2 free of obstructions. Doors shall close and latch unaided. 0133 Portable Ladders are OSHA approved and in good condition, steps and side rail joints tight FS FS Provide approved pressure regulators on NFPA 45, Chpt. all compressed gas 11.1.5.2 cylinders. 2 DEPT 0146 [] 2 DEPT 0146 2 FS 0197 Stairwell near elevator. Adjust fire doors to close and latch unaided. OSHA, Division 2 requirement, http://oregonstat e.edu/ehs/sites/d efault/files/pdf/s i/ladder_safety_ si037.pdf Inspect and test fire alarm system in accordance with CFC 907.2, nationally recognized NFPA 72 standards. Affix inspection tag to system. [] [] Code Reference Notes OFC 3807.3 Discard old fan OFC 3807.3 Provide a 10 lb. ABC dry chemical fire extinguisher near CO2 extinguisher. Completed? Priority [] [] [] 2 2 2 Responsible Location Description Party Code Reference Notes FS Sprinklers - Inspect and tag annually; flow test and tag every 5 years. CFC 906.6.1, NFPA 25 DEPT Label all chemical containers (1 gallon and larger) as to plain language contents & associated hazard. *All containers should be labeled. CFC 2703.5.1, http://oregonstat e.edu/ehs/sites/d efault/files/pdf/s i/chemical_stora ge_guidelines_s i030.pdf FS 0197A Near 197A OFC 3807.3 Provide an appropriate wrench to fire sprinkler head box. [] 2 FS 0154 OFC 3807.3 Securely attach metal shelving units to wall. [] 2 FS South Entry OFC 3807.3 Recolor fire alarm zone map. FS Knox box shall be provided for buildings Near 193 CFC 506.1 with fire alarms or sprinkler systems. Adjust fire door to close and latch unaided. Provide approved fire resistive sheathing material and allow for fire sprinkler protection inside of enclosure. [] 2 [] 2 DEPT 0173 [] 2 DEPT 0165 OFC 3807.3 Secure compressed gas cylinders. CFC 3003.3.3 Completed? Priority [] 2 Responsible Location Description Party FS Code Reference Notes Fire doors/smoke barriers shall be maintained and kept Near 163 CFC 703.2 free of obstructions. Doors shall close and latch unaided. Adjust fire doors to not jamb and close and latch unaided.
© Copyright 2025 Paperzz