Radioactive Materials Unit PO Box 64975 St. Paul, MN 55164-0975 Phone: 651-201-4400 • Fax 651-201-3999 PRAIRIE ISLAND NUCLEAR GENERATING PLANT INDEPENDENT SPENT FUEL STORAGE INSTALLATION Introduction This report provides data on radiation levels inside the Xcel Energy, Inc. (XE) Independent Spent Fuel Storage Installation (ISFSI) at the Prairie Island Nuclear Generating Plant (PINGP) for May 2014. The data contained in this report were gathered in accordance with agreements between Xcel Energy, Inc. and the Minnesota Department of Health (MDH). At the end of May 2014, 35 casks were storing spent fuel inside the Independent Spent Fuel Storage Installation. The last cask to be moved to the Independent Spent Fuel Storage Installation was placed on June 25, 2013. Pressurized Ionization Chamber (PIC) Monitoring During this reporting period, daily radiation data were collected by the Pressurized Ionization Chamber system, which was installed in January 1995. The system consists of two ion chambers, computer memories and modems that are contacted every 15 minutes by the Minnesota Department of Health computers in St. Paul. The computers automatically page Minnesota Department of Health staff if unusual radiation levels are detected or if there are communication errors. Pressurized Ionization Chamber No. 1 is located about 100 feet north of the casks and Pressurized Ionization Chamber No. 2 is about 100 feet south. Data were collected from May 1, 2014 to May 31, 2014 and are summarized in Table 1 for Pressurized Ionization Chamber No. 1 and Table 2 for Pressurized Ionization Chamber No. 2. Daily averages are presented, though data for every 15 minutes are available. A chart showing the daily averages for each Pressurized Ionization Chamber is also included. Pressurized Ionization Chamber No. 1 did not work in May. Pressurized Ionization Chamber No. 2 was working properly during the month of May. Analysis and Comments Pressurized Ionization Chamber No. 2 readings ranged from 152.8 to 162.0 μR/hr. The normal range of ambient radiation levels inside the Independent Spent Fuel Storage Installation near the casks (about 100 feet away) has been 150 to 190 μR/hr. Before any casks were in place, the natural background radiation levels inside the Independent Spent Fuel Storage Installation ranged from 5 to 15 μR/hr. Additional monitoring data on radioactivity levels in other media (air, for example) are available in the annual Minnesota Department of Health "Environmental Radiation Data Report." For more information, go to: http://www.health.state.mn.us/divs/eh/radiation/monitor/index.html or contact Brandon Juran at [email protected] or 651-201-4526. 1 Table 1: May 2014 Data Report for Pressurized Ionization Chamber No. 1 Start Date Start Times End Times Dose (mR) Intv Status 2 400v 6v Avg (uR/h) Max (uR/h) Min (uR/h) Cnt Table 2: May 2014 Data Report for Pressurized Ionization Chamber No. 2 Start Date Start Times 5/1/2014 0:13 5/2/2014 0:13 5/3/2014 0:01 5/4/2014 0:01 5/5/2014 0:13 5/6/2014 0:11 5/7/2014 0:05 5/8/2014 0:09 5/9/2014 0:02 5/10/2014 0:11 5/11/2014 0:09 5/12/2014 0:11 5/13/2014 0:02 5/14/2014 0:11 5/15/2014 0:01 5/16/2014 0:10 5/17/2014 0:11 5/18/2014 0:10 5/19/2014 0:02 5/20/2014 0:13 5/21/2014 0:11 5/22/2014 0:10 5/23/2014 0:11 5/24/2014 0:11 5/25/2014 0:01 5/26/2014 0:11 5/27/2014 0:13 5/28/2014 0:01 5/29/2014 0:29 5/30/2014 0:14 5/31/2014 0:14 5/1/14 to 5/31/14 End Times 23:59 23:46 23:46 23:59 23:59 23:50 23:56 23:47 23:56 23:56 23:56 23:47 23:56 23:46 23:54 23:56 23:56 23:47 23:58 23:54 23:56 23:54 23:54 23:46 23:56 23:59 23:46 23:26 23:59 23:59 23:56 Dose (mR) 3.78 3.75 3.74 3.73 3.72 3.73 3.73 3.76 3.75 3.75 3.75 3.77 3.74 3.73 3.74 3.74 3.73 3.72 3.75 3.74 3.73 3.72 3.72 3.71 3.72 3.73 3.74 3.72 3.72 3.71 3.72 115.7 Intv Status 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 900 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 300v 277 278 277 278 279 279 279 279 279 279 280 280 278 278 278 278 279 280 279 280 280 280 280 281 281 282 281 281 281 282 282 279 12v 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 14.2 Avg (uR/h) 157.4 156.2 156.0 155.5 155.2 155.3 155.6 156.6 156.2 156.1 156.3 157.0 156.0 155.6 155.8 155.7 155.4 155.1 156.3 155.7 155.4 155.1 154.8 154.7 154.8 155.3 156.0 154.9 154.8 154.7 154.8 155.6 Max (uR/h) 159.3 156.9 157.4 156.5 156.2 156.2 161.8 160.4 156.7 157.3 160.1 162.0 157.0 157.1 156.5 156.8 156.7 156.5 159.6 156.5 156.3 156.4 156.5 156.1 156.0 160.3 157.1 156.1 156.2 155.8 155.6 162.0 Min (uR/h) 155.7 155.5 154.9 154.4 154.2 154.5 154.8 155.6 155.4 155.0 155.0 155.4 155.1 154.3 155.2 154.8 154.2 153.8 152.8 154.2 154.4 153.8 153.6 153.4 153.8 153.7 155.2 153.8 153.5 153.6 154.0 152.8 Cnt 92 94 93 95 95 94 95 94 95 94 95 94 95 93 95 94 94 94 95 94 95 95 94 93 95 94 94 94 94 94 95 2921 2009 - 2014 Daily Average HPIC Readings 200 180 160 140 μR/hr 120 100 PIC 1 80 PIC 2 60 40 20 4/1/2014 1/1/2014 10/1/2013 7/1/2013 4/1/2013 1/1/2013 10/1/2012 7/1/2012 4/1/2012 1/1/2012 10/1/2011 7/1/2011 4/1/2011 1/1/2011 10/1/2010 7/1/2010 4/1/2010 1/1/2010 10/1/2009 7/1/2009 4/1/2009 1/1/2009 0 This chart shows relatively stable readings with an increase in 2013. This increase was due to the placement of 6 casks to the ISFSI from April to June 2013. 4
© Copyright 2026 Paperzz