NOTICE OF FIRE SAFETY INSPECTION OREGON STATE UNIVERSITY Facility Inspected: DEARBORN HALL Inspection Date: 09/04/2014 Reinspect Date/Time: 10/15/2014 @ 9:30 AM A fire safety inspection of the facility listed above was performed by the Corvallis Fire Prevention Bureau. These fire safety deficiencies could result in a fire or jeopardize the safety of those occupying the facility. Please see that these items are corrected immediately. If you have any questions regarding this inspection, please phone me at 737-3066. Thank you for your cooperation and support for fire safety. Jim Patton, Fire Prevention Officer, [email protected] Note: Deficiencies that are bold and underlined remain uncorrected from the last fire/life safety inspection(s) and should be corrected immediately. * Annotates a deficiency identified by OSU Environmental Health and Safety Department. Direct any questions regarding these items to that office (737-2273). Indicated on the report are items which should be correct by the Departments (DEPT) that occupy this building, Facilities Services (FS), Environmental Health and Safety (EHS), and Recycling (RECY). Please forward a copy of this report to the responsible group(s) and begin corrective action to be completed no later than the reinspection date. Facilities Services Priority Codes: Priority 1: (p1) items are considered immediate safety hazards and should be corrected within 48 hours of notification if possible. If repairs cannot be made immediately, temporary measures may be taken. Priority 2: (p2) items should be corrected within the five-week period before the scheduled reinspections. Priority 3: (p3) items are long term fixes that should be either added to an ongoing work list (such as annual testing of building sprinkler systems) or to the capital improvement list for campus upgrades. The due date is listed at the top of this page. If you have any questions, require additional information, or feel the items have been improperly assigned, feel free to contact Jim Patton (Corvallis Fire Department) at 737-3066. If assistance is required from Facilities Services to estimate or correct an item assigned to a Department, contact the Work Coordination Center at ext. 7-2969. MS Excel format is available upon request. Completed? Priority [] [] 2 2 Responsible Location Party Description Code Reference EHS Near 500 Extinguishers shall be tagged and inspected annually. Recharge every 6 years. Hydrotest every 12 years. CFC 906.2, NFPA 10 DEPT Remove storage and obstructions from exits, aisles, corridors, and stairs. Fourth Floor EXITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. CFC 315.2.2, 1027, Remove material http://surpl from landing us.oregonst ate.edu/spr CFC 315.2.2, 1027, Remove material http://surpl from hallway. us.oregonst ate.edu/spr [] 2 DEPT Near 302 Remove storage and obstructions from exits, aisles, corridors, and stairs. EX ITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. [] 2 DEPT 0302A Secure compressed gas cylinders. CFC 3003.3.3 0301A Replace protective caps on all high pressure cylinders not actively in use. CFC 3003.4 0310 Plug power strips directly into outlet. Do not chain one to another. CFC 605.4.2 [] [] 2 2 DEPT DEPT Notes Completed? Priority [] [] [] [] 2 2 2 2 Responsible Location Party Description FS 0300A OSHA, Division 2 requirement Portable Ladders are , OSHA approved and http://orego Remove wooden in good condition, nstate.edu/e ladders steps and side rail hs/sites/def joints tight ault/files/pd f/si/ladder_ safety_si03 7.pdf 0300C Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. 0300 Discontinue holding door to hallway near Fire doors/smoke stairwell open in barriers shall be unapproved maintained and kept manner. If doors CFC 703.2 free of obstructions. bends to remain Doors shall close and open investigate latch unaided. installed approved hardware through Facility Services. 0312 Secure cryogenic containers and provide adequate ventilation (1 CFM per sq. ft.) that will prevent the accumulation of vapor. Verify ventilation with EH&S. DEPT DEPT DEPT Code Reference CFC 3203.5.2, 3205.4.1.1 Notes Secure cryogenic tank properly. Completed? Priority [] [] [] [] [] 1 2 2 2 2 Responsible Location Party FS DEPT DEPT DEPT DEPT Description Code Reference Notes Stairwell near 310 Fire protection or detection systems shall be extended, CFC 901.4 altered, or repaired as necessary to maintain protection. 0201 Install or update hazard placard outside of lab with EH&S approved placard to identify associated hazards and emergency contact information. NFPA 45, Chpt. 13.1.1, http://orego Remount placard nstate.edu/e hs/LabHaz Sign 0201 Install or update hazard placard outside of lab with EH&S approved placard to identify associated hazards and emergency contact information. NFPA 45, Chpt. 13.1.1, http://orego Remount placard nstate.edu/e hs/LabHaz Sign 0201 Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. Near 220 Remove storage and obstructions from exits, aisles, corridors, and stairs. EXITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. Remove nest material from around both sprinkler heads. CFC 315.2.2, 1027, Remove material http://surpl from hallway. us.oregonst ate.edu/spr Completed? Priority [] [] [] [] [] [] 2 2 2 2 2 2 Responsible Location Party Description RECY Near 220 Combustible recycling containers shall not be placed in CFC 316.5 exitways. Containers may be placed in non hazardous rooms. 0202D Extinguishers shall be tagged and inspected annually. Recharge every 6 years. Hydrotest every 12 years. 0206 Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse pro tected power strips are acceptable. RECY Near 214 Combustible recycling containers shall not be placed in CFC 316.5 exitways. Containers may be placed in non hazardous rooms. DEPT Remove storage and obstructions from exits, aisles, corridors, and stairs. Right of 206 EXITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. EHS DEPT FS 0208 Code Reference Notes Remove bags from building. RECURRING ISSUE CFC 906.2, NFPA 10 CFC 315.2.2, 1027, Remove material http://surpl from hallway. us.oregonst ate.edu/spr Electrical appliances, equipment, fixtures, and facilities shall be CFC 605 used and installed in accordance with their listing. Check wiring to installed work station power strip. Loose/disconnect ed. Completed? Priority Responsible Location Party Description Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. [] 2 DEPT 0209 [] 2 DEPT 0105 Code Reference OFC 3807.3 Notes Reduce combustible fuel load in this room. [] 2 DEPT Near 104 Remove storage and obstructions from exits, aisles, corridors, and stairs. EXITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. [] 2 FS 0118 Provide/maintain exit sign. CFC 1011 Replace bulbs in old Exit signs 0118 Repair exit door/hardware. CFC 1008.1 Repair exit door to hallway that drags on floor. [] 2 FS CFC 315.2.2, 1027, Remove table http://surpl from hallway. us.oregonst ate.edu/spr Completed? Priority [] [] [] 1 2 2 Responsible Location Party Description DEPT Basement EXCESSIVE ACCUMULATI ON OF MATERIAL IN HALLWAY/EXI T PATH. MOST ALL OF THIS MATERIAL Remove storage and NEEDS TO BE obstructions from CFC REMOVED. I exits, aisles, 315.2.2, AM FREE TO corridors, and stairs. 1027, DISCUSS THE EXITWAYS http://surpl POSSIBLE SHALL BE KEPT us.oregonst EXCEPTION TO CLEAR AT ALL ate.edu/spr A FEW NON TIMES. COMBUSTIBLE , NONE MOVEABLE ITEMS. THI S NEEDS TO BE RESOLVED IMMEDIATELY . 0009 Laboratory Safety Quick Reference Guide posted in each lab area. (These can be obtained from EH&S) OSHA, Division 2 requirement , http://orego nstate.edu/e hs/sd0081 0001D Laboratory Safety Quick Reference Guide posted in each lab area. (These can be obtained from EH&S) OSHA, Division 2 requirement , http://orego nstate.edu/e hs/sd0081 DEPT DEPT Code Reference Notes Completed? Priority [] [] [] [] [] 2 2 2 2 2 Responsible Location Party DEPT FS DEPT FS DEPT Description Code Reference Notes CFC 3003.3.3 Secure cylinder with a non/limited combustible material such as chain. Plastic zip ties are not acceptable. 0001E Secure compressed gas cylinders. 0001B OSHA, Division 2 requirement Portable Ladders are , OSHA approved and http://orego in good condition, nstate.edu/e steps and side rail hs/sites/def joints tight ault/files/pd f/si/ladder_ safety_si03 7.pdf 0002 Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent Multiple 605.5 wiring. Fuse protected power strips are acceptable. 0002 Provide cover plates on all electrical CFC 605.6 outlets, switches, and junction boxes. Electrical panel 140 - cover circuit blanks in approved manner 0002 Extinguishers shall be visible or signed, easily accessible, CFC 906, mounted with the NFPA 10, bottom not less than ADA 4 inches nor the top more than 4 feet above the floor. Remove obstruction to extinguisher Completed? Priority [] 3 Responsible Location Party FS Description 0002 Provide/maintain exit sign. Code Reference Notes CFC 1011 Add combo EXIT sign over double doors out of this room. ADD TO EXIT SIGN I INSTALLATION LKST. [] 2 DEPT 0001G Homemade electrical appliances shall be inspected, approved, Discard and tagged by CFC 605.7 homemade 4-plex Facility Services extension cord Electrical Shop before continued use. [] 2 DEPT Near 8 Provide/maintain exit sign. [] [] 1< td>DEP Near 8 T 2 DEPT CFC 1011 Remove storage and obstructions from exits, aisles, corridors, CFC 315.2.2, 1027, Move spare and stairs. http://surplus.oregon door out of EXITWAY state.edu/spr hallway S SHALL BE KEPT CLEAR AT ALL TIMES. Near 7 Remove storage and obstructions from exits, aisles, corridors, and stairs. EXITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. CFC 315.2.2, 1027, http://surpl us.oregonst ate.edu/spr Bad battery Completed? Priority [] [] [] [] [] 2 2 2 2 2 Responsible Location Party Description DEPT Near 3A Electrical appliances, equipment, fixtures, and facilities shall be CFC 605 used and installed in accordance with their listing. Blue electrical cord - secure cord to plug 0003 Electrical appliances, equipment, fixtures, and facilities shall be CFC 605 used and installed in accordance with their listing. Under "Terminal Box" - Replace appliance cord that has insulation coming apart and cord is very brittle. Near 6 Remove storage and obstructions from exits, aisles, corridors, and stairs. EXITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. CFC 315.2.2, Discontinue 1027, storing bicycles http://surpl in hallway. us.oregonst ate.edu/spr Near 5B Remove storage and obstructions from exits, aisles, corridors, and stairs. EXITWAYS SHALL BE KEPT CLEAR AT ALL TIMES. CFC 315.2.2, 1027, Remove material http://surpl from hallway. us.oreg onstate.edu/ spr 0005 Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. FS DEPT DEPT DEPT Code Reference Notes Completed? Priority [] 2 Responsible Location Party Description DEPT Discontinue the use of non fuse protected extension cords in CFC 605.4, place of permanent 605.5 wiring. Fuse protected power strips are acceptable. 0006 Code Reference Notes
© Copyright 2026 Paperzz