Cisco Nexus 5000 Series NX-OS Upgrade and
Downgrade Guide, Release 5.0
This document describes how to upgrade or downgrade Cisco NX-OS software on Cisco Nexus 5000 Series
switches and Cisco Nexus 2000 Series Fabric Extenders.Use this document in combination with documents
listed in the“Related Documentation” section on page 38.
This document includes these sections:
•
Information About Software Images, page 1
•
Supported Hardware, page 2
•
Upgrade Guidelines, page 3
•
Using The install all Command, page 4
•
In-Service Software Upgrades, page 6
•
Upgrading Procedures, page 19
•
Disruptive Installation Process, page 28
•
Forcing an Upgrade, page 28
•
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier Releases (Disruptive Upgrade),
page 29
•
Monitoring the Upgrade Status, page 36
•
Downgrading From a Higher Release, page 37
•
Troubleshooting ISSUs and Disruptive Installations, page 38
•
Related Documentation, page 38
Information About Software Images
Cisco Nexus 5000 Series switches are shipped with the Cisco NX-OS software pre-installed on the
switches. Before upgrading or downgrading from an existing image, you should read through the
information in this document to understand the guidelines, prerequisites, and procedures for upgrading
software. For updated information about the Cisco NX-OS software for the Cisco Nexus 5000 Series
switch, see the Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Fabric Extender Release Notes.
Americas Headquarters:
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Supported Hardware
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
The Cisco NX-OS software consists of the kickstart image and the system image. The system image
includes software for the Cisco Nexus 5000 Series switch and the Cisco Nexus 2000 Series Fabric
Extenders that are connected to the switch. The images contain a major release identifier, a minor release
identifier, and a maintenance release identifier, and they can also contain a rebuild identifier, which may
also be referred to as a support patch. “Figure 1Cisco NX-OS Version Identifies” section on page 2
shows the version identifiers that are used with a combination of platform-independent and
platform-dependent schemes for Cisco NX-OS software.
Figure 1
Cisco NX-OS Version Identifies
The platform designator is N for the Nexus 5000 Series Switches, E for the Nexus 4000 Series Switches,
and S for the Nexus 1000 Series Switches. Applicable features, functions, and fixes in the platform
independent code are present in the platform dependent release, in figure above, applicable fixes in Cisco
NX-OS Software Release 4.0(1a) are present in the 4.0(1a)N1(1a) release.
Supported Hardware
Cisco Nexus 5000 Series switches are shipped with the Cisco NX-OS software pre-installed. Cisco
NX-OS upgrades and downgrades are supported on the following hardware:
Cisco Nexus 5000 Series Switches and Associated Expansion Modules
•
Cisco Nexus 5000 2RU Chassis (N5K-C5020P-BF)
•
Cisco Nexus 5000 1RU Chassis (N5K-C5010P-BF)
•
Cisco Nexus 5000 Series Module 6-port 10 Gigabit Ethernet (N5K-M1600)
•
Cisco Nexus 5000 Series Module 4x10GE 4xFC 4/2/1 (N5K-M1404)
•
Cisco Nexus 5000 Series Module 6xFC 8/4/2/1 (N5K-M1060)
•
Cisco Nexus 5000 Series Module 8xFC 4/2/1 (N5K-M1008)
Cisco Nexus 5500 Platform Switches and Associated Expansion Modules
•
Cisco Nexus 5500 1RU Chassis (N5K-C5548P-FA)
•
Cisco Nexus 5500 Series 8x10GE 8xFC 8/4/2/1 (N55-M8P8FP)
•
Cisco Nexus 5500 Series 16-port 10GE (N55-M16FP)
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
2
OL-24969-01
Upgrade Guidelines
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Cisco Nexus 2000 Series Fabric Extenders
•
Cisco Nexus 2148T Fabric Extender
•
Cisco Nexus 2248TP Fabric Extender
•
Cisco Nexus 2224TP Fabric Extender
•
Cisco Nexus 2232PP Fabric Extender
Upgrade Guidelines
When upgrading system software, follow these guidelines:
•
Configuration Changes
You cannot enter configuration mode during an upgrade. You should save, commit, or discard any
active configuration sessions before upgrading or downgrading the Cisco NX-OS software image.
The active configuration session is deleted without warning during a reload.
Use the show configuration session summary command to verify that there are no active
configuration sessions.
switch# show configuration session summary
There are no active configuration sessions
For more information on configuration sessions, see the Cisco Nexus 5000 Series System
Management Configuration Guide.
Note
•
CLI and SNMP configuration change requests are denied during an ISSU.
Topology Changes
You should make topology changes such as STP or FC fabric changes that affect zoning, Fabric
Shortest Path First (FSPF), or FC domains before you perform an upgrade. You should perform
module installations or removals only before or after an upgrade.
•
Scheduling
You should upgrade when your network is stable and steady. Ensure that everyone who has access
to the switch or the network is not configuring the switch or the network during this time. You cannot
configure a switch during an upgrade.
•
Space
Verify that sufficient space is available in the location where you are copying the images. The
internal bootflash requires approximately 200 MB of free space.
•
Hardware
Avoid power interruptions during an install procedure. Power interruptions can corrupt the software
image.
•
Connectivity to Remote Servers
Configure the IPv4 address or IPv6 address for the 10/100/1000 BASE-T Ethernet port connection
(interface mgmt0). Ensure that the switch has a route to the remote server. The switch and the remote
server must be in the same subnetwork if you do not have a router to route traffic between subnets.
•
Software Images
Ensure that the specified system and kickstart images are compatible with each other as follows:
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
3
Using The install all Command
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
•
If the kickstart image is not specified, the switch uses the current running kickstart image.
•
If you specify a different system image, ensure that it is compatible with the running kickstart image.
•
Retrieve compatible images in one of two ways:
– Locally—Images are locally available on the switch.
– Remotely—Images are in a remote location and you specify the destination using the remote
server parameters and the filename to be used locally.
•
Commands
Use the following commands to prepare for and install the new software:
•
Use the ping command to verify connectivity to the remote server.
•
Use the dir command to verify the required space is available for the image files to be copied.
•
Use the show install all impact command to identify the upgrade impact. This command displays
information describing the impact of the upgrade on each Fabric Extender such as the current and
upgrade-image versions. This command also displays if the upgrade is disruptive or the reason why
the upgrade is disruptive and if the Fabric Extender needs to be rebooted, and the reason why it needs
to be rebooted.
We recommended that you log in to the console port to begin the upgrade process. In vPC topologies,
the first upgrade can be performed on either the primary or secondary switch in the topology
•
Terminology
Table 1-1 summarizes the terms used in the install all command output to verify module and
software image compatibility.
Table 1-1
install all Commands and Output Terminology
Term
Definition
bootable
The ability of the module to boot or not boot based on image compatibility.
Impact
The type of software upgrade mechanism—disruptive or nondisruptive.
install-type reset
Resets the module.
sw-reset
Resets the module immediately after a switchover.
rolling
Upgrades each module in sequence.
copy-only
Updates the software for BIOS, loader, or bootrom.
force
Option to force a disruptive upgrade, even when ISSU is possible
Using The install all Command
The install all command triggers the ISSU on Cisco Nexus 5000 Series switches and Cisco Nexus 2000
Series Fabric Extenders. The following images are upgraded during the installation:
•
Kickstart image
•
System image
•
Fabric Extender image
•
System BIOS
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
4
OL-24969-01
Upgrading the BIOS and Power Sequencer Images
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
•
Power-sequencers on the system
The install-all command provides the following benefits:
•
You can upgrade the Cisco Nexus 5000 Series switches and the Nexus 2000 Series Fabric Extenders
using just one command.
•
You can receive descriptive information about the intended changes to your system before you
continue with the installation. For example, it identifies potential disruptive upgrades.
•
You can continue or cancel the upgrade when you see this question (the default is no):
Do you want to continue (y/n) [n] : y
•
You can upgrade the Cisco NX-OS software using a non-disruptive procedure, when supported.
•
The command automatically checks the image integrity, which includes the running kickstart and
system images. The command sets the kickstart and system boot variables.
•
The command performs a platform validity check to verify that a wrong image is not used.
•
The Control + C escape sequence gracefully ends the install all command. The command sequence
completes the update step in progress and returns to the EXEC prompt.
•
After issuing the install all command, if any step in the sequence fails, the upgrade ends.
•
The following message appears to warn you about the impact of upgrading the power sequencer:
Warning: please do not remove or power off the module at this time.
Note: Power-seq upgrade needs a power-cycle to take into effect.
Note
After a successful power sequence upgrade, you must switch off the power to the system and
then, power it up.
•
You can force a disruptive upgrade. For information on forcing an upgrade, see Forcing an Upgrade.
Upgrading the BIOS and Power Sequencer Images
Changes to BIOS and power-sequencers are rare; however, when they occur, they are included in the
NX-OS system image and the BIOS and power sequencer are upgraded as during the install process. The
summary displayed by the installer during the installation process indicates the current version of the
BIOS and power sequencer and the target version.
Note
After a successful power sequence upgrade, you must switch off the power to the system and
then, power it up.
Impact of Upgrades and Downgrades
NX-OS supports a technology called In-Service Software Upgrade (ISSU) that allows a Cisco Nexus
5000 Series switches and any connected FEXs to be upgraded without any traffic disruption (with a brief
control plane disruption). A few conditions have to be met for the system to be upgraded via ISSU
process – the access layer topology should be ISSU compliant, the current and target versions should be
ISSU capable and the network should be stable. Please see sections on ISSU for more details.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
5
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
In the case where the conditions required for ISSU are not met or if the user intends to downgrade the
software version, the installation process will be disruptive – Cisco Nexus 5000 Series switch and any
connected FEX will be rebooted, causing a disruption. If Cisco’s Virtual Port-Channel (vPC) technology
is configured on Cisco Nexus 5000 Series switches, it is possible to achieve an upgrade/downgrade with
very minimal traffic disruption to servers/hosts. Please see the section on Minimizing traffic disruption
during a non-ISSU installation process for more details.
In-Service Software Upgrades
ISSU stands for In-Service Software Upgrade. Support for ISSU on Cisco Nexus 5000 Series switches
and Cisco Nexus 2000 Series Fabric Extenders was added with the 4.2(1)N1(1) NX-OS software release.
With this, it is possible to upgrade a Nexus access layer without causing any traffic disruption to servers.
Traditionally, ISSU has been supported on systems with dual-supervisors modular systems like Cisco
Nexus 7000 and Cisco Catalyst 6500. With a dual-supervisor system, it is possible to achieve ISSU via
a rolling upgrade process – upgrade the standby supervisor to the new software; failover to the standby
supervisor – this causes the control plane to run the newer version of software; upgrade the supervisor
that is now the standby (was previously active) – this upgrades both supervisors; finally, upgrade the I/O
modules or linecards. In this process, both the control plane and data plane remain available throughout
the ISSU process.
With a single supervisor system like a Cisco Nexus 5000 Series switch, ISSU process works differently,
but provides the same benefits as in a dual-supervisor system. ISSU on the Cisco Nexus 5000 Series
switch causes the supervisor CPU to reset and load the new software version. The control plane is
inactive in this duration, but the data plane keeps forwarding packets leading to an upgrade with no
service disruption. After the CPU loads the updated version of NX-OS, the system restores the control
plane to previous known configuration and runtime state and gets in-sync with the data plane, thereby
completing the ISSU process. Since the data plane kept forwarding packets while the control plane was
upgraded, any servers connected to the Cisco Nexus 5000 Series switch access layer should see no traffic
disruption.
ISSU and Layer 3
Cisco Nexus 5500 Platform switches support Layer 3 functionality. However, the system cannot be
upgraded with the ISSU process (non-disruptive upgrade) when Layer-3 is enabled. It is required to
un-configure all Layer-3 features, remove the L3 license, and reload the switch, to be able to upgrade in
a non-disruptive way with ISSU.
ISSU Supported Topologies
This section includes the following topics:
•
ISSU Support For Cisco Nexus 2000 Series Fabric Extenders, page 7
•
ISSU Support For vPC Topologies, page 7
•
ISSU Support For vPC Topologies With Fabric Extenders, page 8
•
ISSU Support With Fibre Channel and FCoE Topologies, page 8
•
Summary of ISSU-Supported Topologies, page 9
•
Summary of ISSU Unsupported Topologies, page 11
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
6
OL-24969-01
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
•
Management Services After an ISSU, page 15
•
Fiber Channel/FCoE Protocol & Services During an ISSU, page 15
ISSU Support For Cisco Nexus 2000 Series Fabric Extenders
Cisco Nexus 2000 Series Fabric Extenders act as linecards to Cisco Nexus 5000 Series switches, thereby
bringing in a lot of advantages – add flexibility to data-center networking infrastructure (simultaneous
Top-of-Rack and End-of-Row access layer) by decoupling physical and logical (Layer-2) topology,
reducing operation expense by lowering management and troubleshooting points, ability to build larger
layer-2 fabric that is loop-free – all with a single layer of switching.
The ISSU process initiated on the Cisco Nexus 5000 Series switches upgrades the entire access layer
including the switch and the FEXs that are connect to the switch.
An ISSU first upgrades the switches. Once the switch is operational with the upgraded software, the
FEXs are upgraded. This upgrade of the FEX is done in a rolling fashion – one FEX at a time. Note that
this upgrade on the Fabric Extenders is non-disruptive, similar to the upgrade of the switch.
Note: The time required for ISSU to complete depends on the number of FEXs connected. The customer
should plan a maintenance window with the total upgrade time in mind. Please note that the entire
upgrade is expected to be non-disruptive and is not expected to cause any outage to connected servers.
ISSU Support For vPC Topologies
ISSU is completely supported when two switches are paired in a vPC configuration. In a vPC
configuration, one switch functions as a primary switch and the other functions as a secondary switch –
they both run the complete switching control plane, but co-ordinate forwarding decisions to have optimal
forwarding to devices at the other end of the vPC. Additionally, the two devices appear as a single device
that supports ether-channel (static and 802.3ad) and, hence, provide simultaneously data forwarding
services to that device.
While upgrading devices in a vPC topology, it is recommended to start with the switch that is the
operational primary. The vPC secondary device should be upgraded after the ISSU process completes
successfully on the primary device. The two vPC devices continue control plane communication during
the entire ISSU process (except when the ISSU process resets the CPU of the switch being upgraded).
Use the show vpc brief command to determine the vPC operational role of the switch:
n5020-2# show vpc brief
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id
Peer status
vPC keep-alive status
Configuration consistency status
vPC role
Number of vPCs configured
Peer Gateway
Dual-active excluded VLANs
:
:
:
:
:
:
:
:
1000
peer adjacency formed ok
peer is alive
success
primary
247
Disabled
-
Status of ISSU on the primary device can be monitored from the primary device, until completion, after
the primary switch reloads by using the CLI show install all status.
Any attempt to initiate an upgrade on the vPC peer switch, when ISSU is progress on the other switch,
will be blocked.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
7
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Note
During an upgrade, the configuration on peer switches is locked and the vPC state on vPC peer switches
is suspended until the upgrade is complete.
Verifying the vPC Status on a Peer Switch During an Upgrade
To view the vPC status, enter the show vpc command on a peer switch.
switch-2# show vpc
Legend:
(*) - local vPC is down, forwarding via vPC peer-link
vPC domain id : 1000
Peer status : peer adjacency formed ok
vPC keep-alive status : Suspended during ISSU
Configuration consistency status: success
vPC role : primary, operational secondary
Number of vPCs configured : 100
Peer Gateway : Disabled
Dual-active excluded VLANs : 40
vPC Peer-link status
-----------------------------------------------id
Port
Status Active vlans
---------- ----------------------------1
Po100 up
1,40
The following message is displayed on the vPC peer switch when ISSU is started on the other switch.
2010 Feb 4 00:07:16 MN5020-4 %$ VDC-1 %$ %VPC-2-VPC_ISSU_START: Peer vPC switch ISSU
start, locking configuration
Viewing System Messages on Peer Switches
A keepalive message such as the following may appear on a peer switch during an upgrade:
2010 Feb 4 00:09:26 MN5020-4 %$ VDC-1 %$ %VPC-2-PEER_KEEP_ALIVE_RECV_FAIL: In domain
1000, VPC peer keep-alive receive has failed
Installation status messages such as the following may appear on peer switches as the primary switch is
upgraded.
switch-2# 2010 Jun 10 18:27:25 N5K2 %$ VDC-1 %$ %SATCTRL-2-SATCTRL_IMAGE: FEX100 Image
update in progress.
switch-2# 2010 Jun 10 18:32:54 N5K2 %$ VDC-1 %$ %SATCTRL-2-SATCTRL_IMAGE: FEX100 Image
update complete. Install pending
ISSU Support For vPC Topologies With Fabric Extenders
ISSU is supported in vPC topologies that include FEXs that are connected in dual-homed topologies to
a parent switch and when the FEX is in a single-homed topology.
ISSU Support With Fibre Channel and FCoE Topologies
ISSUs are supported on access layer switches when Fibre Channel and FCoE is enabled. You must ensure
that the FC fabric is stable before initiating an ISSU in this topology.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
8
OL-24969-01
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Summary of ISSU-Supported Topologies
Figure 2
Access Switch Topology
Aggregation
237879
Nexus 5000
Figure 3
vPC Peering Topology
Aggregation
Nexus 5020
237880
Nexus 5010
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
9
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Figure 4
Virtual Modular System With Static Fabric Connectivity For FEXs
Nexus 50x0
Hosts
Figure 5
Nexus 2000
237881
Nexus 2000
Hosts
Virtual Modular System
Nexus 50x0
Hosts
Nexus 2000
Hosts
237882
Nexus 2000
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
10
OL-24969-01
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Figure 6
vPC Peered Dual-Supervisor Virtual Modular System Dual-homed FEXs
Aggregation
Nexus 5020
Nexus 2000
Nexus 2000
237883
Nexus 5010
Figure 7
Vpc Peered Dual-Supervisor Virtual Modular System Dual-Homed FEXs and
Singled-Homed FEXs
Aggregation
Nexus 5020
Nexus 2000
Nexus 2000
237884
Nexus 5010
Summary of ISSU Unsupported Topologies
There are a couple of important spanning tree related requirements for a Cisco Nexus 5000 Series switch
to support ISSU. These requirements are due to the fact that a switch undergoing ISSU has its control
plane inactive while the switch is reset and the new software version is loaded. Not having these
restrictions could render the network unstable, if there are any unexpected topology changes.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
11
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
•
STP enabled switches cannot be present downstream to the switch undergoing ISSU.
•
The STP Bridge Assurance feature cannot be configured except on a vPC peer link. Bridge
Assurance is enabled by configuring an interface as spanning-tree port type network.
If the STP conditions are not met, the installation check will indicate that the upgrade would be
disruptive. In this case, you can perform an upgrade at a later time after making necessary changes to
the topology to meet these conditions or perform a disruptive upgrade.
Figure 8
Connection To A Blade Switch That Is Running Spanning Tree Protocol
237885
Nexus 5000
Blade Switches
Figure 9
Connection To A Downstream Switch That Is Running Spanning Tree Protocol
237886
Nexus 5000
Downstream switch
Figure 10
Cisco Nexus 5000 Series Switch Running Bridge Assurance With Another Switch
Aggregation
Bridge assurance
enabled
237887
Nexus 5000
undergoing
ISSU
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
12
OL-24969-01
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Figure 11
Dual-Homed FEXs Connected To A Stub Switch
Nexus 5000
237888
Nexus 2000
Figure 12
Single-Homed FEX Connected To Stub Switches
Figure 13
vPC Connection to Stub Switches
Nexus 5020
237890
Nexus 5010
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
13
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
ISSU Prerequisites
All the upgrade guidelines listed in Cisco NX-OS Upgrade Guidelines section should be strictly adhered
to for ISSU to work smoothly. In particular, it is very important to make sure that the network is stable
and no changes are made while ISSU is in progress. It is also necessary to make sure that feature
compatibility between the current running release and the target release.
Figure 14
Upgrade Restrictions
In addition, there are some specific requirements for non-disruptive upgrade (ISSU).
Topology requirements—Cisco Nexus 5000 Series switch on which ISSU is being initiated should not
be in one of the unsupported topologies listed above. In particular, there must be no switch running
spanning-tree connected downstream to the switch – in other words, there should be no interface that is
in a spanning-tree designated forwarding state. Also, bridge assurance should not be configured on any
interface of the Nexus 5000. vPC peer-link is an exception to these requirements.
Layer-2 requirement—ISSU process will be aborted if the system has any LACP fast timers
configured.
FC/FCoE requirements—It is expected that the topology is stable for ISSU to work smoothly. The
following is a list of things the administrator needs to run through to check stability. Please note that this
list is not exhaustive.
Domain Manager—As part of the install process domain manager will check if fabric is in stable state.
If a determination is made that the fabric is not stable, installation will be aborted.
CFS—As part of the install process, CFS will check if any application (ntp,fsm, rcsn, fctime, etc) is
locked. If any application is holding a CFS lock, installation will be aborted.
Zone Server—Installation process will abort if zone merge or zone change request is in progress.
FSPF—As part of the upgrade process, FSPF will verify if the configured interface dead-interval is
greater than 80 seconds, otherwise installation will abort.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
14
OL-24969-01
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Management Services After an ISSU
Prior to the switch being reset for ISSU, inband and management ports are brought down, and are
brought back up after ISSU completes. Services that depend on inband and management ports are
impacted during this time.
Table 1-2
Service
Description
Telnet/SSH
When ISSU resets the system to load the target NX-OS version, all
Telnet/SSH sessions will be disconnected and need to be re-established after
ISSU completes
AAA/RADIUS
Applications that leverage the AAA Service (such as Login) will be disabled
during ISSU process. Since all Network Management services are disabled
during this time, this behavior is consistent.
HTTP
The HTTP sessions to the Switch will be disconnected during ISSU reboot.
After ISSU reboot, the HTTP will be restarted and switch will accept HTTP
sessions after ISSU reboot.
NTP
The NTP sessions to and from the switch are disrupted during ISSU reboot.
After ISSU reboot, NTP session will be re-established based on the saved
startup configuration.
Fiber Channel/FCoE Protocol & Services During an ISSU
During an ISSU process, the control plane will be offline for up to 80 seconds. Any state changes in the
network during this time will not be processed. Depending on the change, the impact may vary. It is
always recommended to ensure a stable fabric during ISSU
Table 1-3
ISSU Impact to Fibre Channel and FCoE Services
Name Server
When a new switch in the fabric is brought up and queries the Name Server
on the ISSU switch, the ISSU switch will not be able to respond and hence
will not receive Nx_port information.
Domain Manager
Domain Manager on a switch undergoing ISSU will not process any
BF/RCF/DIA/RDI caused by topology changes, which may result in traffic
disruption in the fabric.
CFS
During ISSU upgrade, CFS applications on other switches will not be able
to obtain CFS lock on the ISSU switch, resulting in CFS distribution fail
until ISSU completes.
N-Port Virtualization
During ISSU process, NPV process is down. Any FLOGI/fdisc or logo
request from server will fail until the ISSU process has completed
Zone Server
During ISSU, since EPP and merge requests are not processed, peer switch
is not able to bring up E and TE ports connected to ISSU switch until ISSU
is completed.
Peer switch zone change request will not be answered by switch undergoing
ISSU. Any zone configuration changes on other switches connected to ISSU
switch will fail until ISSU is complete
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
15
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Table 1-3
ISSU Impact to Fibre Channel and FCoE Services
FSPF
Prior to switch rebooting for ISSU, switch will transmit FSPF hello on all
interfaces to prevent neighbor switches from marking route to ISSU switch
as down. Any topology changes during this time will also not be acted upon
until ISSU completes.
EPP
During ISSU process, EPP messages are not received/transmitted on the
ISSU switch. Hence, new ports in FC Port Channels will not be negotiated
until ISSU completes. Additionally FC Trunk Mode changes (E port to TE
Port and vice versa, allowed VSAN list) are also not processed during this
time.
Layer-2 Protocols Impact
Table 1-4
ISSU Impact to Layer 2 Protocols
LACP
IEEE 802.3ad provides for the default slow aging timers to be transmitted
once every 30 seconds in steady state and will expire after 90 seconds. ISSU
should not impact peers that rely on LACP as the recovery time is less than
90 seconds.
Please note that Fast LACP timers (hello=1 sec, dead=3 sec) is not
supported with non-disruptive ISSU.
IGMP
IGMP will not disrupt existing flows of multicast traffic that are already
present, but new flows will not be learnt (and hence will be dropped) until
ISSU completes. New router ports or changes to router ports will also not
be detected during this time.
DCBX & LLDP
DCBX uses LLDP to exchange parameters between peer devices. Since
DCBX is a link-local protocol, when the switch undergoes ISSU, the age
time is increased on all ports on switches and FEXs being upgraded.
Manual configurations are ignored during this time.
CDP
During ISSU, the time-to-live value is increased (180 seconds) if it is less
than the recommended timeout value. The configuration will be ignored if
manually specified.
Ethernet interfaces on the switch and the Fabric Extenders
To avoid link down to link up transitions during the control plane outage time, the laser is turned off for
administratively up ports that are operationally down. This situation occurs during the ISSU reboot
starting state when the switch and the FEX applications stop communicating with each other. After the
ISSU reboot and a stateful restart, the laser is turned back on. This action effectively prevents the link
state from transitioning from down to up during an ISSU.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
16
OL-24969-01
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Pre-Installation Checks
It is beneficial to do certain sanity checks to ensure that the system is ready for an ISSU and to
understand the impact of ISSU:
Note
•
Enter the show incompatibility command to verify that the target image is feature-wise compatible
with the current image
•
Enter the show install all impact command to identify the upgrade impact
•
Enter the show fex command to verify that all the FEXs are online
•
Enter the show vpc role command to verify the vPC switch role in a vPC topology
•
Enter the install all command to update to the latest Cisco NX-OS software
•
Review the installer impact analysis and choose to continue.
The switch might reload here causing traffic disruption if the upgrade is not ISSU)
•
Monitor installation progress.
•
Verify the upgrade.
•
Enter the show install all status command to verify the status of the installation
This table lists the show commands that identify the impact or potential problems that may occur when
performing an ISSU.
Table 1-5
Upgrade Show Commands
Command
Definition
show incompatibility system
Displays incompatible configurations on the current system that
will impact the upgrade version.
show install all impact
Displays information that describes the impact of the upgrade on
each Fabric Extender including the current and upgrade-image
versions. This command also displays if the upgrade is disruptive
or not and if the Fabric Extender needs to be rebooted, and the
reason why.
show spanning-tree issu-impact
Displays the spanning-tree configuration and whether or not there
are potential STP issues.
show lacp issu-impact
Displays the port priority information and whether or not there are
potential issues.
You can also perform the following tasks to identify potential problems before they occur:
•
Ensure you have enough space to store the images on bootflash:
•
Verify compatibility of new system image with current running features/configurations. Use the
show incompatibility system: command to display incompatible configurations on the current
system that will impact the upgrade version.
n5010# show incompatibility system bootflash:n5000-uk9.4.2.1.N1.1a.bin
No incompatible configurations
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
17
In-Service Software Upgrades
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
•
Verify that all the connected FEXs are online. Use the show fex command to display the status of
FEXs connected to the system:
nexus5010# show fex
FEX
FEX
FEX
FEX
Number Description
State
Model
Serial
----------------------------------------------------------------------------------------------100
FEX0100
Online
N2K-C2224TP-1GE
JAF1427BQME
101
FEX0101
Online
N2K-C2224TP-1GE
JAF1427BQMK
•
Verify that the current STP topology is consistent with ISSU requirements. Use the show
spanning-tree issu-impact command to display the STP configuration and whether or not there is
potential STP issues
nexus5010# show spanning-tree issu-impact
For ISSU to Proceed, Check the Following Criteria :
1. No Topology change must be active in any STP instance
2. Bridge assurance(BA) should not be active on any port (except MCT)
3. There should not be any Non Edge Designated Forwarding port (except MCT)
4. ISSU criteria must be met on the VPC Peer Switch as well
Following are the statistics on this switch
No Active Topology change Found!
Criteria 1 PASSED !!
No Ports with BA Enabled Found!
Criteria 2 PASSED!!
No Non-Edge Designated Forwarding Ports Found!
Criteria 3 PASSED !!
ISSU Can Proceed! Check Peer Switch.
Use the show lacp issu-impact command to display if any port or a peer switch is configured in rate
fast mode.
•
Verify that ISSU is non-disruptive. Use the show install all impact kickstart <image>
system<image> command to display the information describing the impact of the upgrade on each
FEX including details such as upgrade image versions. This command will also display if the
upgrade is disruptive/non-disruptive and the reason why.
N5K1# show install all impact kickstart bootflash:n5000-uk9-kickstart.4.2.1.N1.1a.bin
system bootflash:n5000-uk9.4.2.1.N1.1a.bin
Verifying image bootflash:/n5000-uk9-kickstart.4.2.1.N1.1a.bin for boot variable
"kickstart".
[####################] 100% -- SUCCESS
Verifying image bootflash:/n5000-uk9.4.2.1.N1.1a.bin for boot variable "system".
[####################] 100% -- SUCCESS
Verifying image type.
[###########
] 50%
[####################] 100% -- SUCCESS
Extracting "system" version from image bootflash:/n5000-uk9.4.2.1.N1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "kickstart" version from image bootflash:/n5000-uk9-kickstart.4.2.1.N
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
18
OL-24969-01
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "bios" version from image bootflash:/n5000-uk9.4.2.1.N1.1a.bin.
[####################] 100% -- SUCCESS
Extracting "fex" version from image bootflash:/n5000-uk9.4.2.1.N1.1a.bin.
[####################] 100% -- SUCCESS
Notifying services about system upgrade.
[####################] 100% -- SUCCESS
Compatibility check is done:
Module bootable
Impact
------ -------- -------------1
yes non-disruptive
100
yes non-disruptive
Install-type
-----------reset
rolling
Reason
------
Images will be upgraded according to following table:
Module
Image
Running-Version
New-Version
------ ---------- ---------------------- ---------------------1
system
4.2(1)N1(1)
4.2(1)N1(1a)
1
kickstart
4.2(1)N1(1)
4.2(1)N1(1a)
1
bios
v1.2.0(06/19/08)
v1.3.0(09/08/09)
100
fex
4.2(1)N1(1)
4.2(1)N1(1a)
1
power-seq
v1.2
v1.2
Upg-Required
-----------yes
yes
yes
yes
no
Upgrading Procedures
The ISSU process is triggered when you enter the install all command. This section describes the
sequence of events that occur when you upgrade a single Cisco Nexus 5000 Series switch or a single
Cisco Nexus 5000 Series switch that is connected to one or more FEXs. The section includes the
following topics:
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
19
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
•
Installation At-A-Glance, page 20
•
Copying the Running Configuration From an External Flash Memory Device, page 21
•
Copying the Startup Configuration From an External Flash Memory Device, page 22
•
Upgrade Process in a Non-vPC Topology, page 23
•
Upgrade Process in vPC Topology on the Primary Switch, page 27
•
Upgrade Process in vPC Topology on the Secondary Switch, page 27
•
Forcing an Upgrade, page 28
•
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier Releases (Disruptive Upgrade),
page 29
•
Minimizing the Impact of a Disruptive Upgrade, page 34
•
Upgrading A Direct Vpc Or A Single-Homed Fex Access Layer, page 34
•
Monitoring the Upgrade Status, page 36
Installation At-A-Glance
Table 1-6shows an overview of upgrade process:
Table 1-6
Upgrade Process At-A-Glance
Upgrade Preparation
Log in to the first Cisco Nexus 5000 Series switch. It is recommended that
you log in to the console port. In vPC topologies, the first upgrade can be
performed on either the primary or secondary switch in the topology
Log in to Cisco.com to access the Software Download Center. To log in to
Cisco.com, go to http://www.cisco.com/ and click Log In at the top of the
page. Enter your Cisco username and password.
Select and download the kickstart and system software files to the server
Verify that the required space is available in the bootflash: directory for the
image file(s) to be copied
If you need more space in the bootflash: directory, delete unnecessary files
to make space available
Copy the Cisco NX-OS kickstart and system images to the bootflash using
a transfer protocol such as ftp:, tftp:, scp:, or sftp:
Compare the file sizes of the images that were transferred using the dir
bootflash command. The file sizes of the images obtained from Cisco.com
and the image sizes of the transferred files should be the same
Complete above steps through Step 9 for each Cisco Nexus 5000 Series
switch in the topology
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
20
OL-24969-01
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Table 1-6
Upgrade Process At-A-Glance
Pre-ISSU Checks
Enter the show incompatibility command to verify that the target image is
feature-wise compatible with the current image
Enter the show install all impact command to identify the upgrade impact
Enter the show spanning-tree issu-impact command to display the impact
of the upgrade
Enter the show lacp issue-impact command to display the impact of the
upgrade
Enter the show fex command to verify that all the FEXs are online
Upgrade Begins
Enter the show vpc role command to verify the vPC switch role
Enter the install all command to update to the latest Cisco NX-OS software
Peruse the installer impact analysis and accept to proceed
Installer on Nexus 5000 upgrades the software – the switch will now run
new version of the software
Upgrade Verification
Enter the show install all status command to verify the status of the
installation
Copying the Running Configuration From an External Flash Memory Device
You can copy configuration files from an external flash memory device.
Note
This procedure applies to the Cisco Nexus 5500 Platform running Cisco NX-OS Release 5.0.2 and later
releases.
Before You Begin
Insert the external flash memory device into the active supervisor module.
Step 1
Command or Action
Purpose
dir {usb1: | usb2:}[directory/]
(Optional) Displays the files on the external flash
memory device.
Example:
switch# dir usb1:
Step 2
copy {usb1: | usb2:}[directory/]filename running-config
Example:
Copies the running configuration from an external
flash memory device. The filename argument is case
sensitive.
switch# copy usb1:dsn-config.cfg running-config
Step 3
copy {usb1: | usb2:}[directory/]filename running-config
Example:
(Optional) You can copy the running configuration
from an external flash memory device to the
bootflash.
switch# copy usb1:dsn-config.cfg running-config
bootflash:n5000-uk9.4.2.1.N1.1.bin
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
21
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Step 4
Command or Action
Purpose
show running-config
(Optional) Displays the running configuration.
Example:
switch# show running-config
Step 5
copy running-config startup-config
Example:
(Optional) Copies the running configuration to the
startup configuration.
switch# copy running-config startup-config
Step 6
show startup-config
(Optional) Displays the startup configuration.
Example:
switch# show startup-config
Copying the Startup Configuration From an External Flash Memory Device
You can recover the startup configuration on your Cisco NX-OS device by downloading a new startup
configuration file saved on an external flash memory device.
Note
This procedure applies to the Cisco Nexus 5500 Platform running Cisco NX-OS Release 5.0.2 and later
releases.
Before You Begin
Insert the external flash memory device into the active supervisor module.
Step 1
Command or Action
Purpose
dir {usb1: | usb2:}[directory/]
(Optional) Displays the files on the external flash
memory device.
Example:
switch# dir usb1:
Step 2
copy {usb1: | usb2:}[directory/]filename startup-config
Example:
Copies the startup configuration from an external
flash memory device. The filename argument is case
sensitive.
switch# copy usb1:dsn-config.cfg startup-config
Step 3
copy {usb1: | usb2:}[directory/]filename startup-config
Example:
(Optional) You can copy the startup configuration
from an external flash memory device to the
bootflash.
switch# copy usb1:dsn-config.cfg startup-config
bootflash:n5000-uk9.4.2.1.N1.1.bin
Step 4
show startup-config
(Optional) Displays the startup configuration.
Example:
switch# show startup-config
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
22
OL-24969-01
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Step 1
Command or Action
Purpose
copy running-config startup-config
(Optional) Copies the running configuration to the
startup configuration.
Example:
switch# copy running-config startup-config
Step 1
(Optional) Displays the startup configuration.
show startup-config
Example:
switch# show startup-config
Upgrade Process in a Non-vPC Topology
The following list summarizes the upgrade process in a non-vPC topology:
1.
The install all command triggers the installation upgrade.
2.
The compatibility checks display the impact of the upgrade.
3.
The installation proceeds or not based on the upgrade impact.
4.
The current state is saved
5.
The system unloads and runs the new image.
6.
The stateful restart of the system software and application occurs.
7.
The installer resumes with the new image.
8.
The FEXs are upgraded sequentially.
9.
The installation completes.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
23
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Table 7 describes the process based on messages displayed on the console of the switch during an ISSU.
Table 7
The Switch Output During a Non-vPC ISSU
The install all command
is entered...
The image is verified ...
The image versions are
extracted...
The image compatibility
check begins...
The impact is
identified...
The upgrade begins...
The boot variables are
set...
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
24
OL-24969-01
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Table 7
The Switch Output During a Non-vPC ISSU (continued)
The configuration is
synchronized...
The BIOS and
power-sequence
upgrade occurs...
Caution
If an upgrade fails after this point in the process, the upgrade will be disruptive and the switch
will reboot.
Communication between
the FEX and the switch is
stopped...
The upgrade cleanup
process begins ...
Upgrade images load...
Runtime is saved...
vPC peer switches are
informed of ISSU
process...
Processes are
terminated...
In-transit messages and
reset reasons are
saved...
New kernel starts ...
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
25
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Table 7
The Switch Output During a Non-vPC ISSU (continued)
The supervisor resets...
The installer restarts...
The supervisor status is
verified...
The nondisruptive
upgrade on each module
begins...
The upgrade process is
complete.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
26
OL-24969-01
Upgrading Procedures
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Upgrade Process in vPC Topology on the Primary Switch
The following list summarizes the upgrade process on a primary switch in a vPC topology. Steps that
differ from a switch upgrade in a non-vPC topology are in bold.
Note
In vPC topologies, the two peer switches must be upgraded individually. When you start an upgrade on
one peer switch does not automatically update the vPC peer switch.
1.
The install all command issued on the vPC primary switch triggers the installation upgrade.
2.
The compatibility checks display the impact of the upgrade.
3.
The installation proceeds or not based on the upgrade impact.
4.
The configuration is locked on both vPC peer switches.
5.
The current state is saved
6.
The system unloads and runs the new image.
7.
The stateful restart of the system software and application occurs.
8.
The installer resumes with the new image.
9.
The FEXs are upgraded sequentially.
10. The installation is complete.
When the installation is complete, the vPC primary switch and the FEXs that are connected to the
primary switch are upgraded. The single-homed FEXs and the dual-homed FEXs are now running the
upgraded software.
Note
The dual-homed FEXs are now connected to the primary and secondary switches that are running two
different versions of Cisco NX-OS software. The vPC primary switch is running the upgraded version
and vPC secondary switch is running the original software version. Cisco NX-OS software has been
designed to allow an upgraded dual-home FEX to interoperate with vPC secondary switches running the
original version of Cisco NX-OS while the primary switch is running the upgrade version.
Upgrade Process in vPC Topology on the Secondary Switch
The following list summarizes the upgrade process on a secondary switch in a vPC topology. Steps that
differ from a switch upgrade in a non-vPC topology are in bold.
1.
The install all command issued on the vPC second switch triggers the installation upgrade.
2.
The compatibility checks display the impact of the upgrade.
3.
The installation proceeds or not based on the upgrade impact.
4.
The current state is saved
5.
The system unloads and runs the new image.
6.
The stateful restart of the system software and application occurs.
7.
The installer resumes with the new image.
8.
The FEXs are upgraded sequentially. The upgrade completes on the single-homed FEXs and
a sanity check is performed on the dual-homed FEXs.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
27
Disruptive Installation Process
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Note
9.
The dual-homed FEXs were upgraded by the primary switch.
The configuration is unlocked on the primary and secondary switches.
10. The installation is complete.
Disruptive Installation Process
The following lists conditions where a nondisruptive ISSU might not be possible when upgrading a
Cisco Nexus 5000 Series access layer switch:
•
The topology and/or features are not ISSU ready. Please see the section on ISSU pre-requisites for
more information.
•
The current release or target release is lower than 4.2(1)N1(1). ISSU can work only when both the
current and target releases are equal or later than 4.2(1)N1(1).
•
The installation is a downgrade – higher release to lower release, unless stated otherwise in
Release-specific Information section below.
•
The user wants to do a disruptive upgrade. Please see Forcing an Upgrade below.
Forcing an Upgrade
Users can choose to do a disruptive upgrade, if one of the ISSU conditions are not met. One additional
reason where a customer might choose to do a disruptive upgrade is described here – please note that
Cisco recommends an ISSU process in this case too. With ISSU, FEXs are upgraded in a rolling fashion
– one FEX at a time. This requires a longer maintenance window. With a disruptive upgrade all the
connected FEXs are upgraded simultaneously – so, the maintenance window can be shorter. If the user
needs a shorter maintenance window (with traffic disruption), he can force a disruptive upgrade even if
ISSU can be leveraged. It is important to note the possibility of an outage and take required steps in this
case.
switch # install all force kickstart bootflash:/kickstart_image.bin system
bootflash:/system_image.bin
Installer is forced disruptive
Verifying image bootflash:/kickstart_image.bin for boot variable "kickstart".
[####################] 100% -- SUCCESS
Verifying image bootflash:/system_image.bin for boot variable "system".
...
You can also add force at the end of the install all command as follows:
switch # install all kickstart bootflash:/kickstart_image.bin system
bootflash:/system_image.bin force
Installer is forced disruptive
Verifying image bootflash:/kickstart_image.bin for boot variable "kickstart".
...
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
28
OL-24969-01
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier Releases (Disruptive Upgrade)
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier
Releases (Disruptive Upgrade)
This section describes how to upgrade from Cisco NX-OS Release 4.1(3)N2(1) and earlier releases. An
upgrade from these releases will be disruptive. Upgrading a Cisco Nexus 5000 Series switch also
upgrades connected Fabric Extenders.
Note
To perform a nondisruptive upgrade from Cisco NX-OS Release 4.2(1)N1(1) and later releases, see the
“In-Service Software Upgrades” section on page 6.
SUMMARY STEPS
Step 1
Log in to Cisco.com to access the Software Download Center. To log in to Cisco.com, go to
http://www.cisco.com/ and click Log In at the top of the page. Enter your Cisco username and password.
Step 2
Select and download the kickstart and system software files to a local server.
Step 3
Verify that the required space is available in the bootflash: directory for the image file(s) to be copied.
Step 4
(Optional) If you need more space on the bootflash, delete unnecessary files to make space available.
Step 5
Copy the new kickstart and system images to the switch bootflash by using a transfer protocol such as
FTP, TFTP, SCP, or SFTP. The examples in this procedure use SCP.
Step 6
Enter the show install all impact command to display the impact of the upgrade.
Step 7
Enter the install all command to install the new images, specifying the new image names that you
downloaded in the previous step.
Step 8
Verify that the switch is running the required software release.
DETAILED STEPS
Step 1
Note
Log in to Cisco.com to access the Software Download Center. To log in to Cisco.com, go to
http://www.cisco.com/ and click Log In at the top of the page. Enter your Cisco username and password.
Unregistered Cisco.com users cannot access the links provided in this document.
Access the Software Download Center at http://www.cisco.com/public/sw-center/index.shtml.
Navigate to the software downloads for Cisco Nexus 5000 Series switches. Links to the download
images for the switch are listed.
Step 2
Select and download the kickstart and system software files to a local server.
Step 3
Verify that the required space is available in the bootflash: directory for the image file(s) to be copied.
switch# dir bootflash:
4681
May 24
13176836
May 24
49152
Jan 12
310556
Dec 23
20058112
Jun 25
20217856
May 09
76930262
Jun 25
103484727
May 09
02:43:52
07:19:36
18:38:36
02:53:28
23:17:44
23:17:11
23:11:47
23:10:02
2010
2010
2009
2008
2010
2010
2010
2010
config
gdb.1
lost+found/
n1
n5000-uk9-kickstart.4.1.3.N1.1.bin
n5000-uk9-kickstart.4.0.1a.N1.0.62.bin
n5000-uk9.4.1.3.N1.1.bin
n5000-uk9.4.0.1a.N1.0.62.bin
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
29
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier Releases (Disruptive Upgrade)
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Usage for bootflash://sup-local
74934272 bytes used
5550080 bytes free
80484352 bytes total
We recommend that you keep the kickstart and system image files for at least one previous software
release to use if the new image files do not load successfully.
Step 4
(Optional) If you need more space on the bootflash, delete unnecessary files to make space available.
switch# delete bootflash:n5000-uk9-kickstart.4.0.1a.N1.0.62.bin
switch# delete bootflash:n5000-uk9.4.0.1a.N1.0.62.bin
Step 5
Copy the new kickstart and system images to the switch bootflash by using a transfer protocol such as
FTP, TFTP, SCP, or SFTP. The examples in this procedure use SCP.
switch# copy scp://[email protected]/downloads/n5000-uk9.4.2.1.N1.1.bin
bootflash:n5000-uk9.4.2.1.N1.1.bin
switch# copy scp://[email protected]/downloads/n5000-uk9-kickstart.4.2.1.N1.1.bin
bootflash:n5000-uk9-kickstart.4.2.1.N1.1.bin
Step 6
Enter the show install all impact command to display the impact of the upgrade.
switch# show install all impact kickstart bootflash:n5000-uk9-kickstart.4.2.1.N1.1.bin
system bootflash:n5000-uk9.4.2.1.N1.1.bin
Verifying image bootflash:/n5000-uk9-kickstart.4.2.1.N1.1.bin for boot variable
"kickstart".
[####################] 100% -- SUCCESS
Verifying image bootflash:/n5000-uk9.4.2.1.N1.1.bin for boot variable "system".
[####################] 100% -- SUCCESS
Verifying image type.
[###########
] 50%
[####################] 100% -- SUCCESS
Extracting "system" version from image bootflash:/n5000-uk9.4.2.1.N1.1.bin.
[####################] 100% -- SUCCESS
Extracting "kickstart" version from image bootflash:/n5000-uk9-kickstart.4.2.1.N
1.1.bin.
[####################] 100% -- SUCCESS
Extracting "bios" version from image bootflash:/n5000-uk9.4.2.1.N1.1.bin.
[####################] 100% -- SUCCESS
Extracting "fex" version from image bootflash:/n5000-uk9.4.2.1.N1.1.bin.
[####################] 100% -- SUCCESS
Notifying services about system upgrade.
[####################] 100% -- SUCCESS
Compatibility check is done:
Module
-----1
100
bootable
-------yes
yes
Impact
-------------disruptive
disruptive
Install-type
-----------reset
reset
Reason
-----Reset due to single supervisor
Reset due to single supervisor
Images will be upgraded according to following table:
Module
Image
Running-Version
New-Version
------ ---------- ---------------------- ---------------------1
system
4.1(3)N1(1)
4.2(1)N1(1)
Upg-Required
-----------yes
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
30
OL-24969-01
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier Releases (Disruptive Upgrade)
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
1
1
100
Step 7
kickstart
bios
fex
4.1(3)N1(1)
v1.3.0(09/08/09)
4.1(3)N1(1)
4.2(1)N1(1)
yes
no
yes
4.2(1)N1(1)
Enter the install all command to install the new images, specifying the new image names that you
downloaded in the previous step.
switch#
install all kickstart bootflash:n5000-uk9-kickstart.4.2.1.N1.1.bin system
bootflash:n5000-uk9.4.2.1.N1.1.bin
Verifying image bootflash:/n5000-uk9-kickstart.4.2.1.N1.1.bin for boot variable
"kickstart".
[####################] 100% -- SUCCESS
Verifying image bootflash:/n5000-uk9.4.2.1.N1.1.bin for boot variable "system".
[####################] 100% -- SUCCESS
Verifying image type.
[####################] 100% -- SUCCESS
Extracting "system" version from image bootflash:/n5000-uk9.4.2.1.N1.1.bin.
[####################] 100% -- SUCCESS
Extracting "kickstart" version from image bootflash:/n5000-uk9-kickstart.4.2.1.N1.1.bin.
[####################] 100% -- SUCCESS
Extracting "bios" version from image bootflash:/n5000-uk9.4.2.1.N1.1.bin.
[####################] 100% -- SUCCESS
Extracting "fex" version from image bootflash:/n5000-uk9.4.2.1.N1.1.bin.
[####################] 100% -- SUCCESS
Notifying services about system upgrade.
[####################] 100% -- SUCCESS
Compatibility check is done:
Module bootable
Impact Install-type
------ -------- -------------- -----------1
yes
disruptive
reset
100
yes
disruptive
reset
Reason
-----Reset due to single supervisor
Reset due to single supervisor
Images will be upgraded according to following table:
Module
Image
Running-Version
New-Version
------ ---------- ---------------------- ---------------------1
system
4.1(3)N1(1)
4.2(1)N1(1)
1
kickstart
4.1(3)N1(1)
4.2(1)N1(1)
1
bios
v1.3.0(09/08/09)
100
fex
4.1(3)N1(1)
4.2(1)N1(1)
Switch will be reloaded for disruptive upgrade.
Do you want to continue with the installation (y/n)?
Upg-Required
-----------yes
yes
no
yes
[n] y
Install is in progress, please wait.
Setting boot variables.
[####################] 100% -- SUCCESS
Performing configuration copy.
[####################] 100% -- SUCCESS
Module 1: Refreshing compact flash and upgrading bios/loader/bootrom.
Warning: please do not remove or power off the module at this time.
[####################] 100% -- SUCCESS
Pre-loading modules.
[This step might take up to 20 minutes to complete - please wait.]
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
31
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier Releases (Disruptive Upgrade)
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
[#
]
0%2010 Jun 10 18:27:25 N5K1 %$ VDC-1 %$ %SATCTRL-2-SATCTRL_IMAGE:
FEX100 Image update in progress.
[#####
] 20%
[######
] 25%2010 Jun 10 18:32:54 N5K1 %$ VDC-1 %$ %SATCTRL-2-SATCTRL_IMAGE:
FEX100 Image update complete. Install pending
[####################] 100% -- SUCCESS
Finishing the upgrade, switch will reboot in 10 seconds.
switch#
switch#
switch# writing reset reason 31,
Broadcast message from root (Thu Jun 10 18:33:16 2010):
INIT: Sending processes the TERM signal
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "stp" (PID 2843) is forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "netstack" (PID 2782) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "Security Daemon" (PID 2706) is
forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "Cert_enroll Daemon" (PID 2707) is
forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "igmp" (PID 2808) is forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "Radius Daemon" (PID 2806) is
forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "AAA Daemon" (PID 2708) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "vshd" (PID 2636) is forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "vlan_mgr" (PID 2737) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "vdc_mgr" (PID 2681) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "urib" (PID 2718) is forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "u6rib" (PID 2717) is forced exit.
Jun 10 18:33:17 %TTYD-2-TTYD_ERROR TTYD Error ttyd bad select
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "statsclient" (PID 2684) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "smm" (PID 2637) is forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "res_mgr" (PID 2688) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "licmgr" (PID 2641) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "l3vm" (PID 2715) is forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "icmpv6" (PID 2781) is forced
exit.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
32
OL-24969-01
Upgrading From Cisco NX-OS Release 4.1(3)N2(1) and Earlier Releases (Disruptive Upgrade)
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "eth_dstats" (PID 2700) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "arp" (PID 2780) is forced exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "fs-daemon" (PID 2642) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "ascii-cfg" (PID 2704) is forced
exit.
Jun 10 18:33:17 %LIBSYSMGR-3-SIGTERM_FORCE_EXIT Service "adjmgr" (PID 2771) is forced
exit.
Jun 10 18:33:19 Unexporting directories for NFS kernel daemon...done.
Stopping NFS kernel daemon: rpc.mountd rpc.nfsddone.
Unexporting directories for NFS kernel daemon...
done.
Stopping portmap daemon: portmap.
Stopping kernel log daemon: klogd.
Sending all processes the TERM signal... done.
Sending all processes the KILL signal... done.
Unmounting remote filesystems... done.
Deactivating swap...umount: none busy - remounted read-only
done.
Unmounting local filesystems...umount: none busy - remounted read-only
done.
mount: you must specify the filesystem type
Starting reboot command: reboot
Rebooting...
Restarting system.
The switch reboots and restarts with the new image.
For detailed information about the install all command, see Using the install all Command.
Caution
After completing the installation, all traffic through the switch is disrupted while the
switch reboots.
Step 8
Verify that the switch is running the required software release.
switch# show version
Cisco Nexus Operating System (NX-OS) Software
TAC support: http://www.cisco.com/tac
Copyright ) 2002-2010, Cisco Systems, Inc. All rights reserved.
The copyrights to certain works contained herein are owned by
other third parties and are used and distributed under license.
Some parts of this software are covered under the GNU Public
License. A copy of the license is available at
http://www.gnu.org/licenses/gpl.html.
Software
BIOS:
version 1.2.0
loader:
version N/A
kickstart: version 4.2(1)N1(1) [build 4.2(1)N1(0.96)]
system:
version 4.2(1)N1(1) [build 4.2(1)N1(0.96)]
BIOS compile time:
06/19/09
kickstart image file is: bootflash:/n5000-uk9-kickstart.4.2.1.N1.0.96.bin
kickstart compile time: 7/14/2010 4:00:00 [07/14/2010 04:27:38]
system image file is:
bootflash:/n5000-uk9.4.2.1.N1.0.96.bin
system compile time:
7/14/2010 4:00:00 [07/14/2010 05:20:12]
Hardware
cisco Nexus5020 Chassis ("40x10GE/Supervisor")
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
33
Minimizing the Impact of a Disruptive Upgrade
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Intel) Celeron) M CPU
with 2074240 kB of memory.
Processor Board ID JAB1232002F
Device name: switch
bootflash:
1003520 kB
Kernel uptime is 13 day(s), 23 hour(s), 25 minute(s), 5 second(s)
Last reset at 720833 usecs after
Tue Jul 14 11:18:32 2010
Reason: Reset by installer
System version: 4.2(1)N1(0.96)
Service:
plugin
Core Plugin, Ethernet Plugin
Minimizing the Impact of a Disruptive Upgrade
A non-ISSU upgrade is a disruptive upgrade that results in the reload of the Cisco Nexus 5000 Series
switch and the Cisco Nexus 2000 Series Fabric Extenders. The reload is a cold reboot that brings down
the control plan and the data plane. The reload causes disruptions to the connected servers and hosts.
When vPC is deployed in the access layer, it is possible to minimize the impact of a non-ISSU upgrade.
When one of the vPC switches is being reset during the upgrade process, all the server traffic can flow
through its vPC peer thereby reducing the impact.
To reduce the disruption of a disruptive upgrade, follow these steps:
Upgrading A Direct Vpc Or A Single-Homed Fex Access Layer
The following figures show topologies in which the access layer includes a vPC configuration to hosts
or downstream switches.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
34
OL-24969-01
Minimizing the Impact of a Disruptive Upgrade
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Figure 15
Hosts Directly Connected Directly to vPC Peers
Aggregation
Nexus 5020
Nexus 2000
Nexus 2000
237883
Nexus 5010
Figure 16
vPC Peered Dual-Supervisor Virtual Modular System Dual-Homed FEXs and
Singled-Homed FEXs
Aggregation
Nexus 5020
Nexus 2000
Nexus 2000
237884
Nexus 5010
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
35
Monitoring the Upgrade Status
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Figure 17
Cisco Nexus 5000 Series Switches Connected To Downstream Switches
Nexus 5020
237890
Nexus 5010
To upgrade the access layer without a disruption to hosts, follow these tasks:
•
Upgrade the first vPC switch (vPC primary switch) – during this upgrade, the switch will be
reloaded. When the switch is reloaded, the servers or the downstream switch detects loss of
connectivity to the first switch and will start forwarding traffic to second (vPC secondary) switch.
•
Verify that the upgrade of the switch has completed successfully. At the completion of the upgrade,
the switch will restore vPC peering, connected Nexus 2000 Fabric Extenders and all the links.
•
Upgrade the second switch – repeating the same process on the second switch will cause the second
switch to reload during the upgrade process. During this reload, the first (upgraded) switch will
forward all the traffic to/from servers.
•
Verify that the upgrade of the second switch has completed successfully. At the end of this upgrade,
complete vPC peering is established and the entire switch and the FEX access layer would’ve been
upgraded.
Note
Flows that are forwarded to a switch during an upgrade on the switch, will failover to the second switch.
Also, flows are redistributed when vPC peers are active. The traffic disruption is limited to the time
required for the server or host to detect the link-down and link-up events and to redistribute the flows.
Note
Upgrading Cisco NX-OS Software by changing the boot-variables and performing a reload is not
supported in Cisco Nexus 5000 and 6000 Series Switches. This may result in loss of configuration and
forwarding issues.
Monitoring the Upgrade Status
Table 1-8 lists the show commands that are used to monitor installation upgrades.
Table 1-8
Monitoring the Upgrade Process
Command
Definition
show fex
Displays the fabric extender status during an ISSU.
show install all failure-reason
Displays the applications that failed during an installation and why
the installation failed.
show install all status
Displays a high-level log of the installation.
show system internal log install
details
Displays detailed logs of the last installation-related command.
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
36
OL-24969-01
Downgrading From a Higher Release
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Table 1-8
Monitoring the Upgrade Process (continued)
Command
Definition
show system internal log install
history
Displays detailed logs of the last five installation-related
commands, from oldest to newest.
show tech-support
Displays the system and configuration information that you can
provide to the Cisco Technical Assistance Center when reporting
a problem.
The following example shows the output from the show install all status command:
There is an on-going installation...
Enter Ctrl-C to go back to the prompt.
Continuing with installation process, please wait.
The login will be disabled until the installation is completed.
Performing supervisor state verification.
SUCCESS
Supervisor non-disruptive upgrade successful.
Pre-loading modules.
SUCCESS
Module 198: Non-disruptive upgrading.
SUCCESS
Module 199: Non-disruptive upgrading.
SUCCESS
Install has been successful.
(hit Ctrl-C here)
The following example shows the output from the show fex command on two vPC peer switches where
Fex 198 and Fex 199 are upgraded:
switch-1# show fex
FEX
FEX
FEX
FEX
Number
Description
State
Model
Serial
-----------------------------------------------------------------------198
FEX0198
Hitless Upg Idle
N2K-C2248TP-1GE
JAF1342ANQP
199
FEX0199
Online
N2K-C2248TP-1GE
JAF1342ANRL
switch-2# show fex
FEX
FEX
FEX
FEX
Number
Description
State
Model
Serial
-----------------------------------------------------------------------198
FEX0198
FEX AA Upg Idle
N2K-C2248TP-1GE
JAF1342ANQP
199
FEX0199
Online
N2K-C2248TP-1GE
JAF1342ANRL
Downgrading From a Higher Release
The procedure to downgrade the switch is identical to a switch upgrade, except that the image files to be
loaded are for an earlier release than the image that is currently running on the switch. User can use the
show incompatibility system command to ensure that there are no feature incompatibilities between
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
37
Troubleshooting ISSUs and Disruptive Installations
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
current release and the target release. Please note that downgrades disruptive. Please refer to the
Release-specific information section to get information about certain downgrades that are
non-disruptive.
Note
Before you downgrade to a specific release, check the release notes for the current release installed on
the switch, to ensure that your hardware is compatible with the specific release. You must be aware of
special caveats before you downgrade the switch software to a Cisco NX-OS 4.0(0)-based release. See
the Cisco Nexus 5000 Series switch and Cisco Nexus 2000 Series Release Notes for details.
Troubleshooting ISSUs and Disruptive Installations
Some of the common causes for ISSU failure include
•
ISSU requisites are not met – bridge assurance is active or switch is not a leaf node in STP topology.
These are indicated by commands explained in Pre-ISSU Checks section
•
bootflash: does not have enough space to the accept the updated image
•
Specified system and kickstart are not compatible
•
Hardware is installed or removed while the upgrade is in process
•
Any power disruption while upgrade is in progress
•
The entire path for the remote server location is not specified accurately
The following commands can be used to query the status of install and reasons for failures, if any show
install all failure-reason displays the application that failed during an installation and why the
installation failed show install all status displays a high level log of the last installation show system
internal log install details displays detailed logs of the last installation related command show system
internal log install history displays detailed logs of the last 5 installation related commands, from
oldest to newest.
Related Documentation
Documentation for Cisco Nexus 3000 Series Switches and Cisco Nexus 2000 Series Fabric Extenders is
available at the following URL:
http://www.cisco.com/en/US/products/ps9670/tsd_products_support_series_home.html
The following are related Cisco Nexus 3000 Series and Cisco Nexus 2000 Series Fabric Extender
documents:
Release Notes
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Release Notes
Cisco Nexus 5000 Series Switch Release Notes
Configuration Guides
Cisco Nexus 5000 Series Configuration Limits for Cisco NX-OS Release 5.0(2)N1(1b)
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
38
OL-24969-01
Related Documentation
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Cisco Nexus 5000 Series Configuration Limits for Cisco NX-OS Release 4.2(1)N1(1) and
Release 4.2(1)N2(1)
Cisco Nexus 5000 Series NX-OS Fibre Channel over Ethernet Configuration Guide
Cisco Nexus 5000 Series NX-OS Layer 2 Switching Configuration Guide
Cisco Nexus 5000 Series NX-OS Multicast Routing Configuration Guide
Cisco Nexus 5000 Series NX-OS Quality of Service Configuration Guide
Cisco Nexus 5000 Series NX-OS SAN Switching Configuration Guide
Cisco Nexus 5000 Series NX-OS Security Configuration Guide
Cisco Nexus 5000 Series NX-OS System Management Configuration Guide
Cisco Nexus 5000 Series NX-OS Unicast Routing Configuration Guide
Cisco Nexus 5000 Series Switch NX-OS Software Configuration Guide
Cisco Nexus 5000 Series Fabric Manager Configuration Guide, Release 3.4(1a)
Cisco Nexus 7000 Series NX-OS Fundamentals Configuration Guide, Release 4.2
Cisco Nexus 2000 Series Fabric Extender Software Configuration Guide
Maintain and Operate Guides
Cisco Nexus 5000 Series NX-OS Operations Guide
Installation and Upgrade Guides
Cisco Nexus 5000 Series and Cisco Nexus 5500 Platform Hardware Installation Guide
Cisco Nexus 2000 Series Hardware Installation Guide
Cisco Nexus 5000 Series NX-OS Software Upgrade and Downgrade Guide, Release 4.2(1)N1(1)
Regulatory Compliance and Safety Information for the Cisco Nexus 5000 Series Switches and Cisco
Nexus 2000 Series Fabric Extenders
Licensing Guide
Cisco NX-OS Licensing Guide
Command References
Cisco Nexus 5000 Series Command Reference
Technical References
Cisco Nexus 5000 Series and Cisco Nexus 2000 Series Fabric Extender MIBs Reference
Cisco Nexus 5000 Series NX-OS Upgrade and Downgrade Guide, Release 5.0
OL-24969-01
39
Obtaining Documentation and Submitting a Service Request
Se n d c o m m e n t s t o n ex u s 5 k - d o c f e e d b a ck @ c i s c o . c o m
Error and System Messages
Cisco NX-OS System Messages Reference
Troubleshooting Guide
Cisco Nexus 5000 Troubleshooting Guide
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, using the Cisco Bug Search Tool (BST), submitting a
service request, and gathering additional information, see What’s New in Cisco Product Documentation.