Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits
for NX-OS Release 7.3(0)N1(1)
First Published: January 15, 2014
Last Modified: December 22, 2014
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS,
INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND,
EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH
THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY,
CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB's public domain version
of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS" WITH ALL FAULTS.
CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT
LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network
topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional
and coincidental.
Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: http://
www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership
relationship between Cisco and any other company. (1110R)
© 2016
Cisco Systems, Inc. All rights reserved.
CONTENTS
Preface
Preface v
Audience v
Document Conventions v
Documentation Feedback vii
Obtaining Documentation and Submitting a Service Request vii
CHAPTER 1
Configuration Limits for FC and FCoE, Cisco NX-OS Release 7.3(0)N1(1) 1
Overview 1
Switch Level Fibre Channel Configuration Limits 1
Switch Level Fibre Channel over Ethernet Configuration Limits 2
Fabric Level Configuration Limits 3
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
iii
Contents
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
iv
Preface
The Preface contains the following sections:
• Audience, page v
• Document Conventions, page v
• Documentation Feedback, page vii
• Obtaining Documentation and Submitting a Service Request, page vii
Audience
This publication is for network administrators who configure and maintain Cisco Nexus devices.
Document Conventions
Note
As part of our constant endeavor to remodel our documents to meet our customers' requirements, we have
modified the manner in which we document configuration tasks. As a result of this, you may find a
deviation in the style used to describe these tasks, with the newly included sections of the document
following the new format.
Command descriptions use the following conventions:
Convention
Description
bold
Bold text indicates the commands and keywords that you enter literally
as shown.
Italic
Italic text indicates arguments for which the user supplies the values.
[x]
Square brackets enclose an optional element (keyword or argument).
[x | y]
Square brackets enclosing keywords or arguments separated by a vertical
bar indicate an optional choice.
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
v
Preface
Document Conventions
Convention
Description
{x | y}
Braces enclosing keywords or arguments separated by a vertical bar
indicate a required choice.
[x {y | z}]
Nested set of square brackets or braces indicate optional or required
choices within optional or required elements. Braces and a vertical bar
within square brackets indicate a required choice within an optional
element.
variable
Indicates a variable for which you supply values, in context where italics
cannot be used.
string
A nonquoted set of characters. Do not use quotation marks around the
string or the string will include the quotation marks.
Examples use the following conventions:
Convention
Description
screen font
Terminal sessions and information the switch displays are in screen font.
boldface screen font
Information you must enter is in boldface screen font.
italic screen font
Arguments for which you supply values are in italic screen font.
<>
Nonprinting characters, such as passwords, are in angle brackets.
[]
Default responses to system prompts are in square brackets.
!, #
An exclamation point (!) or a pound sign (#) at the beginning of a line
of code indicates a comment line.
This document uses the following conventions:
Note
Caution
Means reader take note. Notes contain helpful suggestions or references to material not covered in the
manual.
Means reader be careful. In this situation, you might do something that could result in equipment damage
or loss of data.
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
vi
Preface
Documentation Feedback
Documentation Feedback
To provide technical feedback on this document, or to report an error or omission, please send your comments
to: [email protected].
We appreciate your feedback.
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, using the Cisco Bug Search Tool (BST), submitting a service
request, and gathering additional information, see What's New in Cisco Product Documentation, at: http://
www.cisco.com/c/en/us/td/docs/general/whatsnew/whatsnew.html.
Subscribe to What's New in Cisco Product Documentation, which lists all new and revised Cisco technical
documentation as an RSS feed and delivers content directly to your desktop using a reader application. The
RSS feeds are a free service.
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
vii
Preface
Obtaining Documentation and Submitting a Service Request
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
viii
CHAPTER
1
Configuration Limits for FC and FCoE, Cisco
NX-OS Release 7.3(0)N1(1)
This chapter contains the following sections:
• Overview, page 1
• Switch Level Fibre Channel Configuration Limits, page 1
• Switch Level Fibre Channel over Ethernet Configuration Limits, page 2
• Fabric Level Configuration Limits, page 3
Overview
This document lists the Cisco verified configuration limits for fibre channel (FC) and fibre channel over
ethernet (FCoE).
In the following tables, the switch level (FC and FCoE) fabric level (mixed fabric) features, parameters, and
the verified scale values are listed. The numbers listed are for Cisco Nexus 5500, 5600, 6000 series switches
and the Cisco Nexus 5672-16G switch.
Switch Level Fibre Channel Configuration Limits
This table lists the switch level fibre channel (FC) configuration limits.
Table 1: Switch Level FC Configuration Limits
Feature
Parameter
N55xx
N60xx
N56xx
N5672-16G
FC Logins (FLOGI or FLOGIs or FDISCs per port
FDISC)
FLOGIs or FDISC per switch
256
256
256
256
1000
1000
1000
1000
FC Inter-Switch Links ISL instances per switch
(ISLs)
12
12
12
12
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
1
Configuration Limits for FC and FCoE, Cisco NX-OS Release 7.3(0)N1(1)
Switch Level Fibre Channel over Ethernet Configuration Limits
Feature
Parameter
N55xx
N60xx
N56xx
N5672-16G
FC Port Channels
Maximum number of port
channels
4
4
4
4
Maximum number of member
ports in a port-channel
16
16
16
8
Without FEX (only Base ports)
96
60
60
24
With FEX (Base ports + FEX
ports)
NA*
NA*
96
96
NA*
NA*
500
500
Maximum FC FEXes Number of FC FEXes connected NA*
to switch
NA*
24
24
VSAN
32
32
14
8
8
8
Maximum FC Ports
Maximum FC Logins Number of FC logins per FEX
per FEX
Maximum number of VSANs per 32
switch
N-Port Virtualization NPV switches per NPIV core
(NPV)
switch
8
* - FC FEX is not supported on Nexus 55xx and Nexus 60xx platforms.
Switch Level Fibre Channel over Ethernet Configuration Limits
This table lists the switch level fibre channel over ethernet (FCoE) configuration limits.
Table 2: Switch Level FCoE Configuration Limits
Feature
N55xx
N60xx
N56xx
N5672-16G
FCoE Logins (FLOGI FLOGIs or FDISCs per port
or FDISC)
FLOGIs or FDISC per switch
256
256
256
256
1000
1000
1000
1000
FCoE Inter-Switch
Links (ISLs)
ISL instances per switch
12
12
12
12
FCoE Port Channels
Maximum number of port
channels
12
12
12
12
Maximum number of member
ports in a port-channel
16
16
16
16
Maximum number of
VSAN-VLAN Mappings
32
32
32
14
VSAN-VLAN
Mapping
Parameter
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
2
Configuration Limits for FC and FCoE, Cisco NX-OS Release 7.3(0)N1(1)
Fabric Level Configuration Limits
Feature
Parameter
N55xx
N60xx
N56xx
N5672-16G
VFC
Maximum VFCs across base
ports/FEX ports/VPCs (across
maximum number of FEXs)
544
544
544
544
VFC Port Channels
Maximum number of VFC port
channels
12(16)
12(16)
12(16)
12(16)
Maximum FCoE
FEXes
Number of FCoE FEXes
connected to switch
24
24
24
24
Maximum FCoE
Logins per FEX
Number of FCoE logins per FEX 500
500
500
500
VSAN
Maximum number of VSANs per 32
switch
32
32
14
8
8
8
N-Port Virtualization FCoE NPV switches per NPIV
(NPV)
core switch
8
Fabric Level Configuration Limits
Table 3: Fabric Level Configuration Limits
Feature
Parameter
Mixed Fabric (M9710 + M95xx + N55x
+ N56xx + N60xx + N5672-16G)
VSANs
Number of VSANs per physical fabric
14
Logins and aliases Number of FCNS entries in fabric
Domains and
Hops
Zone
10000
Number of device alias entries in fabric
8000
Number of domains per physical fabric
80
Number of switch hops from server to storage
7
Zone Members
16000
Zones
8000
Zone Sets
32
Zone DB Size
2 MB
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
3
Configuration Limits for FC and FCoE, Cisco NX-OS Release 7.3(0)N1(1)
Fabric Level Configuration Limits
Cisco Nexus 5000 and 6000 Series FC and FCoE Configuration Limits for NX-OS Release 7.3(0)N1(1)
4
© Copyright 2026 Paperzz